| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.9 LAccepted-AOC NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L1 | Accepted-AOC L1 | |
| 2 | L2₹14.5 L+₹58,320 (4.20%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹15.8 L+₹1.9 L (13.7%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹16.8 L+₹3.0 L (21.3%)Rejected-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L4 | Rejected-AOC L4 | |
| 5 | L5₹18.6 L+₹4.7 L (34.2%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹19.2 L
EMD Value
₹38,440
Closing Date
9 Oct 2021, 6:00 pmClosed
GE (AF) Yelahanka
GE (AF) Yelahanka Bangalore - 63
REPAIR/MAINTENANCE OF SOLAR WATER HEATER AND MISC WORK AT AFS YELAHANKA
2021_MES_474677_1
8922/E8
Open Tender
Civil Works
Item Rate
330 days
AFS Yelahanka
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Yelahanka
₹38,440
Yes
9 Dec 2021
13 Sept 2021
11 Oct 2021
13 Sept 2021
9 Oct 2021
27 Sept 2021
Amount
Excavation in trenches in any type of soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out excavated soil all as direted.
Returning & filling in trenches around pipe line, including spreding, leveling in layers n.exc 25 Cm after laying pipes and well ramming.
M& L for removal of surplus excavated soil to a distance not exceeding 50 mtr away from site and depositing where as directed at a level n.ecx 1.5 mtr above ground level.
Taking down 15mm dia GI steel tubing including fittings and fixtures including cleaning for refixing or removal to store all as specified and directed.
All as per item No.4 but 20mm dia GI Steel tubing
All as per item No.4 but 25mm dia GI Steel tubing
All as per item No.4 but 40 mm dia GI Steel tubing
All as per item No.4 but 50 mm dia GI Steel tubing
Re-fixing old GI steel tube 15mm dia obtained from above including cleaning/scaling and making connections in new or old position fixed on walls/ceiling/floor etc all as specified and directed.Note: The rate quoted shall be inclusive of providing necessary fittings for refixing the pipe complete all as specified and directed by Engr-In-Charge
All as per item No.9 but 20mm dia GI Steel tubing
All as per item No.9 but 25mm dia GI Steel tubing
Supply and fixing GI tubing medium grade 15mm dia with all fittings complete to walls/ceilings or laid in floor complete all as specified and directed by Engr-In-Charge.
All as per item No.12 but 20mm dia GI Steel tubing
All as per item No.12 but 25 mm dia GI Steel tubing
All as per item No.12 but 40 mm dia GI Steel tubing
All as per item No.12 but 50 mm dia GI Steel tubing
Supplying & Laying in replacement of CPVC pipe size 25mm and CPVC SDR 11 fittings in trenches complete with nececssary fittings complete all as specified and directed by Engr-In-Charge
Supplying & Laying in replacement of CPVC pipe size 32mm and CPVC SDR 11 fittings in trenches complete with nececssary fittingscomplete all as specified and directed by Engr-In-Charge
Dismantling of PVC/RCC water tanks and S&F 1000 Litres capacity cold water storage tank Mono layer HDPE water storage tanks (cylindrical vertical with closed tap) hoisted and fixed in position complete all as specified and directed by Engr-In-Charge
M&L in replacement of ball valve for 25mm dia, high pressure of PTMP with exoxy quoted aluminium rod and high density plastic ball screwed for iron pipe and fixed complete all as specified and directed by Engr-In-Charge
All as per item No.20 but size 20mm dia
Supply and fixing in replacement of PVC lid cover for PVC tank of different capacity mentioned above all as directed by Engr-in-Charge
Dismantling the solar water heating system of 100/200 ltrs capacity cleaning the complete system wire brush and washing the panel with detergent and carrying out the servicing and reinstallation and commissoining of the system complete all as specified and directed by Engr-In-Charge. Note : Spare parts replaced will be measured and paid separately relevant items
Taking down the solar collector panel in replacement of Supply & fixing in 100 LPD non pressurised flat plate collector based solar water heating system with PUF insulated SS tank along with pre coaded clading covering the leaks by means of organ gas welding or brazing and re fixing the panel after testing the leaking all as specified and as directed.
Supply & Fixing in replacement of solar flat plate collector size 1mtr x 2 Mtr icluding testing all as directed by Engr in Charge.
Dismantling the complete assembly of solar hot water tank in replacement of supply and fixing 200 ltrs pre insulated hot water storage tank with stand (inner tank SS 304 ) removing insulated fixtures including all inlet outlet connections testing the leakages with compressed air, reshaping the squeezed portion of its original shape,filling of leak points with brazing /organ welding and reclading,connecting the removed water lines,testing of solar water tank all as specified and as directed.
Supply and fixing of 3KW Heater coil 230V, 50Hz including replacing the old unserviceable one all as specified and as directed.
Supply and fixing of Thermostat 230V, 50Hz including replacing the unsv one all as directed.
Supply and fixing of flange dummy-63mm dia including replacing the unserviceable one all as directed.
Supply and fixing of Gasket/rubber dummy-63mm dia including replacing the unserviceable one all as directed.
Supply and fixing of sacrificial anode 3/4 including replacing unserviceable one all as directed.
Supply and fixing of Hose clamp including replacing the old unserviceable one.
S&F High strength Calcium based granular chlorination chemical of following Specifications. Make: Declicab/Aquafit /PURI chlor (a) Chemical analysis and Physical observations:- Description:- White granules Granular size:- (Mess passing through-100 BSS): 1:1(+ 0.1%) Water/ Moisture: 5.00(+0.2)% Other insoluble Calcium salt:- 1.1(+0.1)% Mercury and other Heavy Metal contaminants:BDL.The chlorination chemical must contain appropriate quantities of dispersants/corrosion inhibitors to prevent encrustation/scaling in distribution systems (b) Strength of Items of quantity of chlorination chemical required to obtain free chlorine of 1 PPM per one lakh liters of water: Requirement must be 125-200 grams per one lakh liter of water to achieve 1 PPM Av.Cl at injection point( Site and raw water quantity variation may apply additionally) (c ) Stability:- Projected shelf life of chlorination chemical must be one year with minimal loss of chlorine (d) Handling of chlorination chemical for regular chlorination: (i)Operational considerations: Must be safe to use in terms of level of insoluble components. There must be no risks relating to encrustations in equipment and pipe lines, no sludge generation, no hard water scaling in supply water. (ii) Operator health considerations: Chlorination chemical must contains acceptable levels of granular size to avoid risks to operators from health safety point of view. (e) Safety & health hazard aspects on usages of chlorination chemical for regular drinking water chlorination: Mercury and other Heavy Metal contaminants in chlorination chemical must be Below Dectectable Limit(BDL),based on which the product must be considered safe to use from human health safety point of view and freedom from toxicity when used in drinking water chlorination in recommended dosage.
Material and labour for painting solar water heater including base structure complete with one coat of synthetic enamel paint including preparation of old painted surface complete all as specified.
Chemical and Bacteriogical analysis of water as per IS-1050,sample collected from borewells/shallow wells/BWSSB water /user point all as directed by Engr-in-Charge. Note- water to be tested once in 6 month and approved at NABL LAB.
Cleaning and removing of all scales and dirt etc from PVC/RCC/ tanks and from mouths of circulating pipes etc capacity not exceeding 500 Ltrs all as specified and directed by Engr-in-Charge.
All as per item No.36 but capacity exceeding 500 Ltrs and not exceeding 1000 Ltrs
All as per item No.36 but capacity exceeding 1000 Ltrs and not exceeding 2000 Ltrs
Repairing and maint of RO purifier cap 15 ltr/Hr complete.Each job includes servicing , checking and replacing the spare parts filters, motor, Chokes when required for every month. Monthly checking for any defects and rectifying if any for the RO purification of water filtering machine and also replacing filter complete whenever required all as specified directed by Engineer in Charge
Repairing and maint of RO purifier cap 80 ltr /Hr complete. Each job includes servicing , checking, replacing the spare parts filters, motor, chokes when required for every month.Monthly checking for any defects and rectifying the RO purification of water filtering machine ans also replacing filter whenever required complete all as specified directed by Engineer in Charge
Dismantling of PVC/RCC water tanks and S&F 500 Litres capacity PVC rotational moulded polyethylene water storage tanks (cylindrical vertical with closed tap) hoisted and fixed in position all as specified in SSR Part 1 .
All as per item No.40 but of capacity 1000 Ltrs
All as per item No.40 but of capacity 2000 Ltrs
All as per item No.40 but of capacity 5000 Ltrs
JyothsnaNursery
JM Engineering
devan enterprises
chowdeshwariconstructionco
RRK PROJECTS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .