Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.6 LAccepted-AOC 1 NEAR AKBARIYA MASJID WIMBERLYGUNJ SOUTH ANDAMAN ANDAMAN NICOBAR 744206 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744206 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹38.9 L+₹1.8 L (4.72%)Rejected-Finance 24 824 GOVERDHAN COLONY MAIN BHIND ROAD GOLE KA MANDIR | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹42.9 L+₹5.8 L (15.6%)Rejected-Finance | L3 | Rejected-Finance Not Lowest |
| Sl No | Description | Qty | Unit | TIMES HYDRO-ELECTRIC COMPANY L3 | ANAND ENTERPRISES L2 | SBS Enterprises L1 |
|---|---|---|---|---|---|---|
| 1.00 | Maintenance and servicing to DG set once in a month including attending faults on call basis for normal repairs including replacement of defective and worn out minor filters gaskets, V- belts, Engine oil, rubber hoses, worm drive clamps, nuts, bolts and cleaning of alternator with vaccum cleaner and attending faults of AMF panels etc, tappet settings if required and greasing of bearings of engine and alternator, checking of batteries, applying petroleum jelly to battery terminals, adding distilled water checking the oil, coolent levels of capacity 380 KVA DG set installed at Southern Command Signal Centre complete all as specified and asdirected by Engr- in- Charge.
Note:- (i) Spares required for maintenance will be measured and paid seprately under relevant items. (ii) Servicing to be carried out as per manufacturer’s specifications/ instructions (iii) The work of maintenance shall be carried out through respective authorized dealer whose certificate shall be produced to Engineer - in - charge (iv) Proper record & test results of the same shall be maintained as directed (v) Work shall be carried out at site at different location | 11 | Per Month | 3,300 ₹36,300 | 2,500 ₹27,500 | 2,000 ₹22,000 Lowest |
| 2.00 | All as per serial item No.1.00 here-in-before but capacity 250 KVA DG set installed at PCDA Southern Command. | 11 | Per Month | 2,400 ₹26,400 | 2,500 ₹27,500 | 2,000 ₹22,000 Lowest |
| 3.00 | All as per serial item No.1.00 here-in-before but capacity 200 KVA DG set installed at Old Telephone Exchange. | 11 | Per Month | 2,400 ₹26,400 | 2,500 ₹27,500 | 2,000 ₹22,000 Lowest |
| 4.00 | All as per serial item No.1.00 here-in-before but capacity 200 KVA DG set installed at SC Signal Centre. | 11 | Per Month | 2,400 ₹26,400 | 2,500 ₹27,500 | 2,000 ₹22,000 Lowest |
| 5.00 | All as per serial item No.1.00 here-in-before but capacity 200 KVA DG set installed at Sewage Treatment Plant. | 11 | Per Month | 2,400 ₹26,400 | 2,500 ₹27,500 | 2,000 ₹22,000 Lowest |
| 6.00 | All as per serial item No.1.00 here-in-before but capacity 160 KVA DG set installed at PCDA Pump House. | 11 | Per Month | 2,220 ₹24,420 | 2,500 ₹27,500 | 1,800 ₹19,800 Lowest |
| 7.00 | All as per serial item No.1.00 here-in-before but capacity 125 KVA DG set installed at SCOM Pump House. | 11 | Per Month | 2,220 ₹24,420 | 2,000 ₹22,000 | 1,800 ₹19,800 Lowest |
| 8.00 | All as per serial item No.1.00 here-in-before but capacity 125 KVA DG set installed at Star Auditorium. | 11 | Per Month | 2,220 ₹24,420 | 2,000 ₹22,000 | 1,800 ₹19,800 Lowest |
| 9.00 | All as per serial item No.1.00 here-in-before but capacity 125 KVA DG set installed at Old telephone exchange. | 11 | Per Month | 2,220 ₹24,420 | 2,000 ₹22,000 | 1,800 ₹19,800 Lowest |
| 10.00 | All as per serial item No.1.00 here-in-before but capacity 110 KVA DG set installed at Old telephone exchange. | 11 | Per Month | 1,500 ₹16,500 Lowest | 2,000 ₹22,000 | 1,500 ₹16,500 Lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
13 Sept 2025, 6:00 pmClosed
GE NORTH PUNE
Garrison Engineers Office (North) General Cariappa Marg, Pune-01
GE (N) P/TOKEN- 28 OF 2025-2026 REPAIRS AND MAINTENANCE TO DG SETS AND AMF PANELS ALONGWITH ALLIED WORKS IN THE AOR OF AGE E/M (NORTH) UNDER GE (N) PUNE
2025_MES_723069_1
GE (N) P/TOKEN- 28 OF 2025-2026
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
GE NORTH PUNE
Refer tender documents.
8 documents required · 8 mandatory
₹500
GE NORTH PUNE
₹80,000
Yes
28 Jan 2026
28 Jul 2025
16 Sept 2025
28 Jul 2025
13 Sept 2025
11 Aug 2025
29 Jul 2025 - 5 Aug 2025
Amount
Maintenance and servicing to DG set once in a month including attending faults on call basis for normal repairs including replacement of defective and worn out minor filters gaskets, V- belts, Engine oil, rubber hoses, worm drive clamps, nuts, bolts and cleaning of alternator with vaccum cleaner and attending faults of AMF panels etc, tappet settings if required and greasing of bearings of engine and alternator, checking of batteries, applying petroleum jelly to battery terminals, adding distilled water checking the oil, coolent levels of capacity 380 KVA DG set installed at Southern Command Signal Centre complete all as specified and asdirected by Engr- in- Charge. Note:- (i) Spares required for maintenance will be measured and paid seprately under relevant items. (ii) Servicing to be carried out as per manufacturer’s specifications/ instructions (iii) The work of maintenance shall be carried out through respective authorized dealer whose certificate shall be produced to Engineer - in - charge (iv) Proper record & test results of the same shall be maintained as directed (v) Work shall be carried out at site at different location
All as per serial item No.1.00 here-in-before but capacity 250 KVA DG set installed at PCDA Southern Command.
All as per serial item No.1.00 here-in-before but capacity 200 KVA DG set installed at Old Telephone Exchange.
All as per serial item No.1.00 here-in-before but capacity 200 KVA DG set installed at SC Signal Centre.
All as per serial item No.1.00 here-in-before but capacity 200 KVA DG set installed at Sewage Treatment Plant.
All as per serial item No.1.00 here-in-before but capacity 160 KVA DG set installed at PCDA Pump House.
All as per serial item No.1.00 here-in-before but capacity 125 KVA DG set installed at SCOM Pump House.
All as per serial item No.1.00 here-in-before but capacity 125 KVA DG set installed at Star Auditorium.
All as per serial item No.1.00 here-in-before but capacity 125 KVA DG set installed at Old telephone exchange.
All as per serial item No.1.00 here-in-before but capacity 110 KVA DG set installed at Old telephone exchange.
All as per serial item No.1.00 here-in-before but capacity 110 KVA DG set installed at Old telephone exchange.
All as per serial item No.1.00 here-in-before but capacity 100 KVA DG set installed at Old telephone exchange.
All as per serial item No.1.00 here-in-before but capacity 82.50 KVA DG set installed at Old telephone exchange.
All as per serial item No.1.00 here-in-before but capacity 70 KVA DG set installed at CE PZ Pump House.
All as per serial item No.1.00 here-in-before but capacity 63 KVA DG set at Old telephone Exchange.
All as per serial item No.1.00 here-in-before but capacity 62.50 KVA DG set installed at MES IB.
All as per serial item No.1.00 here-in-before but capacity 62.50 KVA DG set installed at Victoria Road Pump House.
All as per serial item No.1.00 here-in-before but capacity 62.50 KVA DG set installed at 64 Pump House.
All as per serial item No.1.00 here-in-before but capacity 62.50 KVA DG set installed at IFA HQSC.
All as per serial item No.1.00 here-in-before but capacity 50 KVA DG set installed at Sport Complex (Milka singh) Pump House.
All as per serial item No.1.00 here-in-before but capacity 50 KVA DG set installed at MAP JCOs Race Course Pump House.
All as per serial item No.1.00 here-in-before but capacity 50 KVA DG set installed at RSI Swimming pool.
All as per serial item No.1.00 here-in-before but capacity 50 KVA DG set installed at Parbatali Auditorium.
All as per serial item No.1.00 here-in-before but capacity 50 KVA DG set installed at Victoria Road Pump House.
All as per serial item No.1.00 here-in-before but capacity 50 KVA DG set installed at Ghorpadi No 1 Pump House.
All as per serial item No.1.00 here-in-before but capacity 25 KVA DG set installed at MES colany Pump House.
All as per serial item No. 1.00 here-in-before but capacity 20 KVA DG set installed at Shanti Vihar Pump House.
All as per serial item No.1.00 here-in-before but capacity 15 KVA DG set installed at Children School Pump House.
All as per serial item No.1.00 here-in-before but capacity 15 KVA DG set installed at Nirman Vihar Pump House.
All as per serial item No.1.00 here-in-before but capacity 15 KVA DG set installed at HQ SWAC.
All as per serial item No.1.00 here-in-before but capacity 15 KVA DG set installed at 64 Pump House.
All as per serial item No.1.00 here-in-before but capacity 7.5 KVA DG set installed at HQ SWAC.
Supply only diesel filter element with 'O' ring suitable for 380/250 KVA DG set complete all as specified and as directed
Supply only diesel filter element with 'O' ring suitable for 200/160/150 KVA DG set complete all as specified and as directed
Supply only diesel filter element with 'O' ring suitable for 125 KVA DG set complete all as specified and as directed
Supply only diesel filter element with 'O' ring suitable for 110/100 KVA DG set complete all as specified and as directed.
Supply only diesel filter element with 'O' ring suitable for capacity 82.50/70 KVA DG set complete all as specified and as directed
Supply only diesel filter element with 'O' ring suitable for capacity 63/62.50 KVA DG set including removal of existing unserviceable one complete all as specified and as directed
Supply only diesel filter element with 'O' ring suitable for capacity 50 KVA DG set complete all as specified and as directed
Supply only diesel filter element with 'O' ring suitable for capacity 25/20 KVA DG set complete all as specified and as directed
Supply only diesel filter element with 'O' ring suitable for capacity 15 KVA DG set complete all as specified and as directed
Supply only by pass filter element with 'O' ring suitable for 380 KVA DG set complete all as specified and as directed
Supply only by pass filter element with 'O' ring suitable for 110/100 KVA DG set complete all as specified and as directed
Supply only air filter element suitable for 380/250 KVA DG set complete all as specified and as directed
Supply only air filter element suitable for 200 to 150 KVA DG set complete all as specified and as directed
Supply only air filter element suitable for 125 KVA DG set complete all as specified and as directed
Supply only air filter element suitable for 110/100 KVA DG set complete all as specified and as directed
Supply only air filter element suitable for capacity 82.50/70 KVA DG set complete all as specified and as directed
Supply only air filter element suitable for capacity 63/62.50 KVA DG set complete all as specified and as directed
Supply only air filter element suitable for capacity 50 KVA DG set complete all as specified and as directed
Supply only air filter element suitable for capacity 25/20 KVA DG set complete all as specified and as directed
Supply only air filter element suitable for capacity 15 KVA DG set complete all as specified and as directed
Supply only fan belt complete suitable for 380/250 KVA DG set complete all as specified and as directed Make: Fenner/ Dunlop.
Supply only fan belt complete suitable for 200 to 150 KVA DG set compete all as specified. Make : Fenner/ Dunlop.
Supply only fan belt complete suitable for 125 KVA DG set complete all as specified and as directed Make : Fenner/ Dunlop.
Supply only fan belt complete suitable for 110/100 KVA DG set complete all as specified and as directed Make : Fenner/ Dunlop.
Supply only fan belt complete suitable for capacity 82.50/70 KVA DG set complete all as specified and as directed Make : Fenner/ Dunlop.
Supply only fan belt complete suitable for capacity 63/62.50 KVA DG set complete all as specified and as directed Make : Fenner/ Dunlop.
Supply only fan belt complete suitable for capacity 50 KVA DG set complete all as specified and as directed Make : Fenner/ Dunlop.
Supply only fan belt complete suitable for capacity 25/20 KVA DG set compete all as specified. Make : Fenner/ Dunlop.
Supply only fan belt complete suitable for capacity 15 KVA DG set complete all as specified and as directed Make : Fenner/ Dunlop.
Supply only belt for battery charging alternator complete suitable for 380/250 KVA DG set complete all as specified and as directed Make : Fenner/ Dunlop.
Supply only belt for battery charging alternator complete suitable for 200 to 150 KVA DG set complete all as specified and as directed Make : Fenner/ Dunlop.
Supply only belt for battery charging alternator complete suitable for 125 KVA DG set complete all as specified and as directed Make : Fenner/ Dunlop.
Supply only belt for battery charging alternator complete suitable for 110/100 KVA DG set complete all as specified and as directed Make : Fenner/ Dunlop.
Supply only belt for battery charging alternator complete suitable for capacity 82.50/70 KVA DG set complete all as specified and as directed Make : Fenner/ Dunlop.
Supply only belt for battery charging alternator complete suitable for capacity 63/62.50 KVA DG set complete all as specified and as directed Make : Fenner/ Dunlop.
Supply only belt for battery charging alternator complete suitable for capacity 50 KVA DG set complete all as specified and as directed Make : Fenner/ Dunlop.
Supply only belt for battery charging alternator complete suitable for capacity 25/20 KVA DG set complete all as specified and as directed Make : Fenner/ Dunlop.
Supply only belt for battery charging alternator complete suitable for capacity 15 KVA DG set complete all as specified and as directed Make : Fenner/ Dunlop.
Supply only rubber hose pipe set for water circuit with clamps complete suitable for 380/250 KVA DG set complete all as specified and as directed
Supply only rubber hose pipe set for water circuit with clamps complete suitable for 200/160 KVA DG set complete all as specified and as directed
Supply only rubber hose pipe set for water circuit with clamps complete suitable for 125 KVA DG set complete all as specified and as directed
Supply only rubber hose pipe set for water circuit with clamps complete suitable for 110/100 KVA DG set complete all as specified and as directed
Supply only rubber hose pipe set for water circuit with clamps complete suitable for capacity 82.50/ 70 KVA DG set complete all as specified and as directed
Supply only rubber hose pipe set for water circuit with clamps complete suitable for capacity 63/62.50 KVA DG set complete all as specified and as directed
Supply only rubber hose pipe set for water circuit with clamps complete suitable for capacity 50 KVA DG set complete all as specified and as directed
Supply only rubber hose pipe set for water circuit with clamps complete suitable for capacity 25/20 KVA DG set complete all as specified and as directed
Supply only rubber hose pipe set for water circuit with clamps complete suitable for capacity 15 KVA DG set complete all as specified and as directed
Supply only Engine oil, multi grade premium Genuine oil 15W/ 40 as per manufacturer recommendations in DG sets complete all as specified and as directed Make : Indian oil/ Hindustan Petrolium/ Castrol/ BPCL.
Supply and applying for petrolium Jelly (01 Kg plastic sealed container) complete all as specified and as directed. Make : Indian oil/ Hindustan Petrolium/ Castrol/ BPCL.
Supply and fill for distilled water for topping up in lead acid batteries complete all as specified and as directed.
Supply and fill for electrolyte of suitable specific gravity for lead acid batteries in sealed container complete all as specified and as directed.
Supply and fill for genuine coolant in 5 litres plastic sealed container for topping up in Radiator of DG set located at different locations complete all as specified and as directed.
Material and labour for battery leads of PVC insulated, multistranded, copper conductor of size 50 Sqmm of 1.25 metres long each duly fixed with brass clamps, copper lugs suitable for DG set batteries installed at different locations including removal of existing unserviceable one complete all as specified and as directed.
Material and labour for battery teriminal brass clamps including removal of existing unserviceable one compete all as specified and as directed.
Material and labour for disconnecting all electrical connections from DG set alternator of any capacity from base plate by opening nuts & bolts keeping aside the alternator for inspection and taking out to work shop for rewinding including testing and commissioning complete all as specified and as directed.
Rewinding of alternator field coil with super enamelled copper winding wire of class 'F' insullation as per existing size and gauge including heating, varnishing and testing for capacity 7.50 KVA DG set to 15.00 KVA DG set.
All as per serial item No.88.00 here-in-before but for capacity 20.00 KVA DG set to 25.00 KVA DG set.
All as per serial item No.88.00 here-in-before but for capacity 50.00 KVA DG set to 82.50 KVA DG set.
All as per serial item No.88.00 here-in-before but for capacity 100.00 KVA DG set to 125.00 KVA DG set.
All as per serial item No.88.00 here-in-before but for capacity 150.00 KVA DG set to 200.00 KVA DG set.
All as per serial item No.88.00 here-in-before but for capacity 250 KVA DG set to 380 KVA DG set.
Material and labour for water temperature guage including sensor and cable complete as per sample including removal of existing unserviceable one complete all as specified and as directed.
Material and labour for dismantaling the radiator and taking to work shop for overhauling & cleaning, de-scaling with acid, removal of leakage including soldering and welding, brazing as required and renewal of gaskets, nuts, bolts, mounting pads,hoses,clips, etc and refixing its original position for capacity of 7.50 KVA to 15.00 KVA DG set complete all as specified and as directed
All as per serial item No.95 here-in-befor but for capacity 20.00 KVA to 25.00 KVA DG set
All as per serial item No.95 here-in-befor but for capacity 40.00 KVA to 50.00 KVA DG set
All as per serial item No.95 here-in-befor but for capacity 62.50 KVA to 83.00 KVA DG set
All as per serial item No.95 here-in-befor but for capacity 100.00 KVA DG set to 125.00 KVA DG set
All as per serial item No.95 here-in-befor but for capacity 150.00 KVA to 200.00 KVA DG set
All as per serial item No.95 here-in-befor but for capacity 250.00 KVA to 380.00 KVA DG set
Material and labour for repair and calibration of FIP and injectors from authorised dealer for petty repairs to make the FIP functional as per standard calibration procedure and norms including replacement of minor spares, gasket etc for smooth functioning of FIP and refixing its original position including testing at site for capacity 7.50 KVA to 15.00 KVA DG set complete all as specified and as directed. Note :- A certificate to the effect that the calibration and repairs has been carried out by the authorised dealer shall be submitted by the contractor.
All as per serial item No.102.00 herer-in-before but for 20.00 KVA to 25.00 KVA DG set
All as per serial item No.102.00 herer-in-before but for 40.00 KVA to 50.00 KVA DG set
All as per serial item No.102.00 herer-in-before but for 62.50 KVA to 83.00 KVA DG set
All as per serial item No.102.00 herer-in-before but for 100.00 KVA to 125.00 KVA DG set
All as per serial item No.102.00 herer-in-before but for 150.00 KVA to 200.00 KVA DG set
All as per serial item No.102.00 herer-in-before but for 250.00 KVA to 380.00 KVA DG set
Material and labour for repair/ overhauling of self starting system of DG set including replacement of corbon brushes, bearings, bushes, rewinding of armature and field coil etc and varnishing of capacity 24 volts with necessary connections incluing testing and commissioing complete all as specified and as directed.
Material and labour for repair/ overhauling of self starting system of DG set including replacement of corbon brushes, bearings, bushes, rewinding of armature and field coil etc and varnishing of capacity 12 volts with necessary connections incluing testing and commissioing complete all as specified and as directed.
Material and labour for repairing of battery charging alternator engine mounted with replacement of any of the unserviceable part such as rectifier with voltage regulator, diode plate, corbon brushes of capacity 24 volts including testing and commissioing complete all as specified and as directed.
Material and labour for repairing of battery charging alternator engine mounted with replacement of any of the unserviceable part such as rectifier with voltage regulator, diode plate, corbon brushes of capacity 12 volts including testing and commissioing complete all as specified and as directed.
Material and labour for AVR (automatic voltage regulator) control unit assembly suitable for 7.5 KVA to 82.5 KVA DG set including removal of existing unserviceable one compete all as specified and as directed.
Material and labour for AVR (automatic voltage regulator) control unit assembly suitable for 100 KVA to 380 KVA DG set including removal of exsting unserviceable one compete all as specified and as directed.
Material and labour for fuel steel braided pipe with benjo bolts and washers etc of length 30 cm long including removal of existing unserviceable one compete all as specified and as directed.
Material nad labour for fuel steel braided pipe with benjo bolts and washers etc of length 45 cm long including removal of existing unserviceable one compete all as specified and as directed.
Material and labour for fuel steel braided pipe with benjo bolts and washers etc of length 60 cm long including removal of existing unserviceable one compete all as specified and as directed.
Material and labour for canopy hinges for aquastic doors with suitable bolts and nuts of DG set including removal of existing unserviceable one compete all as specified and as directed.
Material and labour for anti vibration pads with suitable bolts and washers including removal of existing unserviceable one compete all as specified and as directed.
Material and labour for carrying out repairs to AMF panel of 15 KVA to 200 KVA DG set at various installation inclduing study, tracing out circuit, testing, replacing all defective parts, rewinding existing power and control wiring with same cables including testing and commissioning complete all as specified and as directed. (Note: Spares like Volt meter, CT, power contactor required for repair will be measured and paid seperately under relevant items.
Supply only for digital type frequency meter 96 x 96 mm flush/ square pattern compete all as specified. Make: L&T/ AE or equivalent.
Supply only for LED indicator lamps R, Y, B with holder 15 mm screw type compete all as specified. Make: Rishab/ L&T/AE/ Legrand or equivalent
Supply only for CT cast resin type of ratio 400/5 Amps of suitable VA burden compete all as specified. Make: AE/ L&T/ Nutech/ Amol
Supply only for CT cast resin type of ratio 200/5 Amps of suitable VA burden compete all as specified. Make: AE/ L&T/ Nutech/ Amol
Supply and fix for CT cast resin type of ratio 100/5 Amps of suitable VA burden including removal of existing unserviceable one compete all as specified and as directed. Make: AE/ L&T/ Nutech/ Amol
Supply and fix for Power Contactor 415 Volt, 50 Hz AC suitable for DG set control panel/ AMF panel for capacity of 7.50 KVA to 15.00 KVA DG set including removal of existing unserviceable one compete all as specified and as directed. Make: Simens/ L&T/ ABB/ C&S/ Schneider.
All as per serial item No.132 here-in-before but for capacity of 20.00 KVA to 25.00 KVA DG set.
All as per serial item No.132 here-in-before but for capacity of 40.00 KVA to 50.00 KVA DG set.
All as per serial item No.132 here-in-before but for capacity of 62.50 KVA to 83.00 KVA DG set.
All as per serial item No.132 here-in-before but for capacity of 100.00 KVA to 125.00 KVA DG set.
All as per serial item No.132 here-in-before but for capacity of 150.00 KVA to 200.00 KVA DG set .
All as per serial item No.132 here-in-before but for capacity of 250.00 KVA to 380.00 KVA DG set .
Supply and replacement of defective contactor coil in AMF panel, including disconnection of power supply, removal of faulty coil, installation of new contactor coil (compatible rating and specification), testing, commissioning, and restoration of system to normal operation for 415 Volt, 50 Hz AC suitable for DG set control panel/ AMF panel for capacity of 7.50 KVA to 15.00 KVA DG set including removal of existing unserviceable one compete all as specified and as directed. Make: Simens/ L&T/ ABB/ C&S/ Schneider.
All as per serial item No.139 here-in-before but for capacity of 20.00 KVA to 25.00 KVA DG set.
All as per serial item No.139 here-in-before but for capacity of 40.00 KVA to 50.00 KVA DG set.
All as per serial item No.139 here-in-before but for capacity of 62.50 KVA to 83.00 KVA DG set.
All as per serial item No.139 here-in-before but for capacity of 100.00 KVA to 125.00 KVA DG set.
All as per serial item No.139 here-in-before but for capacity of 150.00 KVA to 200.00 KVA DG set .
All as per serial item No.139 here-in-before but for capacity of 250.00 KVA to 380.00 KVA DG set .
Supply and fix for time delay relay suitable for 7.50 KVA to 83.00 KVA DG set including removal of existing unserviceable one compete all as specified and as directed. Make:- Simens/ L&T/ ABB/ C & S
Supply and fix for time delay relay suitable for 100.00 KVA to 380.00 KVA DG set including removal of extg unserviceable one compete all as specified and as directed. Make: Simens/ L&T/ ABB/ C & S.
Material and labour for solinoid switch assembly 24 volts suitable for 100 KVA to 380 KVA DG set including removal of existing unserviceable one compete all as specified and as directed.
Material and labour for solinoid switch assembly 12 volts suitable for 7.5 KVA to 83 KVA DG set including removal of existing unserviceable one compete all as specified and as directed.
Material and labour for self starter assembly 12 volts complete suitable for 7.50 KVA to 83 KVA DG set including removal of existing unserviceable one complete all as specified and as directed. Make: Lucas/ TVS.
Material and labour for self starter assembly 24 volts complete suitable for 100 KVA to 380 KVA DG set including removal of existing unserviceable one complete all as specified and as directed.
Material and labour for DC alternator assembly 24 volts suitable for 100 KVA to 380 KVA DG set including removal of existing unserviceable one compete all as specified and as directed.
Material and labour for DC alternator assembly 12 volts suitable for 7.50 KVA to 83 KVA DG set including removal of existing unserviceable one compete all as specified and as directed.
Material and labour for electronic speed control unit assembly 12 volts suitable for 7.50 KVA to 83 KVA DG set including removal of existing unserviceable one compete all as specified and as directed.
Material and labour for electronic speed control unit assembly 24 volts suitable for 100 KVA to 380 KVA DG set including removal of existing unserviceable one compete all as specified and as directed .
Material and labour fo SMPS (system main power supply) type control unit assembly suitable for 12 volts battery charger for including removal of extg unserviceable one compete all as specified .
Material and labour for SMPS (system main power supply) type control unit assembly suitable for 24 volts battery charger for including removal of existing unserviceable one compete all as specified and as directed .
Supply and fix for single phase preventer suitable for operation on 415 Volts 50 Hz AC supply including removal of existing unserviceable one compete all as specified and as directed. Make : L&T/ Minilec.
Supply and fix for three phase preventer suitable for operation on 415 Volts 50 Hz AC supply including removal of existing unserviceable one compete all as specified and as directed. Make : L&T/ Minilec.
Supply and fix for battery low maintenance lead acid of capacity 12 volts 180 AH with initial charging including removal of existing unserviceable one and hand over to store yard compete all as specified and as directed. Make: Exide/ AMCO/ Amaron.
Supply and fix for battery low maintenance lead acid of capacity 12 volts 150 AH with initial charging including removal of existing unserviceable one and hand over to store yard compete all as specified and as directed. Make: Exide/ AMCO/ Amaron.
Supply and fix for battery low maintenance lead acid of capacity 12 volts 135 AH with initial charging including removal of exsting unserviceable one and hand over to store yard compete all as specified and as directed. Make: Exide/ AMCO/ Amaron.
Supply and fix for battery low maintenance lead acid of capacity 12 volts 100 AH with initial charging including removal of extg unserviceable one and hand over to store yard compete all as specified and as directed by Engr-in charge. Make:- Exide/ AMCO/ Amaron
Material and labour for control wiring of the DG set upto 125 KVA complete with provision of additional auto cables heavy duty suitable for generator set applications including removal of existing unserviceable one compete all as specified and as directed.
Material and labour for control wiring of the DG set above 125 KVA to 380 KVA complete with provision of additional auto cables heavy duty suitable for generator set applications including removal of existing unserviceable one compete all as specified and as directed.
Material nad labour for top overhauling only of DG set of Kirloskar/ Cummins/ Crompton Greaves make including replacement of gaskets and Oil sump packing set etc, testing on full load upto entire satisfaction of Engineer-in-Charge for capacity of 7.50 KVA to 15.00 KVA DG set complete all specified and as directed.
All as per serial item No.166 here-in-before but capacity of 20.00 KVA to 25.00 KVA DG set
All as per serial item No.166 here-in-before but capacity of 40.00 KVA to 50.00 KVA DG set
All as per serial item No.166 here-in-before but capacity of 62.50 KVA to 83.00 KVA DG set
All as per serial item No.166 here-in-before but capacity of 100.00 KVA to 125.00 KVA DG set
All as per serial item No.166 here-in-before but capacity of 150.00 KVA to 200.00 KVA DG set
All as per serial item No.166 here-in-before but capacity of 250.00 KVA to 380.00 KVA DG set
Supply and fix for solenoid valve suitable for capacity of 7.50 KVA to 15.00 KVA DG set DG sets for smooth function of DG sets including removal of existing unserviceable one complete all specified and as directed .
All as per serial item No.173 here-in-before but capacity of 20.00 KVA to 25.00 KVA DG set.
All as per serial item No.173 here-in-before but capacity of 40.00 KVA to 50.00 KVA DG set.
All as per serial item No.173 here-in-before but capacity of 62.50 KVA to 83.00 KVA DG set.
All as per serial item No.174 here-in-before but capacity of 100.00 KVA to 125.00 KVA DG set.
All as per serial item No.173 here-in-before but capacity of 150.00 KVA to 200.00 KVA DG set .
All as per serial item No.173 here-in-before but capacity of 250.00 KVA to 380.00 KVA DG set .
Material and labour for engine complete overhauling of DG set capacity 125 KVA to capacity 200 KVA of Kirloskar/ Crompton Greaves makes by opening the top cover complete including dismatling the engine head, cylinder liner and piston assembly, crank shaft assembly, radiator fan belt and radiator fan, gear assembly complete removing of engine side for repair/ replacement of parts i.e gasket, washer, 'O' ring all types etc including grinding polishing of crank shaft , head repairing and overhauling valve seat cutting and replacing, valve tapping, head assemble and testing of DG set after necessary repair with and authorised dealer fix at site reassembling of DG set and testing on full load upto entire satisfaction of Engineer in Charge complete all as directed (Note : Spare parts will be measured and paid seperately under relevent items)
Supply only piston assembly
Supply only piston ring set
Supply only full engine gasket
Supply only main bearing set
Supply only main cylinder liner
Supply only main cylinder head copper sleeves
Supply only lock nut
Supply only big end bearing
Supply only timing belt
Supply only benjo bolt
Supply only timing belt tension adjuster
Supply only inlet valve
Supply only exhaust valve
Supply only head gasket
Supply only oil pump assembly
Supply only thrust washer
Supply only crank case gasket
Supply only head nozzle plug set
Material and labour for engine complete overhauling of DG set capacity 62.50 KVA to capacity 110 KVA of Kirloskar/ Crompton Greaves makes by opening the top cover complete including dismatling the engine head, cylinder liner and piston assembly, crank shaft assembly, radiator fan belt and radiator fan, gear assembly complete removing of engine side for repair/ replacement of parts i.e gasket, washer, 'O' ring all types etc including grinding polishing of crank shaft , head repairing and overhauling valve seat cutting and replacing, valve tapping, head assemble and testing of DG set after necessary repair with and authorised dealer fix at site reassembling of DG set and testing on full load upto entire satisfaction of Engineer in Charge complete all as directed (Note : Spare parts will be measured and paid seperately under relevent items)
Supply only piston assembly
Supply only piston ring set
Supply only full engine gasket
Supply only main bearing set
Supply only main cylinder liner
Supply only main cylinder head copper sleeves
Supply only lock nut
Supply only big end bearing
Supply only timing belt
Supply only benjo bolt
Supply only timing belt tension adjuster
Supply only inlet valve
Supply only exhaust valve
Supply only head gasket
Supply only oil pump assembly
Supply only thrust washer
Supply only crank case gasket
Supply only head nozzle plug set
Supply and fix for pressure gauge 0 to 7 Kg/ sqcm along with sensor and cables for DG set including removal of existing unserviceable one complete all as specified and as directed.
Supply and fix microprocessor based AMF controller suitable for DG sets operation of any capacity and showing the various parameters such as volt, ampere, frequency, RPM etc complete as per manufacturer of DG set with site requirment including removal of existing unserviceable one complete all specified and as directed.
Material and labour for chart/ diagram/ name plates/ details of DG sets made out of bakeite hylem sheet, ISI marked, 3 mm thick , cutting to shape/ size including fixing of adhesive transparent filament of red/ blue colour including cutting of filament of letters/ figures/ diagrams/ details of suitable size/ type including fixing to the wall by wooden screws and PVC hold fast etc complete all as specified and as directed. Note : Matter/ figure/ chart/ diagrams/ letter shall be give by the Engineer- in- Charge.
Supply, connecting and testing for MCCB in existing DG set panel of capacity 3 pole 63 Amps with thermal magnetic release breaking capacity 16 KA, Ics=100% Icu , suitable for 415 volts, 50 Hz, with extended terminals type, inter locked to prevent opening when the Switch is in ON position, connecting and testing complete including removal of existing unserviceable complete all as specified and as directed. Make: L&T/ ABB/ Siemens/ Schneider as approved.
All as per serial item No.221.00 but capacity of 3 pole 100 Amps with thermal magnetic release breaking capacity 25 KA, Ics=100% Icu.
All as per serial item No.221 but capacity of 3 pole 125 Amps with thermal magnetic release breaking capacity 25 KA, Ics=100% Icu.
All as per serial item No.221 but capacity of 3 pole 160 Amps with thermal magnetic release breaking capacity 25 KA, Ics=100% Icu.
All as per serial item No.221 but capacity of 3 pole 200 Amps with thermal magnetic release breaking capacity 25 KA, Ics=100% Icu.
All as per serial item No.221 but capacity of 3 pole 250 Amps with thermal magnetic release breaking capacity 36 KA, Ics=100% Icu.
All as per serial item No.221 but capacity of 3 pole 400 Amps with thermal magnetic release breaking capacity 36 KA, Ics=100% Icu.
Supply, connecting and testing open execution on load change over in existing DG set panel of capacity of 4 pole 63 Amps, suitable for 415 volts, 50 Hz, with extended terminals type, interlocked to prevent opening when the switch is in ON position, connecting and testing complete including removal of existing unserviceable complete all as specified and as directed. Make: ABB/ Siemens/ Schneider/ Legrand as approved.
All as per serial item No.228 but capacity of 4 pole 100 Amps.
All as per serial item No.228 but capacity of 4 pole 125 Amps.
All as per serial item No.228 but capacity of 4 pole 160 Amps.
All as per serial item No.228 but capacity of 4 pole 200 Amps.
All as per serial item No.228 but capacity of 4 pole 400 Amps.
Supply & Installation of Maintenance Free Earthing System consisting of a Copper bonded steel rod shall have 17.2 mm dia. & min. 10 feet length as per UL 467. The material shall have low carbon, high tensile steel molecularly bonded with 99.99% pure electrolytic grade copper thickness of minimum 250 microns with an exothermically welded Cu Busbar of (50X6X200mm) both tested by CPRI at 25 kA Fault Current carrying capacity. Copper Bonded Rod shall be UL listed. The manufacturer shall be RDSO approved to ensure the manufacturing capacity & capability along with the quality of the earthing rod. Along with a sealed bag of minimum 30 kg (10 kg Bag x 3) RoHS tested Earth Enhancement Compound tested by NABL accredited lab in compliance to IEC 62561-7 with a resistivity of not more than 1.0 ohm-m. It shall be a carbon based material and shall be free from bentonite and other hazardous substances. It shall be a permanent, non-corrosive material and will not leach any chemicals into the ground. It shall retain moisture even in high soil resistivity areas. It shall lower an earth resistance value and shall offer a constant desirable performance. Including an Earth Pit cover shall be made of Poly plastic tested at 7.5 ton load for closing of earth.
S&F Earth continuity Copper clad steel conductor or main earthing lead fixed to wall on batten or reccess or chases or burried in ground or drawn in conduit/pipe or fixed to pole or any other indicated situation for loop earthing etc as required 8 mm dia after taking down the old one any type.
Supply , install,test in repair cubical outdoor type, weather type, weather proof IP-54 AMF Control panel fabricated out of 3.0 mm thick CRCA MS sheet for outer panel and 1.6 mm MS sheet for internal compartments, powder coated incorporating the following items including control wiring etc Mechanically and electrically interlocked : (a) Power Contactor - 04 Pole, 125 Amp, AC-1 Duty, Coil voltage, 240 V AC, 2NO+2NC AUX Contacts = 02 Nos. (b1) MCCB 4 pole 100 amps with themal magnetic settings-01 No (b2) MCCB 4 pole 63 amps with themal magnetic settings-01 No (b3) MCCB 4 pole 32 amps with themal magnetic settings-04 No © Electronic KWH Meter, 5A-60A, 3x240V AC, 3 Phase 4 wire 50 Hz = 01 No. (96 x 96 mm flush mounting) (d) Current Transformer, CTR-150/5A, ACC-CL-1, 5A = 03 Nos (e) Current Transformer, CTR-150/5A, ACC-CL-5P10, 5VA = 01 No. (f) Electronic Earth Fault Relay, 5 A, 240V AC, 2 C/O Contacts, Surface Mounting with Test & Reset PB = 01 No. (g) Microprocessor Based (Controller Unit) 415 V AC, 3 Phase, 4 Wire, 50 Hz, Sensing for mains & DG (ALT.) Current Input 5 A, Protection U/V, O/V, O/F, for mains and DG (OC for DG only) Battery Voltage Low & Operating Voltage 8-32 V DC, DG Metering (A+V+Hz+PF+KWH) = 01 No. (h) Electronic Hooter 24 V DC, 96 x 96 Flush Mounting = 01 No. (j) Aux relay 12 V DC with LED, Free Wheeling Diode, 3/4 change over contacts at 10 A rating DIN Rail mounting and plugin base module type = 02 Nos. (k) Aux relay 12 V DC with LED, Free Wheeling Diode, 4 change over contacts at 5 A rating DIN Rail mounting and plugin base module type = 04 Nos. (l) Aux relay 12 V DC with LED, Free Wheeling Diode, 2 change over contacts at 5 A rating DIN Rail mounting and plugin base module type = 03 Nos. (m) AUX contactor, 240 V AC with suitable NO + NC Contacts = 01 No. (n) LED Indicating lamp 240 V AC = 02 Nos. (o) LED Indicating lamp 12 V DC = 02 Nos. (p) Push Button with elements = 07 Nos. (q) Stayput type Push Button with elements = 01 No. (mounted on accoustic enclosure) Note: (a) Suitable PCC plinth for mounting the AMF panel not less than 500 mm height from the ground with adequate space not less than 600 mm in front of the panel for smooth operation shall be provided by the contractor for fixing the panel (b) Adequate space shall be provided for cable entry and exit. Add Necessary PCC plinth for mounting the DG set as per manufacture design. (c) The panel drawing to be approved by accepting officer before to place order.
Supply and fix on replacement water lifting and booster pump 1.5 Hp single phase suction with necessary factory fabricated auxillary tank and discharge,( 25 mm x 25 mm ) total head upto 10-42 mtr, capcity upto 75 - 6 LPM monoblock, multiple noryl/brass impellar pump type suitable for 230 volts with all necessary fittings including copper cable upto 5mtr.Including removol of old unsv one complete all as specified and as directed Make kirloskar CPBS 84424H/V,KSB KSB KHM 406,Texmo ADBS 44 HS / 60L
S & F in repairs pressure control switch having ,IP 65 rating,dry running protection with automatic reset NoiselessDesigned for high start/stop per hour Built in thermal protection Make:Btalli,V guard,CRI
Supply and fix on replacement water lifting pump 0.25Hp single phase suction and discharge,( 19 mm x 19 mm ) total head upto 15 mtr, capcity upto 600-1600 LPH monoblock pump type suitable for 230 volts with all necessary fittings including copper cable upto 5mtr.Including removol of old unsv one complete all as specified and as directed.Make kirloskar Tiny 63,Crompton ,KSB
Supply and fix on replacement on-line pressure boosting pump, outdoor, weather proof electrically operated 240 volts, 50 Hz fixed to 15/20 mm dia of capacity Head 10 mtrs Flow rate-35 LPM power input 0.1 KW with three opearting position OFF/AUTO/MANNUL and componants of ceramic radial Ball Bearing, copper stator winding, EPDM rubber gasket, Aluminium oxide Shaft, carbon trust Ball Bearing, composit PP30% GF impeller including the integrated flow switch starts or stops the pump when a tapping point is turned on or off including, electrical connections, relaying of pipe lines, GI fittings, and removal of old unsv one complete all as specified and as directed. Make Wilo cat no.PB88,Kirloskar,KSB
Supply and fix on replacement on-line pressure boosting pump, outdoor, weather proof electrically operated 240 volts, 50 Hz fixed to 15/20 mm dia of capacity Head 16 mtrs Flow rate-50 LPM power input 0.2 KW with three opearting position OFF/AUTO/MANNUL and componants of ceramic radial Ball Bearing, copper stator winding, EPDM rubber gasket, Aluminium oxide Shaft, carbon trust Ball Bearing, composit PP30% GF impeller including the integrated flow switch starts or stops the pump when a tapping point is turned on or off including, electrical connections relaying of pipe lines, GI fittings, GI fittings and removal of old unsv one complete all as specified and as directed. Make Wilo cat no. PB 200,Kirloskar,KSB
Note : 1. Performance security:- Refer Condition 22 of Special Conditions. 2. Quoted Contract Sum shall be arrived at after deducting the amount of Credit Schedule (refer Schedule of Credit in pdf form for quantity, rate and amount etc.) for old unserviceable materials retrieved from site.
ANAND ENTERPRISES (BID ID -3400355)
TIMES HYDRO-ELECTRIC COMPANY (BID ID -3412126)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .