| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 CrAccepted-AOC 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹3.5 Cr | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹3.6 Cr+₹13.1 L (3.72%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹3.6 Cr+₹13.1 L (3.72%) | L2 | Rejected-Finance Being other than lowest bidder |
| 3 | L3₹3.7 Cr+₹13.3 L (3.77%)Rejected-Finance I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | ₹3.7 Cr+₹13.3 L (3.77%) | L3 | Rejected-Finance Being other than lowest bidder |
| 4 | L4₹4.1 Cr+₹62.1 L (17.7%)Rejected-Finance | ₹4.1 Cr+₹62.1 L (17.7%) | L4 | Rejected-Finance Being other than lowest bidder |
Tender Value
₹3.8 Cr
EMD Value
₹4.5 L
Closing Date
3 Oct 2022, 6:00 pmClosed
CE AF Udhampur
Chief Engineer Air Force Udhampur Zone Udhampur Jammu and Kashmir
PROVISION OF COMMERCIAL POWER SUPPLY AND OTHER ASSOCIATED WORKS SERVICES FOR IPSS AT AIRFORCE STATION SRINAGAR
2022_MES_548305_1
CEAFU-07/2022-23
Open Tender
Miscellaneous Works
Item Rate
608 days
Srinagar
As per tender documents and as per policy in vogue
9 documents required · 9 mandatory
₹2,000
GE AF Srinagar
₹4.5 L
Yes
14 Nov 2022
29 Aug 2022
5 Oct 2022
29 Aug 2022
3 Oct 2022
19 Sept 2022
Amount
SCHEDULE 'A' PART-I FOR REPAIR TO BUILDING WORK:
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises, complete all as specified and as directed by Engineer-in-Charge.
Demolition of unreinforced cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) and removal the debrises from the site premises complete all as specifed and as directed by Engineer-in-Charge.
M&L for 25mm thick PCC 1:2:4 type B-0 using 12.50 mm graded crushed stone aggregate as in sub base for laying floor finishes.complete all as specifed and as directed by Engineer-in-Charge.
M & L vitrified ceramic tiles, (light shade) 10mm thick square /rectangular polished, area of each tiles not exceeding 0.36 sqm, as in floors, etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colours of tiles including 15 mm thick screed bed and bedding layer in CM 1:6 for laying floor finishes complete all as specified and directed.all as specified and directed.
M&L for 450mm x 300mm x 7mm thick coloured glazed ceramic tiles, as in vertical surfaces such as dado, skirting and the like, set and jointed in neat cement slurry and pointed with white or coloured cement mixed with pigments. (Note: Any disturbed surfaces shall be matched w/o any extra cost to the govt) including 10mm thck rendering below tile in cement mortar 1:4 complete all as specified & directed by Engineer-in-charge.
Demolition cement concrete (unreinforced) of any descriptions, and in any positions, including removal of debrises complete all as specified and directed.
M&L Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregates as in sub base, foundation, filling and mass concrete, complete all as specified and as directed by Engineer-in-Charge. Qty: Bldg work-0.10 Cum and Security fencing - 7.00 Cum and External Electrification work - 8.50 Cum
Material and labour for Brickwork with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and as directed. Qty: Bldg work-14.55 Cum and Security fencing - 35.00 Cum
Brickwork with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed.
Dismantling wall/floor and ceiling boards (fibre, pulp, inlsulation, blankets, etc) any thickness including fillets, covered fillets and existing wiring complete all as specified and as directed
Dismantling boarding, any description, fixed in any position with nails, in any position complete all as specified and as directed
-BLANK-
Provn of wooden panelling on vertical surface of wall using following specifications including taking down old wooden panelling complete all as specified and directed:- (a) S&F 2nd class hard wood wooden gutties of size 25mmx25mmx 200mm depth fixed in wall by making holes in brick wall and making good in cement mortar 1:3 complete all as specified and directed. (b) S&F horizontal & vertical runner 2nd class soft wood (Kail) at 120cm c/c both ways of sectional area exc. 13 Sqm and n. exc 25 Sqm clean sawn treated with two coats of creoste oil. (c) S&F 1st class soft wood (Deodar) boarding 10mm to 12mm thick as in wall panelling planed one side, wrought and other side clean sawn and applying two coats of good quality varnish on plain surfaces over a coat of primer and fixed with screws/nails on wooden runners. (d) S&F 1st class soft wood (Deodar) decorative breading 40mm wide on top surface of wall panelling including two coats of varnish.
M&L French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on new works with two or more coats complete all as specified and as directed.
M&L for GI clip in perforated 1.8 mm dia false ceiling system with tile (600mm x 600mm) manufactured out of 0.50mm. These tiles shall have square edges/bevelled edges. Two sides of each tile are raised and piped and stopped to ensure positive engagement into the spring clip in profile, yet allow for demounting of individual tiles, The rigid suspension system consists of rows of 0.5mm galvanized 100 to 120 gsm/Sqm steel clip-in profiles of size 38mm x 20mm and installed at 600mm c/c spacing to support the tiles, clip-in profiles are suspended and jointed from galvanized steel C channels of size 10mm x 38mm x 10mm with hold on clamps. Suspension angles are suspended from the roof structure by GI ceiling brackets and joint to the C channels, The tiles are held in place by pressure clips. In the flexible system the hanger and suspension clip replace the suspension angle. wall angles or edge profiles are of size 24mm x 24mm and 0.4mm thick with matching the colour with tiles complete all as specified and as directed. Make : Armstrong/Hunter Douglus/HE Steel/Saint Gobin / Durlum
Cutting openings, through brick walls built in cement mortar for door, window and other openings or enlarging existing openings, converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m complete all as specified and as directed.
Forming jambs, etc.in Cement mortar 1:6 to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete all as specified and directed.
Making good in cement mortar 1:4 under cills or over arches, lintels and bressummers, including allpinning when necessary complete all as specified and directed bt Engineer-in-charge.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 Sqm but not exc 4.00 Sqm complete all as specified and directed bt Engineer-in-charge.
Taking down chowkats or frames including shutter (without taking off shutters from the frame) area n exc. 1.5 Sqm each , Complete complete all as specified & directed by Engineer-in-charge.
S&F powder coated anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.) hinge type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed by Engineer-in-charge.
Plain Sheet glass 4.00 mm thick, ordinary quality and glazing with oil pane putty in squares not exceeding 0.5 Sq. mm in each pane, complete, complete all as specified and as directed.
M&L for powder coated anodised aluminium grills with 50mm x 75mm gap and 8mm thickness of grill for windows and ventilators, complete all as specified and directed by Engineer-in-charge.
Re-fixing in the same opening of Chowkhats or frames exc 1.50 sqm but n exc 4.00 sqm each without takingoff shutter from the frame complete all as specified and directed by Engineer-in-charge.
M&L for Cutting out bricks, forming toothing for, and bonding new into old work including value of new materials entering old walls and jointing and pointing (measured on vertical face in contact with old wall only) complete all as specified and directed by Engineer-in-charge.
S&F for powder coated aluminium anodised frame for doors, windows, sliding window, ventilators with one or more rebates, doors shutters of hollow rectangular/ square sections including aluminum hinges 100 mm long with powder coated jointing cleats for fixing complete all as specified and as directed.
S&F aluminum powder coated door shutters,aluminum section minimum weighing 1.10kg/m including necessary joining cleats,cleats glazing clips, rubber neoprene packing,handles two numbers in each door, hinges, anodised aluminum snap beading screws etc complete all as specified complete all as specified and directed by Engineer-in-Charge.
S&F for Aluminum, anodized, barrel tower bolts, ISI Marked, of extruded section 200 mm long, complete all as specified and directed.
S&F for Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty, complete all as specified and dirceted.
S&F brass mortice lock four levers, vetrical type size 100mm or above in old or new position including escutcheon plates and two keys complete all as directed by Engineer-in-charge
M&L for Plain Sheet glass 5.50 mm thick, ordinary quality and glazing with oil pane putty in squares exceeding 0.5 Sq. mm in each pane complete, complete all as specified and as directed.
S&F aluminum powder coated frame/sections for doors, partition and glass shelf with one or double groove including joining cleat, glazing clips and aluminum snap beading screws etc. complete all as specified.
S&F 5mm thick plain colour PVC sheet in strips & channel feathered at the edges for fixing on Solid PVC Wall Lining, Insulated PVC Wall Lining, and Solid PVC Partitions inclusive of Solvent Cement and fixing at site. complete all as specified and directed.
Holes drilled up to 12mm dia (and countersunk, if required), having depth of holes exceeding 12mm but not exceeding 25mm complete as directed by the Engineer-in-chgarge.
M&L for Collapsible steel gates, top hung, consisting for channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete complete all as specified and directed.
M&L Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe- 290 Gde E-165. complete all as specified and as directed
M&L Mild steel Fe-290 (Gde-E-165) round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for preparation of new steel or iron surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (any tint) over a coat of red oxide primer complete all as specified and as directed. Qty: Bldg work-25.90 Sqm and Security fencing - 53.00 Sqm
Taking down cement plaster on brick/concrete surfaces etc including racking out joints, hacking for keys and scrubbing down with water etc and removing all debris to a distance exc 50 mtr but not exc 100 mtrs, complete all as specified and directed by Engineer-in-charge.
M&L for 5 mm thick rendering in cement mortar 1:3 on fair faces of brick/concrete surfaces of ceiling including finishing the surfaces even and smooth (without using extra cement), complete all as specified and as directed.
M&L for 15mm thick rendering in cement mortar 1:6 on fair faces of brick/concrete surfaces of walls including finishing the surfaces even and smooth (without using extra cement), complete all as specified and as directed.
M&L for preperation of new concrete /plastered surface of wall, of any description, and applying 3mm thick wall care putty and two coats of distemper oil emulsion over a coat of primer complete all as specified and as directed
M&L for preperation of new concrete /plastered surface of ceiling, of any description, and applying 3mm thick wall care putty and two coats of distemper oil emulsion over a coat of primer complete all as specified and as directed
M&L for preperation of old decorated concrete /plastered surface of wall including complete removal of existing treatment of any description, and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and as directed
M&L for preparation of new wood or wooden based surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (any tint) over a coat of pink primer complete all as specified and as directed.
SCHEDULE 'A' PART-II FOR SECURITY FENCING WORK
M&L for plain cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregates as in sub base, foundation, filling and mass concrete, complete all as specified and as directed by Engineer-in-Charge. Qty: Security fencing - 8.50 Cum, External Electrification work - 4.25 Cum
M&L for Mild steel posts and struts of angle iron of size 65X65X8mm as in fencing incl cutting tops to shape as directed, drilling holes, notching for wire, etc flat iron fillets(for securing wire mesh etc) incl all necessary drilling, bolting, riveting etc and similar work confirming to Fe-290 Gde E-165, complete all as specified and as directed.
M&L for Mild steel Flat iron of size 40X6mm as in support for fencing inclding cutting to shape as directed, incl all necessary drilling, bolting, riveting etc and similar work confirming to Fe-290 Gde E-165, complete all as specified and as directed.
M&L for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long and 16 to 20mm dia of neck complete all as specified and as directed.
M&L for Mild steel Fe-290 (Gde E-165) 10mm dia and over Round bars, cut to length bent to shape required incl cranking bending spirally for hoping for cols, hooking and binding with and incl mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
Supply only chain Link Fencing of MS galvanisied wire of 4.0mm dia and of mesh size 50X50mm having weight not less than 3.0 kg per squre meter including line wires fixed with nut bolts, flat iron and mild steel round bar to angle iron posts complete all as specified and as directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and as directed.
Preparation of new iron or steel surfaces and applying two coats of synthetic enamel paint over one coat of red oxide primer, of any description not exceeding 10 cm in width or girth when unconnected with other painting or when painted in a different tint including rubbing out complete all as specified and directed by Engineer-in-charge.
Providing, cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregates) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, bed blocks for hold fasts, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, all as specified and directed by Engineer-in-Charge. Qty: Security fencing - 2.10 Cum, External Electrification work - 3.65 Cum
M&L for 10 mm thick rendering in cement mortar 1:6 on fair faces of brick/concrete surfaces of walls including finishing the surfaces even and smooth (without using extra cement), complete all as specified and as directed.
Mterial and labour for preparation of newly plastered surfaces of wall and applying two coats of cement base paint including curing before and after applying each coat complete all as specified and as directed.
SCHEDULE 'A' PART-III FOR INTERNAL ELECTRIFICATION WORK
M&L for Point wiring for one 05 amps socket outlets point controlled by one switch on Independent board with 1.5 sqmm PVC insulated and unsheathed fire retardant low smoke and halogen (FR-LSH) copper conductor single core multi stranded copper cable conforming to IS:694 (2010) using approved colour code for phase and neutral as per IS code drawn through and including non metallic PVC rigid conduit heavy mechanical stress (HMS) grade in accordance with IS:9537 (Part 3) having wall thickness not less than 2.0 mm thick and minimum 20 mm external dia but shall be increased as per actual site requirement in accordance with clause No 19.125 of SSR Part I (ISI marked) including conduit accessories like bends, tees, junction boxes etc with all accessories suitable for modular/conventional type fitment, providing sunk cast pressed steel terminal boxes off size made out of 1.5mm thick MS sheet duly painted with black bitumen paint over two coats of red oxide primer and providing 3 mm thick plastic laminated bakelite sheet (HYLUM BRAND) top cover including PVC insulated and unsheathed FRLSH 1.5 sqmm multi stranded copper conductor cable (green color) as continuous earth lead wire connected to common earth and earth dolly complete all as specified and directed by Engineer-in-charge.
S&F switch piano flush type (ISI marked), single pole, one way 5 Amp, 240 Volts complete all as specified & directed.
S&F socket outlet 2/3 pin, 6 Amp piano flush type complete all as specified & directed.
All as per ser item No 60.00 here-in-before but for 15 amps socket outlets point controlled by one switch on Independent socket outlet using 2.5sqmm PVC insulated and unsheathed fire retardant low smoke and halogen (FR-LSH) copper conductor single core multi stranded copper cable conforming to IS:694 (2010) using approved colour code for phase and neutral as per IS code drawn through an including non metallic PVC rigid conduit heavy mechanical stress (HMS) grade in accordance with IS:9537 (Part 3) having wall thickness not less than 2.0 mm thick and minimum 20 mm external dia but shall be increased as per actual site requirement in accordance with clause No 19.125 of SSR Part I (ISI marked) including conduit accessories like bends, tees, junction boxes etc with all accessories suitable for modular/conventional type fitment, providing sunk cast pressed steel terminal boxes off size made out of 1.5mm thick MS sheet duly painted with black bitumen paint over a coat of red oxide primer and providing 3 mm thick plastic laminated bakelite sheet (HYLUM BRAND) top cover including PVC insulated and unsheathed FRLSH 2.5 sqmm multi stranded copper conductor cable (green color) as continuous earth lead wire connected to common earth and earth dolly complete all as specified and directed by Engineer-in-charge.
S&F switch piano flush type (ISI marked), single pole, one way 16 Amps, 240 Volts complete all as specified & directed.
S&F socket outlet, 2 in 1, 3 pin 6 and 16 Amp, piano flush type complete all as specified & directed.
S&F for Sheet metal enclosure MCB distribution board single pole & neutral 240 volts 8 way with IP-43 IK-09 protection double door complete with appropriate size 200 amps bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification
S&F for 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissionincomplete all as specified and directed.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and neutral and current carrying capacity 32 AMP, in the MCB DB Complete with connection testing and commissionincomplete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electode 600 mm x 600 mm x 6.00 mm thick burried directly in ground (earth pit not less than 2.25 meter deep below normal ground level connected to and including galvanised steel earth lead wire 4 mm dia by means of bolts, nuts, chock, nuts and washers of galvanised iron or steel including PCC Pit in 1:2:4 type B-1 angle iron frame with RCC cover and handle, excavation and earth work in any type of soil medium grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 15mm bore upto main board complete all as shown in electrical plate No 3 of MES Sch 2009 (Part I) connected to main control board as specified and testing completion complete all as specified and directed. Note: (i) The unit rate includes GI pipe up to 7.5m for protection of earth lead. For any additional length the same shall be adjusted through deviation order. (ii) The unit rate includes main earthing lead/strip from earth electrode to test point up to 7.5 meter (iii) In case measured value of earth resistance is recorded less than 1.0 ohms then the earthing shall be re done by the contractor without any extra cost to the department.
M&L for Sub main wiring using PVC insulated and unsheathed fire retardant low smoke and halogen (FR-LSH) copper conductor single core multi stranded copper cable conforming to IS:694 (2010) using approved colour code for phase and neutral as per IS code drawn through non metallic PVC rigid conduit heavy mechanical stress (HMS) grade in accordance with IS:9537 (Part 3) having wall thickness not less than 2.0 mm thick and external dia as under but shall be increased as per actual site requirement in accordance with clause No 19.125 of SSR Part I (ISI marked) including conduit accessories like bends, tees, junction boxes etc with all accessories complete all as specified and as directed by Engineer-in-charge of the following sizes of cables as under: -
Using two single core PVC insulated FRLSH cable 16 sqmm copper conductor multi stranded ( Phase and neutral) and 16 sqmm copper conductor PVC insulated FRLSH cable as earth wire drawing in and including concealed PVC conduit not less than 2.00 mm thick ,32 mm outer dia (ISI marked) with all accessories Note :2 runs of 16 sqmm copper cable & 1 run of 16 sqmm copper cable in and including 32mm PVC conduit shall be measured as one unit
Using two single core PVC insulated FRLSH cable 10 sqmm copper conductor multi stranded (Phase and neutral) and 10 sqmm copper conductor PVC insulated FRLSH cable as earth wire drawing in and including concealed PVC conduit not less than 2.00 mm thick, 25 mm outer dia (ISI marked) with all accessories Note: 2 runs of 10 sqmm copper cable & 1 run of 10 sqmm copper cable in and including 25mm PVC conduit shall be measured as one unit complete all as specified and as directed.
Using two single core PVC insulated FRLSH cable 6 sqmm copper conductor multi stranded ( Phase and neutral) and 6 sqmm copper conductor PVC insulated FRLSH cable as earth wire drawing in and including concealed PVC conduit not less than 2.00 mm thick, 25 mm outer dia (ISI marked) with all accessories Note: 2 runs of 6 sqmm copper cable & 1 run of 6 sqmm copper cable in and including 25mm PVC conduit shall be measured as one unit
S&F for sheet metal enclosures with socket plug top and MCBs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 240 volts 20 Amps complete all as specified and as directed.
SCHEDULE 'A' PART-IV FOR AIR CONDITIONING WORK
Supply, installation, testing and commissioning of hot and cold Super convertible 5-in-1 cooling split Air Conditioner of capacity 2.0 TR (smart cooling with energy saving), complete with HD Filter with Anti Virus Protection, Anti Allergy Filter, duly fitted DUAL Inverter Compressor with Varied Speed Dual Rotary Motor, ADC Sensor, Ocean Black Protection applied on Copper tubes of both Indoor & Outdoor unit, Refrigerant 410A/R32, 4-way air swing operation, over load protection, ISO – 9001 OEM Certification, suitable for operation on 220-240 volts single phase 50Hz Ac supply, comprising of following accessories with technical specification as under: -
(a) Cooling Capacity Range (W) : 1100 to 7000 (b) Heating Capacity Range (W): 1200 to 7100 (c) Power Input Heating/ Cooling: 2100W / 2060W (d) ISEER Value: 3.7 (Minimum) (e) Star Rating: 3 Star (Minimum) (f) Noise Level (Indoor): Not more than 32db (g) Air circulation (In/Out): 670 CFM /1730 CFM (h) Heating & Cooling Function Operation :-10°C to 54°C (j) Air Throw: 16.00 m (minimum) (k) Type of condenser / evaporator: 100% Copper coil. (Aluminium coil / alloy shall not be accepted)
(l) Refrigerant copper piping Minimum 0.8 mm wall thickness for suction and discharge connections the indoor and outdoor units of suitable sizes complete with Nitrile Rubber insulation sleeves with preclad Aluminium & joints rapped with Aluminium tapes after making of flares and joining with suitable size of flare nuts and saddling to the walls symmetrically as per common engineering practice. (m) Providing of electric connection between outdoor and indoor units with suitable size of electric cables along with the units provided by the manufacturer. (n) Machine Control: With Battery Operated Remote Controller having LED / LCD display complete with suitable size and capacity of batteries (cells). (o) Features: AC shall be provide atleast with certain features such as Sleep mode, turbo, swing, LCD / LED remote, lock, timer and temperature display. (p) Drilling of suitable size of hole into wall alongwith 50mm PVC conduit (length equal to depth of hole) for passing of copper tubing (suction and discharge). Provision and connecting wires flexible drain pipe of suitable dia of length as directed by Engineer-in-charge. Note:(i) Connecting copper pipe (Minimum 6m length), Mounting bracket for indoor unit and Good quality PVC drain pipe of 25 mm dia as required included in the cost of item.
S&F for outdoor unit mounting brackets Factory made heavy duty floor anchored made out of MS sheet bent to shape duly slotted for adjustment, powder coated GI/ aluminium stand for fixing Outdoor Condensing Units on the roof (or on the wall as required) of the room with serrated complete with s/sdash/hole fastener's of adequate length for fixing the bracket to wall for mounting of Out Door unit complete all as specified and directed (Set of Two)
Material and labour for fabricating and fixing of snow / rain protection cover shed for outdoor unit made out of MS equal angle 25x25x5 mm with frame work of size 50cmx120cm equal 5 cm height in front of 15 cm height inback side with one supporting member in centre of the frame with heavy duty acrylic sheet of suitable size and thickness complete with Gl hooks/nuts and grouted into the wall and making good the disturbed surface including painting the MS work with two coats synthetic enamel paint over a coat of red oxide primer all as specified and directed. Note: The drawing of shed shall be approved by Engineer-in-charge before erection at site.
SCHEDULE 'A' PART-V FOR EXTERNAL ELECTRIFICATION WORK
Supplying, installing, testing and commissioning of AC 3 phase, 50 HZ, 63 KVA capacity transformer step down, outdoor type, sealed type, 11000/433 volts (at no load) with nominal voltage 11KV all as per IS 1180 (Part 1): 2014, 50 c/s +/-5%, copper wound, mineral oil immersed with first filling of oil as per IS:335, naturally cooled with external cooling tubes, ONAN Cooling, core type, delta connected on primary (HV) side and star connected on secondary (LV) side in accordance with vector symbol DYN-11 (vector group-4) with neutral brought on secondary (LV) side including provision of all necessary / standard fittings all as per IS:2026 & IEC 76 Latest ammendments and conforming to BEE 5 Star Rating (Level 3 transfomer). The maximum allowable losses at 75°C for 11/0.433 KV at 50% of rated load and total losses at 100% of rated load shall not exceed the maximum total loss 219 watts and 791 watts respectively without any positive tolerance.The percentage impedance of transformers at 75°C shall be 4.5%. Overload capacity of transformers shall be suitable for loading as per IS 6600. Audible sound levels shall be 51 decibels (NEMA Standards). The transformer should be designed as per tropical condition of Srinagar, for more details refer particular specification. The transformer shall comprising of the following:-
(a) One cable box on primary H.V side having cable glands suitable for 95 Sqmm 3 core XLPE 11 KV HT cable consisting of 3 Nos porcelain HT bushings with brass bushing rods confirming to IS 2099 and IS 3347 for outdoor bushing complete with nuts and washers.The cross section of the connecting rods shall be stated and shall be adequate for carrying the rated currents. On the HV side the terminal rod shall have a diameter TS for 3 Phase DT 11 of not less than 12 mm. The material of connecting rod shall be copper. HT Cable support clamp should be provided to avoid tension due to cable weight.The HV bushing shall be of 17.5 KV/250 A class, porcelain/ polycrate with non adjustable, single gap type arcing horns.
(b) One cable box on secondary (LV) side consisting of 4 Nos porcelain bushings complying to IS 7421 with GM bushing rods complete with GM nuts and washers with cable gland suitable for reception of outgoing LT sheathed armoured cables having non-magnetic material gland plate with appropriate sized single compression brass glands of suitable size on LV side to terminate XLPE armoured cable. The LV bushing shall be 1.1 KV class: (4 Nos.) .
(c) Corrugated tank: Nominal thickness of corrugation panel sheet is 1.2 mm and tank thickness shall be as per Rectangular Plain Tank. The tank shall be design for a pressure of 25 kPa above atmosphere pressure, measured inside the tank for 30 minutes and vacuum of 250 mm of mercury for 30 minutes. (d) Pressure relief valve shall be of 35 kPa with dia 12.5 mm. (e) Air release plug. (f) Corrugated panels to achieve the desired cooling to limit the specified temperature rise. (g) First fill of fresh transformer oil conforming to IS-335, BS148, D-1473, D-1533-1934IEC Pub296 and tested upto 40 KV dielectric strength. Use of recycled oil is not acceptable. The specific resistance of the oil shall not be less than 2.5X10¹² ohm-cm at 27°C when tested as per IS 6103. (h) One No 100 mm dia dial type thermometer vapour pressure type having range 0-120 degree centigrade with temp reading pointer, max temp indicator and resetting device
(j) Lifting lugs: 2 Nos. of MS plate 8 mm thick (min) suitably reinforced by vertical supporting flat welded edgewise below the lug on the side wall. (k) Pulling lugs: 4 Nos. of welded heavy duty pulling lugs of MS plate 8 mm thick (min) shall be provided to pull the transformer horizontally. (l) Top cover fixing bolts of Stainless Steel of size ½” dia. adequately spaced not more than 80 mm pitch and 6 mm Neoprene bonded cork gaskets conforming to type III as per IS 11149/ type-c as per IS 4253 (Part-2) shall be placed between tank and cover. The Stainless Steel bolts outside tank shall have 2 flat washers & one spring washer. (m) Transformer to be painted with poly urethene/powder coated (color light gray & DA gray) paints over anti corrosive primer. The paint shall be applied by airless spray. Inner side of tank shall be painted with oil resistance paint of colour shade yellow/green. (n) Rating plate with terminal markings: The information of Rating and terminal markings as per IS 1180 (Part-I) 2014, Clause No. 13 shall be engraved (punched) on combined name plate. The Transformer shall be marked with the Standard Mark. Details of Guarantee Period shall also be mentioned in combined Name Plate.
(o) Two numbers of channels having following minimum size 75 x 40 x 460 mm to be provided. The transformers shall be suitable for loading as per IS: 6600 / 1972 with latest amendment if any. (p) Earthing terminals with earthing symbol having minimum size 1⅟2” X ⅟2” with lugs - 2 Nos to facilitate fixing of 32 x 6 m GI earth strip. (q) 4 No. bi-directional detachable rollers of plan solid cast steel. (r) Terminal connectors on the HV bushings and LV bushings.The bi-metallic connectors shall have to be fitted on HV/LV terminals having capacity to withstand 1.5 times of rated HV/LV current of transformer. (s) Arcing horns for HV bushings. (t) Anti-theft stainless steel fasteners with breakaway nut at Top Cover – 4 Nos. (u) LV Cable holding clamp with accessories. (v) Extra bushing for neutral outside the LT cable box for providing independent earthing for neutral. (w) Provision of 2 Nos danger boards 100 x 150 mm size made out of 1.6 mm thick MS plate, vitreous enameled white, with letters, figures of voltage and conventional skull and bones in signal red colour, one at HT side and other on LT side.
(x) Any other fittings/accessories so as to conform the whole transformer to IS 1180 (Part 1): 2014. (y) Prismatic Oil level gauge indicating the position of oil marked with background of yellow color as follows. Min. (-5°C), 30°C, Max.90°C. (z) Non return valve (NRV) -1 No (mandatory for sealed transformer with inert gas). (aa) Drain-cum-sampling metallic valve with plug and explosion vent. Note (i) Any other relevant accessories as required at site as per IS to be provided. (ii) Contractor should submit general arrangement drawing, drawing of combined name plate and technical details sheet to GE before purchase.
Supplying, installing, testing and commissioning of AC 3 phase, 50 HZ, 160 KVA capacity transformer step down, outdoor type, sealed type, 11000/433 volts (at no load) with nominal voltage 11KV all as per IS 1180 (Part 1): 2014, 50 c/s +/-5%, copper wound, mineral oil immersed with first filling of oil as per IS:335, naturally cooled with external cooling tubes, ONAN Cooling, core type, delta connected on primary (HV) side and star connected on secondary (LV) side in accordance with vector symbol DYN-11 (vector group-4) with neutral brought on secondary (LV) side, tapings shall be provided on the higher voltage winding for variation of HV voltage within range of (-) 7.5% to (+)10% in steps of 2.5% by off load tap changer swicth (self position rotary switch) externally operated and when the transformer is in de-energized condition, including provision of all necessary/standard fittings all as per IS:2026 & IEC 76 Latest ammendments and conforming to BEE 5 Star Rating (Level 3 transfomer). The maximum allowable losses at 75°C for 11/0.433 KV at 50% of rated load and total losses at 100% of rated load shall not exceed the maximum total loss 761 watts and 2113 watts respectively without any positive tolerance. The percentage impedance of transformers at 75°C shall be 4.5% Overload capacity of transformers shall be suitable for loading as per IS 6600. Audible sound levels shall be 55 decibels (NEMA Standards). The transformer should be designed as per tropical condition of Srinagar, for more details refer particular specification. The transformer shall comprising of the following:
(a) One cable box on primary HV side having cable glands suitable for 95 Sqmm 3 core XLPE 11 KV HT cable consisting of 3 Nos porcelain HT bushings with brass bushing rods conforming to IS 2099 and IS 3347 for outdoor bushing complete with nuts and washers. The cross section of the connecting rods shall be stated and shall be adequate for carrying the rated currents. On the HV side the terminal rod shall have a diameter TS for 3 Phase DT 11 of not less than 12 mm. The material of connecting rod shall be copper. HT Cable support clamp should be provided to avoid tension due to cable weight. The HV bushing shall be of 17.5 KV/250A class, porcelain/polycrate with non adjustable, single gap type arcing horns.
(b) One cable box on secondary (LV) side consisting of 4 Nos porcelain bushings complying to IS 7421 with brass bushing rods 20mm dia complete with brass nuts and washers with cable gland suitable for reception of outgoing LT sheathed armoured cables having non-magnetic material gland plate with appropriate sized single compression brass glands of suitable size on LV side to terminate XLPE armoured cable. The LV bushing shall be 1.1 KV class: (4 Nos.)
(c) Corrugated tank: Nominal thickness of corrugation panel sheet is 1.2 mm and tank thickness shall be as per Rectangular Plain Tank. The tank shall be design for a pressure of 25 kPa above atmosphere pressure, measured inside the tank for 30 minutes and vacuum of 500 mm of mercury for 30 minutes. (d) Pressure relief valve shall be of 35 kPa with dia.12.5 mm. (e) Air release plug. (f) Corrugated panels to achieve the desired cooling to limit the specified temperature rise. (g) First fill of fresh transformer oil conforming to IS-335, BS148, D-1473, D-1533-1934IEC Pub296 and tested upto 40 KV dielectric strength. Use of recycled oil is not acceptable. The specific resistance of the oil shall not be less than 2.5X10¹² ohm-cm at 27°C when tested as per IS 6103. (h) One No 100 mm dia dial type thermometer vapour pressure type having range 0-120 degree centigrade with temp reading pointer, max temp indicator and resetting device.
(j) Lifting lugs: 4 Nos. of MS plate 8 mm thick (min) suitably reinforced by vertical supporting flat welded edgewise below the lug on the side wall. (k) Pulling lugs: 4 Nos. of welded heavy duty pulling lugs of MS plate 8 mm thick (min) shall be provided to pull the transformer horizontally. (l) Top cover fixing bolts of Stainless Steel of size ½” dia. adequately spaced not more than 80 mm pitch and 6 mm Neoprene bonded cork gaskets conforming to type III as per IS 11149/ type-c as per IS 4253 (Part-2) shall be placed between tank and cover. The Stainless Steel bolts outside tank shall have 2 flat washers & one spring washer. (m) Transformer to be painted with poly urethene/powder coated (color light gray & DA gray) paints over anti corrosive primer. The paint shall be applied by airless spray. Inside of tank shall be painted with oil resistance paint of colour shade yellow/green. (n) Rating plate with terninal markings: The information of Rating and terminal markings as per IS 1180 (Part-I) 2014, Clause No. 13 shall be engraved (punched) on combined name plate. The transformer shall be marked with the Standard Mark. Details of Guarantee Period shall also be mentioned in combined Name Plate.
(o) Two numbers of channels having following minimum size 100 x 50 x 460 mm to be provided.The transformers shall be suitable for loading as per IS: 6600 / 1972 with latest amendment if any. (p) Earthing terminals with earthing symbol having minimum size 1⅟2” X ⅟2” with lugs - 2 Nos to facilitate fixing of 32 x 6 m GI earth strip. (q) 4 No. bi-directional detachable rollers of plan solid cast steel. (r) Terminal connectors on the HV bushings and LV bushings.The bi-metallic connectors shall have to be fitted on HV/LV terminals having capacity to withstand 1.5 times of rated HV/LV current of transformer. (s) Arcing horns for HV bushings. (t) Anti-theft stainless steel fasteners with breakaway nut at Top Cover – 4 Nos. (u) LV Cable holding clamp with accessories. (v) Extra bushing for neutral outside the LT cable box for providing independent earthing for neutral. (w) Provision of 2 Nos danger boards 250 x 200 mm size made out of 1.6 mm thick MS plate, vitreous enameled white, with letters, figures of voltage and conventional skull and bones in signal red colour, one at HT side and other on LT side.
(x) Drain-cum-sampling metallic valve with plug and explosion vent. (y) Prismatic Oil level gauge indicating the position of oil marked with background of yellow color) as follows - Min (-5°C), 30°C, Max 90°C (z) Non return valve (NRV) -1 No (mandatory for sealed transformer with inert gas). (aa) Oil filter valve (1.25 Inch, nominal size thread) -1 No at top of tank. (ab) Any other fittings/accessories so as to conform the whole transformer to IS 1180 (Part 1): 2014. Note: - (i) Any other relevant accessories as required at site as per IS to be provided. (ii) Contractor should submit general arrangement drawing, drawing of combined name plate and technical details sheet to GE before purchase.
S&F Voltage stabilizer servo controlled suitable for automatic operation, three phase, indoor floor mounted, naturally oil cooled & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 V with accuracy ± 1% and speed of correction not less than 6 volts per second for single phase and 13 volts per second for phase to phase of capacity 75 KVA conforming to IS. 9815 (Part-I) /1994 (Reaffirmed 2019) with latest amendments, Painted using 7 tank process system powder coated (color light gray & DA gray) paints over anti corrosive primer, with first filling of Transformer grade Oil conforming to IS: 335/IEC 296 and with necessary by pass arrangement by means of suitable capacity change over switch, fully automatic operation mode. All the three phases will be corrected independently, Suitable for Balanced or 100% Unbalanced Supply, Suitable for Balanced or 100% Unbalanced Load. The stabilizer should be designed as per tropical condition of Srinagar for any detail service condition refer particular specification. The stabilizer should include MCCB of capacity not less than 125 Amps 4 pole for the outgoing stabilized voltage with complete O/L (overload) and S/C (short circuit) protection mechanism. It should includes phase reversal and input single phasing and phase sequence changing protection. LED Indications for each phase input, each phase output, short circuit and over load complete all as specified with following parameters and accessories as under: -
(p) Heavy duty AC synchronous motor for individual phase correction. (q) Solid-state electronic plug in PCB circuits for control. (r) Copper wound in CRGO laminations buck/boost transformer for each phase. (s) Control circuits for individual phase control. (t) Four nos. bi-directional detachable rollers of plan solid cast steel. (u) Protection: Single Phasing Prevention, Output Electronic Overload Protection, Phase reversal protection, Output Low and high Voltage Protection and Surge suppressor Protections. (v) Rating Plate (w) Standard BIS Mark. In addition to above the stabilizer should be provided with Two Nos. Earthing terminals, Cable end boxes for incoming and outgoing side for terminating cables, Oil level indicator, filling & drain valve, lifting lugs, provision for Auto/Manual control from the front panel complete all as specified and as directed by Engineer-in-Charge. Note (i) Any other relevant accessories as required at site as per IS to be provided.(ii) Contractor should submit general arrangement drawing, drawing of combined name plate and technical details sheet to GE before purchase.
M&L for sand cushioning to underground cable with dry sand locally available 8cm thick before laying of the cable and 15cm thick after laying and strectching the cable below the bricks/PCC cover, punning of sand using suitable T&P as per site condition, complete all as specified and as directed by Engineer-in-Charge. Note: Punned thickness of sand to be consider for measurement purpose.
Supply and laying un-reinforced pre cast concrete cable cover conforming to IS:5820 with minimum average breaking load capacity 300 kgs for unreinforced covers , class HV Type 1, flat, size 300mm x 180mm x 40mm complete all as specified and directed by Engineer-in-charge.
Supply and laying un-reinforced pre cast concrete cable cover conforming to IS:5820 with minimum average breaking load capacity 200 kgs for unreinforced covers , class LV Type 1, flat, size 250mm x 150mm x 40mm complete all as specified and directed by Engineer-in-charge.
Supply, installation and erection in true vertical position or to be planted as strut steel tubular swaged welded poles complete with MS base plate of 6mm thick of size 300mmx300mm at bottom duly welded and MS pole cap at top, poles shall made out of ERW MS tubing confirming to IS-1161 part-II, type 410 SP -55 (11.0m long) including drilling of holes of required size and nos for fixing of cross arms/clamps, poles shall be painted internally throughout using anti corrosive black bituminous paint conforming to IS: 158-1968 and externally painted with two coat of red oxide primer and two coats of aluminum paint for expose surface and two coats of black bituminous paint for portion embedded in concrete, painting three black/white bands at lower portion of pole each of 300mm height at 300mm spacing, writing pole no. with black paint in yellow paint circle 10cm dia at suitable height complete all as specified and directed by Engineer-in-charge.
S&F GI pipe light grade 100mm dia as protection to cable along the pole / across road crossing/through culvert/passing through ceiling/walls with necessary clamps-02 nos (made out of Flat iron 50 x 6mm) with nuts and bolts for fixing on pole complete all as specified and as directed.
S&F GI pipe light grade 80mm dia as protection to cable along the pole / across road crossing/through culvert/passing through ceiling/walls with necessary clamps-02 nos (made out of Flat iron 50 x 6mm) with nuts and bolts for fixing on pole complete all as specified and as directed.
S&F GI pipe light grade 50mm dia as protection to cable along the pole / across road crossing/through culvert/passing through ceiling/walls with necessary clamps-02 nos (made out of Flat iron 50 x 6mm) with nuts and bolts for fixing on pole complete all as specified and as directed.
S&F GI pipe light grade 40mm dia as protection to cable along the pole / across road crossing/through culvert/passing through ceiling/walls with necessary clamps-02 nos (made out of Flat iron 50 x 6mm) with nuts and bolts for fixing on pole complete all as specified and as directed.
Supply and Fixing switch air break gang operated triple pole structure mechanically operated from ground level mounted on and including 15 No insulators and steel frame, outdoor type, suitable for vertical installation, single break, fixed contact made of electrolytic copper strip duly electro silver plated with 8 micron thickness and moving conatct made of hard-drawn electrolytic copper rod, flexible jumper flexible breaded tape woven with line tinned copper wire,fixed and moving acrcing horn,treminal connector, Operating Mechanism With Padlocking Arrangement at 'OFF' & 'ON' position, HT post type insulator, copper alloy high pressure assembly with Expulsion drop out fuse assembly 11000 volts grade for each phase 100 amps capacity and operating rod of 25mm dia medium grade GI pipe 6.0 mtrs. in length complete confirming to IS-1018 of 1972 with continuous current rating up to 200 amps and voltage 11KV including testing and conmmissioning all as specified
Supply, fixing, commissioning and testing lightening arrestor expulsion type with all fittings, 65 kilo ampere discharge capacity suitable for 11 KV line, discharge class-II, 9KA, 50Hz transmission class conforming to IS-3070 Part-I -1985 for HT rated voltage 12 KV shall consists of multiple spark gaps in series with one or more non linear resistor limit, voltage surge on alternating current power circuit, suitable for outdoor installation complete all as specified and as directed by Engineer-in-Charge.
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one red oxide primer coat, one under coat and one finishing coat of synthetic enemal paint complete all as specified and as directed by Engineer-in-Charge.
M&L for Anti climbing device spike type fabricated out of MS bars (Round, Square or Flat) including nuts, bolts and washers and welding in two halves made to shape to suit cross section of pole complete all as specified and as directed by Engineer-in-charge.
Supply and fixing for danger notice plate made of 1.6 mm thick mild steel sheet, vitreous enameled white, of size 25 x 20cm with figures, letter, and conventional skull bones in signal red colour and fixed with mild steel clamps made of 25 x 3 mm including MS flat iron, nuts, bolts and washers etc for HT poles / Panels / Sub station etc with voltage and danger indiated in Hindi and English complete all as specified and as directed by Engineer-in-charge.
M&L for Stay assembly set complete using 230 x 230 x 6mm thick stay plate and 20 mm dia rod,180 cm long with all accessories as shown in electrical plate no.1 complete all as specified and as directed by Engineer-in-charge. ( Loop type insulator, stay clamps, excavation and concrete are measured seperately)
M & L for loop type insulator, vitreous porcelain whits brown or green with overall dimension of 90mm x 140mm, clearance of hole 25.50mm complete all as specified and as directed by Engineer-in-charge.
M&L for galvanised stay strand of size 7/4mm complete suitable for stay assembly incl connection on pole complete all as specified and as directed by Engineer-in-charge.
Supply,laying, jointing and testing XLPE insulated screened PVC bedded, galvanised steel strip or wire, electric power cable (heavy duty) suitable for earthed system with Stranded compacted circular Aluminum (H4 Grade) Conductor, shielded with black extruded semiconducting compound XLPE insulated, core shielded with black extruded semi-conducting compound, copper tape, coloured strips having Red, Yellow & Blue for core identification, single layer of round galvanized steel strip armoured and black extruded PVC (Type ST-2), overall sheathed, conforming generally to IS:7098(Part-II)/1985 and its latest amendments of size 6.35/11KV( E) volts grade, cross sectional area 95sqmm, 3 core, laid in trenches/ducts/pipes etc complete all as specified and as directed by Engr-in- charge.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and as directed by Engr-in- charge.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and as directed by Engr-in- charge.
Supply,laying,jointing and testing, fixing to wall using clamps/pole/floor or in air or passing through pipes/ducts/road/path/drain, laid in trenches, 1100 volts grade heavy duty electric cable XLPE insulated, screened, PVC bedded, galvanised steel wire or wire armoured with electric power cable 1100 volts grade with stranded aluminium conductor of size 3.5 core 240 sqmm conforming to IS - 7098 Part-1 and its latest amendments complete all as specified and as directed by Engineer-in-charge.
Supply,laying,jointing and testing, fixing to wall using clamps/pole/floor or in air or passing through pipes/ducts/road/path/drain, laid in trenches, 1100 volts grade heavy duty electric cable XLPE insulated, screened, PVC bedded, galvanised steel wire or wire armoured with electric power cable 1100 volts grade with stranded aluminium conductor of size 3.5 core 150sqmm conforming to IS - 7098 Part-1 and its latest amendments complete all as specified and as directed by Engineer-in-charge.
Supply, laying, jointing and testing, fixing to wall using clamps/pole/floor or in air or passing through pipes/ducts/road/path/drain, laid in trenches, 1100 volts grade heavy duty electric cable XLPE insulated, screened, PVC bedded, galvanised steel wire or wire armoured with electric power cable 1100 volts grade with stranded aluminium conductor of size 3.5 core 50sqmm conforming to IS - 7098 Part-1 and its latest amendments complete all as specified and as directed by Engineer-in-charge.
M & L for Cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 25 to 50 sqmm 3.5core complete all as specified and as directed by Engr-in- charge.
M & L for Cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm 3.5 core complete all as specified and as directed by Engr-in- charge.
Supply and fix CI cable route indicator 150mm dia , 5mm thick duly engraved with " HT 11000 volts" and bolted/welded to MS angle iron of size 40x 40x5 mm,70 cm long, 50cm above ground level and 20 cm below ground, painted with 2 coats of synthetic enamel paint using approved colour over a coat of red oxide primer. The route indicator should be grouted in PCC using (1:2:4) type B-1 of size 150x100mm below the ground level complete all as specified and as directed by Engineer-in-charge
Supply and fix CI cable route indicator 150mm dia , 5mm thick duly engraved with " LT 1100 volts" and bolted/welded to MS angle iron of size 40x 40x5 mm,70 cm long,50cm above ground level and 20 cm below ground, painted with 2 coats of synthetic enamel paint using approved colour over a coat of red oxide primer. The route indicator should be grouted in PCC using (1:2:4) type B-1 of size 150x100mm below the ground level complete all as specified and as directed by Engineer-in-charge
Supply, installation, testing and commissioning of LT Feeder Pillar outdoor type confirming of IS 5039, CPRI approval, totally enclosed vermin proof suitably ventilated for 3 phase, 4 wire 415 Volts, 50Hz, AC supply, outer sheel shall be made out of 3.15mm thick CRCA sheet & MS angle section of suitable size for frame, factory fabricated, compartmentalized inner shell shall be made of out of 2.0 mm thick CRCA sheet for control gear. Front and back door operating with locking arrangement at front. Panel shall be provided with proper ventilation arrangement from both sides including ventilation fan etc. Protection of enclosure IP 65 with pre-treatment through 7 tank hot chemical process prior to powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable plate having provision for entry of armoured cable of adequate size. Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided. The panel shall be provided with manufacturer name plate having CA No also, heavy duty SS cable glands of adequate size for incoming and outgoing cables. EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support required with four legs 60cm long using angle iron 40x40x6mm duly painted with anti corrosive paint, air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, 4 x legs 40 cm grouted in PCC 1:2:4 and making good distrubed surface complete and comprising of the following:
(A) (i) TPN Aluminium electrolytic grade bus bar of capacity 300 Amps for phases & 160 Amps for neutral and auxillary bus bar to support main busbar duly supported on SMC/DMC, busbar supports and insulated with colour coded heat shrinkable sleeve (ii) Digital multifunction meter (V, A, KW, KWH) 415 AC alongwith C.T's of suitable ration (se of three), class 1.0, complete (iii) Indication lamps LED type (RYB) =01 set of three . CTs 250/5A class, 1.0, 15VA (Cast Resin) for metering-03 nos (iv) Internal wiring with suitable size of FRLS copper conductor cable.
B. INCOMER (i) MCCB 200 Amp 4 pole, 25 KA, lcs = 100% lcu, with fixed magnetic and adjustable thermal release, adjustable overload 80-100% and adjustable short ckt 5 to 10 ln setting complete with phase seperator - 01 nos (ii) ON Load change over switch without enclosure 160 amps 4 pole TPN front handle operated -01 nos
C. OUTGOING (i) MCCB 63 Amp 4 pole, 16 KA, lcs =100% lcu, with fixed magnetic and adjustable thermal release, adjustable overload 80-100% and adjustable short ckt 5 to 10 ln setting complete with phase seperator - 03 Nos (ii) MCCB 100 Amp 4 pole, 16 KA, lcs =100% lcu, with fixed magnetic and adjustable thermal release, adjustable overload 80-100% and adjustable short circuit 5 to 10 ln setting complete with phase seperator - 01 nos
D. Platform for feeder pillar/LT Panel shall be of suitable size as directed 200mm height above ground level, the foundation shall be using PCC 1:2:4 type B1,15cm thick, brick (sub class B) work in CM 1:6, redering 1:6 on exposed surfaces and 100mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate as in padding on top and grouting legs of panel.
Note: (i) LT panel shall be CPRI approved (ii) Contractor shall submit the following Test report i.e. IP Test Report and verification of short circuit withstand test report issued by CPRI in respect of LT Panel (iii) Contractor shall submit drawing to GE for approval prior to place order.
Supply, installation, testing and commissioning of LT Feeder Pillar outdoor type conforming of IS 5039, CPRI approval, totally enclosed vermin proof suitably ventilated for 3 phase, 4 wire 415 Volts, 50Hz, AC supply, outer sheel shall be made out of 3.15mm thick CRCA sheet & MS angle section of suitable size for frame, factory fabricated, compartmentalized inner shell shall be made of out of 2.0 mm thick CRCA sheet for control gear. Front and back door operating with locking arrangement at front. Panel shall be provided with proper ventilation arrangement from both sides including ventilation fan etc.Protection of enclosure IP 65 with pre-treatment through 7 tank hot chemical process prior to powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable plate having provision for entry of armoured cable of adequate size. Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided.The panel shall be provided with manufacturer name plate having CA No also, heavy duty SS cable glands of adequate size for incoming and outgoing cables. EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support required with four legs 60cm long using angle iron 40x40x6mm duly painted with anti corrosive paint, air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, 4 x legs 40 cm grouted in PCC 1:2:4 and making good distrubed surface complete and comprising of the following:
(A) (i) TPN Aluminium electrolytic grade bus bar of capacity 160 Amps for phases & 100 Amps for neutral and auxillary bus bar to support main busbar duly supported on SMC/DMC, busbar supports and insulated with colour coded heat shrinkable sleeve (ii) Digital multifunction meter (V,A,KW,KWH), 415 AC alongwith C.T's of suitable ration (se of three), class 1.0, complete (iii) Indication lamps LED type (RYB) =01 set of three. CTs 100/5A class, 1.0, 15VA (Cast Resin) for metering-03 nos (iv) Internal wiring with suitable size of FRLS copper conductor cable.
B. INCOMER (i) MCCB 320 Amp 4 pole, 35 KA, lcs = 100% lcu, with adjustable magnetic and thermal release, adjustable overload 80-100% and adjustable short ckt 5 to 10 ln setting complete with phase seperator - 01 nos (ii) ON load change over switch without enclosure 320 Amps 4 pole, front handle operated - 01 nos
C. OUTGOING (i) MCCB 63 Amp 4 pole, 16 KA, lcs =100% lcu, with fixed magnetic and adjustable thermal release, adjustable overload 80-100% and adjustable short ckt 5 to 10 ln setting complete with phase seperator - 05 Nos
D. Platform for feeder pillar/LT Panel shall be of suitable size as directed 200mm height above ground level, the foundation shall be using PCC 1:2:4 type B1,15cm thick, brick (sub class B) work in CM 1:6, redering 1:6 on exposed surfaces and 100mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate as in padding on top and grouting legs of panel.
Note: (i) LT panel shall be CPRI approved (ii) Contractor shall submit the following Test report i.e. IP Test Report and verification of short circuit withstand test report issued by CPRI in respect of LT Panel (iii) Contractor shall submit drawing to GE for approval prior to place order.
Supply, installation, testing and commissioning of LT feeder pillar box (KIOSK) outdoor type with provision of aluminium busbar three phase and neutral(TPN) with 4 strip 80 cm long duly colour coded 100 amps capacity for phases and 50 amps capacity for neutral , mounted on epoxy resin base insulators, ,drilled holes for cable connection on bus bar confirming of IS 5390, CPRI approved, totally enclosed vermin proof suitably ventilated for 3 phase, 4 wire 415 Volts, 50Hz, AC supply, outer sheel shall be made out of 3.15mm thick CRCA sheet & MS angle section of suitable size for frame, factory fabricated. Front and back door opening. Protection of enclosure IP 65 with pre-treatment through 7 tank hot chemical process prior to powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable plate having provision for entry of armoured cable of adequate size. Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided. EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support required with four legs 60 cm long using angle iron 40x40x6mm painted with corrosion resistant paint, and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, legs grouted in PCC 1:2:4 including provision of MCCB 40 Amp 4 pole, 16 KA, lcs =100% lcu, with fixed magnetic and adjustable thermal release, adjustable overload 80-100% and adjustable short circuit 5 to 10 ln setting complete with phase seperator - 01 nos and Platform for feeder pillar/LT Panel shall be of suitable size as directed 200mm height above ground level, the foundation shall be using PCC 1:2:4 type B1,15cm thick, brick (sub class B) work in CM 1:6, redering 1:6 on exposed surfaces and 100mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate as in padding on top and grouting legs of panel complete all as specified and as directed.
Note: (i) LT feeder pillar shall be CPRI approved (ii) Contractor shall submit the following Test report i.e. IP Test Report and verification of short circuit withstand test report issued by CPRI in respect of LT Panel (iii) Contractor shall submit drawing to GE for approval prior to place order.
M & L for Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron strip of size 32 x 6 mm as earth lead up to test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1 using 20mm graded stone aggregates, 40mm thick precast RCC cover in 1:2:4 reinforced with expanded metal (weight not less than 4 kg/sqm), and frame of angle iron 25x25x6mm with lugs 02 nos with 6mm dia MS bar handle made to shape, excavation and earth work in any type of soil and including medium grade GI watering pipe 20mm bore with funnel and wire mesh and medium grade GI earth wire/strip protection pipe 40mm bore up to main board complete as shown in electrical plate no 3 of MES schedule Part-I, connected to earthing testing point and testing on completion complete all as specified and directed by Engineer-in-charge. Note: (i) The unit rate includes GI pipe up to 7.5m for protection of earth lead. For any additional length the same shall be adjusted through deviation order. (ii) The unit rate includes main earthing lead/strip from earth electrode to test point up to 7.5 meter (iii) In case measured value of earth resistance is recorded more than 1.0 ohms then the earthing shall be re done by the contractor without any extra cost to the department.
M&L for earth continuity conductor or main earthing lead/strip fixed to wall or burried in ground or drawn in conduit (pipe/fixed to poles) of any type or any other situation for loop earthing etc with GI Strip of size 32 x 6mm complete all as specified and as directed by Engineer-in-charge.
M&L for cutting of existing road surfaces up 100 mm deep & 300 mm wide and making good disturbed portion with 100mm thick plain cement concrete 1:2:4 type B-1 (using 40mm graded crushed stone aggregate) complete all as specified and directed by Engineer-in-Charge.
S & F Expanded metal, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members Weight per square metre not execeeding 4.0kg complete all as specified and as directed
M & L for aggregate for loose filling, of gauge 40 mm to 80 mm graded around the transformer inside the fencing of suitable thickness as directed complete all as specified
M & L for Transformer platform made of brick masonry size 2400mm x 1800mm x 1200mm, PCC foundation, 1:3:6 type C-2, PCC platform 1:3:6 type C-2 with brick work sub class'B' bricks in cement motar 1:4 and plaster work 12mm thick in cement plaster 1:4 incl sand filling and elevated with Angle iron guard rail of 600mm height welded with M.S Angle iron 60x60x6mm, MS flat 50x6mm for interlocking arrangements and supply and fixing of guard rails wire netting of galvanized steel wire 1.40mm dia with 25x25mm mesh size fixed with tinned tracks of wire staples duty painted with two coat of synthetic enamel aluminium/smoke grey paint over a coat primer complete all as shown in Drg No CE/TD-1129/96 sheet 1/2 complete all as specified and as directed by Engineer-in-charge.
M&L for Boring of holes under road, pavement, hardstanding by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
S& F for Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified and as directed by Engineer-in-Charge.
S& F Disc type insulator, porcelain, vitreous, white, brown, green including one galvanised mild steel straps washers insulator bolts, washers, nuts, size of insulator 145mm high and 255mm dia for 11000 volts grade complete all as specified and as directed by Engineer-in-Charge.
Supply, fixing and streching in position Aluminium conductor, Steel reinforced (ACSR), of any size for overhead HT line with and including binding wire 14 SWG (aluminium) for jumpers complete all as specified and as directed by Engineer-in-Charge.
SCHEDULE 'A' PART-VI FOR EXCAVATION AND EARTH WORK FOR ALL SCHEDULES OF THIS BOQ
Excavating in trenches, n exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth in Hard/Dense soil and getting out soil, complete all as specified and as directed by Engineer-in-Charge. Qty: Bldg work-0.30 Cum, Security fencing - 35.00 Cum, External Electrification work - 5762.50 Cum
Excavating in post holes (or similar holes) each n exc 0.5 cum, in hard/dense soil, incuding getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and as directed.
Returning, filling in of excavated soil, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed. Qty: Security fencing - 23.25 Cum, External electric work - 3581.00 Cum
Removing excavated soil n exc. 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. Qty: Security fencing - 11.75 Cum, External electric work - 2181.50 Cum
Excavating in trenches, n exc 1.5 m wide and exc 1.5 m but not exceeding 3.00 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. n exc 10 sq m on plan in Hard/Dense soil and getting out soil, complete all as specified and as directed by Engineer-in-Charge. Qty: External Electrification work - 1.00 Cum
NOTE: (i) Total amount of relevant part of Schedule of Credit amounting to Rs (as mentioned in Sch of credit) for retrieved material on relevant page of tender documents in PDF format which will be deducted offline during acceptance of Tender. (ii) Similar items of different parts of this BOQ have been clubbed in any one part of this BOQ to avoid duplicacy and also to avoid quoting of different rates for similar item(s) by the bidder(s). During execution the same item(s) will be measured under relevant schedule of this BOQ while measuring in MB
R D Bansal
SATISH AND CO
ALCO ENGINEERSPVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .