GE (P) AF/GUR-64/2021-22 REPAIR/REPLACEMENT OF INTERNAL ELECTRIFICATION, CEILING FANS, EXHAUST FANS AND OTHER CONNECTED ITEMS IN MD ACCN IN SEKHON VIHAR AND REPAIR/MAINT OF EXTERNAL ELECTRIC, STREET LIGHT, SECURITY LIGHT, DG SET AND OTHER CONNECTED
2021_MES_487437_1
GE (P) AF/Gur-64/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (P) AF Gurgaon
All as per NIT
10 documents required · 10 mandatory
₹500
GE (P) AF Gurgaon
₹98,000
Yes
22 Dec 2021
10 Nov 2021
11 Dec 2021
10 Nov 2021
9 Dec 2021
25 Nov 2021
Amount
Taking down carefully point wiring of any type, size and description (light, fan, socket outlet etc.) including removal of battens, pipes, sockets, switches, ceiling roses, light fittings etc, complete and making good the disturbed surfaces to match with existing, all as specified and as directed.
Taking down main switches, distribution boards etc of any type and capacity along with the existing boards, and removing the same from site and making good the disturbed surfaces/portion of walls etc. all as directed.
Taking down old and unserviceable sub main wiring of any size and description and removable the same from site and making good the disturbed surfaces/portion of walls etc. all as directed.
M&L for concealed sub main wiring of two run with 04 Sqmm single core PVC insulated, FRLS, flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC conduit pipe 25 mm dia medium grade and accessories of suitable size and fixed on concealed surface of wall/ceiling with cutting chases for conduit including one run of 4.0 Sqmm single core PVC insulated, FRLS , flexible multi stranded copper cable as earth continuity conductor in green color all as specified and as directed.Note- (a) Two runs of single core cable with one run of earth continuity cable including PVC conduit and its accessories will be measured and paid as one unit.(b) Make disturbed surface good to wall/floors .
M&L for concealed sub main wiring of two run with 06 Sqmm single core PVC insulated, FRLS, flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC conduit pipe 25 mm dia medium grade and accessories of suitable size and fixed on concealed surface of wall/ceiling with cutting chases for conduit including one run of 6.0 Sqmm single core PVC insulated, FRLS , flexible multi stranded copper cable as earth continuity conductor in green color all as specified and as directed. Note- (a) Two runs of single core cable with one run of earth continuity cable including PVC conduit and its accessories will be measured and paid as one unit.(b) Make disturbed surface good to wall/floors .
M&L for sub main wiring complete using 2 run of 10 sqmm and one run of 10 sqmm, PVC insulated unsheathed FRLS multistranded copper conductor ISI marked 1100 Volt grade including concealed PVC conduit of medium grade ISI marked with accessories, through wall/ceiling including taking down and making good existing surfaces, complete all as specified and as directed by Engr-in-charge.
M&L for sub main wiring complete using Four run of 16 sqmm and one run of 16 sqmm, PVC insulated unsheathed FRLS multistranded copper conductor ISI marked 1100 Volt grade including through wall/floor/Panels with 25mm dia PVC flexible pipe including throuh taking down and making good existing surfaces, complete all as specified and as directed by Engr-in-charge.
M&L for sub main wiring complete using Four run of 25 sqmm and Two run of 25 sqmm, PVC insulated unsheathed FRLS multistranded copper conductor ISI marked 1100 Volt grade including through wall/floor/Panels with 32mm dia PVC flexible pipe including taking down and making good existing surfaces, complete all as specified and as directed by Engr-in-charge.
M&L for sub main wiring of two run with 04 Sqmm single core PVC insulated, FRLS, flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC casing-n-coping of size 25 x 16 mm medium grade and accessories of suitable size and fixed on wall/ceiling including one run of 4.0 Sqmm single core PVC insulated, FRLS , flexible copper cable as earth continuity conductor in green color all as specified and as directed.
M&L for sub main wiring of two run with 06 Sqmm single core PVC insulated, FRLS, flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC casing-n-coping of size 25 x 16 mm medium grade and accessories of suitable size and fixed on wall/ceiling including one run of 6.0 Sqmm single core PVC insulated, FRLS , flexible copper cable as earth continuity conductor in green color all as specified and as directed.
M & L for concealed point wiring complete with FRLS PVC insulated /unsheathed stranded copper conductor of wire 1.5 Sqmm , 1100 volt grade , alongwith one single core of same size stranded copper as continuous earth wire to common earth dolly in and including PVC conduit pipe fitting medium grade of 20 mm dia fixed in concealed surface of wall/ceilling/false ceilling including cutting /chasing in wall as required with powder coated sheet metal terminal boxes of required sizes and thickness (factory made) sunk in wall only with 3.0mm thick laminated sheet where as required and accessories complete suitable for the following :-
One light/fan point controlled by one on way switch
One socket outlet 05 Amps on the same board
One socket outlet 05 Amps on independent board
One bell/buzzer point controlled by on bell push
One light point controlled by two 2- way switches with cables 1.5 sqmm size.
-Ditto- as per item No. 11 above but point wiring with 2.5 Sqmm cable and 2.5 Sqmm earth continuity conductor for 3 pin 15 Amp socket and all as specified and directed.
M&L for point wiring complete with 1.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable 1100 volt grade, (FRLS) through and including 20X12 mm PVC casing-n- copping and its accessories, cadmium screws and including 1.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable(FRLS) as earth continuity conductor and MS boxes made of 16 gauge MS sheet concealed type on walls cover 3mm thick for housing the specified and directed for the following :-
One light/fan point controlled by one on way switch
One socket outlet 05 Amps on the same board
One socket outlet 05 Amps on independent board
One bell/buzzer point controlled by on bell push
-Ditto- as per item No. 13 above but point wiring with 2.5 Sqmm cable and 2.5 Sqmm earth continuity conductor for 3 pin 15 Amp socket and all as specified and directed.
Attending complaints related to internal electrification including replacement & minor repairs like reconnections, replacement of screw/washers any type & size, insulation tape replacement etc and obtaining completion of user on complaint slip, complete all as specified and as directed by engineer-in-charge. Contractor shall attend the complaints on requirement bases from 0900 to 1730 hours on working days including on non-working day also if required for that contractor shall deploy at least 02 semi skilled Electrician and one helper at Sekhon vihar residential complex (10 Blocks 10 storey bldg total 400 Officer+ 400 Servant Qtrs) for Day to day on all working day.The cost of said electricians and helpers shall be included in cost of attending complaints under this item and No extra payment on this account shall be given to the contractor.
S&F in replacement SPN 2 way sheet metal enclosures for flush/surface mounting distribution board Single door, 240 volts without bus bar complete all as specified and directed.
S&F in replacement SPN 4 way sheet metal enclosures for flush/surface mounting distribution board single door, 240 volts factory made and tested complete, suitable for mounting MCBs with 200 Amps rated bus bar, cable lugs complete all as specified and directed
S&F in replacement TPN 8 way sheet metal enclosures for flush/surface mounting distribution board single door, 415 volts factory made and tested complete, suitable for mounting MCBs with cable lugs complete all as specified and directed
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to 25x4 mm galvanised earth strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point including testing on completion and all excavation and earth work including taking out existing complete all as specified & as directed .
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion and all excavation and earth work including taking out old complete all as specified & as directed .
Taking down ceiling fan / exhaust fan / wall mountd fan any sweep from sealing cable end, dismantling blades and removing fan and blades to store and reassembling and refixing the fan after repairing/servicing complete all as specified and directed.
M&L for opening ceiling fan any type & any sweep, cutting the burnt winding, rewinding with super enamelled copper wire as per existing size and gauge with and including provision of insulating material varnishing with good quality varnish including replacement of all unserviceable parts such as safety pin, fan clamp with rubber bush, capacitor holder and twin core flexible copper wire etc complete all as specified and as directed by Engr-in-charge.
M&L for opening Wall fan any type, any make and of any sweep, cutting the burnt winding, rewinding with super enamelled copper wire as per existing size and gauge after providing all required insulating material varnishing with good quality varnish including replacement of all unserviceable minor parts such as safety pin, bearings, rotary switch with thread complete all as specified and as directed by Engineer-in-Charge.
M&L for opening of 400/450 mm sweep exhaust fan any type and any make cutting the burnt winding, rewinding with super enamelled copper wire as per existing size and gauge after providing all required insulating material varnishing with good quality varnish including replacement of all unserviceable minor parts such as safety pin, bearing, bush and capacitors complete all as specified and as directed by Engineer-in-Charge.
Note for Ser item Nos. 22.00 to 24.00 :- Replacement of any parts like capacitor, condensor, ball bearing, bushing and alike will be measured and paid seperately and rate also includes for cleaning, greasing, providing machine made screw, split pin etc alike complete.
M&L for painting to ceiling fan/Exhaust fan any sweep complete, in-situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc.complete.
Supply & Fix ventilating fan of PVC body type 200mm sweep complete all as specified and as directed by Engineer- in Charge. Make:- BAJAJ/ ORPAT/Philips
Supply Fix Wall fan PVC body type 300mm sweep complete all as specified and as directed by Engineer- in Charge. Make:- BAJAJ/ ORPAT/Philips
Supply Fix Ceiling Fan 1200mm sweep 3 blade single phase 5 star energy rating 230V 50 Hz complete with all accessories complete all as specified and as directed by Engineer- in Charge. Make:- BAJAJ/ ORIENT/ Philips
Supply & Fix Kitchen exhaust fan 300mm sweep metal body with front grill complete all as specified and as directed by Engineer- in Charge. Make:- Bajaj/ORPAT/ Philips
Supply & Fix in replacement of louvers for metal body 300 mm sweep exhaust fan for kitchen as per matching to existing complete all as specified and as directed by Engineer- in Charge.
Supply & Fix in replacement of copper wound Fan motor for exhaust Fan metal body 300mm sweep complete as per matching to existing type and gauge complete all as specified and as directed by Engineer- in Charge.
Supply & Fix in replacement of copper wound Fan motor for Ventilating Fan PVC body 200mm sweep with front lock & capacitor complete as per matching to existing type and gauge complete all as specified and as directed by Engineer- in Charge.
Supply and fix down rod 12mm dia made out of high density mild steel 300mm long as per approved sample.
M&L in replacement of nut and bolt (not less than 2.5 inches) and 0.25 inches dia with suitable size rubber reel for hanging of ceiling fan complete all as specified and directed.
M&L in replacement of PVC canopy of any size and shape suitable for existing ceiling fan make complete all as specified and directed.
M&L in replacement of blades of 1200mm sweep made of aluminium sutiable for ceiling fans complete all as specified and directed.
M&L in replacement of louvers suitable for 400/450 mm sweep exhaust fan complete all as directed.
Supply and fixing in replacement of fan stator with copper winding as per sample and make the ceiling fan serviceable all as specified and directed
Supply and fixing in replacement of fan stator housing with bearing as per sample and make the ceiling fan serviceable all as specified and directed
Supply and fixing in replacement of ceiling fan hanging clampwith rubber bush complete as per sample all specified and directed
M&L in replacement of metal flush box for fixing of switches for 1/2/3 module as per sample including all finishes all as specified. Make : Simon or equivalent as approved.
M&L in replacement of metal flush box for fixing of switches for 4 module as per sample including all finishes all as specified. Make : Simon or equivalent as approved.
M&L in replacement of metal flush box for fixing of switches for 6 module as per sample including all finishes all as specified. Make : Simon or equivalent as approved.
M&L in replacement of metal flush box for fixing of switches for 8 module as per sample including all finishes all as specified. Make : Simon or equivalent as approved.
Supply and fixing hylam sheet round corner of size as required at site, complete all as specified and as directed by Engr-in-Charge. Note:- cost of cuttung of hylam sheet is deemed to be fit in the quoted amount
M&L for opening and cleaning of existing kitchen exhaust fan including blades of any type any make with oil and dirt removing solution and refixing back to existing location complete all as specified and as directed by Engineer- in Charge.
Supply and Fixing in replacement of ceiling fan shaft and make the ceiling fan serviceable complete all as specified and directed.
S&F ISI marked electric energy meter single phase two wire LCD dispaly 5-30 Amps complete all as specified and as directed by Engineer- in Charge. Make:- HPL/BENTEC/ Secure.
S&F ISI marked electric energy meter three phase four wire LCD dispaly 10-60 Amps complete all as specified and as directed by Engineer- in Charge. Make:- HPL/BENTEC/ Secure
Supply and fixing on wall , Plug and socket in sheet steel enclosure with Single pole & earth , suitable for 20 Amp with providing MCB SP 20 Amp suitable for single phase AC supply complete all as specified and directed.
Supply and fixing in replacement of switch Modular one module one way 10 Amp complete all as specified and as directed by Engineer-in-charge.Make:- Simon cat part no.:- 381101-030 or equivalent from the make mentioned in list of make.
Supply and fixing in replacement of bell switch Modular one module 10 Amp complete all as specified and as directed by Engineer-in-charge.Make:- Simon cat part no.:- 381150-030 or equivalent from the make mentioned in list of make.
Supply and fixing in replacement of switch Modular one module two way 10 Amp complete all as specified and as directed by Engineer-in-charge.Make:- Simon cat part no.:- 381201-030 or equivalent from the make mentioned in list of make.
Supply and fixing in replacement of switch Modular one module one way 16 Amp complete all as specified and as directed by Engineer-in-charge.Make:- Simon cat part no.:- 381111-030 or equivalent from the make mentioned in list of make.
Supply and fixing in replacement of Modular type socket outlet shuttered two module combined 6/16 amps multipurpose complete all as specified and directed by Engineer-in-charge.Make:- Simon cat part no.:- 382426-030 or equivalent from the make mentioned in list of make.
Supply and fixing in replacement of Modular type socket outlet shuttered two module 5 pin 6 amps multipurpose complete all as specified and directed by Engineer-in-charge.Make:- Simon cat part no.:- 382427-030 or equivalent from the make mentioned in list of make.
Supply and fixing in replacement of Modular Electronic Fan regulator 5 stepped type 02 module complete all as specified and as directed by Engineer-in-charge. Make:- Simon cat part no.:- 382315-030 or equivalent from the make mentioned in list of make.
Supply and fixing in replacement of Modular Electronic Fan regulator 4 stepped type 01 module complete all as specified and as directed by Engineer-in-charge. Make:- Simon cat part no.:- 382314-031 or equivalent from the make mentioned in list of make.
Supply and fixing in replacement of Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings. Make : Anchor/Cona/Havells.
Supply and fixing in replacement of 3 pin 05 Amps switch socket combination, box type multipurpose 2 in 1 type (3 pin 5 Amps ) all as specified and directed. Make : Anchor/Cona/Havells.
Supply and fixing in replacement of 3 pin 15 Amps switch socket combination, box type multipurpose 2 in 1 type (3 pin 5 Amps and 15 Amps) all as specified and directed.Make : Anchor/Cona/Havells.
S&F in replacement of MCB, including making connections to DB with providing appropriate size of copper thimbles as per site reqmt for the following all as specified and directed.
S & F MCB SP of rating, 06 to 32 Amp,240 volt, 10 KA 'B' Series. Make : Indoasian/Havells/L&T
S & F MCB SP of rating, 40 Amp,240 volt, 10 KA 'B' Series .Make : Indoasian/Havells/L&T
S & F MCB SNP of rating 06 to 32 Amp, 240 Volt, 10 KA, 'C' series. Make : Indoasian/Havells/L&T
S & F MCB SPN of rating 40 Amp, 240 Volt, 10 KA, 'C' series.Make : Indoasian/Havells/L&T
S & F MCB SPN of rating 63 Amp, 240 Volt, 10 KA, 'C' series.Make : Indoasian/Havells/L&T
S & F MCB TPN of rating 63 Amp, 415 Volt, 10 KA, 'C' series.Make : Indoasian/Havells/L&T
S & F MCB TP of rating 63 Amp, 415 Volt, 10 KA, 'C' series. Make : Indoasian/Havells/L&T
S & F 40 Amps RCCB A-type (TPN-4M) 240/415 Volt, 50 Hz , 10 KA short circuit capacity and breaking capacity 100 mA.Make : Indoasian/Havells/L&T
S & F 63 Amps RCCB A-type (TPN-4M) 240/415 Volt, 50 Hz , 10 KA short circuit capacity and breaking capacity 100 mA. Make : Indoasian/Havells/L&T
S&F in replacement of metal clad plug 20A 2P+E, 230V AC , complete all as specified and as directed by Engr-in-Charge. Make:- Indoasian cat part no:- 810386
S&F in replacement of metal clad socket 20A 2P+E, 230V AC , complete all as specified and as directed by Engr-in-Charge. Make:- Indoasian cat part no:- 810390
Supply only 12 watt ball type LED lamp, 230 volt suitable for recess mounting light fittings. Make:- Havells/Orient/ Bajaj/Philips/CG/Syska
S&F 4 ft 18/20 watt Decorative ultra slim aluminium LED lighting fixture with high lumen output, environmental friendly, energy complete all as specified and by Engr-in-charge. Make:- Havells/Orient/ Bajaj/Philips/CG
S&F in replacement of 2 feet 09 W slim LED battern (cool day light) Basic all purpose surface and wall mounted with polycarbonate housing & integrated with electronic driver..Make:- Havells/Orient/ Bajaj/Philips/CG
S&F in replacement of Decorative wall light fixture made up of Polycarbonate, suitable for 9W LED Lamp B22 base complete with all accessories as per sample , complete all as specified and as directed by Engr-in-Charge.Make: Havells /Orient/Syska
S&F in replacement 36 W LED recess mounting fitting(2' x 2') CRCA powder coated having polycarbonate diffuser powedered by independent electronic LED driver haing IP 20 protection,CCT 6000 K,230/240 VAC,lumen efficacy > 140 lm/w including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified and as directed.Make:- Havells/ Philips/ GE/Bajaj
M&L in replacement of fan capacitor/condensor 1.5 MFD, 240 volt of ceiling fan/exhaust fan/wall mounted fan.Make : Tibcon/Havells
M&L in replacement of fan capacitor/condensor 2.5 MFD, 240 volt of ceiling fan/exhaust fan/wall mounted fan.Make : Tibcon/Havells
M&L in replacement of fan capacitor/condensor 3.15 MFD, 240 volt of ceiling fan/exhaust fan/wall mounted fan. Make : Tibcon/Havells
M&L in replacement of fan capacitor/condensor 4.0 MFD, 240 volt of exhaust fan. Make : Tibcon/Havells
Supply only in replacement of Ding dong call bell , complete all as specified and as directed by Engr-in-Charge.
Dismantling of PT pump assembly from DG set of Make - Cummins /Ruston/Kirloskar engine for repair, cleaning, servicing, overhauling of pump assembly with necessary calibration including replacement of spares parts, complete all as specified and directed by Engineer-in-Charge.
Taking out unservicable self starter 12/24 volt from the DG Set, transportation to workshop opening/disconnecting all internal connection, cleaning the same taking out burnt armature, segregation serviceable parts for re-use, rewinding of armature with existing size of copper wire. Reassembling the same with replacement of carbon brush 01 set, Beadex pinion 01 no, Half clutch assy 01 No, Field coil 01 No, solonoid switch 01 No., commutator 01 nos, fixing the self starter on the engine at site and testing, complete all as specified and directed by Engineer-in-Charge.
Dismantling of starting system of 400/250 KVA DG set including necessary wires and supply and fixing starting system with maint free lead acid battery 12 V ,180 AH. Make Exide with copper terminal cable of 25 Sqmm single core approx length 1.5 Mtr each for negative and positive terminal and 0.5 mtr for inter connection including necessary brush terminals complete of DG set including testing, complete all as specified and directed by Engineer-in-Charge.
Dismantling of starting system of 82.5/63/40/25KVA DG set including necessary wires and supply and fix starting system of maint free lead acid battery 12 V ,150 AH. Make Exide with copper terminal cable of 25 Sqmm single core approx length 1.5 Mtr each for negative and positive terminal including necessary brush terminals complete of DG set including testing, complete all as specified and directed by Engineer-in-Charge.
Dismantling of injector of any DG Set in 13 BRD & 16 BRD for repair, cleaning of and overhauling of the same with necessary calibration including replacement of necessary parts as required, complete all as specified and directed by Engineer-in-Charge. Note : spares parts required shall be measured under separate item).
Supply only Injector kit assembly complete all as specified and directed by Engineer-in-Charge.
Labour only for the inspection of DG set 25 to 82.5 KVA in 13 BRD area, without stripping of any parts, by rep of OEM or technical expert approved by Engr-In-Charge, and isolating any defects after cleaning of entire DG Set with compressed air jet and vaccum cleaner and wiping the entire DG set outer surface with DHPPN including taking out greased and dust accumulation in restricted corners to bring the surface to a shiny presentable look all as directed by Engr-In-Charge complete and servicing of the complete DG Set including setting of valve timing and replacement of spare parts as required including testing for serviceability of wires and replacement wrerever required, testing complete all as specified and as directed. (Note: Spares required shall be measured and paid seperately)
Labour only for the inspection of DG set 200 to 400 KVA in 13 BRD & 16 BRD area, without stripping of any parts, by rep of OEM or technical expert approved by Engr-In-Charge, and isolating any defects after cleaning of entire DG Set with compressed air jet and vaccum cleaner and wiping the entire DG set outer surface with DHPPN including taking out greased and dust accumulation in restricted corners to bring the surface to a shiny presentable look all as directed by Engr-In-Charge complete and servicing of the complete DG Set including setting of valve timing and replacement of spare parts as required including testing for serviceability of wires and replacement wrerever required, testing complete all as specified and as directed. (Note: 1. Spares required shall be measured and paid seperately. 2. Contractor shall provide spares as per sample and existing make)
Supply only the following Parts for incorporated to the items No.92 &93 here-in-before complete all as specified and as directed by Engr-in-charge (Make - Kirloskar):-
Spring washer
Binjo screw injector
Set of flexible fuel pipe
O' ring injector
Set of copper washer
Fuel filter elements set pre mico
Set of belts
Disposalable oil filter elements
Set of Hoses
Air filter complete.
Set of hoses clips
Complete set of gasket
Rubber hose
Washer cranks case
Fuel pipe
Hex screw tappet cover
Hex screw oil sump
Allen screw
Tappet adjusting screw
cooling water pipe
Taking out burnt lubricating oil from existing DG Set of any capacity and supply & filling 20 W 40 lubricating oil grade as required at site, complete all as specified and directed by Engineer-in-Charge. Make - HP/Castrol
Supply , filling and toping up coolant in DG set of any capacity, complete all as specified and directed by Engineer-in-Charge. Make - HP/Castrol
M&L for repair/replacement of radiator set complete with taking out of rusted out parts like coils, tanks hose pipes, fan belts, fan blade complete and replacing them as per existing make and specification complete all as specified and as directed by Engineer in charge.
M&L for painting to the DG Set of 40 to 400 KVA capacities by applying Ist grade synthetic enamell spray duco paint in existing colours including fuel tank foundation base ,canopy and panel board and cleaning & removing of existing rust grease oil spot etc and preparation of surfaces, complete all as specified and directed by Engineer-in-Charge. Make : Berger/Asian
M&L for attending to unserviceability of DG Set on call, and detecting the fault of any capacity of DG Sets and at any location by providing skilled trademan & helper with necessary safety and working equipment such as ,multimeter ,speedometer and other reqd tools and plants and rectification of the defects to make it serviceable, on top priority as and when reqd including testing, complete all as specified and directed by Engineer-in-Charge.
Supply and incorporation of distilled water for lead acid battery, complete all as specified and directed by Engineer-in-Charge.
M&L for AMF relay digital type with LED screen suitable capacity of CTs for 200/250/400 KVA DG set complete all as directed and specified by Engr-in-charge.
S & F in replacement of first aid box containing medical kits all as specified and as directed.
S & F in replacement of electric shock treatment board made up of flux sheet with printed standard matter in two versions(i.e Hindi & English ) standrad drawing over a layer of polythene film pasted on wooden ply board of 6 mm thick with all edges fixed with wooden beedings all as directed. Note:- The over all size of the board shall not less than 1.0 Mtr x 0.75 Mtr
Supply and fix in replacement of LED indicating lamp (Red ,Blue & Yellow) complete all as specified and directed.
M & L for Servicing of servo controlled voltage stabilizer of capacity 300 to 400 KVA, 415 volt including setting of input and output voltage and necessary testings complete all as directed by Engineer-in-charge.Note:- Spare required for replacement if any will be measured and paid separately.
Supply only the following Parts for incorporated to the items No.105 here-in-before complete all as specified and as directed by Engr-in-charge (Make - As per sample or existing make):-
Shunt Trip coil of any size
Cut out PCB,3-phase
Micro-controller PCB with connector
control cabling with glass fuse
Indication lamp, 22.5 mm dia, R - Y- B
Push button,12.5 dia,R -Y-B
Voltmeter,Analog type ( 0 - 300 V),
Single phase , Synchronise AC motor, 10 KG
RC network for 10 KG motor
Sensing Transformer for Digital/analog control
Aluminium Busbar of any size and any capacity.
Stabiliser carbon Brush for Dimmer
M&L for complete earthing with galvanized mild steel earth plate electrode 600x600x6mm thick buried directly in ground ( in vertical position ) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5mtr (B.G.L.) and connected to galvanized iron earth strip 32x6mm by means of bolts, nuts, check nuts and washer of galvanized iron including PCC(1:2:4) type B1 precast RCC cover slab with suitable handle made of 12mm round bar, including necessary excavation & earth work in any type of soil. 20mm dia med gde galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 40 mm dia bore, light grade galvanized steel tubing up to 7.5 mtr length for drawing earth lead wire protection common salt, charcoal etc complete all as shown in EP No 3 of SSR Part 1 and testing on completion, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing GI strips of size 32mm x 6mm including all fixing arrangement such as clamps,MS screws,saddles,PVC gutka,GI Nut bolt & washers etc complete all as specified and directed by Engineer-in-Charge.
M&L for set of Chemical/GEM/GEL Earthing system with earth electrode of for copper bonded low carbon steel core of 3 meter long having outer dia 80mm & inner dia 50mm duly filled with highly conductive and anti corrosive compound of required quantity with chemical composition Bentonite 40%, Copper sulphate 10%, Gypsom 5%, Graphite 10%, Alum 5%, Zinc sulphate 10%, Aluminium sulphate 10%, buried directly in ground ( 150-175 mm dia digging or auguring of earth to the required depth as specified by manufacturer and directed ) and pit filled up with GEL form of Electrolytic and Moisture retention type Earthing tested for less than 1 ohm Resistivity and connected with copper strip (32x6mm) to rod connected by means Given Terminal point with copper Nut Bolts, provision of ready made polymer chamber with cover, including necessary excavation in any type of soil, returning filling in, removal of surplus soil complete all as specified and as directed. (Makes: Pittas, RPG,HSL Industries, Roksna, Furse)
Note: 1. Earthing pit locations shall be identified as per IS-3043 prior to start the work and make to be approved by GE. 2. Earthing system shall be designed so as to achieve test result less than 0.50 Ohms by making an arrangement of minimum 4 Electrodes By interconnecting with copper Strip to make a parallel connection to achieve the required ohmic value. 3. Copper strip to be extended upto the equipment and power room. It shall be routed in the side wall of the under ground ducts fixed with ceramic/porcelain/PVC spacers . 4. Ready made polymer chamber with cover of suitable size shall be provided directly. 5. Copper strip shall be of 32x6mm as directed above upto test point max upto 7.50mtr is included in quoted rate of earthing. 6. Authorized manufacturer gurranty certificate is mandatory for two years maintanance free with result shall remains below 1.0 Ohms.
Supply and fixing of test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 nos.8mm dia 25 mm long hex .head screw fixed inside cubical shape enclosure made out CRCA sheet 2.0 mm thick with front detachable cover, anodized fixing screws, cap washers 4 nos to be mounted on wall with wooden plugs & screws 4 nos, duly painted inside and outside by two coat of aluminium paint over a coat of primer, over all dimension of enclosure200mm x 150mm x 100mm (depth) complete all as directed.
M&L for tightning of earthing strip Al/copper of any size by using screws and porcelin insulators on roof, floor and wall including protection pipe complete all as specified.
Supply and fixing copper strips of size 32mm x 6 mm all fixing arragement such as clamps/MS screws/saddles/ PVC gutka/Brass Nut bolt/Porcelain insulator & washers etc complete all as specified and directed .
Supply and fixing copper strips of size 20mm x 3 mm all fixing arragement such as clamps/MS screws/saddles /PVC gutka/Brass Nut bolt/Porcelain insulator & washers etc complete all as specified and directed .
S&F in replacement of lightning conductor air termination, single pointed copper rod 12 mm dia and 300 mm long including fixing of MS clamps with nuts & bolts and screws all as specified and directed .
M & L for testing of earth resistance value of existing earthing pits once in a month with digital type earth tester up to the entire satisfaction of Engr-in-charge Note:1) The contractor should report with in two days after intimatation to carry out the Earth Test as a whole or partially of the building. 2) Earth testing will be done in monthly basis. 3) Each month of each earthing measured seprately.4) Necessary T&P will be provided by the contractor for testing of earth resistance.
Repairs of earth pit cover/chambers with necessary PCC1:2:4 work ,brick work & excavation all as directed and specified by the Engr-in-charge and levelling/returning filling of earth surface.
M&L for treatment of existing high resistance earthing pit by pouring of salt water solution made of 20 ltrs of water and 5 Kg of salt in the trench to be prepared all around the existing earth pit with radious 60 cm from the centre of the earth pit to the centre of the trench with a depth not less than 30 cm below ground level all as directed and specified by the Engr-in-charge and levelling/returning filling of earth surface.
M&L for jointing copper strip with each other by brazing complete and making the joint smooth and proper by rubbing with emery paper to give a proper surface finish all as directed by Engr-in-Charge.
S&F chequered rubber matting of black colour (ISI marked) 11 KV rating 25 mm thickness complete all as specified and directed.
M&L for Complete for Mild steel duct cover 5mm thick chequered with 10mm dia MS bar lifting handle, etc all as specified and directed..
Taking out of U/S MCCB s of any type any capacity by disconnecting all electrical connections from Panel board/wall/FPB all as directed at site comple all as directed.
S&F in replacement of MCCB 4 pole 63 A, fixed type, breaking capcaity 16KA fixed in LT panels, complete all as specified and as directed by Engr-in-charge. Make Legrand /schiender/siemens
S&F in replacement of MCCB 4 pole 100 A, fixed type, breaking capcaity 16KA fixed in LT panels, complete all as specified and as directed by Engr-in-charge. Make Legrand /schiender/siemens
S&F in replacement of MCCB 4 pole 160 A, fixed type, breaking capcaity 25KA fixed in LT panels, complete all as specified and as directed by Engr-in-charge. Make Legrand /schiender/siemens
S&F in replacement of MCCB 4 pole 200 A, fixed type, breaking capcaity 25 KA fixed in LT panels, complete all as specified and as directed by Engr-in-charge. Make Legrand /schiender/siemens
S&F in replacement of MCCB 4 pole 250 A, fixed type, breaking capcaity 36KA fixed in LT panels, complete all as specified and as directed by Engr-in-charge. Make Legrand /schiender/siemens
S&F in replacement of MCCB 4 pole 400 A, fixed type, breaking capcaity 36KA fixed in LT panels, complete all as specified and as directed by Engr-in-charge. Make Legrand /schiender/siemens
S&F in replacement of MCCB 4 pole 630 A, fixed type, breaking capcaity 36KA fixed in LT panels, complete all as specified and as directed by Engr-in-charge. Make Legrand /schiender/siemens
M&L for disconnection of power supply to High mast lamp and dismantling the section of high mast 16/20 mtr hegiht including fittings complete by manually / hydra at AF station Palam for servicing, repair of gear motor including rewinding and replacement of rope,chain and service cable etc all as specified and directed or Refixing of the same if rendered serviceable by Engr-In-Charge, all as specified and as directed and testing complete.(Note: Spares required shall be measured and paid seperately)
M&L in replacement of Steel rope multistranded, suitable for high mast not less than 10mm thickness all as specified
M&L in replacement of Chain system suitable for running in pinion at site of individual high mast pole all as specified
M&L in replacement of Service cable PVC insulated sheathed with multistranded aluminium conductor 6.00 Sqmm three core complete all as specified and as directed
Dehydration of tranformer oil, obtained from transformers/ voltage stabilizer etc. Dielctric strength shall not be less than 40 KV in 2.5 mm gap electrode after dehydration. Dehydration of transformer shall be carried out by using electrically operated dehydration machine including necessary load testing after topping up of transformer oil and replacement of slica gel complete all as directed. Note:-- Transformer oil for filling/toping up and Silica gel shall be measured and paid against respective item.
Taking out burnt winding from DG set alternator /Transformer/ Stabilizer of any make and capacity by using special T&P and repair the same by rewinding with super enameled copper wire as per existing gauge (DPC) as per requirement including varnishing and using necessary insulations testing after completion of repair work complete all as specified and directed. Note : 1. Cost of loading/lifting and transportation is deemed to fit in the quoted rates. 2. Any type of damages occurred during the repair work will be repaired by the contractor without any extra payment
M&L for topping up of transformer oil of dielectric strength 40 kv and above in transformer at different loaction in situ (testing of oil shall be carried out in prensece of Engr in charge by an authorised agency and testing certificate shall be submitted duly signed.
Repairs to transformer step down 11/0.433 KV, of any capacity at existing position of pole mounted or platform duly disconnection of HT/LT cable connection, earthing lead, and shifting to work shop if required,opening of transformer cover plate, taking out of transformer oil and kept in clean and dry container for re-use the same and after repair of lekage the same including replacement of unserviceable items such as gaskets, HT/LT bushing set, nuts, bolts and reconnection the same including testing all as directed and specified by the Engr-in-Charge
Taking down existing old LT panel board/ LT feeder pillar box comprising of MCCB & switch fuse unit of any capacity and size including bus bar, ammeters, voltmeters etc after disconnecting all cable connection and removing from site complete all as directed.
OUTGOING:- (i) MCCB , AC 415 volts, 3 pole current rating 200 Amps, breaking capacity 36KA= 02No’s Make- legrand/siemens/schiender (ii) MCCB , AC 415 volts, 3 pole current rating 160 Amps, breaking capacity 36KA= 01 No’s Make- legrand/siemens/schiender (iii) MCCB , AC 415 volts, 3 pole current rating 125Amps, breaking capacity 25 KA= 06 No’s Make- legrand/siemens/schiender (iv) spare blanking way for one No,s extra out going MCCB = 01 No
M&L for Pole mounted, Loop In-Out Junction Box fabricated complete with Thermoplastic Polycarbonate Insulated material for junction box with glass fiber reinforced. The Polycarbonate junction box shall be environment friendly, recyclable, UV resistant, halogen & silicon free, anti acid& anti corrosive, IP 66 in accordance with IEC 60529. The gasket material shall be Polyurethane and the gasket shall be internally embedded.The junction box shall be complying the standards IEC 60670 – 1 & IEC 60670 – 22. The manufacturer of Junction Box / Enclosure shall submit a copy of IEC Certificate. For better safety the Polycarbonate enclosure shall be fire retardant & self-extinguishing in accordance with IEC 60 695-2-1, DIN VDE 0304 Part 3, UL Subject 94 for Flammability V-2. It should be tested at Glow Wire test for 960ºC and the impact strength of polycarbonate enclosures / boards i.e. the Degree of Protection against Mechanical load shall be in accordance with EN 50298-98 for IK 08.(Make: HENSEL/Spelsgeberg/Syntex) Size – (205 x 255 x 112) mm Cat part No – KF2500B of HENSEL or equivalent of Spelsgeberg/ Syntex Colour – Black Internals – 4 Pole Terminal Suitable upto 25 sq mm along with one 6ASP MCB Cable Gland – Size M32 - 2 nos ( cat no 1555.32.25 + 8232) of HENSEL or equivalent of Spelsgeberg/ Syntex Size M25 – 1 no ( cat no 1555.25.17 + 8225) of HENSEL or equivalent of Spelsgeberg/ Syntex
Demolition of cement concrete of any description and in any position carefully cutting by chiseling as reqd holes (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
M&L for brick work with old size bricks straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
M&L for Providing, cement concrete for coping of poles 1:2:4 type B 0(12.5 mm graded aggregate) complete all as specified and directed.
M&L for rendering 15 mm thick of brick work or concrete surfaces in CM 1:4 finished even and fair surfaces without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Notes:- (a) The amount of Rs 267624.00/- against Schedule of Credit on Page No. 131 & 132 (R) shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance. (b) Any material required to be replaced for complaint rectification other than screws, PVC rawl plug, nuts & bolts, insulation tape, thimbles and as specified in complaint item shall be measured and paid seperately under respective supply only item. (c) The cost of attending complaints shall also include the cost of stationery required for recording complaint, complaint slips and its reports as directed by Engineer-in-charge. (d) All the complaint registered (except point wiring / sub-main wiring and connected S&F items) before 1000 Hrs of every day shall be rectified on same day upto 1700 Hrs. Any delay in complaint rectification a penalty shall be recovered @ Rs.100/ per complaint per day. (e) The items supplied by contractor as supply only shall be taken on charge by deptt. and shall be issued to contractor's trademen for incorporation against the complaints slips under item No 15 hereinbefore and proper records of same shall be maintained. (f) All T&P required by electrician for complaint rectification shall be provided by the contractor at his own cost. (g) Any desturbed surface during execution of work shall be made good as existing. Nothing extra shall be paid in this respect. The quoted rate are deemed to be included the same cost.
Deep Contractor
SM CONSTRUCTION COMPANY
Bidder Name
SM CONSTRUCTION COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .