Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 LAccepted-Finance RANIA SURYAKIRAN APARTMENT FLAT 404 BLOCK A NARAYANTOLA WEST KOLKATA 700 059 | 24 PARAGANAS NORTH | WEST BENGAL | 700059 | ₹2.5 L | L1 | Accepted-Finance L1 |
| 2 | L2₹2.5 L+₹7,340.42 (2.97%)Rejected-Finance 140 1 110 N S C BOSE ROAD REGENT PARK KOLKATA WEST BENGAL 700040 | KOLKATA | KOLKATA | WEST BENGAL | 700040 | ₹2.5 L+₹7,340.42 (2.97%) | L2 | Rejected-Finance L2 |
| 3 | L3₹2.5 L+₹7,439.28 (3.01%)Rejected-Finance | ₹2.5 L+₹7,439.28 (3.01%) | L3 | Rejected-Finance L3 |
Tender Value
₹2.5 L
EMD Value
₹4,943
Closing Date
17 Aug 2026, 10:00 amClosed
EE/MED
Office of the Executive Engineer Metropolitan Electrical Division Block-DF, Sector-I, 4th Floor, Jalasampad Bhawan, Salt Lake City, Kolkata -700091
Electrical renovation work incl. supplying and fixing of main switch, DB boxes, indoor and outdoor illumination system etc. at Dhosa Rest Shed, Mograhat Drainage Division, dist-South 24 Pgs. Under the jurisdiction of Metropolitan Electrical Division.
2026_IWD_1036557_8
WBIW/EE/MED/e-NIT-16/2026-27
Open Tender
ELECTRICAL WORKS ORG
Percentage
30 days
DHOSA, MOGRAHAT, SOUTH 24 PGS
Please refer Tender documents.
6 documents required · 6 mandatory
₹4,943
25 Aug 2026
8 Aug 2026
17 Aug 2026
8 Aug 2026
17 Aug 2026
8 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Distribution wiring in 1.1KV grade 2x22/0.3 (1.5 sqmm) single core straded "FR" PVC insulated & unsheathed copper wire (Brand approved by EIC) in sutable size PVC casing-capping (Precision make) with 1x22/0.30 (1.5 sq mm) single core standard FR PVC insulated and unsheathed copper wire for ECC incl. necessary fittings etc. to light/fan/call bell point with Modular type switch (Brand approved by EIC) fixed on Modular GI/PVC switch board with top cover plate on wall incl. mending good damages to original finish [only PVC casing-capping and switch board both on surface] | |||||
| 1.01 | Average run 5 mtr | 35 | POINT | 785.4 | ₹27,489 |
| 2Distribution wiring in 1.1KV grade 2x22/0.3 (1.5 sqmm) single core stranded "FR" PVC insulated & unsheathed copper wire (Brand approved by EIC) in sutable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5sqmm) single core straded "FR" PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. with S&F 6A 5 pin Modular type plug socket and switch (Brand approved by EIC) fixed on 4 Module GI/PVC switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works [PVC casing-capping and plug box both on surface.] | |||||
| 2.01 | On Board | 7 | POINT | 257.43 | ₹1,802.01 |
| 3Distribution wiring in 1.1KV grade single core stranded FR PVC insulated and unsheathed copper wire (brand approved by EIC) of following sizes in 25mm PVC casing capping (Precision make) including necessary PVC clips fittings etc. | |||||
| 3.01 | 2x22/0.3(1.5sqmm) + 1x22/0.3(1.5sqmm) | 30 | RM | 101.3 | ₹3,039 |
| 3.02 | 2x36/0.3(2.5sqmm) + 1x22/0.3(1.5sqmm) | 125 | RM | 121.56 | ₹15,195 |
| 3.03 | 2 x 56 / 0.3 (4 sqmm) + 1 x 36 /0.3 ( 2.5 sqmm) | 70 | RM | 157.32 | ₹11,012.4 |
| 4Supplying and drawing 1.1 KV single core standard FR PVC insulated and unsheathed single core stranded cu wire (Brand approvd. By EIC) of the following sizes in the pre laid polythene pipe and by the pre laid GI fish wire and making necy. connection as required. | |||||
| 4.01 | 4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC | 7.5 | RM | 587.56 | ₹4,406.7 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.60 MB
Tendernotice_2.pdf
PDF • 0.43 MB
BOQ_2546293.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .