| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAccepted-AOC SHOP NO 11 BLOCK C PARASHAR COMPLEX RAJGARH ROAD SOLAN 173212 | SOLAN | HIMACHAL PRADESH | 173212 | L1 | Accepted-AOC L1 | |
| 2 | L2₹9.5 L+₹11,544 (1.23%)Rejected-Finance | L2 | Rejected-Finance Bidder found and 2nd lowest bidder in the bid offer submitted by the bidder |
Tender Value
₹11.5 L
EMD Value
₹23,000
Closing Date
27 Apr 2026, 5:00 pmClosed
EE
Electrical Division No.II, HPPWD, U.S. Club, Shimla-01.
Providing special repair of MRI and USG chambers Dr. room corridor wairting area and toilets in old causality Block B at IGMC Shimla. Providing VRV system and inline duct fan therein.
2026_PWD_131872_10
ED.II.CB.TA.NIT.25.26.3934 dt. 17.03.26
Open Tender
Electrical Works
Percentage
90 days
Shimla
Please refer to tender documents. Eligibility criteria is mentioned at page No. 6-7, 9-10 of GCC. Documents mentioned in eligibility criteria must be uploaded to qualify the bid.
7 documents required · 7 mandatory
₹500
₹23,000
3 Jun 2026
20 Apr 2026
28 Apr 2026
20 Apr 2026
27 Apr 2026
20 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Supply, Installation, Testing & Commissioning of factory fitted mircoprocessor based self diagnostic auto check VRV/VRF system outdoor unit equiped with PCBs, accumulator, oil seperator, burshless DC inverter fan motor, OEM self manufactured hermetic sealed multi valve scroll type compressors. Compressor should be based on low pressure shell technology for longer life with integrated IPM & PWM to ensure effective operation even at low/partial load conditions for better efficiencies. Compressor shall be fixed in metallic chamber for lower noise with enhanced fire saftey protection. Outdoor unit shall be equiped with highly efficient induction type heater using eliminated wasted heat. VRT/VET system shall be based on advanced & automatically modulation evaporating refrigerant temperature between 0°C to 11°C for instant cooling and better energy effiency as per user's demand. Outdoor units shall be essentially equiped with saftey devices like fuse, noise filter PCB, low pressure switch, high pressure switch, pulse based LEV for optimized refrigerant flow control, isolating valve, protective corrosion resistant polyster coating on panels, hydrophilic coating on Aluminium fins, protective polyeurethane coating on PCB, OEM provided Inbuilt automatic reverse phase detector & sequencer/corrector to avoid any kind of failure due to phase sequence reversal which makes system relaible and redundant. Heat exchanger must be essentially equiped with internally grovved copper tubes for better heat exchange performance and operate in extreme conditions i.e. even at ambient temparature of 52°C or more. Outdoor units shall be pre-charged with R401A gas, pump down fucntion and shall also be equipped with charging valve/ports for additional charge of refrigerant as per site requirement. All outdoor unit shall be able to perform in duty cycle mode to optimize wear and tear of system when more than one outdoor unit is connected to a circuit. Outdoor units must also be equiped with four way valve for necessary provision of heating during winters. All outdoor shall have approximately following as per OEM standards rated capacities at ARI conditions and, with the criteria of delivering 95% capacity at 43 °C being most likey temperature to occur during summers. (All Unit shall confirm the detailed specification of tender document and providing power/ control cabling/earthing of indoor unit complete with supplying of all material in all respect as per specifications and any other items required to make the system complete as required)The manufacturer of ODU and compressor shall be same. i.e. the make of compressor shall be identicle of the ODU. Make : Daikin , O General, Trane, Mitsubishi or any other approved by Engineer-in-Charge. | - | - | - | - |
| 1.01 | Outdoor Unit -8 HP | - | Each | - | - |
| - | Indoor Units:Round Flow Cassette Type | - | - | - | - |
| 2.01 | Supply, Installation, Testing and Commissioning of VRV/VRF indoor units with factory fitted electronic expansion valve, multi speed fan motors, dynamically balanced blowers, synthetic washable plasma media filter with hydrophobic coating on cooling coil. Electronic components like PCBs must be essentially enclosed in a metal box compartment being integrated part of indoor unit to ensure enhanced fire protection with auto by pass technology allowing uninterupted operation of indoor units connected to a circuit in event of break down in any indoor connected to same circuit. All indoor units shall have individual fan speed and temperature control mechanism to be operated from corded/cordless remote. In addition to all indoor units can also be operated from central remote control. (All Unit shall confirm the detailed specification of tender document and providing power/ control cabling/earthing of indoor unit complete with supplying of all material in all respect as per specifications and any other items required to make the system complete as required) | - | - | - | - |
| 2.02 | Cassette Type Indoor Unit - 1.6 TR | - | Each | - | - |
| - | Supply and installation of Refrigerant Piping Y-Joints / Headers, suitable for both liquid and gas lines, for connecting the outdoor units to the indoor units in VRV/VRF system, complete in one set as required including all necessary fittings and accessories. | - | Each | - | - |
| - | Supply, Installation, Testing and Commissioning of Corded Remote Controller suitable for above indoor units, complete with all accessories, wiring, and connection to IDU, as required — complete in all respects. | - | Each | - | - |
| - | Supply, Installation, Testing and Commissioning of PVC Drain Water Piping, minimum pressure rating 15 kg/cm², complete with all fittings such as elbows, tees, reducers, sockets, hangers/supports, jointing accessories and any other items required to make the system complete. The drain piping shall be insulated with 9 mm thick Class-O XLPE insulation, complete as required. | - | - | - | - |
| 5.01 | 25 mm dia (with 9 mm Class-O XLPE insulation) | - | Meter | - | - |
| - | Supply, Installation, Testing and Commissioning of Copper Refrigerant Piping for VRV / VRF System, including all fittings, supports, brazing/jointing, insulation with Class-O XLPE, gas charging & commissioning, complete with all accessories and any other item required to make the system fully operational all as per specifications and drawings. Pipes shall be of soft-drawn copper, insulated with 13 mm thick Class-O XLPE insulation, and of sizes as indicated below: Complete in all respects as required. | - | - | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.36 MB
BOQ_198800.xls
BOQ • 0.36 MB
GCC.pdf
Tender Documents • 5.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .