| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.6 LAccepted-AOC 620 DIAMOND HARBOUR ROAD BEHALA INDUSTRIAL ESTATE PLOT NO F A KOLKATA 34 | KOLKATA | WEST BENGAL | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹24.0 L+₹34,975 (1.48%)Rejected-Finance | L2 | Rejected-Finance Higher bidder | |
| 3 | L3₹24.5 L+₹85,370 (3.61%)Rejected-Finance 11 CROOKED LANE KOLKATA 700069 | KOLKATA | KOLKATA | WEST BENGAL | 700069 | L3 | Rejected-Finance Higher bidder | |
| 4 | L4₹29.4 L+₹5.7 L (24.3%)Rejected-Finance GROUND FLOOR 8 NAWAB SIRAJ UD DAULA SARANI NEAR AMBER BAR AND RESTAURANT KOLKATA WEST BENGAL 700069 | KOLKATA | WEST BENGAL | 700069 | L4 | Rejected-Finance Higher bidder |
Tender Value
Refer Docs
EMD Value
₹56,000
Closing Date
27 Jan 2020, 1:00 pmClosed
Executive Engineer Paschim Med. Elecl. Div. PWDte
Office of the Executive Engineer, Paschim Medinipur Electrical Division, P.W.Dte. Paschim Medinipur.
Construction of a new office building and residence of Divisional Commissioner, Paschim Medinipur-----SITC of Air-Conditioning machines.(1st Retender)
2019_WBPWD_260922_2
WBPWD/EE/PMED/NIQ-33/e-T /2019-2020
Open Tender
ELECTRICAL WORKS ORG
Item Rate
21 days
Medinipur, Paschim Medinipur
Please refer Tender documents.
3 documents required · 3 mandatory
₹56,000
12 Feb 2026
10 Jan 2020
29 Jan 2020
10 Jan 2020
27 Jan 2020
10 Jan 2020
Amount
Supply & Delivery of split type fixed speed, Non-Inverter Air conditioning machine having the following specification :Rated EER: 3.57,Compressor Type: Rotary, Min. Cooling Capacity (Watts): 6600, Max. Power Input (Watts) : 1850, Airflow rate for indoor unit(CFM.): 777, Nano Platium filter, powerful cool and wide & long airflow Air Sleep Cooling Technology, LCD remote control, Electronic metal housing box, 12 hour on and off timer, auto restart, auto swing, fan speed option (low/medium/high) etc. Refrigerant-R410A. Min. BEE Star rating : 3 star,Min.Tonnage 2 TON [Make- Mitshubishi Heavy Industris, model no- SRK24CS-S6/A or eqv make of General/ Mitsubishi Electric-MS/MU-GK24VA.]
Installation, testing, commissioning of Above Mentioned 2 TR A.C. Machines complete with iron angle/powder coated Bracket MS angle base frame as per choice of EIC. including cutting of wall, making holes and mending good the damages
Supply and fixing the followings :- i) 3-Core, 2.5 Sq.mm. PVC insulated copper power wire for inter - connecting indoor and outdoor unit. ii) copper refrigerant pipe line for inter connecting indoor & outdoor unit as following size a) 5/8" copper pipe including thermal insulation of suitable thickness as per direction of E.I.C. iii) copper refrigerant pipe line for inter connecting indoor & outdoor unit as following size : b) 1/4 " copper pipe including thermal insulation of suitable thickness as per direction of E.I.C.
Supplying, fabrication & fixing 3Nos. M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) of 1m. length for making platform for installation of outdoor unit of 2 TR split AC incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm including supporting angle 50 mm x50mm x 6 mm in each platform in outer edge, for transmitting the load centrally through 2Nos.(50 mm x 50 mm x 6 mm) Angle inserted into the exiting wall. The entire platform should be baricaded & safe for ODU maintenance. Area of the platform is 3Mtr. x 1Mtr.
Terms and Condition:- 1) The Agency must procure the materials from the manufacturer/ OEM or from their authorized sales and channel so that the standard warranty/ support of the manufacture/ OEM becomes applicable to the products to be delivered and installed by them. 2) Documents that authenticates such procurement from the manufacturer/ OEM or from their authorized sales channel and standard warranty/ support should be send from the e-mail of the manufacturer/ OEM/ authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution of work/ submission of bill. 3) If any refurbished material is supplied and installed, penal action will be taken as per existing rules. 4) Rate should be quotated in including all taxes & GST.
NEW ENVIRONMENT CONTROL CO.
YOUNG ENGINEERING ENTERPRISE
Sunlight Electric Company
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .