Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.2 LAccepted-AOC 6 KRIPANATH DUTTA ROAD KOLKATA 700 002 | KOLKATA | KOLKATA | WEST BENGAL | 700002 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹12.9 L+₹61,139.34 (4.99%)Rejected-Finance 344 1 SB GORAI ROAD HILL VIEW PARK NORTH ASANSOL | ASANSOL | WEST BENGAL | L2 | Rejected-Finance NOT L1 BIDDER | |
| 3 | L3₹13.0 L+₹78,897.16 (6.44%)Rejected-Finance PATRA MARKET KRISHANAGAR NADIA | KRISHANAGAR | NADIA | L3 | Rejected-Finance NOT L1 BIDDER |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
9 Sept 2024, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer,Asansol Mechanica Division
Office of the Executive Engineer Asansol Mechanical Division,Public Health Engineering Directorate,SEN-RALEIGH ROAD,PASCHIM BARDHAMAN 713 305
Repairing of ATS along with other electrical and mechanical ancillaries at Kalyaneswari Head Works, under RCFA-I Water Supply Scheme, under Asansol Mechanical Division.
2024_PHED_736315_1
WBPHED/EE/AMD/NIeT-20of 2024-2025
Open Tender
Miscellaneous Works
Item Wise
30 days
klayaneswari
Please refer Tender documents.
3 documents required · 3 mandatory
₹30,000
26 Nov 2024
20 Aug 2024
11 Sept 2024
20 Aug 2024
9 Sept 2024
20 Aug 2024
Amount
Supply, delivery at site and fitting fixing of Ammeter & Voltmeter at the following Feeders complete with withdrawal of the old faulty.
Digital Ammeter conzerv DM 1110, (Make-Approved Make)
Ammeter (0-150A) Make : AE for Motor Feeder No. 1
Analog Voltmeter (0-500V), Make: AE for Incomer Feeder
Deputing of skilled Technicians and personnel to inspect the ATS in (225KW) spare at site Kalyaneswari, dismantling, Megar Report, Tests conducted as per direction of the EIC.
Carrying of the ATS kalyaneswari to Kolkata workshop and back to kalyaneswari after repairing including loading and unloading charges.
Repairing of the spare ATS 225KW at works includes opening the coils from ATS and dismantling the same, supply and fixing of new Copper with double Nomax, insulation, supply of varnish (ELMO-50), supply & fixing of Nomaxinterlayer, reassembling of the coil after winding & fixing the top core along with necessary connection and Testing of the Transformer complete.
Repairing the Back Wash Pump after withdrawal of its casing, includes decoupling checking of the bearing along with other spares that includes neck ring and shaft sleeve with gland water thrower and rubber bush as per direction, work includes replacement of the rubber bush as per sample along with Nuts Bolts and Washers with Gear Oil 1 Ltr replacement also welding the base plate, levelling and alignment after fitting fixing and servicing, testing & commissioning to the entire satisfaction of the EIC.
Supply, delivery at site 55KW, 3 Phase Squirrel Cage TEFC, foot mounted, IP 55, IE2, S1 Duty, Class-F Insulation, Temp Rise Class-B, Induction Motor Standard IS : 12615/IS/IEC 60034, Ambient 50 Deg C, 50 Hz, +/- 5% frequency, 415V +/- 10%, 4 Pole, 1500 RPM, ND 250MX Frame (Make-Approved Make)
Supply of Tyre Coupling (Unique make) for the above Pump Motor set (55KW) TC 101015-2913DE
Rubber Tyre (Unique make) 2913 DE for Pump No. 1
Installation of the newly supplied motor, withdrawal of the faulty motor from its Frame, decoupling, cables-de-termination, fixing of the new Motor, Nuts & Bolts fixing, coupling after levelling & alignment, termination, replace of the relays and Testing & Commissioning to the entire satisfaction of the EIC.
Testing of all relay viz earth fault, over load, buchholz and checking of master trip, trip circuit supervision,CT,PT, spring charging system, closing/trip coil, breaker of HT and LT panel etc. Including calibration of Ammeter, Voltmeter, Power Factor Meter etc. by agency approved by irectorate of Electricity/WBSEDCL/Any power generating unit and submission of the Test Report to Department (4 Panel 33K VCB, LT Panel, 1200A ACB-5Ns., SFU-30A:7 Nos., SFU 400A: 1 No., SFU 250A : 2 Nos., SFU 200A : 2 Nos., SFU 125A : 4 Nos., Transformer 1000KVA,33/0.433KV : 3 Nos., In LT Panel - CDG-31 : 3 Nos. (2O/C, 1 E/F each), In HT Panel-MICOM P127 (Incomer - 3 O/C, 1 E/F1 O/V), Each Outoging (3 O/C (I>,I>>),1E/F(Ie>,Ie>>)}.
Following Testing of Transformer oil should be done:-i)Inter facial tension by Ring Method (IS 6104-1971)(ii)Flash point by pensky materns method, IS 1448 (P21)-1992(iii)Neutralization value (acidity) by chemical test, IS 1448 (P2)-1967.(iv)Di-electric strength (BDV) by electrode type method, IS 6972-1992.v)Specific resistance (Resistivity) by three terminal cell method IS 1603-1971(vi)Moisture (water) content by Karal Fischer titration method, IS 13567-92 (vii)Di-electric dissipation (tanD) by three terminal cell method, IS 6262-1971(viii)Sludge content by chemical test method IS 1866 Annex-A.(ix)Dissolve gas analysis (DAG) Gas chromatograph method, IS 10593 & 9433 (Transformer oil testing should be done from authorized laboratory and submission of Test Report to department as per direction and to the entire saitsfaction of the EIC.
Supply, delivery and withdraw of burnt out Fuse from ATS of High Lift Pump and installation of the newly supplied L&T make DIN Type FN 630A Fuse Link Cat No. SF 94437.
Add. GST@18%
Add. Cess@1%
EASTERN INDIA SALES AND SERVICE (BID ID -5524183)
Tarun Kumar Bhattacharya (BID ID -5540931)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .