| 1 | 1₹69.7 LAccepted-AOC A T ROAD CHABUA DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | 1 | Accepted-AOC ACCEPTED | |
| 2 | 2₹70.5 L+₹78,550 (1.13%)Rejected-Finance | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 3 | Rejected-Technical NO 16 7 739 3RD FLOOR OSMANPURA CHADERGHAT HYDERABAD TELANGANA 500 024 | HYDERABAD | HYDERABAD | TELANGANA | 500024 | - | Rejected-Technical NOT ADMITTED AS THE FIRM HAS NOT UPLOADED ANNEXURE I AND II AS DETAILED IN PARA 8 c of Appx A to NIT | |
| 4 | Rejected-Technical 535 UDYOG VIHAR PHASE V GURUGRAM HARYANA 122016 | - | Rejected-Technical NOT ADMITTED AS THE FIRM HAS NOT SUBMITTED DOCUMENTS AS PER PARA 8 b OF APPX A TO NIT TO FULL FILL THE ENLISTEMNT CRITERIA | |
| 5 | Rejected-Technical | - | Rejected-Technical NOT ADMITTED AS THE FIRM HAS NOT UPLOADED ANNEXURE I AND II AS DETAILED IN PARA 8 c of Appx A to NIT |
Tender Value
₹71.5 L
EMD Value
₹1.3 L
Closing Date
9 Dec 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Jorhat
HQ CWE(AF) JORHAT MES OFFICE NEAR ROWRIAH CHARALI 785004
PROVN OF WORKS FOR RECD AT AF STN CHBAU AND PASGHAT UNDER GE AF CHBAU
2024_MES_677923_1
84077/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
G E A F C H B A U
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE( AF) CHABUA
₹1.3 L
Yes
27 May 2025
4 Oct 2024
10 Dec 2024
4 Oct 2024
9 Dec 2024
3 Dec 2024
Amount
M&L Alteration Existing Emission System & Fixing of Exhaust Emission System of DG Set 100 KVA of Make : CUMINS, Engine Model No. : CJS100DPP, Alternator No. : NIOH 14654, Type : Water Cooled & Year of Manufacturing : 2010 and Providing New Retrofit for Emission Control Diesel Generator Emission Particulate Purification Device also known as Retrofit Emission Control Device (RECD) Equipment Reducing Diesel Particulate Matter and Other Emission Gases (excluding Civil, Cliding & Sub-main Wiring Works), complete all as specified and as directed.
M&L Alteration Existing Emission System & Fixing of Exhaust Emission System of DG Set 125 KVA of Make : KIRLOSKAR BLISS, Engine Model No. : 6KSWITC105, Alternator No. : XS431250-34, Type : Water Cooled & Year of Manufacturing : 2011 and Providing New Retrofit for Emission Control Diesel Generator Emission Particulate Purification Device also known as Retrofit Emission Control Device (RECD) Equipment Reducing Diesel Particulate MaMatter and Other Emission Gases (excluding Civil, Cliding & Sub-main Wiring Works), complete all as specified and as directed.
M&L Alteration Existing Emission System & Fixing of Exhaust Emission System of DG Set 160 KVA of Make : KIRLOSKAR, Engine Model No. : 400236, Alternator No. : 28535104L5144 Type : Water Cooled & Year of Manufacturing : 2005 and Providing New Retrofit for Emission Control Diesel Generator Emission Particulate Purification Device also known as Retrofit Emission Control Device (RECD) Equipment Reducing Diesel Particulate Matter and Other Emission Gases (excluding Civil, Cliding & Sub-main Wiring Works), complete all as specified and as directed.
M&L Alteration Existing Emission System & Fixing of Exhaust Emission System of DG Set 160 KVA of Make : KIRLOSKAR, Engine Model No. : GSL8800TAF63809, Alternator No. : 900469, Type : Water Cooled & Year of Manufacturing : 2009 and Providing New Retrofit for Emission Control Diesel Generator Emission Particulate Purification Device also known as Retrofit Emission Control Device (RECD) Equipment Reducing Diesel Particulate Matter and Other Emission Gases (excluding Civil, Cliding & Sub-main Wiring Works), complete all as specified and as directed.
M&L Alteration Existing Emission System & Fixing of Exhaust Emission System of DG Set 160 KVA of Make : KIRLOSKAR, Engine Model No. : XENSS00, Alternator No. : 4AB-28051, Type : Water Cooled & Year of Manufacturing : 2011 and Providing New Retrofit for Emission Control Diesel Generator Emission Particulate Purification Device also known as Retrofit Emission Control Device (RECD) Equipment Reducing Diesel Particulate Matter and Other Emission Gases (excluding Civil, Cliding & Sub-main Wiring Works), complete all as specified and as directed.
M&L Alteration Existing Emission System & Fixing of Exhaust Emission System of DG Set 180 KVA of Make : CUMINS, Engine Model No. : JSPF-180, Alternator No. : NIOF10872, Type : Water Cooled & Year of Manufacturing : 2010 and Providing New Retrofit for Emission Control Diesel Generator Emission Particulate Purification Device also known as Retrofit Emission Control Device (RECD) Equipment Reducing Diesel Particulate Matter and Other Emission Gases (excluding Civil, Cliding & Sub-main Wiring Works), complete all as specified and as directed.
M&L Alteration Existing Emission System & Fixing of Exhaust Emission System of DG Set 200 KVA of Make : KIRLOSKAR BLISS, Engine Model No. : 65L1500TA, Alternator No. : KC25461, Type : Water Cooled & Year of Manufacturing : 2008 and Providing New Retrofit for Emission Control Diesel Generator Emission Particulate Purification Device also known as Retrofit Emission Control Device (RECD) Equipment Reducing Diesel Particulate Matter and Other Emission Gases (excluding Civil, Cliding & Sub-main Wiring Works), complete all as specified and as directed.
M&L Alteration Existing Emission System & Fixing of Exhaust Emission System of DG Set 250 KVA of Make : KIRLOSKAR BLISS, Engine Model No. : GSL8800TAF63810, Alternator No. : 900470, Type : Water Cooled & Year of Manufacturing : 2009 and Providing New Retrofit for Emission Control Diesel Generator Emission Particulate Purification Device also known as Retrofit Emission Control Device (RECD) Equipment Reducing Diesel Particulate Matter and Other Emission Gases (excluding Civil, Cliding & Sub-main Wiring Works), complete all as specified and as directed.
M&L Alteration Existing Emission System & Fixing of Exhaust Emission System of DG Set 320 KVA of Make : KIRLOSKAR BLISS, Engine Model No. : DV88101/1520019, Alternator No. : GS3C014L193737, Type : Water Cooled & Year of Manufacturing : 2016 and Providing New Retrofit for Emission Control Diesel Generator Emission Particulate Purification Device also known as Retrofit Emission Control Device (RECD) Equipment Reducing Diesel Particulate Matter and Other Emission Gases (excluding Civil, Cliding & Sub-main Wiring Works), complete all as specified and as directed.
TECHNICAL SPECIFICATIONS : FOR ITEM No. 1 TO 9 (a) Type of Emission Device (Working Principle of PM Reduction Active Element) : Electrostatic Precipitation (ESP), Catalytic Conversion or Wet Scrubber (b) Emission Limits as per CPCB-II Norms : PM 2.5≤0.2 G/KW-Hr, Smoke Limit (Light Absorption Co-efficient ≤0.7m-1 (c) Particulate Matter Capturing Efficiency : Greater than 70% (d) Back Pressure on Engine : There should be no Back Pressure from RECD to Engine Exhaust System (e) Material of Construction : SS202 for Inlet Chamber, Outer Body coated MS (f) Emission Monitoring from Stack shall be Tested from any NABL approved Lab (g) RECD's Power Requirement : Less than 1% of Capacity used for Operation (h) Cleaning Mechanism : As per OEM (j) Noise Emission : No Increase in Noise Level after Installation of Retrofit Device.
NOTES : FOR ITEM No. 1 TO 9 (a) Output Result of the RECD should be as per CPCB-II Norms as applicable and the OEM/ Manufacture should have Valid type CPCB Approval Certificate. (b) The Quoted Unit Rate is inclusive of T&P Items such as Crane/ Hydra, etc. as required at Site of Work. (c) The Scope of Work includes Emission Control System with PRV, Inlet and Outlet Pipe and Electric Panel and all Accessories as required at Site of Work. (d) The Device should not have any Bye-Pass Arrangement. (e) DG Set shall be Tested on All Load Pattern as Available at Site during Post RECD Installation. (f) WARRANTY : The OEM shall provide Warranty of all respect for One Year Post Completion of Work/ Installation. (g) Contractor shall Furnish Manufacture's Written Instructions and Requirement about the Use and Maintenance of RECD System, its Operation and Maintenance Schedule. (h) Cost of all necessary arrangements requried for fixing of RECD as directed by the Engineer-in-Charge will deemed to be included in the Quoted Unit Rate.
M&L Sub-main Wiring with 2-Runs of 4.0 Sqmm (Nominal area) 1100 Volt grade PVC Insulated Unsheathed, Multi-stranded, Single Core FRLSH Copper Conductor Cable and 1-Run of 4.0 Sqmm (Nominal area) 1100 Volt grade PVC Insulated Unsheathed, Multi-stranded, Single Core FRLSH Copper Conductor Cable (Green Colour) as Earth Continuity Conductor drawn in and including Surface/ Recess PVC Casing Capping/ PVC Conduit (ISI Marked) of suitable Size (approx. 25/32mm Width/ Dia) alongwith all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc., complete all as specified and as directed. NOTE :- (a) Cost of 3-Runs of Cable & 1-Run of PVC Casing Capping/ PVC Conduit will deem to be include in the Quoted Unit Rate and the same will be Measured as ONE UNIT. (b) Sub-main Wiring will be measured PVC Casing Capping/ PVC Conduit only. Wires required for Looping, etc. will deem to be include in the Quoted Unit Rate.
M&L Sub-main Wiring with 2-Runs of 6.0 Sqmm (Nominal area) 1100 Volt grade PVC Insulated Unsheathed, Multi-stranded, Single Core FRLSH Copper Conductor Cable and 1-Run of 6.0 Sqmm (Nominal area) 1100 Volt grade PVC Insulated Unsheathed, Multi-stranded, Single Core FRLSH Copper Conductor Cable (Green Colour) as Earth Continuity Conductor drawn in and including Surface/ Recess PVC Casing Capping/ PVC Conduit (ISI Marked) of suitable Size (approx. 25/32mm Width/ Dia) alongwith all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc., complete all as specified and as directed. NOTE :- (a) Cost of 3-Runs of Cable & 1-Run of PVC Casing Capping/ PVC Conduit will deem to be include in the Quoted Unit Rate and the same will be Measured as ONE UNIT. (b) Sub-main Wiring will be measured PVC Casing Capping/ PVC Conduit only. Wires required for Looping, etc. will deem to be include in the Quoted Unit Rate.
Excavating in Trenches, not exc. 1.50 Metre Wide and not exc. 1.50 Metre in Depth; for Foundation, etc. or for Shafts, Wells, Cesspits, Manholes, Pier Holes, etc. not exc. 10 Sq m on Plan and not exc. 1.50 Metre in Depth and getting out in Soft/ Loose Soil, complete all as specified and as directed.
Removing Excavated Materials not exc. 50 Metre and Depositing where directed at a Level not exc. 1.50 Metre above the Starting Point, complete all as specified and as directed.
M&L Cement Concrete 1:3:6 (40mm graded stone aggregates) in Foundation, Filling and Mass Concrete, etc. including Use & Waste of Formwork as required/ ordered, complete all as specified and as directed. NOTE : Cost of Formwork will deem to be include in Quoted Unit Rate.
M/S P R SINGH AND SONS (BID ID -3184293)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .