| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹4.4 L+₹87,690 (25.2%)Rejected-Finance | L2 | Rejected-Finance Emd Rejected |
Tender Value
₹4.7 L
EMD Value
₹9,468
Closing Date
28 Sept 2023, 10:00 amClosed
Executive Engineer
Office of the Executive Engineer,EE(Elec) Division,SZ
Improvement and amp development of Electrical Installation and amp fans at various Mpl.schools in ward no 160S and 161S under south zone
2023_MCD_168340_1
MCD/TR/5939/2023_6_1_1/1
Open Tender
Electrical Works
Item Rate
30 days
Devli
6 documents required · 6 mandatory
₹590
₹9,468
2 Apr 2024
21 Sept 2023
28 Sept 2023
21 Sept 2023
28 Sept 2023
21 Sept 2023
Amount
OD7514/2023-2024:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group C
OD7515/2023-2024:Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
OD7521/2023-2024:Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
OD7652/2023-2024:Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. (a) 150 mm X 75 mm X 60 mm deep
OD7653/2023-2024:Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. (b)200 mm X 250 mm X 60 mm deep
OD7654/2023-2024:Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 250 mm X 300 mm X 60 mm deep
OD7656/2023-2024:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surfac/recessed steel/ PVC conduit as required. (a) 3 x 2.5 sq. mm
OD7658/2023-2024:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surfac/recessed steel/ PVC conduit as required.3 x 4 sq. mm
OD7659/2023-2024:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surfac/recessed steel/ PVC conduit as required. 3 x 6 sq. mm
OD7864/2023-2024:Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 15/16 A switch
OD7870/2023-2024:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 8 way, Double door
OD7871/2023-2024:Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 6 pin 15/16 A socket outlet
122.1.3:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm
122.1.44:Supply of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
122.2.29:SITC of 100W LED Flood Light luminiare fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =100 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
122.2.39:S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
122.2.156.(c):P&F following sizes of PVC insulated & PVC sheathed copper conductor 3 core submersible cable confirming to IS.694/1990 etc. as reqd. 3x 6 sq.mm
OD7879/2023-2024:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surfac/recessed steel/ PVC conduit as required.6 x 2.5 sq. mm
OD7880/2023-2024:Supply and fixing of 3 mm thick phenolic laminated sheet
OD7881/2023-2024:Repair/Rewinding of Ceiling Fan including replacement of parts like bush/bearing condenser, Fan hook etc to make the fan functional as required.
OD7882/2023-2024:Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
OD7884/2023-2024:"Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required."
OD7885/2023-2024:Supply of 1200 mm sweep 50 watt, Energy saver ISI Marked BEE 5 Star rating AC Celing fan suitable for 230 V, 50 heartz AC supply without regulator with blades, downrod etc. complete asquired.
OD7886/2023-2024:Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125 A,36KA,FPMCCB
OD7887/2023-2024:Supplying and fixing following rating ,double pole,240 volt,isolator in the existing MCB DB complete with connections,testing and commissioning etc. as required. (a) 40 amps
OD7888/2023-2024:Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required3 pin 5/6 A socket outlet
OD7889/2023-2024:Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. (a) 5/6 amps switch
OD7890/2023-2024:"Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20mm"
OD7891/2023-2024:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamp with 1 mm thick saddle).
OD8219/2023-2024:Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required. Group C
Shivam Enterprises
Bidder Name
M/s Samsh Qadri
Shivam Enterprises
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .