Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.7 LAccepted-AOC HENGRABAI LICHUBAGAN BYE LANE 2 HOUSE NO 2 GUWAHATI 781036 ASSAM | KAMRUP METRO | ASSAM | 781036 | L1 | Accepted-AOC Reasonable rate | |
| 2 | L2₹60.0 L+₹5.1 L (9.27%)Rejected-Finance 4 9 359 P 14 BESIDE SAI BABA TEMPLE RTC COLONY HAYATH NAGAR HYDERABAD 501 505 | HYDERABAD | HAYATH NAGAR | TELANGANA | 501505 | L2 | Rejected-Finance Quoted amount higher than L1 | |
| 3 | L3₹60.5 L+₹5.7 L (10.3%)Rejected-Finance NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | L3 | Rejected-Finance Quoted amount higher than L1 | |
| 4 | L4₹65.7 L+₹10.8 L (19.6%)Rejected-Finance 3 1 4 GOPINATH BAZAR DELHI CANTT 110 010 | NEW DELHI | DELHI | 110010 | L4 | Rejected-Finance Quoted amount higher than L1 | |
| 5 | Rejected-Technical RONALDSAY ROAD JOYMAGAR BUS STAND AGARTALA WEST TRIPURA | AGARTALA | WEST TRIPURA | TRIPURA | - | Rejected-Technical Not fulfilled the NIT criteria |
Tender Value
₹60 L
EMD Value
₹1.1 L
Closing Date
17 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col N K Chaudhary
HQ 137 WKS ENGR PIN 914137 CO 99 APO
SPECIAL REPAIR/REPLACEMENT OF 33/11 KV POWER TRANSFORMER 1600 KVA CAPACITY AND OTHER CONNECTED ITEMS AT MILITARY STATION AGARTALA
2023_MES_617000_1
8783/E8
Open Tender
Civil Works
Item Rate
180 days
Agartala
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
AGE (I) Agartala
₹1.1 L
Yes
30 Jan 2024
4 Sept 2023
24 Nov 2023
4 Sept 2023
17 Nov 2023
3 Nov 2023
Amount
Disconnecting electric Supply and dismounting the Power transformer of 33/11KV, 1600 KVA alongwith with connecting terminals and deposit to MES E/M store yard by transporting without damage Note:- Transportation charges, handling charges, tools and plants charges are deemed to be included in the quoted rate.
Supply, installation, testing and commissioning of 1600KVA, 33 KV/11 KV, Outdoor duty, 3 phase, 50Hz with On Load Tap Changing arrangements with remote control panel operation on 33 KV sides to vary secondary voltage from +5% to (-) 15% in steps of 1.25% (16Steps & 17 positions), impedance 6.25% at normal/common tap No 5. HV terminals 3 Nos outdoor bare bushings with sockets and LV terminals with cable Box arrangement for 11KV HT XLPE Power cable of size 300 sqmm x3 core with copper conductor and LV additional Neutral with one no solid porcelain type out door bushings with sockets on the transformer lid for earthing purpose complete in all respects with standard accessories and fittings conforming to IS-2026 primary side delta and secondary side star. The salient features of the transformer shall be as below :- (i) Transformer shall be Dyn11 vector group oil immersed naturally cooled, doubled wound electrolytic copper winding core type, Radiator cooled MS tank complete with first fill of transformer oil as per IS -335 with ONAN cooling system. The temperature rise of oil shall be 50°C and temperature rise of winding shall be 55°C above ambient of 50°C. Transformer shall be paint shall be as per RAL 7032. (ii) Rating and diagram plate
(iii) Earthing terminals - 2 Nos. (iv) Lifting lugs (v) Thermometer pocket. (vi) Air release hole with plug. (vii) Oil filling hole with plug on & incl. conservator with drain valve and plug. (viii) Plain type oil indicator on one side of conservator with minimum and maximum oil level marking. (ix) Dehydrating breather - 01 No (x) Oil conservator with drawn valve and plug. (xi) Sampling valves, top and bottom. (xii) Under base with flat treaded bi-directional rollers. (xiii) Drain cum bottom filter valve with plug. (xiv) Top filter valve with plug. (xv) Explosion vent with diaphragm and equalizer pipe or Pressure release device. (xvi) Jacking lugs and hauling holes. (xvii) Inspection cover. (xviii) Detachable radiators with shut off valves between radiators and tanks. (xix) Radiator with air release hole and plug. Oil drain hole with plug and lifting eye all as per manufacturer's standards.
(vi) Raise / low limit switch. (vii) Retainer switch. (viii) Stepping Relay. (ix) Anti - condensation heater with switch. (x) Inter locking between manual and electric operation. (xi) Main isolating switch with set of fuses. (xii) Insulated terminal board (with connector) for transformer tap leads. (xiii) Mechanical tap position indicator with handle. (xiv) Tap changing operation counter, (xv) Rating plate. (xvi) Driving mechanism chamber locking arrangement. (xvii) Un -drilled gland plate for cable entry. (xviii) Terminal strips. (xix) Drain cum filter valves. NOTE :- (a) Single limb IMPULSE TEST AND HEAT RUN TEST shall be carried out at Manufacturer's factory and the rate for the same is deemed to be included in the quoted rate. (b) Foundation and civil works as per manufacturer's recommendation and cost for the same is deemed to be included in the quoted rate. Note:-(i) Power transformer to be placed in suitable location and its Bi-directional roller to be locked properly. (ii) The contractor shall furnish original purchase voucher, test certificate and warranty certificate of the transformer from manufacturer.
(iii) The contractor shall submit the general arrangement drawing of transformer and get the approval of Accepting officer for make and drawing of transformer before placing the order. (iv) Transformer shall be dispatched only after inspection at manufacture premises to be done by OEM auth and MES auth at manufacturer premises. Routine test as per IS relevent is to be carried out at factory in presence of MES Rep. (v) Contractor shall submit the operating manual and maintenance schedule of transformer form in two sets. (vi) Anything missed out in the technical specifications but technically required for efficient working of the transformer is deemed to be included in the quoted rate.
Material and labour earthing complete with copper earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.50 metre below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt, earth electrode copper strip of size 20x3mm to copper earth plate electrode by means of bolts, nuts, check nuts and washers of galvanized iron and thimbles and other end of earth wire connected to main switch board and protected by galvanized iron light grade 40mm bore and GI pipe 20mm bore medium grade with funnel and wire mesh for watering including necessary excavation and earth works. concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:1.5:3) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) and all as shown in Electrical Plate No. 3 of SSR (Part-1)of 2009. Including taking down of existing unserviceable earthing complete all as specified. (Note:- (i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost from the department.
Supply, laying connecting and testing XLPE insulated (Earthed) cable in trenches / or fixed on pole etc in screened PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy duty) with stranded alluminium conductor, 11000 volts grade, cross sectional area 95 Sqmm, 3 core, Confirming to IS-7098 (Part-II) 1985 including taking down of existing unserviceable XLPE cable complete all as specified and as directed. (Note :-Earth work, PCC cable protection cover, sand cushioning and GI Pipe will be measured and paid separately under respective item.
Material and Labour for cable termination jointing kit for 11 KV(Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm including taking down of existing unserviceable jointing kit complete all as specified and directed.
Material and Labour cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm including taking down of existing unserviceable jointing kit complete all as specified and as directed
Material and Labour for 80mm bore GI pipe light grade for cable protection ISI marked with all fittings and fixed complete to walls and ceilings or laid in floors including taking down of existing unserviceable GI pipe complete all as specified and as directed.
Excavation in trenches not exceeding 1.50 m wide and n.exc1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed.
All as per item No 08 above but depth exc 1.5m but n.exc 3m complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cms thick in soils complete all as specified and as directed.
Removing excavated material to a distance n.exc 50M and deposited/ spreaded where directed at a level n. exc 1.5 M above the starting point complete all as specified and as directed .
Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down to 18 cm thickness complete all as specified and as directed.(Punned thickness shall be measured)
Supply and laying unreinforced precasted concrete cable cover class HVP type 1 with peak size 300mm x 180mm x 40mm in trenches for protection of UG cable with width equal to length of PCC cover, laid dry and flat complete all as specified and as directed.
Material and labour for PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
Materials and labour for providing cement concrete Type B1 1:2:4 ( 20 mm graded aggregate) as in coping of poles including weathering, slightly rounded or chamfered angles and throating including necessary form work all as specified and as directed.
Material and labour for Loose filling with aggregates of gauge 40 to 80 mm in Main receiving station for insulation in outdoor transmission periphery complete all as specified and as directed .
Supply and fixing of Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp for 11 KV including dismanteling of old unservicible lightning arresters complete all as specified and directed.
Boring under roads with mechanical arrangement with 80 mm dia GI tubing without disturbing the top surface of the road for passing the cable across the road complete all as specified and directed.
Supplying and laying synthetic Rubber insulated mats 3 mm thick for voltage upto 33 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed.
Supply and fixing triple pole mechanically operated air break switch (GOD), vertical mounting, rotating type, mounted on insulator and steel frame with operating mechanism worked from ground level complete in all respect such as gun metal moving contacts and spring loaded gun metal fixed jaws, knife copper jumper strip etc, suitable for 11000 Volts grade, 50 Hz with 9 insulator of rating upto 200 Amps including taking down of existing unserviceable GOD of any type complete all as specified and as directed Note :- Design / drawing of HT pole showing the layout and dimension is to be obtained from OEM/auth dealer/supplier and same is to be got approved from Engr-in-charge and GE before placing order to the manufacturer.
SHRI GANESH ENTERPRISES
PURBANCHAL BUILDERS
RAVINDRA BROTHERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .