Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 CrAdmitted-Finance | ₹2.6 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.7 CrAdmitted-Finance | ₹2.7 Cr | L2 | Admitted-Finance |
| 3 | L3₹2.8 CrAdmitted-Finance | ₹2.8 Cr | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Gaikhonlung Panmei L3 | Yumkham Subhaschandra Meetei L1 | Sophila Muinao L2 |
|---|---|---|---|---|---|---|
| 1.00CIVIL COMPONENTS | ||||||
| 2.00SH:A - Beautification of pond | ||||||
| 3.00 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil. | 41.6 | m3 | 569 ₹23,670.40 | 533 ₹22,172.80 | 559 ₹23,254.40 |
| 4.00 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | 13.87 | m3 | 239 ₹3,314.93 | 224 ₹3,106.88 | 235 ₹3,259.45 |
| 5.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a) C.C. 1:5:10 (1 cement :5 coarse sand :10 graded stone aggrt. 40mm nominal size). | 13.56 | m3 | 9,870 ₹1.3 L | 9,242 ₹1.3 L | 9,687 ₹1.3 L |
| 6.00 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 Kanhaighat sand:3 graded stone aggregate 20 mm nominal size.) | 28.2 | m3 | 15,438 ₹4.4 L | 14,449 ₹4.1 L | 15,153 ₹4.3 L |
| 7.00 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc.above plinth up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5kanhaighat sand:3 graded stone aggregate 20 mm nominal size.) | 9.59 | m3 | 17,121 ₹1.6 L | 16,025 ₹1.5 L | 16,804 ₹1.6 L |
| 8.00 | Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level.(a) Thermo-Mechanically Treated bars. | 3,066.4 | Kg | 140 ₹4.3 L | 117 ₹3.6 L | 138 ₹4.2 L |
| 9.00 | Centering and shuttering including strutting, propping etc. and removal of form for:(a) Foundation footings, bases of columns etc. and mass concrete. | 214.82 | m2 | 559 ₹1.2 L | 524 ₹1.1 L | 549 ₹1.2 L |
| 10.00 | (b) Columns, Pillars, Piers, Abutments, Posts and Struts. | 153.44 | m2 | 1,154 ₹1.8 L | 1,082 ₹1.7 L | 1,133 ₹1.7 L |
Tender Value
₹2.6 Cr
EMD Value
₹5.1 L
Closing Date
27 Jan 2026, 2:00 pmClosed
Executive Engineer-IV
MPHC Office Complex
Development of Eco-Tourism site at Mantripukhri Khongnang Makhong, Imphal East District, Manipur
2026_MPHCL_3226_1
04/EE(I/E)/MPHC/2025-26
Open Tender
Civil Works
180 days
As per tender documents
As per tender documents
3 documents required · 3 mandatory
₹25,000
MD MPHC Ltd.
₹5.1 L
30 Jan 2026
21 Jan 2026
27 Jan 2026
22 Jan 2026
27 Jan 2026
22 Jan 2026
22 Jan 2026 - 27 Jan 2026
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a) C.C. 1:5:10 (1 cement :5 coarse sand :10 graded stone aggrt. 40mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 Kanhaighat sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc.above plinth up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5kanhaighat sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level.(a) Thermo-Mechanically Treated bars.
Centering and shuttering including strutting, propping etc. and removal of form for:(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, Pillars, Piers, Abutments, Posts and Struts.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :.(i) Water thinnable cement primer
Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing walls with Acrylic smooth exterior paint of required shade : (i) New work (Two or more coats applied @ 1.67 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
Providing & fixing Steel Grill by using 16x16 mm solid Square section as main bars horizontally and vertically readily available at Market i/c painting,Priming etc. complete as per direction of Engineer-in-Charge.
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
Supply, installation, testing and commissioning of 8 mtr. High hot dip galvanised octagonal poles with 130 mm bottom A/F & 70 mm top A/F made up of 3mm thick HT sheet along with base plate of size 200x200x12 mm thick with complete foundation as reqd. (Without bracket).
S/F G.I. bracket 1 mt. long single arm etc.as reqd
S/D of 2.5 sq mm FR Cu. Conductor.
SITC LED Street Light 60W 757K made of pressure dia housing with toughened glass and individual high power LED with secondary optics IP66 protection & impact resistance of (Havells) ENDURAPEARLPLUS 60W complete with all accessories i/c connection etc. as reqd
S/F (following way) single/double pole and neutral, sheet steel MCCB distribution board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar detachable gland plate, interconnection, phophatized and powder painted i/c earthing etc. as reqd ( but without MCB/RCCB/Isolator) (a) 2+6 way
Supplying & fixing ( following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp.
Earthing with copper plate 600x600x6mm thick i/c accessories and providing masonary enclosure with copper plate having locking arrangement and watering pipes etc.(but without charcoal and salt complete as reqd.)
Extra for using salt and charcoal for G.I. plates or copper pates earth electrodes as reqd
P/F 4.00 mm dia copper wire on surface or in recess for loop earthing as reqd
P/L 25mm2 4- core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 250mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
Supply and installation of premier finger and columner jet fountain 3 nos. F-nozzles 4nos. C nozzles with 3 HP submerssible/floating etectric pump set i/c 7x3 50W lamps colour glass gasket light stand cable standard panel board fuse internal wiring and outdoor electrical enclosure necessary boards as rqd with the direction of Engineer in charge.
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sandy soil under floors including,watering,ramming consolidating and dressing complete with a lead of 15 Km
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a) C.C. 1:5:10 (1 cement :5 coarse sand :10 graded stone aggrt. 40mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 Kanhaighat sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc.above plinth up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5kanhaighat sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 kanhaighat sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level.(a) Thermo-Mechanically Treated bars.
Centering and shuttering including strutting, propping etc. and removal of form for:(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, Pillars, Piers, Abutments, Posts and Struts.
(c) Lintels, beams, plinth beams, girders, bressumers and cantilevers,with water proof ply 12mm thick.
Brick work with Ist class common burnt clay F.P.S. (non modular)bricks in foundation and plinth in: (i) (1 Cem: 4kanhaighat sand)
(a) Upto 1st floor level
Providing and fixing in position collapsible steel shutters with vertical channels 20xl0x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia, steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved brand and manufacture in all colours and shades, laid on 20mm thick cement mortar 1:4(1 cement: 4 c/ sand)jointing with grey cement slurry @3.3 kg/m including grouting the joints with white cement and matching pigments etc., the tiles must be cut wth the zero chipping diomond cutter only. laying of tiles will be done with the notch trowel,plier,wedge,clips of required thickness,levelling system and rubber mallet for placing gently and easily.(a) Double charge vitrified tile polished finish of size(i) Size of Tile 600 x 600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete.(i) Size of Tile 600x600 mm
Providing and fixing M.S. round holding down with nuts and wahser plates completes
Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm)with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trussesand including cutting to size and shape wherever required with (i) Precoated galvanised iron profile sheets 0.50 mm thick
Providing and fixing precoated galvanised steel sheet roofing accessories , Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : (i) Ridges plain (500 - 600mm). (a) Precoated galvanised iron profile sheets 0.50 mm thick.
(a) Fully Perforated Gypsum Plaster Board of size 1200 x 2400 x 12.5mm having approx. 15% perforated size and pattern as approved by the Engineer-in-charge and as per manufacter's specification,with all 4 sides tapered and backed by acoustical tissue with NRC value not less than 0.60.
Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc.complete. (a) Electric resistance or induction butt welded tubes
12 mm cement plaster of mix 1:4 (1 cement : 4 kanhaighat sand).
15mm cement plaster on rough side of single or half brick wall of mix (i) 1:4 (1 cement : 4 Kanaighat coarse sand).
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :.(i) Water thinnable cement primer
Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing walls with Acrylic smooth exterior paint of required shade : (i) New work (Two or more coats applied @ 1.67 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 c/ sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
P/F 2mm thick M.S.Sheet eave board with ISA 25x25x4mm and flat 25x4mm with primer and painting complete as per direction of Engineer-in- Charge.
15 mm cement plaster 1:3 (1 cement: 3 kanhaighat sand) finished with afloating coat of neat cement on the roughside of single or half brick wall.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
2X1.5mm2+1X1.5mm2 earth wire
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F 12W LED bulb
S/F surface/ pendent mounting 1x18 W LED lamp channel luminories complete with all accessories connection etc as required.
S/F fan hook i/c bolt & nuts.
S/F 48"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) bladesetc.as reqd. (Make Bajaj/Usha/Crompton/Orient)
S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc.
SITC 50W LED 5000K energy saving IP 65 Flood Light luminaries with high power LED as light source Havell's JETACOMPECTOFL50W LED 757LTG complete with connection as rqd. (Havell's)
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+4 way
(a)10 amp MCB "C" Curve
(a)20 amp MCB "C" Curve
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 60 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
P/F 300x400x60mm(n/size) with permissible variation of plus minus 5mm in size wooden board complete with locking arrangement and painting etc.
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
Supply & Fixing swaged type steel tubular pole 8 mtr. Long as per 410 SP 14.conforming to IS 2713 (Pt.II) 1980 with bracket in cement concrete 1:3:6 (1:cement:3c/sand:6 gr. st. 40 mm n/size) foundation i/c excavation and refilling etc. as requred.
Supply and drawing of AB Cable of size (3x50 + 1x35) mm2
Cross arm 70X40mm/2 wire.
Back clamp for Cross arm 70X40mm
S/F stay set complete with stay wire & stay insulator etc.as reqd.
SH:C1 - Construction of Cafeteria
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sandy soil under floors including,watering,ramming consolidating and dressing complete with a lead of 15 Km
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a) C.C. 1:5:10 (1 cement :5 coarse sand :10 graded stone aggrt. 40mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 Kanhaighat sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc.above plinth up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5kanhaighat sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 kanhaighat sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level.(a) Thermo-Mechanically Treated bars.
Centering and shuttering including strutting, propping etc. and removal of form for:(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, Pillars, Piers, Abutments, Posts and Struts.
(c) Lintels, beams, plinth beams, girders, bressumers and cantilevers,with water proof ply 12mm thick.
(d) Suspended floors, roofs, landings, balconies and access platform,with water proof ply 12mm thick.
(e) Edges of slab and breaks in floors and walls (i).Under 20 cm wide.
Brick work with Ist class common burnt clay F.P.S. (non modular)bricks in foundation and plinth in: (i) (1 Cem: 4kanhaighat sand)
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in : (i) cement mortar 1:4 (1 cement : 4 kanhaighat sand)
(a) Upto 1st floor level
Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : (a) Local best quality Teak wood.
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked MS pressed butt hinges bright finished of required sizes with necessary screws..(a) Local best quality Teak wood.(a) 35mm thick.
Providing 40x3mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts, nuts and wooden plugs and embedding to cement concrete block 30x10 x15cm 1:3:6 (1 cement : 3 c/coarse sand : 6 stone aggrt. 20mm nominal size).
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :
Providing and fixing bright finished brass tower bolts (barrel type)with necessary screws etc. complete : (a) 250x10 mm
Providing and fixing bright finished brass handles with screws etc. complete :(a) 125mm
Providing and fixing in position collapsible steel shutters with vertical channels 20xl0x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia, steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved brand and manufacture in all colours and shades, laid on 20mm thick cement mortar 1:4(1 cement: 4 c/ sand)jointing with grey cement slurry @3.3 kg/m including grouting the joints with white cement and matching pigments etc., the tiles must be cut wth the zero chipping diomond cutter only. laying of tiles will be done with the notch trowel,plier,wedge,clips of required thickness,levelling system and rubber mallet for placing gently and easily.(a) Double charge vitrified tile polished finish of size(i) Size of Tile 600 x 600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete.(i) Size of Tile 600x600 mm
Providing and fixing M.S. round holding down with nuts and wahser plates completes
Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm)with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trussesand including cutting to size and shape wherever required with (i) Precoated galvanised iron profile sheets 0.50 mm thick
Providing and fixing precoated galvanised steel sheet roofing accessories , Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : (i) Ridges plain (500 - 600mm). (a) Precoated galvanised iron profile sheets 0.50 mm thick.
Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections, power pressed from M.S. sheet and galvanised with zinc coating of 120 gms/ sqm (both sided inclusive) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm diax50mm long with 6mm dia bolts,other flange of cleat fixed to the angle hangers of 25x25x0.55mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I. channels 45x15x0.9mm running at the spacing of 1200mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction,including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with 25mm long drive-all screws @ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishng to a flush finish of tapered
and square edges of the board with recommended jointing compound,jointing tapes, finishing with jointing compund in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board,all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, and specification and direction of the Engineer in Charge but excluding the cost of painting with : (a) Fully Perforated Gypsum Plaster Board of size 1200 x 2400 x 12.5mm having approx. 15% perforated size and pattern as approved by the Engineer-in-charge and as per manufacter's specification,with all 4 sides tapered and backed by acoustical tissue with NRC value not less than 0.60.
Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc.complete. (a) Electric resistance or induction butt welded tubes
12 mm cement plaster of mix 1:4 (1 cement : 4 kanhaighat sand).
15mm cement plaster on rough side of single or half brick wall of mix (i) 1:4 (1 cement : 4 Kanaighat coarse sand).
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :.(i) Water thinnable cement primer
Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing walls with Acrylic smooth exterior paint of required shade : (i) New work (Two or more coats applied @ 1.67 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
Applying priming coat :- (a) With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
Providing and fixing kitchen sink including making all connections excluding cost of fittings. i )White glazed fire clay sink of size 600x450x250 mm
Providing & fixing M.S. grills of required pattern to wooden frames vertically and horizontally with M.S. flats at required spacing & frames based on Architectural drawing i/c priming,painting etc. Complete as per direction of Engineer-in-Charge.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 c/ sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
15 mm cement plaster 1:3 (1 cement: 3 kanhaighat sand) finished with afloating coat of neat cement on the roughside of single or half brick wall.
P/F 2mm thick M.S.Sheet eave board with ISA 25x25x4mm and flat 25x4mm with primer and painting complete as per direction of Engineer-in- Charge.
Providing and fixing precoated galvanised steel sheet roofing accessories , Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : (i) Gutter (600mm over all girth). (a) Precoated galvanised iron profile sheets 0.50 mm thick.
SH:C2- Providing WS & SI for Cafeteria
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level(a) 1:4:8 (1 cem :4c/ sand:8 graded stone aggrt.40mm n/size).
(b) 1:2:4 (1 cem :2c/sand:4 graded stone aggrt.20mm n/size).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 kanhaighat sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level.(a) Thermo-Mechanically Treated bars.
Centering and shuttering including strutting, propping etc. and removal of form for(a) Suspended floors, roofs, landings, balconies and access platform,with water proof ply 12mm thick.
(b) Edges of slab and breaks in floors and walls (i).Under 20 cm wide.
Brick work with Ist class common burnt clay F.P.S. (non modular)bricks in foundation and plinth in: (i) (1 Cem: 4kanhaighat sand)
15 mm cement plaster 1:3 (1 cement: 3 kanhaighat sand) finished with afloating coat of neat cement on the roughside of single or half brick wall.
P/F C.I. Cover with frame (for manhole and chambers) (i) 600 mm x 450 mm (heavy duty) (38 Kg)
Providing and fixing wash basin with C.I. brackets, 15 mm C.P.brass pillar taps, 32 mm C.P. brass waste of standard pattern,including painting of fittings and brackets, cutting and making good the walls wherever required: (a) White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (a) External Works.
(i) 25 mm nominal outer dia Pipes
(i) 32 mm nominal outer dia Pipes
(i) 80 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.(A) Concealed work, including cutting chases and making good the wall (i) 15 mm nominal outer dia Pipes
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :(a) 15 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :(i) 25 mm nominal outer dia Pipes
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (A). Kitchen sink without drain board (i) 610x460 mm bowl depth 200 mm
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
SH:C3 - Providing IEI in Cafeteria
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with modular type switch , modular Plate suitable size MS-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X1.5mm2+1X1.5mm2 earth wire
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing switch box/cover i/c connection etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
S/F surface/ pendent mounting 1x18 W LED lamp channel luminories complete with all accessories connection etc as required.
SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver 15 W 840 LHEAAGP6IA2W012 complete with connection as rqd. (Havell's)
S/F fan hook i/c bolt & nuts.
S/F 48"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) bladesetc.as reqd. (Make Bajaj/Usha/Crompton/Orient)
S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc.
Installation of exhaust fan upto 450mm sweep in the existing opening i/c making the hole to suit the size of the above fan, making good the damaged, connection testing commissioning etc. as reqd.
S/F 305mm sweep exhaust fan complete with accessories i/c connection etc. as reqd.
SITC 50W LED 5000K energy saving IP 65 Flood Light luminaries with high power LED as light source Havell's JETACOMPECTOFL50W LED 757LTG complete with connection as rqd. (Havell's)
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+4 way
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
(a)10 amp MCB "C" Curve
(a)20 amp MCB "C" Curve
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 60 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
P/F 300x400x60mm(n/size) with permissible variation of plus minus 5mm in size wooden board complete with locking arrangement and painting etc.
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
Supply & Fixing swaged type steel tubular pole 8 mtr. Long as per 410 SP 14.conforming to IS 2713 (Pt.II) 1980 with bracket in cement concrete 1:3:6 (1:cement:3c/sand:6 gr. st. 40 mm n/size) foundation i/c excavation and refilling etc. as requred.
Supply and drawing of AB Cable of size (3x50 + 1x35) mm2
Cross arm 70X40mm/2 wire.
Back clamp for Cross arm 70X40mm
S/F stay set complete with stay wire & stay insulator etc.as reqd.
SH:D1 - Construction of Booking Counter and Office
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sandy soil under floors including,watering,ramming consolidating and dressing complete with a lead of 15 Km
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a) C.C. 1:5:10 (1 cement :5 coarse sand :10 graded stone aggrt. 40mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 Kanhaighat sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc.above plinth up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5kanhaighat sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 kanhaighat sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level.(a) Thermo-Mechanically Treated bars.
Centering and shuttering including strutting, propping etc. and removal of form for:(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, Pillars, Piers, Abutments, Posts and Struts.
(c) Lintels, beams, plinth beams, girders, bressumers and cantilevers,with water proof ply 12mm thick.
(d ) Suspended floors, roofs, landings, balconies and access platform,with water proof ply 12mm thick.
Brick work with Ist class common burnt clay F.P.S. (non modular)bricks in foundation and plinth in: (i) (1 Cem: 4kanhaighat sand)
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in : (i) cement mortar 1:4 (1 cement : 4 kanhaighat sand)
(a) Upto 1st floor level
Brick work with Ist class common burnt clay F.P.S.(non modular)bricks in superstructure above plinth level upto floor V level in all shapes and sizes in :(i) cement mortar 1:4 (1 cement : 4 kanhaighat sand)
Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : (a) Local best quality Teak wood.
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked MS pressed butt hinges bright finished of required sizes with necessary screws..(a) Local best quality Teak wood.(a) 35mm thick.
Providing 40x3mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts, nuts and wooden plugs and embedding to cement concrete block 30x10 x15cm 1:3:6 (1 cement : 3 c/coarse sand : 6 stone aggrt. 20mm nominal size).
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :
Providing and fixing bright finished brass tower bolts (barrel type)with necessary screws etc. complete : (a) 250x10 mm
Providing and fixing bright finished brass handles with screws etc. complete :(a) 125mm
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved brand and manufacture in all colours and shades, laid on 20mm thick cement mortar 1:4(1 cement: 4 c/ sand)jointing with grey cement slurry @3.3 kg/m including grouting the joints with white cement and matching pigments etc., the tiles must be cut wth the zero chipping diomond cutter only. laying of tiles will be done with the notch trowel,plier,wedge,clips of required thickness,levelling system and rubber mallet for placing gently and easily.(a) Double charge vitrified tile polished finish of size(i) Size of Tile 600 x 600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete.(i) Size of Tile 600x600 mm
12 mm cement plaster of mix 1:4 (1 cement : 4 kanhaighat sand).
15mm cement plaster on rough side of single or half brick wall of mix (i) 1:4 (1 cement : 4 Kanaighat coarse sand).
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :.(i) Water thinnable cement primer
Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing walls with Acrylic smooth exterior paint of required shade : (i) New work (Two or more coats applied @ 1.67 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
Applying priming coat :- (a) With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 c/ sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
15 mm cement plaster 1:3 (1 cement: 3 kanhaighat sand) finished with afloating coat of neat cement on the roughside of single or half brick wall.
SH:D2- Providing WS & SI for Booking Counter and Office
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level(a) 1:4:8 (1 cem :4c/ sand:8 graded stone aggrt.40mm n/size).
(b) 1:2:4 (1 cem :2c/sand:4 graded stone aggrt.20mm n/size).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 kanhaighat sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level.(a) Thermo-Mechanically Treated bars.
Centering and shuttering including strutting, propping etc. and removal of form for(a) Suspended floors, roofs, landings, balconies and access platform,with water proof ply 12mm thick.
(b) Edges of slab and breaks in floors and walls (i).Under 20 cm wide.
Brick work with Ist class common burnt clay F.P.S. (non modular)bricks in foundation and plinth in: (i) (1 Cem: 4kanhaighat sand)
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in foundation and plinth : (i) cement mortar 1:4 (1 cement : 4 kanhaighat sand)
12 mm cement plaster of mix 1:4 (1 cement : 4 kanhaighat sand).
15 mm cement plaster 1:3 (1 cement: 3 kanhaighat sand) finished with afloating coat of neat cement on the roughside of single or half brick wall.
P/F C.I. Cover with frame (for manhole and chambers) (i) 600 mm x 450 mm (heavy duty) (38 Kg)
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings &C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting offittings and brackets, cutting and making good the walls andfloors wherever required : (a) W.C. pan with ISI marked white solid plastic seat and lid.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P.brass pillar taps, 32 mm C.P. brass waste of standard pattern,including painting of fittings and brackets, cutting and making good the walls wherever required: (a) White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (a) External Works.
(i) 25 mm nominal outer dia Pipes
(i) 32 mm nominal outer dia Pipes
(i) 80 mm nominal outer dia Pipes
(i) 100 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.(A) Concealed work, including cutting chases and making good the wall (i) 15 mm nominal outer dia Pipes
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :(a) 15 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :(i) 25 mm nominal outer dia Pipes
P/F 125 mm dia grating with waste hole
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 (a) 15 mm nominal bore
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
SH:D3 - Providing IEI in Booking Counter and Office
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with modular type switch , modular Plate suitable size MS-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X1.5mm2+1X1.5mm2 earth wire
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing switch box/cover i/c connection etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
Wiring for submain with 10mm2 pvc ins. Pvc shea . Al cond. s/c cable on GI bearer wire
SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver 15 W 840 LHEAAGP6IA2W012 complete with connection as rqd. (Havell's)
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F 12W LED bulb
S/F fan hook i/c bolt & nuts.
S/F 48"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) bladesetc.as reqd. (Make Bajaj/Usha/Crompton/Orient)
S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc.
Installation of exhaust fan upto 450mm sweep in the existing opening i/c making the hole to suit the size of the above fan, making good the damaged, connection testing commissioning etc. as reqd.
S/F 305mm sweep exhaust fan complete with accessories i/c connection etc. as reqd.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+4 way
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
(a)10 amp MCB "C" Curve
(a)20 amp MCB "C" Curve
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 60 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
P/F 300x400x60mm(n/size) with permissible variation of plus minus 5mm in size wooden board complete with locking arrangement and painting etc.
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
SH:E - Landscapping
Construction of Embankment with Material Obtained from Borrow Pits (Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2)
Grassing with 'Doobs' Grass (Grassing with 'Doobs' grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed)(ii) In rows 7.5 cm apart in either direction
Maintenance of Lawns with Fine Grassing for the First Year including watering etc
SH:F1- Construction of Rain Shelter with sitting benches
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sandy soil under floors including,watering,ramming consolidating and dressing complete with a lead of 15 Km
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a) C.C. 1:5:10 (1 cement :5 coarse sand :10 graded stone aggrt. 40mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 Kanhaighat sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc.above plinth up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5kanhaighat sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 kanhaighat sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level.(a) Thermo-Mechanically Treated bars.
Centering and shuttering including strutting, propping etc. and removal of form for:(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, Pillars, Piers, Abutments, Posts and Struts.
(c) Lintels, beams, plinth beams, girders, bressumers and cantilevers,with water proof ply 12mm thick.
(d ) Suspended floors, roofs, landings, balconies and access platform,with water proof ply 12mm thick.
Brick work with Ist class common burnt clay F.P.S. (non modular)bricks in foundation and plinth in: (i) (1 Cem: 4kanhaighat sand)
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in : (i) cement mortar 1:4 (1 cement : 4 kanhaighat sand)
(a) Upto 1st floor level
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved brand and manufacture in all colours and shades, laid on 20mm thick cement mortar 1:4(1 cement: 4 c/ sand)jointing with grey cement slurry @3.3 kg/m including grouting the joints with white cement and matching pigments etc., the tiles must be cut wth the zero chipping diomond cutter only. laying of tiles will be done with the notch trowel,plier,wedge,clips of required thickness,levelling system and rubber mallet for placing gently and easily.(a) Double charge vitrified tile polished finish of size(i) Size of Tile 600 x 600 mm
12 mm cement plaster of mix 1:4 (1 cement : 4 kanhaighat sand).
15mm cement plaster on rough side of single or half brick wall of mix (i) 1:4 (1 cement : 4 Kanaighat coarse sand).
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :.(i) Water thinnable cement primer
Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing walls with Acrylic smooth exterior paint of required shade : (i) New work (Two or more coats applied @ 1.67 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
15 mm cement plaster 1:3 (1 cement: 3 kanhaighat sand) finished with afloating coat of neat cement on the roughside of single or half brick wall.
SH:F2- Providing IEI in Rain Shelter with sitting benches
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with modular type switch , modular Plate suitable size MS-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group B
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
Wiring for submain with 10mm2 pvc ins. Pvc shea . Al cond. s/c cable on GI bearer wire
SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver 15 W 840 LHEAAGP6IA2W012 complete with connection as rqd. (Havell's)
SITC 50W LED 5000K energy saving IP 65 Flood Light luminaries with high power LED as light source Havell's JETACOMPECTOFL50W LED 757LTG complete with connection as rqd. (Havell's)
S/F fan hook i/c bolt & nuts.
S/F 48"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) bladesetc.as reqd. (Make Bajaj/Usha/Crompton/Orient)
S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 4 ways double door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
(a)10 amp MCB "C" Curve
(a)20 amp MCB "C" Curve
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 300x400x60mm(n/size) with permissible variation of plus minus 5mm in size wooden board complete with locking arrangement and painting etc.
SH:G1- Construction of Public Toilet (Ladies & Gents)
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sandy soil under floors including,watering,ramming consolidating and dressing complete with a lead of 15 Km
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a) C.C. 1:5:10 (1 cement :5 coarse sand :10 graded stone aggrt. 40mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 Kanhaighat sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc.above plinth up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5kanhaighat sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 kanhaighat sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level.(a) Thermo-Mechanically Treated bars.
Centering and shuttering including strutting, propping etc. and removal of form for:(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, Pillars, Piers, Abutments, Posts and Struts.
(c) Lintels, beams, plinth beams, girders, bressumers and cantilevers,with water proof ply 12mm thick.
(d) Suspended floors, roofs, landings, balconies and access platform,with water proof ply 12mm thick.
(e) Edges of slab and breaks in floors and walls (i).Under 20 cm wide.
Brick work with Ist class common burnt clay F.P.S. (non modular)bricks in foundation and plinth in: (i) (1 Cem: 4kanhaighat sand)
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in : (i) cement mortar 1:4 (1 cement : 4 kanhaighat sand)
(a) Upto 1st floor level
Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : (a) Local best quality Teak wood.
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked MS pressed butt hinges bright finished of required sizes with necessary screws..(a) Local best quality Teak wood.(a) 35mm thick.
Providing 40x3mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts, nuts and wooden plugs and embedding to cement concrete block 30x10 x15cm 1:3:6 (1 cement : 3 c/coarse sand : 6 stone aggrt. 20mm nominal size).
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :
Providing and fixing bright finished brass tower bolts (barrel type)with necessary screws etc. complete : (a) 250x10 mm
Providing and fixing bright finished brass handles with screws etc. complete :(a) 125mm
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved brand and manufacture in all colours and shades, laid on 20mm thick cement mortar 1:4(1 cement: 4 c/ sand)jointing with grey cement slurry @3.3 kg/m including grouting the joints with white cement and matching pigments etc., the tiles must be cut wth the zero chipping diomond cutter only. laying of tiles will be done with the notch trowel,plier,wedge,clips of required thickness,levelling system and rubber mallet for placing gently and easily.(a) Double charge vitrified tile polished finish of size(i) Size of Tile 600 x 600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete.(i) Size of Tile 600x600 mm
12 mm cement plaster of mix 1:4 (1 cement : 4 kanhaighat sand).
15mm cement plaster on rough side of single or half brick wall of mix (i) 1:4 (1 cement : 4 Kanaighat coarse sand).
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :.(i) Water thinnable cement primer
Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing walls with Acrylic smooth exterior paint of required shade : (i) New work (Two or more coats applied @ 1.67 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
Applying priming coat :- (a) With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 c/ sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
15 mm cement plaster 1:3 (1 cement: 3 kanhaighat sand) finished with afloating coat of neat cement on the roughside of single or half brick wall.
SH:G2- Providing WS & SI for Public Toilet (Ladies & Gents)
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level(a) 1:4:8 (1 cem :4c/ sand:8 graded stone aggrt.40mm n/size).
(b) 1:2:4 (1 cem :2c/sand:4 graded stone aggrt.20mm n/size).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 kanhaighat sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level.(a) Thermo-Mechanically Treated bars.
Centering and shuttering including strutting, propping etc. and removal of form for(d) Suspended floors, roofs, landings, balconies and access platform,with water proof ply 12mm thick.
(e) Edges of slab and breaks in floors and walls (i).Under 20 cm wide.
Brick work with Ist class common burnt clay F.P.S. (non modular)bricks in foundation and plinth in: (i) (1 Cem: 4kanhaighat sand)
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in foundation and plinth : (i) cement mortar 1:4 (1 cement : 4 kanhaighat sand)
12 mm cement plaster of mix 1:4 (1 cement : 4 kanhaighat sand).
15 mm cement plaster 1:3 (1 cement: 3 kanhaighat sand) finished with afloating coat of neat cement on the roughside of single or half brick wall.
P/F C.I. Cover with frame (for manhole and chambers) (i) 600 mm x 450 mm (heavy duty) (38 Kg)
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings &C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting offittings and brackets, cutting and making good the walls andfloors wherever required : (a) W.C. pan with ISI marked white solid plastic seat and lid.
Providing and fixing white vitreous china flat back or wall cornertype lipped front urinal basin of 430x260x350 mm and340x410x265 mm sizes respectively with utomatic flushingcistern with standard flush pipe and C.P. brass spreaders withbrass unions and G.I clamps complete, including painting offittings and brackets, cutting and making good the walls andfloors wherever required : (a) One urinal basin with 5 litre white P.V.C. automatic flushing cistern
Providing and fixing wash basin with C.I. brackets, 15 mm C.P.brass pillar taps, 32 mm C.P. brass waste of standard pattern,including painting of fittings and brackets, cutting and making good the walls wherever required: (a) White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (a) External Works.
(i) 25 mm nominal outer dia Pipes
(i) 32 mm nominal outer dia Pipes
(i) 80 mm nominal outer dia Pipes
(i) 100 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.(A) Concealed work, including cutting chases and making good the wall (i) 15 mm nominal outer dia Pipes
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :(a) 15 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :(i) 25 mm nominal outer dia Pipes
P/F 125 mm dia grating with waste hole
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 (a) 15 mm nominal bore
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
SH:G3- Providing IEI in Public Toilet (Ladies & Gents)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with modular type switch , modular Plate suitable size MS-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X1.5mm2+1X1.5mm2 earth wire
2X2.5mm2+1X2.5mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing switch box/cover i/c connection etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
Wiring for submain with 10mm2 pvc ins. Pvc shea . Al cond. s/c cable on GI bearer wire
SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver 15 W 840 LHEAAGP6IA2W012 complete with connection as rqd. (Havell's)
S/F fan hook i/c bolt & nuts.
S/F 48"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) bladesetc.as reqd. (Make Bajaj/Usha/Crompton/Orient)
S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc.
Installation of exhaust fan upto 450mm sweep in the existing opening i/c making the hole to suit the size of the above fan, making good the damaged, connection testing commissioning etc. as reqd.
S/F 305mm sweep exhaust fan complete with accessories i/c connection etc. as reqd.
SITC 50W LED 5000K energy saving IP 65 Flood Light luminaries with high power LED as light source Havell's JETACOMPECTOFL50W LED 757LTG complete with connection as rqd. (Havell's)
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+4 way
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
(a)10 amp MCB "C" Curve
(a)20 amp MCB "C" Curve
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 60 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
P/F 300x400x60mm(n/size) with permissible variation of plus minus 5mm in size wooden board complete with locking arrangement and painting etc.
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
SH:H1- Drinking water Facility
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a) 1:4:8 (1 cem :4c/ sand:8 graded stone aggrt.40mm n/size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 Kanhaighat sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc.above plinth up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5kanhaighat sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 kanhaighat sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level.(a) Thermo-Mechanically Treated bars.
Centering and shuttering including strutting, propping etc. and removal of form for:(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, Pillars, Piers, Abutments, Posts and Struts.
(c) Lintels, beams, plinth beams, girders, bressumers and cantilevers,with water proof ply 12mm thick.
(d) Walls (any thickness) including attached pilasters, buttresses,plinth and string courses etc.
(e) Suspended floors, roofs, landings, balconies and access platform,with water proof ply 12mm thick.
(f) Edges of slab and breaks in floors and walls (i).Under 20 cm wide.
Brick work with Ist class common burnt clay F.P.S. (non modular)bricks in foundation and plinth in: (i) (1 Cem: 4kanhaighat sand)
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved brand and manufacture in all colours and shades, laid on 20mm thick cement mortar 1:4(1 cement: 4 c/ sand)jointing with grey cement slurry @3.3 kg/m including grouting the joints with white cement and matching pigments etc., the tiles must be cut wth the zero chipping diomond cutter only. laying of tiles will be done with the notch trowel,plier,wedge,clips of required thickness,levelling system and rubber mallet for placing gently and easily.(a) Double charge vitrified tile polished finish of size(i) Size of Tile 600 x 600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete.(i) Size of Tile 600x600 mm
Providing and fixing M.S. round holding down with nuts and wahser plates completes
Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm)with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trussesand including cutting to size and shape wherever required with (i) Precoated galvanised iron profile sheets 0.50 mm thick
Providing and fixing precoated galvanised steel sheet roofing accessories , Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : (i) Ridges plain (500 - 600mm). (a) Precoated galvanised iron profile sheets 0.50 mm thick.
Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc.complete. (a) Electric resistance or induction butt welded tubes
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :.(i) Water thinnable cement primer
Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing walls with Acrylic smooth exterior paint of required shade : (i) New work (Two or more coats applied @ 1.67 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
SH:H2- Providing W.S. for Drinking water Facility
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (a) External Works.(ii) 32 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.(A) Concealed work, including cutting chases and making good the wall etc.(i) 15 mm nominal outer dia pipes
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :(a) 15 mm nominal bore
SH:I- Construction of Pathway
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a) 1:4:8 (1 cem :4c/ sand:8 graded stone aggrt.40mm n/size).
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4(1 cement: 4 coarse sand).(i) Ordinary cement without any pigment.
SH:J- Solar Lighting
Solar LED street lamp All-In-One with in built SCC system wattage of 30 W of make Crompton Greaves Ltd.code no CSADEMP25/30CDL, 140 Lumen/Watt high efficiency crystaline solar SPV panel.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.00 MB
Documents.pdf
Tender Documents • 25.68 MB
Drawing.pdf
Additional Documents • 10.70 MB
ScheduleOfMaterials.pdf
Additional Documents • 0.68 MB
BOQ_3505.xls
BOQ • 0.50 MB
Download all tender documents and submit your bid