Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.0 LAccepted-AOC N A | NEW DELHI | DELHI | 110001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹49.0 L+₹2.2 L (4.81%)Rejected-Finance | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹53.3 L+₹6.5 L (13.8%)Rejected-Finance | L3 | Rejected-Finance HIGHER BIDDER | |
| 4 | L4₹56.1 L+₹9.3 L (20.0%)Rejected-Finance | L4 | Rejected-Finance HIGHER BIDDER | |
| 5 | L5₹56.3 L+₹9.5 L (20.4%)Rejected-Finance | L5 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
21 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI BIJENDRA SHARMA IDSE EE
GARRISON ENGINEER (NW) VASCO Opposite KV No.2, School, Shantinagar, Vasco-Da-Gama, Goa-403802
8553/E8
2023_MES_600303_1
8553/E8
Open Tender
Civil Works
Item Rate
180 days
VASCO
Class D Category a i
7 documents required · 7 mandatory
₹500
GE NW VASCO
₹90,000
Yes
31 Jul 2023
2 Jun 2023
23 Jun 2023
2 Jun 2023
21 Jun 2023
16 Jun 2023
2 Jun 2023 - 15 Jun 2023
Amount
Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and as directed.
S & F framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete confirming to Fe 410 - W (Gde- E- 250) quality - A complete all as specified and as directed.
All as per item No 2 above but erection, fixing and fabrication only
Dismantling mild steel work of any description not otherwise provided for complete all as specified and as directed.
S & F Mild steel roof trusses (framed), Trussesd, purlins, crane grantries, rails and framings and heavy bracket framing (Beam,tee, angle, channel or flat sections) confrming to Fe 410-W including cleats,distance pieces etc complete all as specified and as directed.
M & L for running welding in repairs thickness of metal to be welded exceding 6 mm but not exceeding 9mm complete all as specified and as directed.
Welding in repairs thickness of metal to be welded exceding 9 mm but not exceeding 20 mm and exc 2.5cm but n exc 5cm in length complete all as specified and as directed.
Overhauling the bottom wheel and existing gear system of bottom wheel of hanger steel door incl dismantling from the steel door and refixing in the same position incl derusting cleaning and greasing of wheel & bearings without taking down door complete all as directed to make in serviceable condition.
All as per item No 8 above but incl replacement of two bearings
Overhauling the top wheel including derusting , cleaning and greasing including dismantling and opening of bearing and making serviceable for smooth functioning of door complete all as directed without taking down shutter .
S&F bottom wheel of hangar in cast iron including bush bearing axle and all other necesssary items as per the existing design after taking down the shutter including replacement of existing wheel with new wheels.
All as item above but top wheel complete all as specified and as directed.
S&F for sealing holes around 'J'/'L' bolts in CGI sheets roofing of hangers/building with using silicon solution doctor fixit or wilson 10 all as per manufacturer instructions and as directed.
M&L for taking out old bolts from any type of roof and sealing with one bitumen and one curved GI washer on either side and provision of new J/L hooks/6mm dia GI bolts and nuts all set in stiff white lead all as directed.
M&L for taking out old bolts from any type of wall cladding and sealing with one bitumen and one curved GI washer on either side and provision of new J/L hooks/6mm dia GI bolts and nuts all set in stiff white lead complete all as specified and as directed.
M&L to bottom wheel of hanger steel door with replacement of bush bearing axle and tighting to crank and chain greasing to wheel crank and chain to make it serviceable for smooth run incl replacement of existing wheel with new wheels.
Preparing new surfaces of iron and steel and applying one coat of redoxide zinc chrome primer and two coats of Epoxy anti- corrosive paint for surface over 10 cm width or girth complete all as specified and as directed.
M&L for preparation of old steel surface and applying one coat of Epoxy anticorrosive paint over 10 cm width or girth complete all as specified and as directed.
Taking down eves, gutters and rain water pipe (any size or pattern) incl all fittings,heads, shoes,bends and swan neck etc incl cleaning for refixing or removal
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls.
S&F PVC (SWR) bends of 110mm radius
Supply & fixed PVC 1/2 rounded gutters of 60cm with union sockets to jointes set in approved jointing compound complete all as specified and as directed.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 200mm dia complete all as specified and as directed.
S&F for PVC plain bends 200mm bore complete all as specified and as directed.
Dismantling/Taking out existing hessain base felt of any other existing water proofing treatment from roof including cement plaster and exposing the top surface of RCC slab including removing dust, dirt and washing the roof and removing the dismantled debris to a distance exceeding 200 m but not exceeding 3000m at a height n.exc 1.5m above starting point complete all as specified and as directed.
M&L for applying evenly & priming with oil bound bituminius primer at 0.4Ltr per sqm for water proofing treatment complete all as specified and as directed.
M&L for APP based polymeric membrane minimum weighing 3Kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application completed all as specified.
Providing 10mm thick plaster in CM (1:4) mixed with 3% integral water proofing compound over roof top surface finished to even & smooth w/o using extra cement. Note :- Integral water proofing compound will be measured and paid seperately
Disconnecting existing tank, setting aside (or lowing if required) for repairs, cleaning etc and hoisting if required reconnecting and refixing in position ( Cleaning repairing, etc. measured separately) capacity in lters exc 250 ltr & n exc 500 liter
Disconnecting existing tank, setting aside (or lowing if required) for repairs, cleaning etc and hoisting if required reconnecting and refixing in position ( Cleaning repairing, etc. measured separately) capacity in ltrs exc 500 ltr & n exc 1000 liter
Dismantling water tanks and removing to store any capacity complete all as specified and as directed.
M & L Rotational moulded polyethylene water storage tanks 500 ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I
M & L Rotational moulded polyethylene water storage tanks 1000 ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I
Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 20 mm dia complete all as specified and as directed.
All as per item No 34 but of 25 mm dia
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified of dia 20 mm.
Ditto as the item mentioned above but of 25 mm dia
S & F Stop valve 20mm dia of PTMT any colour high pressure screwed for iron pipe and fixed in repairs. (Minimum weight 15mm-90gms complete all as specified and as directed.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding/roof gutter/wall, made to shape as required, fixed with self tapping screws as specified
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Fixing only Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified (Except Sheet)
Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
Dismantling of stone slabs and tiles laid dry or laid dry and pointed of any description or thickness in floors or aprons
Dermolition of cement concrete unreinforced in ground floor and pavings n exc 15cm thickness below or above GL
M&L Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set over cm 1:6, 20mm thick screed bed and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L Glazed ceramic tiles in vertical surface 300x 200x 7 mm/ 450X 300X 7mm thick fixed over cm 1:4, 10mm thick backing coat set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and as directed.
M&L Cement concrete type C- 2, 1:3:6 (40mm graded aggregate) 75mm thick as in sub base of flooring/plinth protection all as specified
M&L sand filling in floors for laying interlocking paver block
S&F machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 60mm thickness M-40 grade with grey cement and pigment complete all as specified and as directed.
Taking down chowkat or frames n exc 1.5 sqm each (w/o taking off shutters from the frame) complete all as specified and as directed.
Taking down chowkat or frames exc 1.5 sqm but n. exc 4 sqm each (w/o taking off shutters from the frame and removing to store) complete all as specified and as directed.
S&F aluminium powder coated door, windows & ventilation shutters and frame any type (sliding or openable) with frame and other similar work etc 60 microns including applying acrylic emulsion sealant along aluminium window frame side to fill the gap between aluminium frame and walls/jambs
S&F 4mm thick sheetglass ordinary quality exceeding 0.5 sqm each pane complete all as specified and as directed.
S&F Powder coated aluminium grill of design DG-104 pattern, made out of 10mm dia rod fixed with and including stranded aluminium frame of 'F' section of size 23.4x15.3x1.4 mm thick all as per manufacturer's instructions complete all as specified and directed
S&F butt hinges medium weight stainless steel 100mm size complete all as specified and as directed.
Extruded aluminium alloy handles, fabricated type, anodised 150 mm size complete all as specified and as directed.
Aluminium anodised, barrel tower bolts of extruded section and fixed 150mm size complete all as specified and as directed.
Door closer hydraulically regulated, aluminium extruded body designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and as directed.
Aluminium alloy, anodised, sliding door bolt 250mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed.
Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor with overall length of cover plate 140 mm complete all as specified and as directed.
M & L taking down aluminum door shutters of any size and repairing/replacing the damaged or broken brass chromium plated pivot PVC gasket lining around and refixing the shutters in original position as directed complete all as specified and as directed.
M & L taking out old damaged aluminum door shutters and repairing/replacing the damaged aluminum angles inside the styles/rails of a aluminum doors and refixing the shutter in original position including necessary nut and bolts as directed.
Dismantling of existing steel rolling shutters including top covers for repairs & refixing in the same opening after repairs including greasing the spring, guide channel shafts, bearing, bolts, washers, including repairing defective laths spring bearing , hood cover, guide channel suspension shafts etc complete for rolling shutter of clear area upto 7 Sqm each complete all as specified and as directed. Note:- Necessary spares will be measured & paid seperately.
All as per item No.53 above but rolling shuters area exc 7.00 sqm but not exc 10 sqm
All as per item No.53 above but rolling shuters area exc 10 sqm but not exc 20 sqm
Supply only Ball bearing for rolling shutter.
Supply only in repairs Steel rolling shutters of 1.25 mm thickness laths without ball bearing as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer erected in position as indicated push & pull or manual type complete all as specified and as directed.
S & F in repairs Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: with bevel gear box and crank handle 1.25mm thick complete all as specified and as directed.
M&Lfor preparation of old/new steel surfaces of any description over 10cm width or girth and applying one coat of aluminium paint First quality all as directed and specified complete all as specified and as directed.
Demolition of stone /boulder masonry, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
Pre - cast cement concrete 1:3:6 type C-1, (20mm graded stone aggregate) block masonary with solid blocks built in cement mortar 1:6 complete all as specified and as directed.
M/L rendering 15 mm thick in CM 1:6 on concrete solid block wall internal surface finished even and smooth without using extra cement complete all as specified and as directed.
Taking down cement plaster of any description on brick or stone walls including racking ouit joint hacking for key, scrubbing down with water etc.
M&L preparation of surfaces by washing down with water and applying a coat of acrylic polymer bonding agent @ 0.50 Ltr per SQM and applying first coat of cement plaster in CM 1:4, 10mm thick with in half an hour when bonding agent becomes tacky. Afetr proper curing apply second coat of plaster in cement mortar 1:4, 5mm thick mixed with and incl 100ml of liquid water proofing compound per bag of cement all as per manufacturer's instructions, finished even and smooth without using extra cement
M&L for applying two coats of water proofing treatment by using araldite builder barrier coat or equivalent @ 5 Sqm per Ltr for first coat and 6 Sqm per Ltr for second coat (alongwith suitable pigments for colour as directed by Engr-in-Charge all as specified in manufacturer's instructions and to be applied through applicator of authorised manufaturer with 5 Years guarantee.
Providing and applying 5.3mm ESD-Epoxy antiskid floor coating system including surface preparation by cleaning surface from dust, dirt, muck,moisture and all foreign material and cleaned by mechanical means using mechanical scrubber/grinder, chemical treatment for cleaning oil if required followed by application of primer Nitoprime 25 of Fosroc or equivalent in Sika/Bostik which shall be a two component, epoxy based system. The pre packed and factory weighed two components shall be mixed for 3 mins using a low speed drill and applied at 5.5 - 6.5 m2/ltr @ 200 microns thick. Then providing and applying the screed layer with Nitoflor EU5 of Fosroc or equivalent in Sika/Bostik at minimum thickness of 3000 [email protected] m2/pack @ 2mm thickness. The self levelling screed shall consist of a low viscous epoxy system and graded aggregate ( special silica/Filler). The pre packed components shall be mixed as per the packing ratio and applied. The epoxy underlay shall achieve a minimum compressive strength of 60 N/mm2, Flexural strength of 20 N/mm2 and Tensile strength of 10N/mm2 @ 7 days. The underlay shall have nil water absorption when tested as per BS1881 Part 122-1983. Then over the screed apply copper tape of 100microns thick and 25mm width, connected to existing earth pit having spacing 10m both directions, then conductive primer coat Nitoflor SL of Fosroc or equivalent in Sika/Bostik Conductive Basecoat shall be applied at a thickness of 100 microns and then top coat of 2000microns - Nitoflor SL conductive of Fosroc or equivalent in Sika/Bostik shall be applied to provide Approx approx. 3x103 - 9 x103 Ohm Surface resistance . Which shall be supplied in pre-weighed packs and ready to mix and use which will consist of resin, hardner, EPI (colour concentrate) formulated aggregate and carbon fibre + special anti skid silica sand/Filler. All these to be mixed in the pre weighed ratio, add EPI colour (colour concentrate) and formulated aggregates + special antiskid silica sand/Filler to agitate the mixture by an elecrically driven motor and lay the mixture to the thickness of 2000 microns then deaerate by using spike rollers and to allow to cure for a minimum period of 48 hours before trafficking is commenced. Over top coat demarcation paint with flourescent will be applied.
M&L for Cutting out existing damaged concrete slab with cutter in proper rectangular, square or triangular shape including wahsing existing surface of slab with (0.5N) hydrochloric acid 2.5 Ltr /10 sqm and applying epoxy resin primer 0.34 Kg/Sqm and finally applying epoxy resin mortar comprising of one part of epoxy resin and seven parts of quartz sand mix No 10 by weight laying and levelling in proper shape to flush with existing slab complete all as directed. Make: Fosroc/STP
M&L cutting and racking out joints with cutter and cleaning with blower and making sides of joints bitumen free for all joints and sealing the joints with, Hydrocel XL of Fosroc or equivalent in Sika/Bostik High performance, cross linked, closed cell,non-absorbent, polyethylene joint fi ller, then filling the top gap with polyurethane based sealant Colpor 200 PF of Fosroc or equivalent in Sika/Bostikover a coat primer including bond breaker caulked tightly into base of sealing groove complete all as per manufacturers instructions and as directed by Engr-in-charge.Size of joints:- 30 mm x 15 mm
M & L for providing & applying white or yellow (Aisle) band Marking with 2 component polyeurathane resin + Hardner with flourescent (FK 666) on applied EPU flooring
S&F in repair PVC bird proofing net in green colourt of size 28mm x 28 mm x 4mm thick weight not less than 650gms/sqm and MS flat size 40mm x 3mm fixing with MS angle 50x50x6 mm etc all as specified and directed by Engr-in-charge. Note: MS flats and MS angles will be measured separately.
S&F in repairs embossed translucent polycarbonate skylight corrugated sheet of 2 mm thickness as in roof covering, fixed with self tapping screws all as specified and directed.
S&F prefabricated crimp curved galvanized roof sheet (colour coated) of required thickness(0.40 mm to 0.80 mm as in roof covering, fixed with self tapping screws and to match with existing cladding and roof sheet all as specified and directed.
Taking down and refixing of prefabricated crimp curved galvanized roof sheet (colour coated) as in roof covering, fixed with self tapping screws all as specified and directed.
M&L for forming dummy/contraction joints 100mm deep and 8mm to 10mm wide at spacing not more than 4m c/c in 175mm concrete pavement and sealing the joints with polyurethene based sealant Seal N flex FC (grey colour) over a coat of N49 primer including bond breaker caulked tightly into the base of sealing groove complete all as per manufactures instructions up to 15mm deep and 8mm thick over 12mm dia polythene rod over 70mm depth bituminous filler board after priming the concrete sides with two coats of primer shall be applied with a thin brush by the forward and backward movement before pouring the sealent with primer of same make, complete all as specified. Make BOSTIK Note : (i) Edges of joints shall be rounded up by mechanical means at the time of final cutting. (2) Initial cutting shall be carried out within 24-36 hours of casting. (3) Final cutting, rounding of edges, use and waste of back up rod to avoid deposition of foregion materials in the joint upto final filling of joints shall be carried out after 28 days . (4) Applying masking tape on the edges of joint to prevent accidental slippage of sealant on top surfaces and to give a neat finish to the sealant and removing the masking tape after sealant is applied as required.
Forming 12 mm thick expansion joints 100 mm thick filled with performed bituminous filler and top 30 mm primed and sealed with sealing compound grade “A” all as specified.
Forming for contraction (Dummy) joints 65 mm deep and 10mm wide filled with sealing compound grade “A” all as specified.
CVS CONSTRUCTIONS
M/S Kartik Enterprises
Paulraj Painters And Civil Engineering Contractors
SHIVRAJ CONSTRUCTIONS
M/s VEEJEE ENTERPRISES
KIRAN TRADERS
SHREE THATWAMASSY CONSTRUCTIONS PRIVATE LIMITED
M/s RAJ CONSTRUCTION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .