Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 LAccepted-AOC 487 A 1 GOPAL MISHRA ROAD BEHALA KOLKATA 700034 | KOLKATA | WEST BENGAL | 700034 | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.9 L+₹651 (0.08%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹7.9 L+₹1,394 (0.18%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹16,000
Closing Date
25 Jan 2024, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE, FAWS-I, EM, KMDA
OFFICE OF THE EXECUTIVE ENGINEER, FAWS-I, E/M SECTOR, KMDA, Makardah Road, Dasnagar, Howrah - 711105
Repair and Maintenance of submersible Pump-Motor sets with its accessories and all Electro-Mechanical Components of 22 Nos Pump Houses for Twelve (12) months under Bankra-Santragachi FAWS Scheme.
2024_KMDA_638730_1
EE(E/M)/FAWS-1/2W - 25/ 23 - 24/84
Open Tender
Electrical Work/ Equipment
Item Rate
365 days
Bankra-Santragachi
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹16,000
13 Nov 2024
15 Jan 2024
29 Jan 2024
15 Jan 2024
25 Jan 2024
15 Jan 2024
Amount
Charges for complete rewinding of 3 ph, 440 v 50 HZ submersible p/m 20 HP/15 KW set by pvc copper winding wires, after dismantling the winding including testing commissoning as per the direction of EIC.
Withdrawing the sub P/M set (upto 25 HP) along with column pipe from the well after disconnecting the all accessories for necessaary testing/checking/repairing purpose. (including hire charges of Chain Pulley Block, Derrick arangement, Labour charges and transportation cost).
Installation of pumping machinery with valves, pipe & pipe specials short piece, depth gauge, pressure gauge including hoisting of column pipe, making all electrical and water line inter-connection complete as per direction including supply of necessary materials as reqd. for the work.
Straigh through Jointing of cable of different size by compound jointing kit including S&F ferrul, tapes and jointing materials (Brand approved by EIC). 3,3½ / 4 core upto 35 sqmm cable.
Supply and delivery of thermal overload relays range 30-50A.Make: L&T/Siemence/Equivalent.
Supply and fixing of 240/230 volt,50Hz, T.P, power contactor range 50-85A).Make:L&T/Siemence/ABB/Equivalent.
Supply and fixing of spare contract kits for 240/415 volt,50Hz, T.P, power contactor.
Supply and fixing of electronic timer suitable for 240/415 volt,50Hz, range 3.0 to 30 second range.
LED single tube light fitting with all accessories.Model-TMC 501p1xT-LED 22wp324.(make-Philips)
Supply and fixing of analog Ammeter ranging 0-100Amps having C.R ratio of 100/5A, 144 mm sq size.
Supply and fixing of analog voltmeter ranging from 0-500 V of 144 mm sq size
Supplying and fixing 100/125 A Sheet steel Main Switches on angle iron frame on wall
Supply of protective device comprising of wire rope clamps etc.
Supply of fabricated MS Kiosk made from 14 SWG MS Angle incl. Providing Al busbar of 60 A rating for main supply transmission with proper stamping and to be fixed on pedestal as per direction of EIC.
Supply, fitting fixing of cast iron gate with gun metal sheet on both face of sl. valve as per sample incl. charge of material machining & labour complete.
Supply, fitting fixing brass spindle with gun metal lock nut for best quality for sliuice Valve.
Replacement by S&F of gland packing suitable for Sluice Valve.
Fitting fixining of all type of valve in proper position by provinding temporary support gasket nut bolt cmplete & direction of eic.
S & D of Sub. Copper cable of 3 core 6 sq mm 1100 V grade.
S & D at site/store of Sub pumping machineries Set directly coupled with 3 ph 400 V (+-10%), 50 Hz AC, RPM-2900 wet winding type Sub Motor having Cr. Steel impeller and SS Shaft, Capacity 110-50 m3/hr., Head range-40-60 m(nominal head 50 m), P-20 HP and delivery size 100-125mm. as per direction of EIC.
Supply & delivery of 5” (125 mm.) I.D. and OD 140 +- 0.20 mm, 10.2 mm. avr. wall Thickness, 10’(avr. 3.0 mt) long standard (16kg/cm2) PVC column pipes with both end tapered and threaded portion length must be 4'' with one end to be fitted with heavy gauge 10 to 13 mm. Thick , 8” long threaded pvc. socket ,all are completed as per direction of Eic.
S & D of 125 mm dia / 150 mm dia (5"/6") standard duty MS Adoptor.Mk-Ashirbad/C.R.I./Raksha or equivalent .
CI doble flange type NRV face to face IS 5312 hinge pin SS 410 driling IS 1538 pressure rating PN 1.0 Mk-IVC/Sree Durga/Fluid Tech/Sigma flow size125/150mm.
C.I sluice valve with flanged ends drilled to as per I.S. 1358/62 and having all cast iron components as per I.S. 780/71 solid forged bronze inside screw spindle having ultimate tensile strength not less than 4.72 MT per sq. cm. Spindle nut valve and seat faces of hard wear resisting, manufactured from best quality gun metal conforming to I.S. 780/71, painted black all over with asphalt base paint tested to 21 kg (hydraulic pressure) per sq. cm., valve opening to anticlockwise direction, fitted and fixed completed. size-125/150 mm. Mk-IVC/Sree Durga/Fluid Tech/Sigma flow.
Checking of all the Electrical and mechanical parts and preventive and break down and predictive maintenance of all pump machinery as per the direction of Eic.
A) Electrician(Skilled labour).
B) Contractor profit shall be included in item Sl. No. 25.01
NB: Old and unserviceable material are to be submitted at store under FAWS-1 Division otherwise deduction will be applicable as per prevailing norms of Authority
NGM INTERNATIONAL
M U ENGINEERING WORKS
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .