| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 LAccepted-AOC LIG 10 VIVEK NAGAR NAVIBAGH BHOPAL MADHYA PRADESH 462038 | BHOPAL | MADHYA PRADESH | 462038 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹17.0 L+₹3.9 L (29.8%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹18.7 L+₹5.6 L (43.1%)Rejected-Finance 00 A N SINHA ROAD KADAM KUAN PATNA BIHAR 800003 | PATNA | BIHAR | 800003 | L3 | Rejected-Finance Other than lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
3 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE BHOPAL
GE Bhopal, Bairagarh, Bhopal
DAY TO DAY MAINT OF EM SERVICES AT BAIRAGARH UNDER GE BHOPAL
2020_MES_375156_1
8717/E8
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
BHOPAL
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE BHOPAL
₹40,000
Yes
23 Nov 2020
5 Sept 2020
5 Oct 2020
5 Sept 2020
3 Oct 2020
19 Sept 2020
60 days
Amount
NOTE: - (i) The works/items given below are for attending day to day complaints (of int. electricfication, fans, geysers, etc) by deploying sufficient skilled trades men/materials and making functional the complaint. (ii) The quoted rate deems to include for all minor expenses required for making the complaint functional. (iii) The trades man shall report to E/M complaint cell Bairagarh daily at 8.30 am to take complaints from concren JE E/M. The complaint must be attended on same day in stuiplate time period by providing material required and by deploying sufficient manpower by the contractor. The complaint slip duly signed by the user shall be returned back at the complaint cell with proper feed back in the evening. (iv) The tradesman deployed for work shall wear proper uniform with full shirt and full pant with their names & contractors name on the uniform. Colour code of uniform will be decided by Engineer-in-charge.
S&F in repairs Switch piano, flush type, single pole, one way, 6 Amps, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/ LEGRAND/ HAVELLS as approved by GE]
S&F Switch piano, flush type, single pole, one way, 6 Amps, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/ LEGRAND/ HAVELLS as approved by GE]
S&F in repairs Socket outlet multipurpose having provision for 2 & 3 pin, 6 Amp flush type, 240 volt AC complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/ LEGRAND/HAVELLS as approved by GE]
S&F Socket outlet multipurpose having provision for 2 & 3 pin, 6 Amp flush type, 240 volt AC complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/ LEGRAND/HAVELLS as approved by GE]
S&F in repairs switch socket combination outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, piano flush type, 230 volt AC complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/ LEGRAND/ HAVELLS as approved by GE]
S&F switch socket combination outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, piano flush type, 230 volt AC complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/ LEGRAND/ HAVELLS as approved by GE]
S&F in repairs Ceiling rose surface bakelite, three terminals, 240V, 50Hz, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/ LEGRAND/ HAVELLS as approved by GE]
S&F Ceiling rose surface bakelite, three terminals, 240V, 50Hz, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/ LEGRAND/ HAVELLS as approved by GE]
S&F in repairs Bell push, flush type, 6 Amp piano type, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA PC series) or equivalent in LEADER/ CRABTREE/ LEGRAND/ HAVELLS as approved by GE]
S&F Bell push, flush type, 6 Amp piano type, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA PC series) or equivalent in LEADER/ CRABTREE/ LEGRAND/ HAVELLS as approved by GE]
S&F in repairs Buzzer, electric, single phase, 240 volt, AC complete all as specified and as directed. [MAKE:-ANCHOR (PENTA PC series) or equivalent in LEADER/ CRABTREE/ LEGRAND /HAVELLS as approved by GE]
S&F in repairs Bell, Ding Dong type, electric, single phase, 240 volt, AC complete all as specified and as directed. [MAKE:-ANCHOR (PENTA PC series) or equivalent in LEADER/ CRABTREE/ LEGRAND /HAVELLS as approved by GE]
S&F Bell, Ding Dong type, electric, single phase, 240 volt, AC complete all as specified and as directed. [MAKE:-ANCHOR (PENTA PC series) or equivalent in LEADER/ CRABTREE/ LEGRAND /HAVELLS as approved by GE]
S&F in repairs lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings with & including LED lamp white 9 watt retrofit, 230 volts complete all as specified and directed. [MAKE FOR HOLDER:-ANCHOR (PENTA PC series)/ LEADER/ CRABTREE/ LEGRAND /HAVELLS as approved by GE] & LAMP : BAJAJ/PHILIPS/SYSKA]
S&F lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings with & including LED lamp white 9 watt retrofit, 230 volts complete all as specified and directed. [MAKE FOR HOLDER:-ANCHOR (PENTA PC series)/ LEADER/ CRABTREE/ LEGRAND /HAVELLS as approved by GE] & LAMP : BAJAJ/PHILIPS/SYSKA]
S&F sheet metal enclosure for MCB, DB, VTPN 415 Volts 200 amps rated busbar 4 way Double door ( Vertical DB ) factory made Conf to IS:13032 fabricated out of CRCA sheet not less than 1.2mm thick fitted with DIN channel , neutral link and 200 amp , 440 volt rated bus bar .DB shall be semi glossy finished with epoxy polyster based powder paint sprayed (RAL 9003) and baked at high temperature with anti rust conditoning protection against corrosive atmosphere . IP 43 protection class . DB shall also be provided with lable marking indicating the incoming and outgoing circuit .complete all as specified and directed. Make Legrand/ Seimens/ Schinder.
S&F sheet metal enclosure for MCB, DB, VTPN 415 Volts 200 amps rated busbar 4 way Double door ( Vertical DB with MCB as incomer) factory made Conf to IS:13032 fabricated out of CRCA sheet not less than 1.2mm thick fitted with DIN channel , neutral link and 200 amp , 440 volt rated bus bar with 63 amp MCCB as incomer .DB shall be semi glossy finished with epoxy polyster based powder paint sprayed (RAL 9003) and baked at high temperature with anti rust conditoning protection against corrosive atmosphere .DB shall also be provided with lable marking indicating the incoming and outgoing circuit IP 43 protection class complete all as specified and directed. Make Legrand/ Seimens/ Schinder.
S&F sheet metal enclosure for MCB, DB, VTPN 415 Volts 200 amps rated busbar 6 way Double door ( Vertical DB with MCB as incomer) factory made Conf to IS:13032 fabricated out of CRCA sheet not less than 1.2mm thick fitted with DIN channel , neutral link and 200 amp , 440 volt rated bus bar with 100 amp MCCB as incomer .DB shall be semi glossy finished with epoxy polyster based powder paint sprayed (RAL 9003) and baked at high temperature with anti rust conditoning protection against corrosive atmosphere .DB shall also be provided with lable marking indicating the incoming and outgoing circuit IP 43 protection class complete all as specified and directed. Make Legrand/ Seimens/ Schinder.
S&F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 amps rated busbar, 12 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, including wooden rectangle board of first quality of suitable size for mounting of DB box complete all as specified and directed. Make- Legrand/ Seimens/ Schinder.
S&F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 amps rated busbar, 8 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 including wooden rectangle board of first quality of suitable size for mounting of DB box complete all as specified and directed. Make- Legrand/ Seimens/ Schinder.
S&F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 amps rated busbar, 4way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 including wooden rectangle board of first quality of suitable size for mounting of DB box complete all as specified and directed. Make- Legrand/ Seimens/ Schinder.
S&F in repair MCB/MCCB TPN 40 to 63 Amps, 10 KA 'C' Curve breaking capacity, including connection with suitable size aluminium / copper lugs complete all as specified and directed. Make- Legrand/ Seimens/ Schinder.
S&F in repair MCB SP 240 volts 5 to 40 Amps, 10 KA breaking capacity, 'C' Curve including connection with suitable size aluminium / copper lugs complete all as specified and directed. Make- Legrand/ Seimens/ Schinder.
S&F in repair MCB SPN 5 to 32 amps 10 KA , 'C' Curve including connection with suitable size aluminium / copper lugs complete all as specified and directed. Make- Legrand/ Seimens/ Schinder.
S&F stepped type electronic fan regulator 100 watt flush type (delux) on the existing hylem laminated sheet etc as required complete all as specified and directed. Make: Anchor (Delux) / L&T/ Havells
S&F of stepped type electronic fan regulator 100 watt flush type (delux) on the existing phenolic laminated sheet etc as required complete all as specified and directed. Make: Anchor (Delux) / L&T/ Havells
S&F LED 20/21 Watt tube light fitting (T8 type) , including LED retrofit tube 20/21 W , 240 v, PF > 0.90, colour Temp 6500 K, System Luminious efficacy > 100Lm/W, complete with powder coated CRCA decorative box type batten suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm two core, and PVC round block white colour, 2 Nos for mounting of fitting including taking down old light fitting any type complete all as specified & directed. Make :-CG /wipro/Havells/ Philips as approved by GE.
S&F in repairs LED tube light rod 20/21 Watt (reterofit type, T8 pattern, single side connection) 240 V, PF > 0.90, colour Temp 6500 K, System Luminious efficacy > 100Lm/W, to be fixed in existing or new batten/ patti including taking down of existing tube light fitting and changing the wiring suitable for T8 LED retrofit lamp in existing tube light fitting complete all as specified & directed. Make :- Wipro / Havells/ Philips as approved by GE.
S&F in repairs electronic ballast 1 x 36 watt, 240 V, 50 HZ. complete all as specified & directed. Make : CG/Bajaj/ Philips. Note:Ballast replaced without taking down of fitting shall be measured under this item
Taking down existing u/s fitting any type any size and S&F LED 9/10 Watt mirror tube light fitting intergated type, 240 v, PF > 0.90, colour Temp 6500 K, suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm two core, and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified & directed. Make :-C&S /n Wipro/ Philips/ Crompton as approved by GE.
S&F in repair LED lamp 12 Watt 4 Pin type, retrofit type in existing fitting with necessary change in wiring including taking out unserviceable CFL /LED lamp any watt from light fitting complete all as specified and directed. Make : Wipro/Syska/CG
S&F LED 9/10 Watt bathroom mirror tube light fitting intergated type, 240 v, PF > 0.90, colour Temp 6500 K, suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm two core, and PVC round block white colour x 2 Nos for mounting of fitting including taking down existing u/s fitting any type any size complete all as specified & directed. Make :-C&S /Wipro/ Philips/ Crompton as approved by GE.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 4.0 sqmm nominal cross section area and drawing into and including rigid non metallic PVC conduit 25mm dia, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. 20mm external diameter and PVC insulated stranded copper conductor of 4 sqmm nominal cross section area as earth wire complete all as specified and directed. [Make of Cable : Polycab/ Plaza/ Havells/KEI/V-MARC as approved by GE] Note: - Two runs of 4.0 sqmm cable, one run of 4.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 6.0 sqmm nominal cross section area and drawing into and including rigid non metallic PVC conduit 25mm dia, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. 20mm external diameter and PVC insulated stranded copper conductor of 6 sqmm nominal cross section area as earth wire including taking down old unserviceable sub main wiring complete all as specified and directed. [Make of Cable : Polycab/ Plaza/ Havells/KEI/V-MARC as approved by GE] Note: - Two runs of 6.0 sqmm cable, one run of 6.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 4.0 sqmm nominal cross section area and drawing into and including rigid non metallic PVC casing caping not less than 25mm dia, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. 20mm external diameter and PVC insulated stranded copper conductor of 4 sqmm nominal cross section area as earth wire complete all as specified and directed. [Make of Cable : Polycab/ Plaza/ Havells/KEI/V-MARC as approved by GE] Note: - Two runs of 4.0 sqmm cable, one run of 4.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 6.0 sqmm nominal cross section area and drawing into and including rigid non metallic PVC casing caping not less than 25mm dia, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. 20mm external diameter and PVC insulated stranded copper conductor of 6 sqmm nominal cross section area as earth wire complete all as specified and directed. [Make of Cable : Polycab/ Plaza/ Havells/KEI/V-MARC as approved by GE] Note: - Two runs of 6.0 sqmm cable, one run of 6.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 4.0 sqmm nominal cross section area and drawing in existing surface/recessed steel/PVC conduit/PVC casing caping and PVC insulated stranded copper conductor of 4 sqmm nominal cross section area as earth wire complete all as specified and directed. [Make of Cable : Polycab/ Plaza/ Havells/KEI/V-MARC as approved by GE] Note: - Two runs of 4.0 sqmm cable, one run of 4.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
M&L for point wiring for one light / fan / bell point with 1.50 sqmm (nominal area) FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable, 1100 volts grade, controlled by one one-way switch, drawn in and including non metallic rigid PVC casing capping not less than 25mm base size with all fitting and fixing accessories including one run of 1.5 sqmm copper conductor as earth continuity wire connected to common earth dolly by suitable lugs, sunken sheet steel terminal box made out of 1.20 mm thick GI/MS sheet for mounting of fittings like switches, sockets, fan regulators, etc. with 3mm thick laminated hylum sheet cover complete all as specified and directed. [Make of Cable : Polycab/ Plaza/ Havells/KEI/V-MARC as approved by GE] Note : Wiring to be done as per approved colour code in IE rule.
All as per BOQ item No.39.00 above, but for 3 pin 5 Amp socket outlet on independent board complete all as specified and directed.
All as per BOQ item No.39.00 above, one 5 Amps socket outlet point controlled by one switch on same board with other switches complete all as specified and directed.
All as per BOQ item No.39.00 above, but wiring with 2.5 Sq mm copper cable for 5/15 amp switch socket combination on or 3 pin socket out let 15 amp independent board and provision of 1.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
All as per BOQ item No.39.00 above, but wiring with 4 Sq mm copper cable for 5/15 amp switch socket combination on or 3 pin socket out let 15 amp independent board and provision of 4 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
M&L for point wiring for one light / fan / bell point with 1.50 sqmm (nominal area) FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable, 1100 volts grade, controlled by one one-way switch, drawn in existing concealed conduit including one run of 1.5 sqmm copper conductor as earth continuity wire connected to common earth dolly by suitable lugs and 3mm thick laminated hylum sheet cover including taking old point wiring (any type without conduit) complete all as specified and directed. [Make of Cable : Polycab/ Plaza/ Havells/KEI/V-MARC as approved by GE] Note : Wiring to be done as per approved colour code in IE rule.
All as per BOQ item No.44.00 above, one 5 Amps socket outlet point controlled by one switch on same board with other switches complete all as specified and directed.
All as per BOQ item No.44.00 above, but for 3 pin 5 Amp socket outlet on independent board complete all as specified and directed.
All as per BOQ item No.44.00 above, but wiring with 2.5 Sq mm copper cable for 5/15 amp switch socket combination on or 3 pin socket out let 15 amp independent board and provision of 1.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
Supply and replacement of 3 pin plug top AC-230 v 15 Amp. complete all as specified and directed. Make : Anchor/ L&T/Havells
Supply and replacement of PVC insulated PVC sheathed, flexible circular cable 3 core, 2.5 Sqmm strandered copper conductor AC 230 V complete all as specified and directed. Make Havells/ Palza/ Polycab/Anchor
Dismantling geyser of any capacity and of any description, M&L for cleaning and de-scaling the inner tank and other parts / accessories including inlet, outlet, overflow, geyser element, thermostat, U assembly etc. with brush & cleaning rods and using and circulating concentrated de-scaling solution mixed with water in suitable proportion till the complete deposits/scale is removed and approved by the Engineer-in-Charge, fixing the serviceable parts in position, replacing the unserviceable parts, setting insulation properly as required, reassembling the complete geyser after cleaning, fixing & installation of the geyser in position and its testing to the entire satisfaction of Engineer-in-Charge complete all as specified and directed. NOTE:- (i) De-scaling chemical shall be concentrated HCL of make as approved by GE. (ii) The quoted rates includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts will be measured and paid for separately under appropriate item of BOQ.
Supply and fixing the following spares of geyser in repair and testing after replacing the defective part for proper functioning of gyser complete all as specified and directed.
Thermostat ISI marked Make : Danfoss / Ranco / Indfoss
Triangle Heating element 1.5 KW, ISI marked Make : Bajaj / Usha/Theta
Triangle Heating element 2 KW, ISI marked Make : Bajaj / Usha/Theta
Indicator lamp with flexibe copper wire of suitable size Red/Green
Round Heating element 1.5 KW, ISI marked Make : Bajaj / Usha/Theta
Round Heating element 2 KW, ISI marked Make : Bajaj / Usha/Theta
PVC Connection with steel reinforced pipe for hot water connection of Size 18" x 1/2" including rubber washers.
Taking down unserviceable sub main wiring including service connections, of any size and any description including conduit pipe and making good disturbed surface of wall/ceiling to match with existing surface after necessary rewiring complete all as specified and directed.
Taking down carefully existing point wiring (any type viz. aluminum or copper) with wooden batten/surface PVC conduit (with its fittings)/PVC casing-capping or any other type for light, fan, power point (including switch, socket, ceiling rose, etc.) and making good disturbed surface of wall/ceiling to match with existing surface after necessary rewiring complete all as specified and directed.
Taking down old unserviceable MCB DB of any size and capacity including wooden boards complete all as specified and directed.
S&F in repair socket outlet 6 pin 5/15 Amp multi purpose flush type complete all as specified and directed. [MAKE:-ANCHOR (PENTA PC series) or equivalent in LEADER/ CRABTREE/ LEGRAND /HAVELLS as approved by GE]
S&F in repair switch paino flush type 15 Amp complete all as specified and directed. [MAKE:-ANCHOR (PENTA PC series) or equivalent in LEADER/ CRABTREE/ LEGRAND /HAVELLS as approved by GE]
S&F in repair single phase direct connection type KWH meter , temper proof, plastic body with LCD display, 230/240V, 5-30 Amp, accuracy class I, 50 Hz, Conf to IS 13779, IP 54, with ( parameters to show Date, time, current reading, KW, PF) in existing position by providing wooden board wooden board first quality of size 250 mm x 300 mm, including making complete elctric connections complete all as specifed and directed. Make : Secure/HPL/ L&T Note : Old meter to be deposite in AGE E/M store.
S&F in repair Three phase direct connection type KWH meter , temper proof, plastic body with LCD display, 230/240V per phase , 5-30 Amp, accuracy class I, 50 Hz, Conf to IS 13779, IP 54, with ( parameters to show Date, time, current reading, KW, PF) in existing position by providing wooden board first quality of size 250 mm x 300 mm, including making complete elctric connections complete all as specifed and directed. Make : Secure/HPL/ L&T Note : Old meter to be deposite in AGE E/M store.
S&F in repair Three phase direct connection type KWH meter , temper proof, plastic body with LCD display, 230/240V per phase , 10-60 Amp, accuracy class I, 50 Hz, Conf to IS 13779, IP 54, with ( parameters to show Date, time, current reading, KW, PF) in existing position by providing wooden board wooden board first quality of size 250 mm x 300 mm, including making complete elctric connections complete all as specifed and directed. Make : Secure/HPL/ L&T Note : Old meter to be deposite in AGE E/M store.
S&F single pole and neutral enclosure with two pin and earth, plug and socket, suitable for single phase 240 V, complete with one single pole MCB of capacity 20 amps (SPN) having `C` charactristic, breaking cap 10 KA, including industial plug top, complete all as specified and as directed. Make : Legrand / Schinder/ L&T.
S&F in repairs laminated hylum sheet cover, ISI marked of Make" Hylem" cut with grooves for mounting of fittings like switches, sockets, fan regulators etc. including fixing in location with new galvanised screw and cup washer complete all as specified and directed of following sizes :
11 x 13 inches
9 x 11 inches
5 x 8 inches
5 x 5 inches
Taking down old ceiling fan/Exhaust fans/Wall mounting fan of any cap/sweep after disconnecting the electric supply from any site, checking for its electrical defect and opening fans for checking of mechanical defect after dismentlling of fan, carried out repair/over hauling including removing dust and grease, and cleaning of internal mechanical parts of fan with kerosene oil, checking of alignment of shaft, oiling and greasing, checking of worn out bearing and other defective parts, winding, condenser etc and re-assembling, and connecting/refixing of fans in its original position by providing new GI nut bolt, lock washer and lock/split pin complete all as specified and directed by Engr-in-charge. NOTE: (i) Rewinding and replacement of defective parts, Painting etc shall be measured and paid seperately
S&F the following new parts suitable for ceiling fan, exhaust fans, wall mounting fans of any description, any sweep as repaired under under serial No. 62.00 of BOQ complete all as specified and directed. :- NOTE:-The new parts shall be suitable to match with the existing.
Ball Bearing No 6201 (set of two) [Make:SKF/NBC/FAG as approved by GE]
Ball Bearing No 6202 (set of two) [Make:SKF/NBC/FAG as approved by GE]
Condenser 2.5 mfd [Make: Epcos/Tibcon as approved by GE]
Condenser 4.0 mfd [Make: Epcos/Tibcon as approved by GE]
M&L for rewinding of ceiling fan of sweep 1200 mm with suitable gauge copper winding wire (super enamelled) including all insulating material after necessary heat varnishing, testing, etc. complete all as specified and directed.
M&L for rewinding of exhaust fan of 280/300 mm, 1400 RPM with suitable gauge copper winding wire (super enamelled) including all insulating material after necessary heat varnishing, testing, etc. complete all as specified and directed.
Supply and fixing of Panel light, square type 2 ftX 2ft of 40 W, color temperature 3500 - 4100 K, AC 220 -240 V, 50 Hz, High surge Protection 2.5 KV, ISI, Lumen>4000, working lifetime hour 50000 pc lens for better light distribution including nut, LED lamp, wire all connecting accessories complete all as specified and directed. Make: Philips/wipro/bajaj
Deduct schedule of credit (calculation will be done off line) Rs. 44,770.00
M/s VIKAS TRADERS
UMESH ENTERPRISES
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .