Loading…
Loading…
Tender Value
₹5.8 Cr
EMD Value
₹11.5 L
Closing Date
29 May 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
DYCSTE/OFC
14 conditions · 3 needing a document upload
Financial Eligibility Criteria: Refer Para 2.5.3 of Tender Document
similar nature and technical eligibility: Refer para 2.5.1 & 2.5.2 of Tender Document.
Documents to be Submitted Along with Tender as per the para 14 of GCC
1 condition
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Provision of Tower wagon sidings at PUU & SCT and provision of Mini IPS at 43 LC Gates over Madurai division & 02 LC Gates over Salem Division in connection with leftover Railway Electrification works.
Proj1MS_TWS_RE_2026-02
Proj1MS_TWS_RE_2026-02
Open
Works - General
9 Months
Chennai, Tamil Nadu
₹0
₹11.5 L
29 May 2026
5 May 2026
15 May 2026
110 items across 1 schedule · ₹3,17,25,370.25 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | "Submission of all relevent final 'As mades' of circuit diagrams, contact analysis charts, termination particulars of apparatus cases and cable termination rack, power supply arrangements, relay index board, cable plans, cable route plans, red boundary plans and all other particulars covered under various schedules. All 'As mades' shall be prepared by the Contractor in AUTOCAD 2000 or latest and submitted in CDs. One copy of the 'As mades' check print shall be submitted before Testing the circuits. The final negatives shall be made in tracing sheet (80 to 90 gsm). All 'As mades' except cable plan, cable route plan, bonding diagram & power supply diagram shall be prepared in A3 size. On approval the contractor shall submit along with the negatives, 8 copies in each, duly making booklet neatly bound. Out of 8 sets, 2 sets of drawings and other plans shall be kept in transparent plastic cover (2 sheets back to back in one plastic cover) and handed over to Railways. Also the contractor has to supply one set of As mades in 'Reproduction Film'. The approved circuit diagram will be issued by Railways in soft copy as well as two sets of hard copies. Wherever alterations to existing circuits are involved, the existing as-made circuit diagrams will be supplied by Railways either in CDs or RP film. The Contractor shall incoporate the details of all the new wirings and alterations in the CD/ RP film and submit them to Railways. Onapproval 8 copies shall be made for As-made circuit diagrams also as mentioned above" | Sheet | 1200.00 | 382.12 | 4,58,544 |
| 2 | "Supply a n d Provision o f 6 4 Input Digital S t a c k C a r d (Digital I n p u t C a r d ) t o suit Datalogger a s per IRS S-99/2006 amt 3 or latest" | Numbers | 2.00 | 26,458.78 | 52,917.56 |
| 3 | Wiring o f Relay Inputs t o Wago Block and Wago block to Datalogger. Necessary Wagos required is included as per schedule | Per Unit | 40.00 | 285.86 | 11,434.4 |
| 4 | Wiring of Analog Voltages from IPS Room to Datalogger. Necessary Wagos required is included as per schedule | Numbers | 220.00 | 285.86 | 62,889.2 |
| 5 | Supply of indicative type Surge Protection Device as per RDSO Spec. No. SPN/165/ 2023, Version 4.0 Amdt.1 or latest (Lightning and Transient surge protection for power line). The system shall have stage1 (class B) and stage 2 (class C) type against Lightning electromagnetic Impulse configuration. The protection of Type 1 and 2 against Lightning electromagnetic Impulse (LEMP) and other high surge, shall be provided at the incoming of the power line at the stations, LC gates before the power equipment's as per the instructions of Engineer in-charge at site. Supply of surge protection with Potential free contacts shall be of approved make like OBO, DEHN, PHOENIX, LPT or better make. All other miscellaneous materials required for the work shall be supplied by the contractor. (as per Technical Specification enclosed) | Numbers | 2.00 | 22,756.39 | 45,512.78 |
| 6 | Supply and Provision of indicative type Class D Surge Protection Device f o r 24V DC/48V DC (spark gap type), with Potential Free contacts and installed as per the instructions of the Engineer in charge at site ( OBO, DEHN, PHOENIX, LPI, ZOTUP, HAKEL or better make).All o t h e r miscellaneous materials required for installation shall be supplied by the contractor. | Numbers | 2.00 | 6,328.8 | 12,657.6 |
| 7 | Supply and Provision of indicative type Class D SPD of Operating Voltage of 110V AC/DC with Potential Free contacts and installed as per t h e instructions o f the Engineer in charge a t s i t e ( O B O , DEHN, PHOENIX, LPI, ZOTUP, HAKEL or better make). All o t h e r miscellaneous materials required for installation shall be supplied by the contractor. | Numbers | 2.00 | 6,830.72 | 13,661.44 |
| 8 | Supply a n d Provision o f Earthing a s per RDSO Specification RDSO/SPN/197/2008 or l a t e s t ( a s p e r Te c h n i c a l Specification enclosed) | Numbers | 12.00 | 28,118.51 | 3,37,422.12 |
| 9 | Provision of earth electrodes as per drawing No.SG/CN/02/13 and earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, SM's room for block and control, and earthing of all equipments in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS flat 35mm X 6mm/19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, M sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 117.00 | 1,707.55 | 1,99,783.35 |
| 10 | "Full Location: Supply and fixing of GI Flat of s i z e 1050x25x3mm a s given i n enclosed drawing t o connect a l l c a b l e armours to earth point with suitable nuts/bolts as given below. A) GI nuts/bolts of size 8x25mm with Two flat and one spring washer of 23set. B) GI nuts/bolts of size 12x40mm with two flat and one spring washer of 02set as per site incharge" | Location Box | 8.00 | 1,370.66 | 10,965.28 |
| 11 | "Half Location: Supply and fixing of GI Flat of size 550x25x3mm a s given i n enclosed drawing t o connect a l l c a b l e armours to earth point with suitable nuts/bolts as given below. A) GI nuts/bolts of size 8x25mm with Two flat and one spring washer of 23set. B) GI nuts/bolts of size 12x40mm with two flat and one spring washer of 02set as per site incharge" | Location Box | 4.00 | 846.75 | 3,387 |
| 12 | "Installation of 230V Class B & Class C Surge Protection D e v i c e . T h i s includes transportation o f m a t e r i a l s t o site. Installation t o b e carried o u t a s p e r the direction o f Railway Engineer. Necessary copper wire for Power Wiring and connecting the earth to be supplied as part o f the schedule. All o t h e r miscellaneous materials required for installation shall be supplied by the contractor." | Numbers | 2.00 | 9,752.74 | 19,505.48 |
| 13 | Supply of 8-Channel Earth Leakage Detector as per RDSO Specifications RDSO/SPN/256/2002 or latest | Numbers | 4.00 | 1,10,759.06 | 4,43,036.24 |
| 14 | Supply o f S M R o f capacity 2 3 0 V AC/110V D C , 2 0 A a s p e r R D S O Specifications RDSO/SPN/165 /2012 Ver 3.0 or latest | Numbers | 47.00 | 58,730.08 | 27,60,313.76 |
| 15 | Supply of DC-DC Converter of Capacity 110V DC/24-40V, 5A a s p e r RDSO Specifications RDSO/SPN/165 /2012 Ver 3.0 or latest | Numbers | 49.00 | 18,095.3 | 8,86,669.7 |
| 16 | S u p p l y o f I n v e r t e r o f C a p a c i t y 110V D C / 2 3 0 V A C , 1 . 5 K V A a s p e r RDSO Specifications RDSO/SPN/165 /2012 Ver 3.0 or latest or IRS:S 82-92 | Numbers | 20.00 | 57,921.89 | 11,58,437.8 |
| 17 | Supply of Power Panel for IPS Room (using phynolic sheet 1200mm x 1200mm x 10mm and erecting i t u s i n g M S angles 25mm x 25mm x 6mm and fixing of meters, stabilizer and ammeter b y pass switches, H R C fuse blocks, P B T terminals 60mm c e n t r e and connecting t h e power equipments t o the power p a n e l a s per approved power diagram, in the power room.) | Numbers | 45.00 | 31,873.7 | 14,34,316.5 |
| 18 | "Supply o f Modular terminal block a s per R D S O specification N o 18/2004 o r latest w h i c h consists a s p e r following: a) 2 Conductor disconnect t y p e terminal block as per Model No wago 280-870 or similar - 6 Nos b ) End Plate type 280-374 suitable for disconnect terminal of Model No wago 280- 870 or similar - 1 No c) End Stop terminal block type as per model no wago 249-117 or similar - 2 Nos d) Shorting Links (16A) as per Model wago 280-402 or similar- 1 No" | Set | 90.00 | 772.74 | 69,546.6 |
| 19 | Supply of FUSE links of (400mA, 630mA, 1A, 1.6A, 2A, 4A, 6.3A & 10A) | Numbers | 20.00 | 61.74 | 1,234.8 |
| 20 | Installation o f 8-Channel E a r t h Leakage Detector. T h i s includes transportation of materials t o Site location a n d provision of c a b l e t r o u g h a r r a n g e m e n t s including c o n n e c t i o n t o t h e B R C e a r t h . Also includescarrying out of pre-commission checklist. | Numbers | 4.00 | 11,320 | 45,280 |
| 21 | Installation of Power Panel for IPS Room | Numbers | 45.00 | 7,246.46 | 3,26,090.7 |
| 22 | Commissioning of IPS, this schedule includes arrangement o f O E M engineer for checking the Installation and carrying out adjustments of IPS modules and submission of Pre- commissioning checklist | Set | 45.00 | 59,000 | 26,55,000 |
| 23 | Installation, wiring and testing of IPS as per RDSO Specification No. RDSO /SPN /165 or latest.This w o r k includes transporting the IPS from the Stores by loading without any damages and installation of the same at site. This also includes wiring of all modules, proper earthing of equipments and all other w o r k s c o n n e c t e d f o r t e s t i n g and commissioning o f t h e s a m e . Necessary p o w d e r e d c o a t e d A l u m i n i u m ladder arrangements including cable trench, pipes, bolts, and other accessories i s included in this schedule.[Earthing is not covered under this schedule] | Set | 45.00 | 77,160.07 | 34,72,203.15 |
| 24 | S u p p l y o f S w i t c h B o a r d cable, Fi n o l e x / D e l t r o n m a k e o r better 0.5mm/10Pairs, conforming to IRS/TC/24-91 cable | Metre | 1000.00 | 55.28 | 55,280 |
| 25 | Supply of UTP Cable /CAT6/6A cable ETL or UL or CE3P certified panduit or Systimax or R & M o r A M P o r M o l e x o r K r o n e O r D- LinkMakes | Metre | 500.00 | 34.73 | 17,365 |
| 26 | Supply a n d fixing o f 1 0 pair C T b o x and termination of cables | Numbers | 10.00 | 4,004.72 | 40,047.2 |
| 27 | Supply a n d fixing o f 2 0 pair C T b o x and termination of cables | Numbers | 15.00 | 4,761.16 | 71,417.4 |
| 28 | Supply and provision o f normal joint using Thermo shrink jointing kit (RDSO specs No TC/77/2012 ( R e v . 3 ) w i t h amendment N o . 1 & 2 o r l a t e s t . & j o i n t i n g k i t t o be inspected b y R D S O ) f o r 4 / 6 q u a d cable normal joint. The work includes excavation o f j o i n t p i t o f s i z e 1mX1.5mX1.5m and closing the same after completion o f cable j o i n t a s p e r t h e instruction o f Railway representative at site. | Numbers | 15.00 | 4,628.91 | 69,433.65 |
| 29 | S u p p l y a n d provision o f derivation joint c o m p l e t e f o r 6 Q u a d c a b l e s using thermoshrink jointing kit for LC's/stations | Numbers | 15.00 | 4,901.27 | 73,519.05 |
| 30 | Supply a n d installation o f 4 8 fi b r e Joint enclosure f o r armoured optical fibre cable c o n f o r m i n g to RDSO spec.RDSO/SPN/TC/68/2014 rev2.1 or latest | Numbers | 10.00 | 20,060 | 2,00,600 |
| 31 | Supply of RCC cable markers (Supply of RCC cable markers a s p e r drawing No.CSTE/CN/OFC/1. T h e lettering o n the cable marker shall be "SIG" / "TELE" / "OFC" a s p e r t h e i n s t r u c t i o n s o f Railway representative a t s i t e . ) as per drawing enclosed | Numbers | 135.00 | 262.65 | 35,457.75 |
| 32 | Preparation of Cement concrete for covering of G I Pipes/cables. Providing & L a y i n g in position c e m e n t c o n c r e t e of specified proportion i n c l u d i n g c o s t of cement, centering and shuttering with 1:3:6 composition 1 Cement: 3 S a n d : 6 grade s t o n e a g g r e g a t e 2 5 m m n o m i n a l size) (Cement, M-Sand, stone jelly of 25mm and a l l other m i s c materials required f o r the work should be supplied by Contractor). | cum | 250.00 | 9,361.46 | 23,40,365 |
| 33 | L a y i n g o f STP/OFC/Power C a b l e / switch board (10 pair/ 20 pair/50 pair) Cables in 1" P V C conduit/case caping a n d clamping on t h e wall/Roof tops/ Shelters w i t h suitable clamping a n d hose t o b e provided where e v e r b e n d s / c u r v e s ( P V C conduit/ Case capping and other accessories to be supplied by the contractor) | Metre | 1200.00 | 37.3 | 44,760 |
| 34 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. (Laying of cables is not included in this schedule) | Metre 11550.00 | — | 64.1 | 7,40,355 |
| 35 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 0.5 Mtrs and to a width of 0.3 Mtrs. (Laying of cables is not included in this schedule.) | Metre | 500.00 | 32.05 | 16,025 |
| 36 | Removing/breaking of existing RCC slabs on the Passenger Platform, trenching to a depth of 0 . 6 m t o accommodate the additional cables, replacing the slabs removed after the cables are laid and replastering with cement mortar, refilling the trench by ramming and consolidating it a s p e r t h e i n s t r u c t i o n s of Railway Representatives at site. (Laying of cables is not included in this schedule). | Metre | 50.00 | 314.41 | 15,720.5 |
| 37 | Breaking o f Platform concrete having 0.3 feet thickness - 0.5 feet thickness and to a width o f 0.3 Mtr using cutter machine and removal o f R C C s l a b s o n t h e Passenger Platform, trenching t o a depth o f 0 .6 m to a c c o m m o d a t e t h e a d d i t i o n a l cables, replacing the slabs removed after the cables are laid and replastering with cement mortar, refilling the trench by ramming and consolidating i t a s p e r t h e instructions of Railway Representatives at site. (Laying of cables is not included in this schedule). | Metre | 250.00 | 2,224.44 | 5,56,110 |
| 38 | Excavation of trench along route of existing c a b l e d u c t , o p e n i n g t h e s l a b s to a c c o m m o d a t e a d d i t i o n a l c a b l e laying, REPOSITIONING the slabs removed after the cables are laid and PLASTERING with cement mortar, and refilling the trench by ramming and consolidating it as per the instructions of Railway Representatives at site. (Laying of cables is not included in this schedule.)[Cement,M Sand and all other miscellaneous materials required f o r the work shall be supplied by the Contractor]. | Metre | 250.00 | 161.92 | 40,480 |
| 39 | Excavation of trench to a depth of 1 Mtr. for track crossing of cables, refilling of trench by ramming and consolidating it as per the instructions of Railway representative at site after laying o f DWC/RCC pipes. During excavation o f trench, i t h a s t o b e ensured that the excavated soil does not mix with the ballast available. T h e d e p t h o f 1m trench shall be from the bottom of sleepers for track crossings. Laying o f cables and DWC pipes is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not included in this schedule). | Metre | 75.00 | 385.45 | 28,908.75 |
| 40 | Provision of GI pipes (50/100mm dia) for cable laying with offset at both ends and with couplings over RCC bridges, drainage, culverts, and girder bridges. For RCC bridges, drainage, and culverts, the pipes shall be mounted on concrete masonry supports of size 300mm x 300mm x 300mm at an interval of 2 meters. For girder bridges, the pipes shall be fixed on suitable MS clamps at an interval of 2 meters. The ends of the pipes shall be closed with brick masonry abutments to ensure that no cable is exposed. The work shall be carried out as per the instructions of the Railway representative at the site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).Stone jelly (20/25mm size), bricks, sand, cement, MS angles, flats, bolts, nuts for manufacturing and fixing clamps, bricks, M sand, cement, and other miscellaneous materials for the work shall be supplied by the contractor. | Metre | 300.00 | 208.54 | 62,562 |
| 41 | Construction of Support for the GI pipes laid in RCC Box type bridges | Numbers | 1.00 | 367.41 | 367.41 |
| 42 | Provision o f G I pipes (50/100mm d i a ) for cable laying in hard rocky area with off sets a t both ends duly supported b y concrete blocks of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes s h a l l b e c l o s e d w i t h b r i c k masonry abutments work so that no cable is exposed, The work shall be carried o u t as p e r the instructions of Railway representative at site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).[Stone jelly of size 20/25mm, bricks, sand, cement, and all other miscellaneous materials required for t h e w o r k s h a l l be supplied by the Contractor]. | Metre | 300.00 | 182.87 | 54,861 |
| 43 | L a y i n g o f signaling/power/ telecommunication cables as per cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc.(Supply of cables is not included in this schedule). | Metre 53000.00 | — | 18.18 | 9,63,540 |
| 44 | "Refilling of cable trench 1m depth by 0.3m width throughout, with earth after laying of cables, a n d consolidating t h e t r e n c h by ramming and levelling." | Metre 11550.00 | — | 15.4 | 1,77,870 |
| 45 | "Refilling o f cable trench 0 . 5 m d e p t h by 0 . 3 m w i d t h throughout, w i t h e a r t h after laying of cables, and consolidating the trench by ramming and leveling." | Metre | 500.00 | 7.77 | 3,885 |
| 46 | "Digging of pit to a depth of 800mm of size 3 0 0 m m X 3 0 0 m m , c a s t i n g o f concrete foundation of size 300mmX300mmX300mm and Placing of RCC cable markers on top of t h e foundation a n d refilling t h e p i t and consolidating i t b y ramming. T h e cable markers shall b e provided a t a n interval of 2 0 Mtrs. within station limits a n d 5 0 Mtrs. outside station limits throughout t h e cable r o u t e , d i v e r s i o n s a n d a l s o a t every track/road crossing." | Numbers | 135.00 | 123.35 | 16,652.25 |
| 47 | Excavation o f cable c o i l p i t t o a s i z e of 1.5mx1.5m a n d d e p t h a s instructed by Railway representative at site, for coiling the cables in rear of relay rooms/ AFTC huts, apparatus c a s e s e t c . T h e w o r k includes coiling the underground cables and placing closely o n e layer o f country bricks o f size approx. 220mm x 100mm x 60mm breadth wise above the cables to cover all the cables in the cable pit, closing and consolidating the pit by ramming and levelling.[Country bricks of size 2 2 0 m m x 1 0 0 m m x 6 0 m m (approximately) shall be supplied by the Contractor]. | cum | 49.00 | 949.05 | 46,503.45 |
| 48 | " Ro a d crossing/ Tr a c k Crossing through Horizontal Drilling at approximately depth of 1.5 to 2m below the formation level of the earth including insertion of HDPE pipe/DWC pipe along with couplers, drawl of cable (or) direct drawl o f cables etc. (Note: T h e pilot used for HDD should be of sufficient size to suit insertion o f HDP E /DW C p i p e o f size 120mm (outer dia.) or direct drawl of three cables (Signalling/Power/Quad/OFC) or three nos.of 40mm d i a HDPE pipe o r any other combination a s directed b y t h e site engineer) ( Supply o f H D P E p i p e i s not covered in this schedule)" | Metre | 78.00 | 1,351.45 | 1,05,413.1 |
| 49 | Blowing/Drawing o f O F C cable/Power cable/Signalling c a b l e i n s i d e permanently solid lubricated HDPE Pipe already laid. This work includes necessary duct integrity test f o r s o l i d lubricated H D P E p i p e . ( This includes Transportation o f materials from nominated stores to site) | Metre | 3000.00 | 23.43 | 70,290 |
| 50 | Supply of Relay, Non-AC Immune, plug-in type , Style 'QN1',DC neutral line, 50V, 8F.8B contacts front and back contacts metal to carbon with plug board , retaining clip & connectors confirming to BRS:930, IRS:S 34 & IRS:S 23 or latest. The interlocking code for this unit shall be ABDEF. | Numbers | 10.00 | 4,484 | 44,840 |
| 51 | Supply o f Relay rack universal type a s per drg.No.S&T/ M F T / 2 9 1 w i t h scaffolding, POWDER COATED with stainless steel nuts a n d bolts f o r fixing t h e racks. Supporting angles, frame mounting triangle base with 'J' bolts and insulation o f required numbers complete t o suit QN1 / K-50 p r e wired tag blocks with suitable inner frames. a) 1 way | Numbers | 1.00 | 8,184.9 | 8,184.9 |
| 52 | Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d P o i n t control circuits, fixing o f plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring a n d termination as per approved circuit diagram a n d painting the particulars.[Wire P V C c o p p e r , 3 / 0 . 7 5 m m and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6 m m brass bolts a n d nuts, p a i n t s , s o l d e r i n g materials, resistors, condensers a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. a)Wiring of Signal/ point/ LC control circuit (up to 4 relays/Plug in type) | Set | 2.00 | 4,945.51 | 9,891.02 |
| 53 | Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d P o i n t control circuits, fixing o f plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring a n d termination as per approved circuit diagram a n d painting the particulars.[Wire P V C c o p p e r , 3 / 0 . 7 5 m m and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6 m m brass bolts a n d nuts, p a i n t s , s o l d e r i n g materials, resistors, condensers a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. c)Wiring of Signal/ Point/ L C control circuit (up to 12 relays/plug in type) | Set | 2.00 | 11,355.02 | 22,710.04 |
| 54 | Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d P o i n t control circuits, fixing o f plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring a n d termination as per approved circuit diagram a n d painting the particulars.[Wire P V C c o p p e r , 3 / 0 . 7 5 m m and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6 m m brass bolts a n d nuts, p a i n t s , s o l d e r i n g materials, resistors, condensers a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. d)Wiring of Signal/ Point/ L C control circuit (up to 20 relays/Plug in type) | Set | 3.00 | 13,597.41 | 40,792.23 |
| 55 | Erection o f Re l a y R a c k 1way/2way/4way with scaffolding suitably concreting tri-pod bases using J-bolts, fixing rack supporting of size 50x50x6mm o n t o t h e wall. Reel insulators are t o b e provided f o r insulating t h e r a c k f r o m t h e scaffolding & tri-pod bases.(Payment b a s e d o n n u m b e r of equivalent 1way relay racks) (per Unit = Per 1way Relay Rack) | Per Unit | 1.00 | 596.38 | 596.38 |
| 56 | Fixing of PBT terminal block/ PBT fuse block, rubber grommets, clamping of cables using teakwood cable clamps a n d base planks, termination of cables, provision of ND type fuses o f required capacities, provision of copper bus bar for supply terminals, wiring, provision of termination particulars diagram board using plywood of thickness 12mm - teakwood finish of size 1800mm x 1200mm with Aluminium grooved channel frame in the relay room. The blank spaces over the top of the cable termination rack shall be covered with phynolic sheet o f thickness 3 m m wherever required. T h e termination and cable core particulars shall b e painted o n t h e PVC/ nylon sleeves. T h e w ork also includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply o f PBT terminal blocks 25mm & 60mm centers and P B T Fu s e b l o c k s i s not covered in the schedule) [Wire P V C 3/0.75mm copper, brass bolts and nuts and washers, for fixing PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 50mm x 50mm for cable clamps, 25mmx 100mm for base planks, phynolic sheet 6 m m thick of size 1200mm x 1800mm with aluminium grooved channel f r a m e , p h y n o l i c sheet 3 m m thick, paint a n d a l l other miscellaneous materials shall be supplied by the Contractor]. a)Fixing of PBT terminal blocks (25mm/60mm centre) and termination (Per Unit = Per Terminal Block) | Per Unit | 2750.00 | 167.99 | 4,61,972.5 |
| 57 | Fixing of PBT terminal block/ PBT fuse block, rubber grommets, clamping of cables using teakwood cable clamps a n d base planks, termination of cables, provision of ND type fuses o f required capacities, provision of copper bus bar for supply terminals, wiring, provision of termination particulars diagram board using plywood of thickness 12mm - teakwood finish of size 1800mm x 1200mm with Aluminium grooved channel frame in the relay room. The blank spaces over the top of the cable termination rack shall be covered with phynolic sheet o f thickness 3 m m wherever required. T h e termination and cable core particulars shall b e painted o n t h e PVC/ nylon sleeves. T h e w ork also includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply o f PBT terminal blocks 25mm & 60mm centers and P B T Fu s e b l o c k s i s not covered in the schedule) [Wire P V C 3/0.75mm copper, brass bolts and nuts and washers, for fixing PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 50mm x 50mm for cable clamps, 25mmx 100mm for base planks, phynolic sheet 6 m m thick of size 1200mm x 1800mm with aluminium grooved channel f r a m e , p h y n o l i c sheet 3 m m thick, paint a n d a l l other miscellaneous materials shall be supplied by the Contractor]. b)Termination using PBT fuse block i n cable termination rack (Per Unit = Per Fuse Block) | Per Unit | 365.00 | 201.27 | 73,463.55 |
| 58 | Fixing o f additional plug boards, 5 0 ways terminal b l o c k s a n d w i r i n g o f additional relays a s per the approved circuit diagram using wire PVC 16/0.2mm copper. Additional wire supporting tray with cover made of PVC shall b e provided wherever required. Alterations t o Re l a y particulars shall be incorporated in the relay Index board.(Supply o f r e l a y s , p l u g boards, connectors and retaining clips a n d 5 0 way terminal boards i s n o t covere d i n this schedule).[Wire PVC 16/0.2mm copper, 2 BA terminals, teakwood plank 25mm thick for fixing r e s i s t o r s a n d condensers, soldering materials, bunching thread, wire wound resistance, c o n d e n s e r , wire supporting tray with cover o f suitable size made o f PVC, paint, varnish a n d a l l other miscellaneousmaterials r e q u i r e d f o r the work shall be supplied by the Contractor ] | Per Relay | 35.00 | 726.5 | 25,427.5 |
| 59 | Carrying o u t alterations t o t h e existing relays in the relay racks/apparatus cases as per the approved circuit diagram using wire P V C 16/0.2mm copper. T h e w ork includes p a i n t i n g alterations a n d r e l e a s i n g the unwanted wires carefully without disturbing the existing wiring.[Wire P V C 16/0.2mm c o p p e r , soldering materials, bunching t h r e a d s , condensers, resistances and teakwood plank for fixing them and all other miscellaneous materials required f o r the work shall be supplied by the Contractor]. | Per Relay | 30.00 | 695.67 | 20,870.1 |
| 60 | Supply of Handheld True RMS Multi Meter, as per Technical specification | Numbers | 8.00 | 23,192.34 | 1,85,538.72 |
| 61 | Supply of Handheld True RMS clamp Meter, as per Technical specification | Numbers | 2.00 | 33,510.29 | 67,020.58 |
| 62 | S u p p l y o f H a n d h e l d D i g i t a l Insulation Re s i s t a n c e Te s t e r , a s p e r Technical specification | Numbers | 2.00 | 51,165.02 | 1,02,330.04 |
| 63 | S u p p l y o f O T D R ( m i n i ) w i t h standard accessories f o r 1310/1550nm w i t h all standard accessories as per TEC specification GR/OTD-02/02 J a n 2 0 0 5 or latest, ( this item should h a v e valid TEC approval certificate) as per Technical specification | Numbers | 1.00 | 3,07,856.22 | 3,07,856.22 |
| 64 | Supply o f SPD Life tester, designed for on- s i t e testing o f s u r g e protective devices (SPD). It shall indicate the health status of GDT/ MOV based SPD of voltage range upto 1000V. It shall indicate the status of SPD by measuring its electrical parameters. | Numbers | 1.00 | 1,20,729.41 | 1,20,729.41 |
| 65 | Supply of Digital Insulation tester (Megger) 50V-500V/1000 mega ohm battery operated with all complete accessories, as per Technical specification | Numbers | 6.00 | 11,844.52 | 71,067.12 |
| 66 | S u p p l y o f C a b l e R o u t e Tr a c e r a s per Technical specification | Numbers | 2.00 | 5,78,788.99 | 11,57,577.98 |
| 67 | Supply of Portable Cable Fault Locator as per Technical specification | Numbers | 2.00 | 1,86,694.53 | 3,73,389.06 |
| 68 | Supply of Digital Earth clamp Tester as per Technical specification | Numbers | 2.00 | 71,129.79 | 1,42,259.58 |
| 69 | Supply of Transmission measuring set (TMS) with accessories as per IRS Spec No. IRS:TC 43-87 o r latest, a s p e r Technical specification | Numbers | 2.00 | 57,699.4 | 1,15,398.8 |
| 70 | S u p p l y o f Rodometer a s p e r Technical specification | Numbers | 4.00 | 4,252.24 | 17,008.96 |
| 71 | Supply o f Double walled corrugated pipe - 103.5mm i n n e r d i a & 1 2 0 m m o u t e r dia c o n f o r m i n g t o s p e c i fi c a t i o n N o . IS 14930(Part 2 ) : 2 0 0 1 w ith o n e coupler for e v e r y 6 m o f p i p e a s p e r Technical specification | Metre 11650.00 | — | 365.19 | 42,54,463.5 |
| 72 | S u p p l y a n d In s ta lla t io n o f Wall/Rack mountable 4 8 Fibre management system ( F M S ) conforming t o RDSO/SPN/TC- 37/2000(rev-3 amdt-1 o r latest similar to COMMSCOPE m ak e o r better, suitable for splicing and front patching 48F cable with all accessories and terminating the optical fibre cable with splicing and front patching in FMS in the Location Box. This includes Supply and Provision of Wooden Plank, L clamps and 4 nos of Patch cords of required l e n g t h (All other materials required for splicing are to be supplied by contractor) | Numbers | 4.00 | 32,885.01 | 1,31,540.04 |
| 73 | Supply of Track Feed Resistance | Numbers | 2.00 | 287.77 | 575.54 |
| 74 | Supply of gauge Tie Plate Insulation | Set | 4.00 | 210.72 | 842.88 |
| 75 | Supply of E-Type Locks | Numbers | 20.00 | 1,234.88 | 24,697.6 |
| 76 | Supply of EWS Locks | Numbers | 4.00 | 302.48 | 1,209.92 |
| 77 | Supply and wiring of LEDs with resistance and fixing on the cable termination rack for indicating "FUSE BLOWN OUT" for each circuit. The LEDs and resistances shall be fixed on a phynolic sheet 50mm width and 3mm thick. The phynolic sheet shall be fixed by the side of the corresponding Fuse Blocks. Separate switch shall be provided for each circuit.[LEDs 10mm, holders, resistance, switch, phynolic sheet, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 20.00 | 60.68 | 1,213.6 |
| 78 | Supply o f 4 wire DTMF based w a y station e q u i p m e n t c o m p l e t e a s p e r RDSO specification No.IRS.TC@45<47@93 a n d 4 wire control telephone with audio visual indication and r e s e t b u t t o n fi t t e d on telephone conforming to specification No.IRS-TC@45&47@97 or latest. | Set | 30.00 | 9,086 | 2,72,580 |
| 79 | Manufacture and supply of teak wood tool box of size 1000X750X100mm made of 25mm thick teak wood persplex sheet fronted 6mm (Colourless) fixed on the wall at a convenient location as instructed by Railway representative at site. The board should have provision of pad lock and locking arrangements and shall be equipped with the following tools[reputed make]: a. Digital Mulltimeter similar to Model No. Rish Multi 18S with suitable carrying case and test probes. b. Centre zero ammeter 30-0-30 Amps - 1 No. c. Screw drivers of different types and sizes with common handle - 1 set d. Spanner double ended 33mm - 1 No. e. Spanners double ended 3/8x1/2" - 1 No. f. Spanners double ended 5/8x3/4" - 1 No. g. Spanners double ended 7/8x1" - 1 No. h. Hammer 1 1/2 lbs ball pane - 1 No. i. Hacksaw frame - 1 No. j. Adjustable screw spanner 12" - 1 No. k. Insulated cutting pliers- 1 No. l. Insulated nose plier- 1 No. m. Electric soldering iron 230V 60W Soldron/Philips make - 1 No. n. Electric soldering iron 110V 35W Soldron/Philips make - 1 No. o. Megger 500V/ 500Mohms. with Probe- 1 No. The above tools shall be purchased from Reputed manufacturers only in consultation with the Railway representative at site. [Teak wood tool b o x made o f 25mm teak w o o d plank, perspex sheet, a l l t h e tools m e n t i o n e d a b o v e , p a d l o c k a n d other miscellaneous items shall be supplied by the Contractor]. | Set | 2.00 | 29,185.6 | 58,371.2 |
| 80 | Supply of ND Fuse of various capacities (Per unit=Per fuse) | Per Unit | 365.00 | 37.74 | 13,775.1 |
| 81 | "Supply and provision of Rubber mat of not less than 6mm thick and with an insulation t o withstand 650VAC, o n t h e floor o f relay room etc a t places a s indicated b y railway representative at site." | Square Foot | 1240.00 | 144.86 | 1,79,626.4 |
| 82 | E x c a v a t i o n o f p i t , e r e c t i o n o f cable termination boxes on rails and concreting as per Drg. No.SG/CN/02/8, drilling of suitable holes in the box, fixing of 2 Nos. of GI pipes 32mm dia and 300mm long at the bottom with clamp nuts - 12 mm thick, one at the inner side and another at the outer side for each pipe for cable entry and one GI pipe 150mm long 32mm dia for drawl of jumper wires for Point machines etc., fixing of hardwood plank 37mm thick on the bottom, provision of one EWS lock, and painting the boxes inside and outside with o n e c o a t of red-oxide a n d t w o c o a t s of aluminium paints. | Numbers | 4.00 | 5,029.69 | 20,118.76 |
| 83 | Installation of combined type point machine-IRS type and connecting all ground connections including wiring and termination in p o i n t m a c h i n e and interconnections between point machine and CT box through PVC h o s e p i p e with 3/0.75mm and 7/1.40mm copper wire and painting. This work includes provision of insulation to stretcher bars, throw b a r lug and "D" bracket wherever required, cutting of notches on the point machines covers to suit crank handle configuration.(Combined type point machine with ground connection, uninsulated stretcher bar, throw bar lug and 'D' brackets will be supplied by Railways.[All types of insulations connected to point work, coal bengal, all type of bolts and nuts, washers spring/flat w i r e PVC 7/1.4mm copper, P V C h o p e p i p e , paints, PVC/nylon sleeves and all other miscellaneous materials required f o r the work shall be supplied by the Contractor]. | Numbers | 4.00 | 16,383.88 | 65,535.52 |
| 84 | "Excavation o f p i t a n d casting concrete foundation a s p e r D r g , No.SG/CN/02/10 u s i n g metallic templates, f o r erection of g r o u n d t y p e c o l o u r l i g h t s h u n t signal. [Foundation bolts and nuts, cement, M sand, stone jelly o f size 20/25mm a n d all other miscellaneous materials for the work shall be supplied by the Contractor]." | Numbers | 3.00 | 4,645.17 | 13,935.51 |
| 85 | "Erection o f G r o u n d t y p e s h u n t signal complete including surface base, signal pole, LED a s p e c t s / l e n s e s , b u l b s with holders (whichever i s applicable), fixing of lens guards, number plate, termination of tail cables, wiring o f signal unit w ith PVC wire 3/0.75mm copper, provision o f EWS locks and painting of one coat o f red oxide and two coats of Aluminium/ enamel paint. ( S u p p l y o f G r o u n d t y p e s h u n t signal complete including surface base, signal pole, LED aspects, holder, bulbs, and lenses is not covered i n this schedule).[Wire PVC 3/0.75mm copper, lens guards, E W S locks, Enameled number plates, bolts a n d nuts, lead wool, paints and all other miscellaneous materials shall be supplied by the Contractor]." | Numbers | 3.00 | 3,170.44 | 9,511.32 |
| 86 | Fixing of Offset brackets using 'U' bolts and nuts, erection o f Post type shunt Signals, termination o f tail cables a n d wiring using w i r e P V C 3/0.75mm copper, provision of EWS lock and painting o f o n e coat o f red- "oxide and two coats of aluminium/ enameled paint. The work also includes drilling suitable holes o n the C L S post and provision o f a through bolt with nut to prevent the Off-setbracket from slipping down." | Numbers | 2.00 | 2,306.03 | 4,612.06 |
| 87 | Provision of DC Single/ Double rail track circuit to suit RE/ Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLD boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 No's for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, 'B' type choke' and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLD boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this schedule.)(Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, 'B' type choke, track relays, un-charged secondary cells (2V - 80AH), TLD boxes with stumps,2cX2.5 sq.mm cable, is not covered in this schedule). a)Provision of track circuit in RE/Non RE area (point zone) | Numbers | 1.00 | 8,914.5 | 8,914.5 |
| 88 | Provision of DC Single/ Double rail track circuit to suit RE/ Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLD boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 No's for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, 'B' type choke' and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLD boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this schedule.)(Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, 'B' type choke, track relays, un-charged secondary cells (2V - 80AH), TLD boxes with stumps,2cX2.5 sq.mm cable, is not covered in this schedule). b)Provision of track circuit in RE/Non RE area (other than point zone) | Numbers | 4.00 | 7,145.44 | 28,581.76 |
| 89 | Alteration t o existing D C Track Circuits to suit RE/Non R E standard a s p e r approved signaling plan. This work includes provision o f double bonding a n d parallel jumpers, provision o f b o n d w i r e c l i p s , wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track l e a d c o n n e c t i o n s wherever necessary using 2c x 2.5 sq.mm cable. a)Alteration to existing track circuits at feed end | Numbers | 5.00 | 4,234.65 | 21,173.25 |
| 90 | Alteration t o existing D C Track Circuits to suit RE/Non R E standard a s p e r approved signaling plan. This work includes provision o f double bonding a n d parallel jumpers, provision o f b o n d w i r e c l i p s , wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track l e a d c o n n e c t i o n s wherever necessary using 2c x 2.5 sq.mm cable b)Alteration t o existing t r a c k circuits at relay end | Numbers | 5.00 | 3,850.31 | 19,251.55 |
| 91 | E x c a v a t i o n o f p i t , c a s t i n g concrete foundation and erection o f apparatus case f u l l s i z e a s p e r D r g . No.SG/CN/02/6 and fixing of 2 Nos. of 'E' type locks, one for the front door a n d another f o r t h e bac k door, fixing o f one hard wood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red- oxide and two coats of aluminium paints. (Supply of apparatus case is not included in this schedule).[Foundation bolts & nuts, 'E' type locks, cement, M sand, stone jelly of size 20/25 mm, hardwood plank of 37mm thick, paints, varnish, fixing bolts & nuts and a l l other miscellaneous materials required f o r thework shall be supplied by the Contractor.] | Numbers | 8.00 | 11,333.1 | 90,664.8 |
| 92 | Fixing of E-Type Lock | Numbers | 20.00 | 308.03 | 6,160.6 |
| 93 | " E x c a v a t i o n o f pit, casting concrete foundation and erection o f apparatus case half size as per Drg, No.SG/CN/02/7, fixing o n e ' E ' t y p e l o c k f o r t h e front d o o r and latching arrangement for the back door, and fixing o f o n e hardwood s h e l f plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts and nuts, cement, 'E' type locks, M sand, stone jelly of size 20/25mm,37mm hard wood planks, latching ""arrangements, paints, varnish, fixing bolts & nuts a n d all other miscellaneous materials required for t h e w o r k s h a l l b e s u p p l i e d by the Contractor]""" | Numbers | 4.00 | 8,787.04 | 35,148.16 |
| 94 | Excavation of pit in and around the existing l o c a t i o n b o x e s v e r y c a r e f u l l y without damaging t h e working cables a n d shifting and turning the location boxes to clear of the infringement a s instructed b y the Railway representative a t s i t e . T h e work includes ensuring the safety of the signaling system, releasing t h e cable coils t o give a c c e s s for shifting/turning t h e location boxes. Necessary masonry work and earth work in and around t h e location boxes to the required level shall be done as instructed by the Railway representative at site. If the existing earth connections to the location boxes are disturbed, the earth wires shall be properly re-connected. a) Shifting of apparatus case (full) | Numbers | 4.00 | 5,348.81 | 21,395.24 |
| 95 | Termination o f new main/tail cables o n the existing terminals/ fuse blocks in apparatus c a s e s / batte ry b o x e s / C T b o x e s / cable termination racks a s p e r approved circuit diagram. The terminal particulars are to be r e p a in t e d /corrected o n t h e d o o r s of apparatus c a s e s / b a t t e r y b o x e s / cable termination boxes and FTOT index board as instructed by Railway representative at site. This work includes closing the opening created f o r e n t r y o f n e w c a b l e s i n the apparatus cases w ith masonry brick work a n d sealing t h e bottom o f t h e apparatus cases/ cable termination racks w ith cable compound.[Paints, wire PVC 3/0.75mm and 16/0.2mm copper, s e a l i n g compound, b r i c k s , cement, M sand and all other required miscellaneous materials shall be supplied b y the contractor].(Per Unit = Per Terminal block) | Per Unit | 700.00 | 73.59 | 51,513 |
| 96 | Termination o f m a i n , t a i l , Signaling and p o w e r c a b l e s a n d i n t e r n a l w i r i n g on terminal/ f u s e b l o c k s i n n e w apparatus cases, cable termination boxes and i n gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base p l a n k , fi x i n g o f Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each a p p a r a t u s case, varnishing all teakwood i t e m s , fi x i n g of terminals/ fuse blocks o n t h e terminal b o a r d , d r i l l i n g of necessary holes, termination o f cables, wiring, identification of cables using aluminium tags with letters punched neatly, as p e r approved circuit d i a g r a m a n d cable plan, p a i n t i n g of particulars on sleeves andalso o n the inner side o f the doors of apparatus cases. After terminations are "over, the side openings of apparatus case foundation shall b e closed with brick work, cement plastered, the inter- space filled with M sand u p t o base level and the bottom surface shall be sealed with sealing compound.(Supply of PBT terminals and Fuse blocks is not covered i n this schedule)." a)Termination on 25/60mm PBT terminals (new location)(Phynolic sheet)(Per Unit = Per Terminal block) | Per Unit | 2200.00 | 172.14 | 3,78,708 |
| 97 | Termination o f m a i n , t a i l , Signaling and p o w e r c a b l e s a n d i n t e r n a l w i r i n g on terminal/ f u s e b l o c k s i n n e w apparatus cases, cable termination boxes and i n gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base p l a n k , fi x i n g o f Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each a p p a r a t u s case, varnishing all teakwood i t e m s , fi x i n g of terminals/ fuse blocks o n t h e terminal b o a r d , d r i l l i n g of necessary holes, termination o f cables, wiring, identification of cables using aluminium tags with letters punched neatly, as p e r approved circuit d i a g r a m a n d cable plan, p a i n t i n g of particulars on sleeves andalso o n the inner side o f the doors of apparatus cases. After terminations are "over, the side openings of apparatus case foundation shall b e closed with brick work, cement plastered, the inter- space filled with M sand u p t o base level and the bottom surface shall be sealed with sealing compound.(Supply of PBT terminals and Fuse blocks is not covered i n this schedule)." b)Termination on PBT fuse block (new location) (Phynolic sheet)(Per Unit = Per Fuse block) | Per Unit | 345.00 | 209.93 | 72,425.85 |
| 98 | Termination o f m a i n , t a i l , Signaling and power cables a n d internal wiring b y fixing additional terminals/ f u s e b l o c k s o n the existing terminal boards of apparatus cases, c a b l e termination b o x e s e t c . T h e work includes fixing of all new cables by teakwood clamp o n teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, o n t h e existing terminal boards, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as p e r approved circuit d i a g r a m a n d cable plan, p a i n t i n g of particulars on sleeves and also on the inner side o f the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall b e closed with brick work, cement plastered, the inter- space filled with M sand u p t o base level and the bottom surface shall be sealed with sealing compound. a)Termination o f cables o n 2 5 / 6 0 m m PBT terminals (existing location)(Per Unit = Per Terminal block) | Per Unit | 300.00 | 151.09 | 45,327 |
| 99 | Termination o f m a i n , t a i l , Signaling and power cables a n d internal wiring b y fixing additional terminals/ f u s e b l o c k s o n the existing terminal boards of apparatus cases, c a b l e termination b o x e s e t c . T h e work includes fixing of all new cables by teakwood clamp o n teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, o n t h e existing terminal boards, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as p e r approved circuit d i a g r a m a n d cable plan, p a i n t i n g of particulars on sleeves and also on the inner side o f the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall b e closed with brick work, cement plastered, the inter- space filled with M sand u p t o base level and the bottom surface shall be sealed with sealing compound. b)Termination o f cables o n P B T f u s e block (existing location)(Per Unit = Per Fuse block) | Per Unit | 270.00 | 188.86 | 50,992.2 |
| 100 | Installation of charged secondary cells of the following capacities in apparatus cases, connecting them with strips, wiring with wire PVC 3/0.75mm copper and termination. This work also includes charging of cells through reputed agencies. The details of the batteries shall be written on the inside of the doors of the apparatus cases.(Supply of secondary cells is not included in this schedule).[Wire PVC 3/0.75mm copper, connecting strips, paint a n d a l l other miscellaneous materials required for the work shall be supplied by the Contractor]. b)Installation of 2V- 40/80AH cells in apparatus cases(Per Unit = Per Cell) | Per Unit | 16.00 | 491.59 | 7,865.44 |
| 101 | Installation of DTMF equipment | Set | 30.00 | 5,339.1 | 1,60,173 |
| 102 | Fixing o f E KT instrument with (or) without c r a n k h a n d l e o r o n suitable fixture s at station/apparatus c a s e , p r o v i s i o n of economiser push switch with locking facility, w i r i n g w i t h w i r e P V C 16/0.2mm copper, provision of teakwood terminal box covered with decolum along with locking facility and painting.(Supply of electric key transmitter and crank handles i s n o t covered i n this schedule). [wire P V C 16/0.2mm copper, w i r e wound resistance, decolum covered terminal box with locking facility b y using 2 5 m m thick teakwood, b o l t s a n d nuts, paints, push switches, padlocks a n d other miscellaneous materials required f o r this work shall be supplied by the contractor]. | Numbers | 2.00 | 5,445.94 | 10,891.88 |
| 103 | Laying o f DWC/Split D W C Pipes f o r Track Crossing/Road Cutting/Trenches | Metre 12450.00 | — | 42.46 | 5,28,627 |
| 104 | Releasing of existing apparatus cases (Full/ Half/ Quarter size) without damage after releasing the shelf planks, Terminal blocks, Fuse Blocks, Terminal Boards, Relays o f all t y p e s E K T s , S e c o n d a r y Cells, power equipments, ' E ' t y p e l o c k s , e t c . , and breaking t h e concrete foundation. After releasing, the resultant pits are to be closed and consolidated by ramming and levelling. The released materials shall b e accounted a n d stacked a t a place a s instructed by Railway representative at site. | Numbers | 280.00 | 3,006.71 | 8,41,878.8 |
| 105 | Dismantling and releasing o f existing Point m a c h i n e s ( a l l t y p e s ) i n c l u d i n g ground connections and other accessories available c o m p l e t e w i t h o u t a n y d a m a g e t o the gadgets, accounting a n d stacking them neatly a t a place a s instructed b y Railway representative at site. | Numbers | 1.00 | 2,698.69 | 2,698.69 |
| 106 | "Releasing o f existing ground t y p e shunt signals along with surface base, signal post e t c c a r e f u l l y w i t h o u t a n y damage, accounting a n d stacking them neatly a t a p l a c e a s instructed b y Railway representative a t s i t e . T h e w o r k also includes breaking and removal o f concrete foundation and refilling o f the resultant pit by ramming and levelling." | Numbers | 2.00 | 2,196.41 | 4,392.82 |
| 107 | Survey o f Cable Route a n d Preparation of Cable Route Plan | Kilometre | 10.00 | 716.01 | 7,160.1 |
| 108 | Transportation o f Signalling materials by r o a d a s p e r t h e instructions o f Railway representative a t s i t e . T h e w o r k also includes l o a d i n g a n d unloading o f the materials a)Transportation o f Signalling materials upto 100kms | MT-Km | 700.00 | 22.75 | 15,925 |
| 109 | Transportation of Signalling materials more than 100km | MT-Km 32000.00 | — | 13.91 | 4,45,120 |
| 110 | Engaging mechanical excavators like JCB or other machineries for regarding and levelling the formation, dismantling any infringing structures, clearing and removing debris etc., w i t h a l l l e a d s a n d l i f t s etc., complete and a s p e r t h e instruction of Railway representative at site. | Hour | 100.00 | 1,202.5 | 1,20,250 |
| Schedule total | ₹3,17,25,370.25 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC2022withACS1to11.pdf
ATTACHMENT
45LClistforIPSfortender.pdf
ATTACHMENT
MIIGazzette.pdf
ATTACHMENT
tenderdocumentRE.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .