Proposed construction of RUB at LC no 286 at Km 474/000-474/100 in between UNK-BDKA section
05UBL2026-27-01
05UBL2026-27-01
Open
6 Months
Unknown (Unspecified Location)
₹0
₹2.3 L
3 Jul 2026
3 Jul 2026
20 Jul 2026
A-Signal Chapter-01
A-Signal Chapter-02
A-Signal Chapter-04
A-Signal Chapter-05
A- Signal Chapter-06
A-Signal Chapter-07
A-Signal Chapter-08
A-Signal Chapter-12
A-Signal Chapter-15
A-Signal Chapter-18
A-Signal Chapter-22
A-Telecom Chapter-02
A-Telecom Chapter-06
A-Telecom Chapter-15
A-Telecom Chapter-20
A-Telecom Chapter-21
A-Telecom Chapter-22
B-Signal Chapter Non SOR
B-Telecom Chapter Non SOR
Item Breakup - A-Signal Chapter-22
5000.00 road as per the instructions of Railway representative at site. The work also includes loading and unloading of the materials. Transportation up to 100 Kms. Total 120000.00
Item Breakup - A-Signal Chapter-05
1.00 386787.00 operated Lifting Barrier set with Hand generator with operating voltage of 110V AC/DC. Each set consisting of 2 Nos. of Lifting Barrier Pedestals, each with 8 contact circuit controllers with top roller type Limit Switches (as per Design given in specification & approved by RDSO) Hand Crank, Electric Motor 110V AC/DC. 2 GI sheet Booms of 32 ft length (4 section of 8 Ft long each) with new octagonal shape as per RDSO drg. No. RDSO/S 11600. - Version 2.0 or latest, without fringes, with 2 stop boards in Trilingual i.e Hindi, English & Regional language and MS Counter weights and 02 nos. of boom supports with Motorized / Solenoid boom locking along with 01 no. of hand Generator cum Control panel to operate 2 barriers of a set with 1 selector switch, 3 buttons and 5 indication lamps, contacts, MCB's and relays
wiring, commissioning of electrical/mechanical lifting barrier as per requirement.
2.00 type of required ward Nos. with keys, as per specification/ No. IRS S.21/2001 Rev.1.0 or latest.
1.00 crank handle or on suitable fixtures at station/apparatus case, provision of economiser push switch with locking facility, wiring with wire PVC 16/0.2mm copper, provision of teakwood terminal box covered with decolum along with locking facility and painting. (Supply of electric key transmitter and crank handles is not covered in this item). [wire PVC 16/0.2mm copper, wire wound resistance, decolum covered terminal box with locking facility by using 25mm thick teakwood, bolts and nuts, paints, push switches, padlocks and other miscellaneous materials required for this work shall be supplied by the contractor].
1.00 consist of 2 nos Horn Speakers, 2 Nos of Hooters and Amplifier with Trilingual i.e Hindi, English & Regional language voice announcement HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
1.00 Gate Warning equipment for each level crossing gate, one on each road warning signal, amplifier in the apparatus case with wire PVC 3/0.75mm and 16/0.2mm copper, and painting. (Electronic Gate Warning Equipment and amplifier will be supplied by Railways). [All wiring, fixing and painting materials shall be supplied by Contractor].
1.00 Sliding Barrier Boom Set (one set will consist of two sliding barrier booms, one for either side of track) this include carry out civil masonary work at site like digging of pits for foundations, casting of RCC foundation and fixing of foundation bolts (12 nos. in each site of size 18"x18"x36"). This also include loading, unloading and leading of all the material to site of work from the store of Concerned SSE/Sig/ Incharge (One set at each location) This include complete sliding gate in working order as per instruction of Railway Engineer at site and painting of sliding boom type barrier of LC gate with metallic paint, similar to Asian paint or better .All materials except sliding boom gate & 'E' type lock with key to be supplied by the contractor. (Gate = LC Gate)
2.00 gates like SM slide instruments, illuminated diagram board, block counter, termination box, telephones, emergency key box, dismantling of ground lever frame along with all connected lever locks, 'E' type locks, HP locks, breaking and removal of concrete foundation, lock rods with rod roller trestles, complete assembly, cranks, compensators, 'A' type concrete foundation on the rod run, transmission wires single wire/double wire accounting and stocking them neatly at a place as instructed by Railway representative at site. After releasing any holes on the walls/ floor are to be filled with cement mortar and plastered. Total 530498.00
Item Breakup - A-Signal Chapter-12
50.00 secondary cells 2V-80AH capacity as per IRS: S 88/2004 Version 1.0 or latest.
of capacity. Total 224600.00
Item Breakup - A-Telecom Chapter-06
2000.00 soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. (Laying of cables is not included in this item). HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
2000.00 0.3m width throughout, with earth after laying of cables, and consolidating the trench by ramming and levelling
100.00 less than 30CMs in rocky terrain, concreting the trench with 150mm thick concrete with 1 cement, 2 sand, 4 grade stone 20mm nominal size. (All the materials are to be supplied by the contractor).
100.00 pipe/DWC/HDPE pipe in which cable is already laid to a size of 300x300mm with 1:3:6 mortar. (All the materials required for the work should be supplied by the contractor).
of Metre Signaling/Power/Telecommunication cables as per cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc. (Supply of cables is not included in this item).
24.00 thick as per latest specification.
24.00 for cable laying with offset at both ends and with couplings over Girder bridges by fixing on suitable MS Clamps at an interval of 2 Mtrs. The ends of the pipes shall be closed with brick masonry abutments work so that no cable is exposed, The work shall be carried out as per the instructions of Railway representative at site. (Supply of GI pipes with couplings and laying of cables is not included in this item). [MS angles, flats, bolts and nuts for manufacturing fixing clamps, bricks, sand, cement and all other miscellaneous required for the work shall be supplied by the Contractor].
1.00 Density Polyethylene Duct (PLB-HDPE), 40/33 mm Dia, along with End Cap, End Plug, Cable Sealing Plug and Couplers, as per RDSO/SPN/TC/45/2013 Rev.2 with Amd 3.0 or latest
1.00 in the trenches and in the protective works already provided including in HDD portion and supply pulling of Nylone rope through it at different places as per direction of engineer incharge or site engineer
50.00 DRG.No.SG/SWR/067 or latest guidelines. The lettering on the Cable marker shall be "SIG" / "TELE" / "OFC" as per the instructions of Railway representative at site. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
50.00 300mmX300mm, casting of Concrete foundation of size 300mmX500mmX300mm and Placing of RCC cable markers on top of the foundation and refilling the pit and consolidating it by ramming. The cable markers shall be provided at an interval of 20 Mtrs. within station limits and 50 Mtrs. outside station limits throughout the cable route, diversions and also at every track/road crossing.
4.00 1.5mx1.5m and depth as instructed by Railway representative at site, for coiling the cables in rear of relay rooms/ AFTC huts, apparatus cases etc. The work includes coiling the underground cables, and placing closely one layer of country bricks of size approx. 220mm x 100mm x 60mm breadth wise above the cables to cover all the cables in the cable pit, closing and consolidating the pit by ramming and levelling. [Country bricks of size 220mmx100mmx60mm (approximately) shall be supplied by the Contractor]. Total 490671.00
Item Breakup - A-Signal Chapter-08
300.00 power cables and internal wiring on terminal/ fuse blocks in cable termination Rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing of Hylam sheet 10 mm thick for terminal board, varnishing all teakwood items, fixing of terminals/ fuse blocks on the terminal board, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan, painting of particulars on sleeves. After terminations are over, cable entry at the bottom shall be closed with, cement plastered, the inter-space filled with sand up to base level and the bottom surface shall be sealed with sealing compound. Cable armour to be soldered to earth. (Supply of cable termination racks is not included in this item). [All bolts and nuts with washers, Hylam Sheet 10 mm Thick, cement, sand, stone jelly, Teak wood base, paints and all other miscellaneous materials required for the work shall be supplied by Contractor Total 60600.00
Item Breakup - A-Signal Chapter-15
Installation, Commissioning of Copper Plate Earthing System complete as per Drg.No.SG/SWR/058 with provision of (i) Copper plate 300 mm X 300mm X 3 mm, (ii) Earth Pit 6 ft depth filled up with charcoal 10 kg & salt 25 kg in alternate layers up to 2 ft from bottom, (iii) Water funnel on Perforated GI pipe of length 4.5 ft., (iv) Cast Iron top plate 12 x 12 (v) Drawing of copper - earth from earth to location with 25 mm x 3 mm copper strip for termination (All miscellaneous materials to be supplied by the contractor). Total 233230.00
Item Breakup - A-Signal Chapter-04
2.00 Feed end to suit RE/Non-RE standard as per approved signalling plan. This work includes provision of double bonding and parallel jumpers, provision of bond wire clips, wherever required, shifting of relay end and feed end equipments and re- wiring them, provision of track lead connections wherever necessary using 2c x 2.5 sqmm cable, provision of TLJB boxes and termination of jumpers and tail cables in track lead junction boxes, shifting of Track feed/Track relay set wherever required and wiring with PVC 3/0.75mm copper wire. (Supply of TLJB boxes, 2c x 2.5 sq.mm cable and TLJB boxes with stumps is not covered in the item. Existing Track relays, Track Feed Resistance, Track feed battery chargers, B type Chokes and Charged secondary Cells shall use for this work). [Wire PVC 3/0.75mm, PVC/ Nylon bushes for TLJB boxes, PVC sleeves, all types of bolts and nuts with spring and flat washers, teakwood stand for fixing track feed resistance, GI bond wire 8 SWG, Channel bond pins, bond wire clips, paints and all other miscellaneous materials shall be supplied by the Contractor]. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
2.00 Relay end to suit RE/Non-RE standard as per approved signalling plan. This work includes provision of double bonding and parallel jumpers, provision of bond wire clips, wherever required, shifting of relay end and feed end equipments and re- wiring them, provision of track lead connections wherever necessary using 2c x 2.5 sqmm cable, provision of TLJB boxes and termination of jumpers and tail cables in track lead junction boxes, shifting of Track feed/Track relay set wherever required and wiring with PVC 3/0.75mm copper wire. (Supply of TLJB boxes, 2c x 2.5 sq.mm cable and TLJB boxes with stumps is not covered in the item. Existing Track relays, Track Feed Resistance, Track feed battery chargers, B type Chokes and Charged secondary Cells shall use for this work). [Wire PVC 3/0.75mm, PVC/ Nylon bushes for TLJB boxes, PVC sleeves, all types of bolts and nuts with spring and flat washers, teakwood stand for fixing track feed resistance, GI bond wire 8 SWG, Channel bond pins, bond wire clips, paints and all other miscellaneous materials shall be supplied by the Contractor]. Total 18086.00
Item Breakup - A-Signal Chapter-01
4.00 Lighting Unit Red with current regulator, as per RDSO specification No. RDSO/SPN/199/2010 revision 1.1 or latest.
4.00 Lighting Unit Yellow with current regulator, as per RDSO specification No. RDSO/SPN/199/2010 revision 1.1 or latest.
4.00 Lighting Unit Green with current regulator, as per RDSO specification No. RDSO/SPN/199/2010 revision 1.1 or latest.
2.00 Signal Lighting Unit with current regulator, as per RDSO specification No. RDSO/SPN/153/2011 Rev 4.1 or latest.
3.00 dia, 4.6m tall as per latest specification IRS:S 6-81 Rev.3 or latest.
3.00 Shoes to suit CLS pole 4.6m, as per latest specification.
3.00 Pole 140mm dia as per latest specification.
1.00 cast iron with necessary inspection as per latest specification.
1.00 assembly as per RDSO Spec. No. RDSO/SPN/194/2006 Rev .2.0 or latest (Terminal box, mounting socket, hood, side flange and fixing bolt & nut, eye bolt, M12 bolt-3 Nos. and Fixing bolt 08 Nos) HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
2.00 assembly as per RDSO Spec. No. RDSO/SPN/ 194/2006 Rev.2.0 or latest (Terminal box, mounting socket, hood, side flange and fixing bolt & nut, eye bolt, M12 bolt-3 Nos. and Fixing bolt 12 Nos)
3.00 foundation as per Drg.No.SG/SWR/052 using metallic templates, for erection of colour light signals up to 4 aspects. [Foundation bolts, cement, river sand, stone jelly of size 20/25mm dia and all other miscellaneous materials required for the work shall be supplied by the Contractor].
3.00 mounting of colour light signal up to 4 aspects complete on Signal pole/ Off-set bracket, (for LED/ filament bulbs) with lenses, triple pole lamp holder, filament switching units, CLS transformer, current regulators (whichever is applicable), fixing of ladder with platform complete and concreting of ladder shoe, fixing of number plates, marker board, lens guard, fixing of speed limit board wherever necessary,termination of tail cables, wiring of signal unit with PVC wire 3/0.75mm copper, provision of EWS locks, and painting of one coat of red oxide and two coats of aluminium/ enamel paints. When the aspect is fixed on Offset bracket using 'U' bolts and nuts, a through bolt shall be provided by drilling a hole in the signal pole to prevent the offset bracket from sliding down. ['U' bolts and nuts, through bolts and nuts, cement, stone jelly 20/25mm dia, river sand, Signal Collar-rings, wire PVC 3/0.75mm copper, lens-guard, all fixing bolts and nuts, lead wool, paints PVC/Nylon sleeves, enameled number plates. enameled marker boards, EWS locks, and all other miscellaneous materials for the work shall be supplied by the Contractor].
1.00 per latest specification.
1.00 and nuts, erection of Calling On Signals/ 'A' marker lights, termination of tail cables and wiring using wire PVC 3/0.75mm copper, provision of EWS lock, number plates/ marker boards and painting. The work also includes drilling suitable holes on the CLS post and provision of a through bolt with nut to prevent the Offset bracket from slipping down. (Supply of Calling On Signal/ 'A' marker light, LED aspects/holders & bulbs and Off set brackets is not covered in this item). ['U' bolts and nuts, through bolts with nut, wire PVC 3/0.75mm copper, EWS lock, Enameled number plates, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the contractor].
1.00 unit arm - 4 way with mounting sockets, as per latest specification. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
1.00 way complete/ fixing of additional limb to the existing route indicators, termination of tail cables, wiring as per approved circuits diagram using wire PVC3/0.75mm copper, provision of required No of EWS locks, wire mesh, and painting. (Supply of junction type Route Indicators - complete and additional limb is not covered in this item). [3/0.75mm wire PVC, fixing bolts and nuts, EWS locks, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor].
1.00 arrangement for Signals in RE area as per standard practice. The work comprises of providing MS angle frame and wire mesh in order to avoid close proximity of OHE wires. The work also includes provision of earthing wire using 4 SWG GI wires from the screening arrangement up to surface base as per the instructions of Railway representative at site. [All materials required for this work shall be supplied by the Contractor].
2.00 Goods Warning Board as per practice & SEM (Angle/Rail is to be supplied by Railway).
2.00 Calling- On/STOP/BSLB/Legend boards as per practice & SEM (Angle/Rail is to be supplied by Railway).
0.50 required lengths for Various Boards like Goods warning/Calling on/Axle counter & etc (1 PER UNIT= 1 PER TON)
10.00 of markers of G/P/C/A/IB Markers/Number Module plates as per IRSEM DRG.No 19-D10 on MS sheet of thickness 3mm. Miscellaneous materials required for fixing is to be supplied by contractor.
6.00 Colour light Signals complete (upto 4 aspects) with or without Route Indicators, calling on signals, shunt signals etc., carefully without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. The work includes breaking the concrete foundation, closing the resultant pit and resurfacing it by ramming and levelling.
2.00 STOP board/Warning board/ LEGEND boards along with rails, accounting and stacking them neatly at a place as instructed by Railway representative at site. Also, the resultant pits shall be resurfaced and consolidating by ramming and levelling. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
5.00 per standard practice. The work involves scraping of old paint, applying one coat of Red oxide and two coats of Aluminium/ enamel paint on the Signals -complete as instructed by Railway representative at site. [Aluminium paint, red-oxide and all other miscellaneous materials required for the work shall be supplied by the Contractor]. Total 567513.50
Item Breakup - A-Telecom Chapter-15
Installation, Commissioning of Copper Plate Earthing System complete as per Drg.No.SG/SWR/058 with provision of (i) Copper plate 300 mm X 300mm X 3 mm, (ii) Earth Pit 6 ft depth filled up with charcoal 10 kg & salt 25 kg in alternate layers up to 2 ft from bottom, (iii) Water funnel on Perforated GI pipe of length 4.5 ft., (iv) Cast Iron top plate 12 x 12 (v) Drawing of copper - earth from earth to location with 25 mm x 3 mm copper strip for termination (All miscellaneous materials to be supplied by the contractor).
100.00 Core PVC insulated Copper Cable as per IS: 694 for connecting Main Earth Electrode to MEEB in equipment room. Color: Green. Total 103346.00
Item Breakup - A- Signal Chapter-06
2000.00 soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.5 Mtrs. (Laying of cables is not included in this item).
2000.00 0.5m width throughout, with earth after laying of cables, and consolidating the trench by ramming and levelling
of Metre Signaling/Power/Telecommunication cables as per cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc. (Supply of cables is not included in this item).
100.00 thick as per latest specification. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
100.00 for cable laying with offset at both ends and with couplings over RCC Bridges/ Drainage/ Culverts with concrete masonry supports of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall be closed with brick masonry abutments work so that no cable is exposed, the work shall be carried out as per the instructions of Railway representative at site. (Supply of GI pipes with couplings and laying of cables is not included in this item). [Stone jelly of size 20/25mm, bricks, sand, cement and all other miscellaneous materials required for the work shall be supplied by the Contractor].
40.00 DRG.No.SG/SWR/067 or latest guidelines. The lettering on the Cable marker shall be "SIG" / "TELE" / "OFC" as per the instructions of Railway representative at site.
40.00 300mmX300mm, casting of Concrete foundation of size 300mmX500mmX300mm and Placing of RCC cable markers on top of the foundation and refilling the pit and consolidating it by ramming. The cable markers shall be provided at an interval of 20 Mtrs. within station limits and 50 Mtrs. outside station limits throughout the cable route, diversions and also at every track/road crossing.
2000.00 Signalling/Telecom cables to facilitate engineering construction works. Total 578920.00
Item Breakup - A-Signal Chapter-02
4.00 latest specification/drawing.
4.00 as per requirement with key per E type lock to Drg. No. SA.3376IM/Latest and RDSO Specn. No. IRS. S.30/64. Rev.0.
4.00 foundation and erection of Apparatus Case Full size as per Drg. No. SG/SWR/055 and fixing of 2 nos of "E" type locks, one for the front door and another for the back door, fixing of one hard wood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red oxide and two coats of aluminium paints, along with painting of termination and equipment particulars on the doors of apparatus cases as per instructions of railway representative at site. (Supply of apparatus case is not included in this item). [ Foundation bolts & nuts, 'E' type locks, cement, river sand, stone jelly of size 20/25mm, hardwood plank of 37mm thick, paints, varnish, fixing bolts & nuts and all other miscellaneous materials required for the work shall be supplied by the contractor]. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
4.00 existing Full location boxes very carefully without damaging the working cables and Shifting and turning the Full location boxes (Apparatus Cases) to clear of the infringement as instructed by the Railway representative at site. The work includes ensuring the safety of the signaling system, releasing the cable coils to give access for shifting/turning the location boxes. Necessary masonry work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative at site. If the existing earth connections to the location boxes are disturbed, the earth wires shall be properly re- connected. [All materials required for the work shall be supplied by the Contractor].
1.00 Frames of suitable size to Hold up to 20 relays /plug in type HMU as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing of plug boards, relays, resistors and electrolytic condensers on phenolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram and painting the particulars. (Supply of all types of relays, plug boards, connectors, retaining clips and plug in type HMU is not covered in this item ). [Wire PVC copper, 3/0.75mm and 16/0.2mm copper, phenolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, paints, soldering materials, resistors, condensers and all other miscellaneous materials required for the work shall be supplied by the contractor].
6.00 Full/Half location boxes, by carrying out the earth work around the foundation, ramming of the earth, caring out masonry work from bottom of earth work using country stones and cement masonry to prevent the earth from slipping down the bank.
2.00 (Full/ Half/ Quartersize) without damage after releasing the shelf planks, Terminal blocks, Fuse Blocks, Terminal Boards, Relays of all types EKTs, Secondary Cells, power equipment's, 'E' type locks, etc., and breaking the concrete foundation. After releasing, the resultant pits are to be closed and consolidated by ramming and levelling. The released materials shall be accounted and stacked at a place as instructed by Railway representative at site.
20.00 every ten locks. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY Total 270624.00
Item Breakup - A-Telecom Chapter-02
2.00 latest specification/ drawing.
2.00 foundation and erection of Apparatus Case Half size as per Drg, No.SG/SWR/056, fixing one 'E' type lock for the front door and latching arrangement for the back door, and fixing of one hardwood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints. (Supply of apparatus case is not included in this item). [Foundation bolts and nuts, cement, 'E' type locks, river sand, stone jelly of size 20/25mm, 37mm hard wood planks, latching arrangements, paints, varnish, fixing bolts & nuts and all other miscellaneous materials required for the work shall be supplied by the Contractor] Total 65366.00
Item Breakup - A-Signal Chapter-18
Set Design of SWRD in Auto Cad. Initially, contractor shall submit 3 copies for approval of Railways. One set will be returned duly approved for making a fair copy or for re-submission for approval after incorporating the changes as required by Railways. After carrying out changes, three Hard copies to be submitted for Railway Approval. After approval, Auto Cad copies to be submitted in USB pen drive along with approved copy in Tracing film and six copies of final approved drawing (Ammonia Print or print as approved by Railway) in properly bound booklet along with its scanned copy.
Set HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
100.00 the approved Signalling Plan as per RDSO Sig DATE Format. AutoCAD in A3 size. Initially, Contractor shall submit 2 set of documents complete for approval of Railways. One set is returned either duly approved for making a fair copy or for re- submission for approval after incorporating the changes as required by railways. The TOC & Preliminary Check and Certification to be done by the IRSE or IRSTE (license holder). After carrying out necessary changes, two set of 'Hardcopies' are submitted for administrative approval. The final corrected drawings shall be supplied to Railways on 80/90 GSM Tracing film and 2 copies of blue print properly bonded booklets and the soft copy in USB Pen drive.
2.00 117003.00 Core Plan, Cable Termination Rack Particulars, Location Box Particulars, Power Supply Diagram, Track Circuit Bonding Diagram and/or any other drawing on Auto- CAD in A2/A3/ A4, etc. size (as per instructions of Engineer in- charge). Initially Contractor shall submit 2 sets of 'AS PLANNED' documents complete for approval of Railways. One set is returned either duly approved for making a fair copy or fore-submission for approval after incorporating the changes as required by railways. After preliminary approval, execution of work shall be carried out at site. After Completion of work, 2 sets of AS MADE Check Prints are submitted for administrative approval. Railways will return one set to the contractor duly approved with alterations/corrections if any. The contractor shall incorporate Railways alterations/corrections in the tracings without any deviation and submit all tracings complete in all respect along with its soft copies in USB Pen Drive and 6 sets of final completion drawings in properly bound booklets. [For Centralized Electronic Interlocking Stations/Small Stations]
of AUTOCAD 2000 or latest (including contact numbers on the circuit) and submission of negatives in 80/90 gsm tracing paper in 'A3' size along with 2 copies and also the soft copy in compact disks induplicate. First, 2 sets of prints shall be supplied to Railways for checking. One set will be returned by Railways to the contractor for making corrections in AUTOCAD. The final corrected drawings shall be supplied to Railways on 80/90 gsm tracing paper and 2 copies of blue prints and the soft copy in 2 CDs. (Approved Signalling plan will be supplied by Railways for preparing table of control. Approved table of control will be supplied by Railways for preparing circuits diagrams). HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
300.00 of circuit diagrams, contact analysis charts, termination particulars of apparatus cases and cable termination rack, power supply arrangements, relay index board, cable plans, cable route plans, red boundary plans and all other particulars covered under various schedules. All 'As mades' shall be prepared by the Contractor in AUTOCAD 2000 or latest and submitted in CDs. One copy of the 'As mades' check print shall be submitted before Testing the circuits. The final negatives shall be made in tracing sheet (80 to 90 gsm). All 'As mades' except cable plan, cable route plan, bonding diagram & power supply diagram shall be prepared in A3 size. On approval the contractor shall submit along with the negatives, 8 copies in each, duly making booklet neatly bound. Out of 8 sets, 2 sets of drawings and other plans shall be kept in transparent plastic cover (2 sheets back-to-back in one plastic cover) and handed over to Railways. Also, the contractor has to supply one set of As made in 'Reproduction Film'. The approved circuit diagram will be issued by Railways in soft copy as well as two sets of hard copies. Wherever alterations to existing circuits are involved, the existing as-made circuit diagrams will be supplied by Railways either in CDs or RP film. The Contractor shall incorporate the details of all the new wirings and alterations in the CD/ RP film and submit them to Railways. On approval 8 copies shall be made for As- made circuit diagrams also as mentioned above. Total 775424.00
Item Breakup - A-Telecom Chapter-22
100.00 road as per the instructions of Railway representative at site. The work also includes loading and unloading of the materials. Transportation up to 100 Kms. Total 2400.00
Item Breakup - A-Telecom Chapter-21
10.00 conforming to RDSO specification No.IRS- TC 77/2012 Rev 3.0 or latest for quad cable. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
4.00 Shrinkable type complete for 6 quad cables. After the jointing the through cable has to be tested for insulation resistance and loop resistance in presents of Railway Engineer and in case of any defects the jointing has to be done at free of cost by the contractor. [Heat Shrinkable jointing kit conforming to RDSO specification No.IRS-TC 77/2012 Rev 3.0 covered in the supply portion has to be used for this purpose.] The Contractor should supply all other small items free of cost which are required for making a joint. Only gas blower to be used for blowing
of damaging the fiber and provision of joint chamber of 1.2 mtr dia, 60 Cm height and 50 mm thickness with two-piece top cover and bottom cover. with holes for drainage and cable entry (The reinforcement drawing enclosed). This includes backfilling and ramming of the trench after placing the joint closure and cable loop in the chamber without causing any damage to the same and consolidation of soil as well as disposal of soil as per plan and as advised by RailTel Representative.
4.00 joint chambers with dry sand mixed with ant termite chemical as required in specification up to 400mm height and the cover is refixed in position.
10.00 470:1120 ohms or 470:600 ohms or 470:470 ohms as per RDSO spec No. IRS- TC-76-2021 or latest.
4.00 telephone (4Wire/2Wire) as per RDSO specification IRS: TC-78/2020 Ver. 1.1 or latest.
2.00 type, conforming to specification RDSO/SPN/TC/44/2002 Ver. 3.0 or latest.
2.00 Spec. No. IRS/TC/42/20 Ver. 1.0 with latest
2.00 along the railway track. Fabrication of emergency post as per RDSO Drawing No. UBL/SG/CON/6/2004 and fixing of emergency socket post and burying the post to a depth of 1m after entry of cable. The post to be painted with red oxide before installation. This includes termination of derivation cables on termination strip inside the emergency socket, painting of emergency socket post with alternate black and white strips of 6'' width. The paint used should be of standard quality and two coats of paints should be applied. The EMC post should be painted with red oxide base before painting. (rails will be supplied by railways for the fabrication of emergency post)
10.00 Mtrs length as per site requirements. (LS- SC, SC-SC, LC-LC, FC-FC patch cards as per site requirement) Total 193206.00 HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Item Breakup - A-Signal Chapter-07
20.00 conductor 16/02mm to ATC IS:694 to RDSO specification no.IRS.S76/89 Amendment.3 or latest. Each coil of 100 mts length. (Per Unit=Coil) Total 19080.00
Item Breakup - A-Telecom Chapter-20
14.00 power to carry out miscellaneous/sundry works in the office/field between 08.00 hrs and 20.00 hrs of the day and accompanying Railway staff with all expenses of transportation, accommodation, food, consumables etc., with all ascents/descents, taxes, octroi, cess, fess, duties, with contractors tools and plants, materials, consumables, labour, crew, machineries with all lead and lift etc., complete as per special conditions, specification, regulation and as directed by Railway Engineer-in- charge. Total 9436.00
Item Breakup - B-Signal Chapter Non SOR
Supply of double wire signalling rope Kg (Galvanized) 6X19 as per Spen No IRS:S 11/62 with latest amendements. The Galvanized wires to be useful for making ropes with Jute core. The tensile breaking strength 140/160Kgs/m2 and the nominal dia of the wire shall be 6mm.
Supply of TRANSMITTER COIL ( Tx Coil ) Numbers 21/25KHZ suitable for SSDAC/HASSDAC of GG Tronics make, Make: G.G.TRONICS, As per RDSO SPEC.NO: RDSO/SPN/177/2012 (Version.3) or Latest
Supply of Receiver coil ( Rx Coil ) Numbers 21KHZ/25KHZ suitable for SSDAC/HASSDAC of GG Tronics make. as per RDSO spec. No. RDSO/SPN/177/2012 (Ver. 3) or latest.
Supply of electric track drilling machine to Numbers model No. WD-34C Ralli Wolf / Bosch make with suitable Horizontal stand with attachemtns to drill holes of various sizes upto 7mm to 13mm or similar make / Brand Ralli Wolf WD34C. (The machine should work on 110VAC)
Cable terminals fuses, LDs etc meggering the Conductor cables and recording the readings
Engaging mechanical excavators like JCB Hour or other machineries for regarding and levelling the formation , dismantling any infringing structures, clearing and removing debris etc. with all leads and lifts etc. complete and as per the instruction of Railway representative at site (Unit: Hour=per hour) HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Adding additional 35nos of inputs to the Numbers data loggers available at site and wiring
Software modification at central location
Redesign of EI system alterations as Numbers perapproved signalling plan. This involvesredesigning of EI system alteration asper approved signalling plan, supervisionof installation for alterations, testing andcommissioning. Design of Modification ofthe existing interface and interlockingckts including design of the same is alsocovered under this schedule item.Modifications to the application logicsoftware of VDU and MT are under scopeof this item. Alteration to the relay rackswiring as per the approved interface cktsincluding supply of all necessary wiringmaterial/racks at station. FAT and SATare to be carried out as part of thisschedule item Total 7156044.38
Item Breakup - B-Telecom Chapter Non SOR
Supply of VF tapping and termination Numbers transformer 1:2 (50 Hz signalling transformer) as per RDSO specification IRS-TC-22/2021 Acceptable make : Epsilon, Saraswat Enterprises, Digital Com. (Inspection consigne)
Supply of Metal Strip (MS) ofsize 3mm Metre (Thick) x 40mm (Width) in length of 6 meters. (Inspection consigne)
Supply of OFC Splicing (Inspection consigne)
Supply and installation of 48 fibre Joint Numbers enclosure and Splicing of armoured optical fibre cable (48 fiber) conforming to RDSO spec.RDSO/SPN/TC/68/2014 rev2.1or latest. (Inspection consigne)
Supply and Installation of Rack mountable Numbers 12 F Fibre management system (FMS)as per RDSO/SPN/TC-37/2000(rev-3)amdt-1 or latest (Inspection consigne) Total 144229.40
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
InspectionClause_2.pdf
ATTACHMENT
TenderBookSpecialCondition.pdf
ATTACHMENT
IRGCC-2022with_ASC1TO11_compressed.pdf
ATTACHMENT
TechnicalGuidelinesPCSTE.pdf
ATTACHMENT
ConservancyCharges.pdf
ATTACHMENT
AnnexureVGCCcorrespondence_1.pdf
ATTACHMENT
TelecomTechnicalspecification.pdf
ATTACHMENT
TechnicalBook.pdf
ATTACHMENT
JPO
ATTACHMENT
InclusionofnewJPOinWTTLettertoPCOM01.05.2024withencloser-pages_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid