| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.5 LAccepted-AOC | ₹43.5 L Quoted ₹44.9 L | L1 | Accepted-AOC ACCEPTED |
| 2 | L2₹47.4 L+₹2.4 L (5.37%)Rejected-Finance | ₹47.4 L+₹2.4 L (5.37%) | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹47.8 L+₹2.9 L (6.42%)Rejected-Finance P O CHAMURCHI BAZAR CHAMURCHI DIST JALPAIGURI | CHAMURCHI | JALPAIGURI | WEST BENGAL | ₹47.8 L+₹2.9 L (6.42%) | L3 | Rejected-Finance NOT LOWEST |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
25 Jan 2021, 6:00 pmClosed
GE SEVOKE ROAD
GE SEVOKE ROAD POST SALUGARA DIST JALPAIGURI
PROVN OF INTERCONNECTION BETWEEN CSA PUMP HOUSE TO PUMP HOUSE NO 04 AND SUBMERSIBLE PUMP SET FOR MAP AREA AND SPL REPAIR REPLACEMENT OF DECRINE DOZING PUMP AND SUBMERSIBLE PUMP SETS AND CERTAIN MINOR WORKS AT SEVOKE MIL STN UNDER GE SEVOKE ROAD
2020_MES_395460_2
GE/SEV/42 OF 2020-21
Open Tender
Civil Works
Item Rate
120 days
GE SEVOKE ROAD
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE SEVOKE ROAD
₹92,000
Yes
9 Feb 2021
8 Jan 2021
27 Jan 2021
8 Jan 2021
25 Jan 2021
12 Jan 2021
9 Jan 2021 - 9 Jan 2021
Amount
PHASE-I
Excavation in trenches not exc 1.5m wide and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm in soft/loose soil complete all as specified and directed.
Removing excavated soil to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point all as specified and as directed.
Supply , installation , testing and commissioning of chlorine feed high pressure dozing pump set with accessories having minimum flow rate of 25 LPH, minimum discharge pressure 15 Kgs/cm2 and liquid chlorine dozing system consisting of atleast 100 ltr FRP tank with accessories and fitted with automatic mixer (non manual) including making connection in main line and fixing arrangement including taking out u/s dozing pump and remove from site complete all as specified and directed. Note: (i) Unsv dozing pump shall be deposited in MES store yard of AGE E/M Sevoke Road. (ii) Dozing pump set shall be maintained by the contractor through OEM during defect liability period ie 24 months from the certified date of completion and quoted rate shall deemed to be included in the unit rate of this item. (iii) Maintainance of Dozing pump set after expiry of defect liability period through OEM shall be measured and paid seperatly under item No. 53 of Phase-II.
S & F in repair 15 mm bore steel water tubing galvanised ,medium grade with all fittings and fixed complete to walls, or in floors, in old/new situation complete all as specified
S&F in repair 15mm bore Stop valves, cast copper alloy,screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S & F in repair fully automatic star delta submerssible pump controller with feature of protection from overload single phasing, phase reversal, phase imbalance, auto restart with indication of On/Off, voltage and amp in sheet metal enclosure MU-G15 type Make: L & T Cat Part CS94091SODO or equivalent from list of make for 15 HPMotor RELAY RANGE 13-22A 415V, 50Hz, 3phase all as specified and directed by Engr-in-Charge
Supply, laying, jointing & testing galvanized iron tubing 100m bore medium grade with all fittings such as bends, elbow,tee, socket, reducers, unions etc as required at site laid in trenches including taking out u/s pipe and remove from site complete all as specified and directed.
S&F in repair flat submersible motor cable, three core, copper conductor of size 6.0 Sqmm, including providing necessary connection and testing on completion complete all as specified and directed.
M&L for P.C.C. 1:4:8 Type D-2, (using 40mm graded stone aggregate) as in foundation of poles,stays,struts or any other indicated work including form work(if required) complete all as directed by Engr-in-Charge
Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Supply, installtion, commissioning and testing multi stage submersible pump set having capacity not less than 400 lpm discharge at a head of 70 meter, with bronze impeller, directly coupled with motor suitable for 100mm bore column pipe, motor rating 15 HP, pump type three phase 415 volts , 50 Hz complete all as specified and directed. Make- KSB/Kirloskar/crompton greaves
Supply, installtion, commissioning and testing multi stage submersible pump set having capacity not less than 300 lpm discharge at a head of 70 metre, with bronze impeller, directly coupled with motor suitable for 100mm bore column pipe, motor rating 10 HP pump type three phase 415 volts , 50 Hz complete all as specified and directed. Make- KSB/Kirloskar/crompton greaves
Supply, installtion, commissioning and testing multi stage submersible pump set having capacity not less than 160 lpm discharge at a head of 50 meter, with bronze impeller, directly coupled with motor suitable for 50mm dia column pipe, motor rating 6 HP, pump type three phase 415 volts , 50 Hz complete all as specified and directed. Make- KSB/Kirloskar/cromptongreaves
Supply only column pipe 100 mm bore galvanized iron heavy grade, 3 meter in length & both ends long threaded, including provision of heavy duty coupling/socket 100mm bore complete all as specified and directed.
Supply only column pipe 50 mm bore galvanized iron heavy grade, 3 meter in length & both ends long threaded, including provision of heavy duty coupling/socket 50mm bore complete all as specified and directed.
M&L for taking up/lifting of defective submersible motor and pump assembly complete of any type/size of 15 HP with unserviceable cable of any capacity from deep tube/borewell (of any depth) after providing lifting tools and tackles complete as required at site, carefully disconnecting of all electric connections, water connections in and including dismantling of column pipe lines shaft ( of any size and length stage by stage) and keeping them aside under safe custody for reuse (after repairing of the pump and motor assembly) at site complete all as specified and directed by Engr-in-charge. Note: New column pipe will be measured and paid separately.
M&L for lowering of new submersible motor and pump assembly complete of any type/size of 10 HP capacity with submersible cable of anymake and size complete in deep tube/borewell of any depth coupling with pump and motor, in and including connecting and lowering of column pipe line shaft of any size and length (stage by stage) carefully with the help of necessary tools and tackles, including providing PVC insulated steel rope (stranded) of 8 mm dia, duly fixed with the motor pump set U bolts and clamps of size fixed on the clamps for mechanical support for the motor pump set anchoring outside the borewell of suitable length reconnecting of all electric and water connections with new nuts bolts washers and rubber gasket and testing on load upto the entire satisfaction of engr-in-Charge complete all as specified and directed. Note: New column pipe will be measured and paid separately.
M&L for taking up/lifting of defective submersible motor and pump assembly complete of any type/size of 6 HP capacity with unserviceable cable of any capacity from deep tube/borewell (of any depth) after providing lifting tools and tackles complete as required at site, carefully disconnecting of all electric connections, water connections in and including dismantling of column pipe lines shaft ( of any size and length stage by stage) and keeping them aside under safe custody for reuse (after repairing of the pump and motor assembly) at site complete all as specified and directed by Engr-in-charge. Note: New column pipe will be measure and paid separately.
M&L for lowering of new submersible motor and pump assembly complete of any type/size of 6 HP capacity with submersible cable of any make and size complete in deep tube/borewell of any depth coupling with pump and motor, in and including connecting and lowering of column pipe line shaft of any size and length (stage by stage) carefully with the help of necessary tools and tackles, including providing PVC insulated steel rope (stranded) of 8 mm dia, duly fixed with the motor pump set U bolts and clamps of size fixed on the clamps for mechanical support for the motor pump set anchoring outside the borewell of suitable length reconnecting of all electric and water connections with new nuts bolts washers and rubber gasket and testing on load upto the entire satisfaction of engr-in-Charge complete all as specified and directed. Note: New column pipe will be measured and paid separately.
Supply and fixing including lowering of steel wire rope, PVC insulated of size 10 mm dia of suitable size/length as directed with clamps, nuts & bolts and washers etc for holding column pipes/ GI pipes of submersible pump set complete all as directed by Engr-in-Charge.
Excavation in trenches for road cutting not exc 1.5 mtr wide and not exc 1.5 mtr in depth and getting out excavated material for laying/ taking out pipe line in any type of soil complete all as specified and directed
Supply, fixing and testing DI fittings for spigot & socketed or flanged pipes i.e. Mechanical seal bends, reducers, tail pieces, tapers, tees, collars, caps, plugs with MS plate, nuts, bolts, washers gaskets etc of sizes 80mm to 200mm dia including taking out Unserviceable complete all as specified and directed
Supply, laying, jointing and testing of 150 mm bore Ductile iron (DI) , pressure pipes Centrifugally Cast (Spun) inside cement mortar lining duly ISI marked with Spigot & Socket end, Class K-9 conforming to IS:8329/2000 including (push-on) rubber gasket jointing laid in trenches complete all as specified and directed Engineer In Charge .
Cutting of existing cast iron/DI pipes upto 150 mm bore in any position for insertion and fitting of new Tee, Collar, Tail pieces etc for taking out connections, branch connections complete all as specified and as directed.
S & F cast iron sluice valve PN 1.6 150mm bore with Stainless steel spindle nuts, bolts, washers and rubber gasket sheet for packing including fixed at any position all as specified and directed by Engr-in-Charge.
M & L for PCC (1:3:6) type C1 using 20mm graded aggregate for repair of road cutting all as specified and directed by Enginner- in -Charge
M&L for construction of valve chamber of size 1200mm x 1200mm x1200mm (internal dimensions) with MS sheet cover 3mm thick with angle iron frame of size 50 x 50 x 6mm and locking arrangements including excvation and earth work in any type of soil,PCC (1:4:8) type D2 in foundation ,PCC benching 1:2;4 type B-1 ,PCC (1:5:8) block masonry 20 cm thick in cement mortor (1:6),10 mm thick plastering in CM 1:4 ,PCC bed in (1:3:6) and coping 50mm thick in cement concrete 1:2:4 type B1 using 20mm stone aggregate including necessary formwork,painting one coat of red oxide and two coats of bituminious black paint on all steel surfaces, complete all as specified and as directed.
S & F submerssible pump set of Capacity, 2HP Delivery size 50mm, max solid size 35mm, single phase with 50mm PVC pipe of length -15 mtr with clamp 02 set complete all as specified and directed.
S&F flat submersible cable 3 core multi stranded copper conductor of size 4 sqmm.ISI marked complete all as specified and as directed.
M&L for water proof, 3core PVC insulated and PVC sheathed, copper conductor cable of size 2.5 sqmm, 1100 Volts grade for electrical connection of street light fittings, complete all as specified and directed.
Supply and fixing thermoplastic polycarbonate cable junction box having protection IP 66 "dust proof, acid resistant, shock proof, fire retardent self extinguisher" for outside installation with knockout entry for cable of size 10 - 16 sqmm and 155x210x92mm with terminals, brackets for street light pole mounting and provision of one 6A MCB SP all as specified and as directed.
Supply only new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium flood light 100 watt with high power discrete high lumen LED as light source with lumious efficiency of min 100 lm/w, with rated 100W with SPD, IP 66 protection with toughened glass cover incl fixing arrangements in security fencing complete all as specified and as directed.
Supply and laying burnt clay sub class B brick as cable protection including taking down old u/s all as specified and directed.
Supply & laying in trenches clear sand for cushioning under cable, 8 cm below and 15 cm above including consolidation all as specified and directed by Engr-in-Charge. Note: Punned thickness shall be measured.
Supply and laying in trenches/wall LT UG XLPE insulated ,armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 10sq mm 4 core including including taking down old u/s making necessery connections all as specified and as directed.
Supply and fix voltage stablizer for automatic operation, single phase naturally air cooled indoor type wall mounted and designed for input variation between 130 volts to 250 volts with out put voltage stablized at 230 volts with accuracy of + 2.5% and capacity 4 KVA suitable for AC complete all as specified.
M&L for submain wiring with and including casing caping with two single core PVC insulated, unsheathed, stranded copper conductor of size 4.0 Sqmm and one single core PVC insulated, unsheathed solid copper conductor 4.0 Sqmm and green in colour as earth lead with all fitting & accessories complete all as specified and directed by Eng-in-Charge.
Supply and Installation, commissioning of wall mounting hot & cold split type unit air conditioner electric driven single phase indoor unit and outdoor unit with cordless remote control unit and with in built airioniser and plasma filter for better indoor air quality cutting ,brazing and connecting the copper pipe of size 1/2 inch and 1/4 inch size of pipe and making holes as for passing of copper pipes and electric cables and pressure testing with nitrogen and freon gas vacumising the system and charging the Non CFC refrigerent and testing the complete system for smooth functioning of split AC up to satisfactioning, confirming to IS-1391 Para II 1992 herimatically sealed air compressor working with Non CFC refrigerent suitable for wall mounting 1.5 Ton 5 Star Rating complete all as specified and directed.
S & F switch socket combination including MS sunken box with hylum sheet 2 in 1 multipurpose 3/5 pin 5/15 amps flush type all as specified.
S&F in repair energy efficient, 5 star rated ceiling fan, 230V, 1200 mm sweep with all accessories and connecting up with the ceiling rose with required flexible wire of suitable size including making provision for hanging fan on any type of ceiling complete all as specified and as directed.
S & F for water heater storage type (Geyser) vertical type of capacity 25 ltrs, 5 Star, electrically operated, AC 230 Volts, including 04 Nos of hold fastner nuts, plug top etc. of suitable size including fixing complete all as specied and directed.
Supply and fixing 15mm bore GI tubing medium grade ISI marked in floor/ on wall with and including all fittings such as bends, tees,sockets,reducers,elbows, unions,clamps etc for inlet & out connection of Geyser complete all as specified.
M & L for PVC connection pipe (copper) chromium plated 8 mm dia both end threaded incl brass coupling bolt cone washer complete , length of pipe is not less than 600 mm suitable for Hot/ cold water complete as all specified and directed.
S & F Bib cock 15 mm dia cast copper alloy with butter fly handle, screwed down, screwed one ends for pipe of 15 mm dia complete all as specified and directed.
S & F Stop valves, cast cooper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed but fancy type chromium plated off size 15 mm dia complete all as specified and directed.
Supply and fixing refrigerator of 215 ltrs capacity electric driven (single phase) 5 star rating suitable for operation on 230 Volts 50 cycles AC supply complete all as specified and directed.
Supply and fix voltage stablizer for automatic operation, single phase naturally air cooled indoor type wall mounted and designed for input variation between 130 volts to 250 volts with out put voltage stablized at 230 volts with accuracy of + 2.5% and capacity 2 KVA suitable for AC complete all as specified.
M & L for sub main wiring with two single runs of single core 4 sqmm PVC insulated unsheathed multisreanded 1100 volts grade with copper conductor drawn through and including non metallic PVC rigid conduit medium grade ISI marked and its accessories including one run of single core 4 Sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth contuinity conductor along with the wiring and connected from DB to DB/ main board complete all as specified.
PHASE-II
Comprehensive maintenance of 06 (Six) Nos dozing pump sets installed under item No 05 of Phase-I here-in-before for three year after expiry of defect liability period all as directed by Engineer-in-Charge. Note:- Spare parts required for maintanance shall be provided by the contractor at his own cost as directed by Engr-in-Charge, during the maintanance period of dozing pump set. The cost of all the spare parts required to make functional of dozing pump stes shall be deemed to be included in the unit rate quoted by the contractor. Quoted rate includes all the six nos of dozing pump sets.
SRI SURAJIT SENGUPTA
JHA CONSTRUCTION AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .