Tender Value
₹23 L
EMD Value
₹50,000
Closing Date
24 Mar 2023, 6:00 pmClosed
GE (I) (CGN) KOLKATA
GE (I) (Coast Guard Navy) Military Engineer Services Damodar Complex Naval Transit Accommodation Hastings, Kolkata 700 023
ROVN OF FABRICATION OF 02 GATES ALONGWITH SENTRY POST, TYRE DEFLACTOR AND ASSOCIATED FITTINGS AT CGRA MANICKTALA UNDER GE (I) (CGN) KOLKATA
2023_MES_582848_1
NIT No 8701/65/2022-23/03/E8
Open Tender
Civil Works
Item Rate
180 days
GE (I) (CGN) KOLKATA
AS PER TENDER DOCUMENT
8 documents required · 8 mandatory
₹500
GE (I) (CGN) Kolkata
₹50,000
Yes
21 Apr 2023
24 Feb 2023
27 Mar 2023
24 Feb 2023
24 Mar 2023
10 Mar 2023
Amount
Demolition of cement concrete(unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level)
Dismantling structural steel work including doors, gates but excluding framed truss etc into primary parts complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed by Engineer in charge.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Material and labour for treating the backfill in contact with foundation at the rate of 7.5 litres of chemical emulsion in water of one percent Chlorpyrifos 20 EC for per square metre of vertical surface complete all as specified and as directed (Area of the sub structure in contact with backfill to be measured).
Material and labour for treating the top surface of filled earth at the rate of 5 litres of chemical emulsion in water of one percent Chlorpyrifos 20 EC for per square metre of surface complete all as specified and as directed.
Material and labour for treating the soil under plinth protection at the rate of 5 litres of chemical emulsion in water of one percent Chlorpyrifos 20 EC for per square metre of surface area complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
Material and labour for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
Material and labour for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed.
Material and labour for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete complete all as specified and as directed.
Material and labour for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified and as directed.
Material and labour .for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified and as directed.
Material and labour for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exceeding 10 cm but not exceeding 20 cm wide for rough finished surfaces of concrete complete all as specified and as directed.
Material and labour for formwork to small surfaces such as cantilever ends, brackets, ends of steps, caps and bases of pilasters and the columns and the like for rough finished surfaces of concrete complete all as specified and as directed.
Material and labour for formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished flat surfaces of concrete complete all as specified and as directed.
Material and labour for RCC M25 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
Material and labour for RCC M25 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in chajjas complete all as specified and as directed.
Material and labour for RCC M25 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and as directed.
Material and labour for RCC M25 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and as directed.
Material and labour for RCC M25 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
Material and labour for RCC M25 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and as directed.
Material and labour hot rolled medium and high tensile structural steel of grade E 250 quality C conforming to IS 2062: 2011 as in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed.
Material and labour hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and directed by Engineer-in-charge.
Material and labour for preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-Charge.
Material and labour for cement concrete in surface channels and drains in M15(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
Material and labour for 40 mm thick damp proof course in cement concrete M15(Nominal mix) using 12.5 mm nominal size graded crushed stone aggregate mixed with integral water proofing compound to horizontal or vertical surfaces including necessary formworks complete all as specified and as directed. Note: - Water proofing compound shall be measured and paid for separately.
Supply only liquid water proofing compound.
Material and labour for brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed.
Material and labour for powder coated, minimum thickness 50 micron, aluminium sections for doors, windows, ventilators, door partition including fabrication of frame shutters and fixing with necessary lugs, cleats, rollers, handles, locking arrangement etc. including all accessories such as glazings clips, and rubber beadings for fixing glass panes in frame complete all as specified. Note : (i) Glass panes, wire mesh & handle will be measured & paid separately . (ii)The quoted rate shall be inclusive of cost of rubber beading however it will be not be weighed and not paid separately. (iii) All other minor details including cost of locking arrangement shall be included in the quoted rate.
Material and labour for powder coated aluminium window and ventilator shutters, fixed type without sash bar, aluminium section (thickness of powder coating not less than 50 micron) weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws etc. complete all as specified and as directed.
Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:6 finished even and fair complete all as specified and as directed.
Material and labour for plastering 20 mm thick (in two coats of 15 mm and 5 mm thick) on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 with integral water proofing compound in external coat, finished even and fair complete all as specified and as directed. Note: - Water proofing compound shall be measured and paid for separately.
Material and labour for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over one coat of alkali resistant primer over putty to match the existing surfaces complete all as specified and as directed
Supply and fixed solid PVC door frames of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube all as per specification & drawing complete all as specified and directed by Engineer in charge.
Supply and fixed factory made solid PVC moulded door shutter, 28 to 30 mm thick (stiles) with particle board core, with 2, 4, or 6 raised panel design with 2 mm thick Moulded PVC Sheet on the front face & 2 mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing.
Supply amnd fixed medium weight stainless steel butt hinges, 100 mm size, naturally finished bright with smooth surface without chemical coating complete all as specified and as directed.
Supply and fixed aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 150 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
Supply and fixed cast aluminium alloy handle, cast type, 150 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
Supply and fixed aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 250 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
Material and labour for hardcore (broken stone or boulders) of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
Material and labour for cement concrete M7.5 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 75 mm thick in sub base for laying tiles, pavings, floorings etc. complete all as specified and as directed.
Material and labour for non skid, rectified, colour ceramic floor tiles 7-8 MM thick and area of each tile exceeding 0.11 SQMM but not exceeding 0.18 SQMM as in floor including 15 mm thick bedding layer in cement mortar (1:6), set and jointed in neat cement slurry and pointed in white or colour cement to match the exsting surface all as specified and directed.
Material and labour for glazed, colour ceramic wall tiles (group B III), 450 mm X 300 mm X 8 mm thick on vertical surfaces including 10 mm thick backing coat in cement mortar (1:4), set and jointed in neat cement slurry and pointed in epoxy mortar to match all as specified and directed.
Material and labour for 12-15 mm thich dholpur stone tile of size 200x 100 mm fixed in verticle surface over 10 mm thick backing layer in cement mortar 1:4 set and jointed in cement slurry and pointed with white or colour cement to match with the exsting complete all as specified and as directed.
Material and labour for preparing new plaster surfaces walls including chajjas, facias etc. and applying two coat of weather proof acrylic exterior paint (100% Acrylic) over a coat of primer including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed.
Material and labour for preparing RCC roof surfaces with wire brush drying and cleaning to remove all foreign materials and washing with water to remove loose particle and providing 20 mm thick cement plaster in CM (1:3) using water proofing compound @ 3 % by weight of cement for filling depression if any to receive water proofing treatment and providing APP modified bituminous membrane water proofing membrane with polyester reinforcement and plain finish of 3 mm thick (not less than 3.0 kg/sqm ± 5% per sqm) consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/Sqm by the same membrane manufacture of density at 25 C, 0.87-0.89 kg/litre and viscosity 70-160 cps over the primer coat the layer of membrane shall be laid using Butane torch application method overlap while torching shall be 75 mm on length and 100 mm width side, all angles & bituminous should sealed with extra care to ensure full bondage all joints including for applying bituminous aluminium paint @ 0.125 Kg / sqm on finished APP surface complete all as specified and as directed by Engineer-In-charge (Note : WPC shall be measured and paid separately)
Material and labour for 20 mm thick granite (zed black) work (table rubbed and polished) for wall lining (veneering to wall) over 12 mm thick cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
Material and labour for stainless steel word of size 250mmx 35 mm with thickness 1.5 mm, and fixing with the screw at any location complete all as specified and as directed.
M&L LED Post top lantern decorative 360 deg indirect light 40 Watt LED made in cast aluminium spigot housing with decorative type opal acrylic diffuser and IP 65 protection including all fitting all as specified and directed.
S & F pole mounted junction box, size 140 mm X 140 mm X 95 mm made of FRP with connector for single phase supply and arrangement to fix MCB SP 6A 10 KA complete all as specified and as directed. Make: Sintex/ Universal
S & F circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 40 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
Supply and fix concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 2.5 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. (Note 1- Two runs of 2.5 sqmm cable, one run of 2.5 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be inclusive in the quoted rate.)
S & F LED industrial lights nominal power 40 Watt LED, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 110 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 65, CRI greater than 80%, CW available CCT of 6500K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with sealed toughened glass cover, life span of minimum 50000 working hours complete all as specified and as directed.
Supply and fixed LED luminious sign board with letter written "INDIAN COAST GUARD RESIDENTIAL ENCLAVE" each letter in 300 mm size on the aluminium composite panel board of size 3.6 M x 1.2 M to be fixed on main gate with all fittings and connected with suitable size of wiring complete all as specified and as directed.
Supply and fixed acrylic LED luminious sign board with "LOGO" each letter written in 300 mm size on aluminium composite panel board of size 3.6 M x 1.2 M to be fixed on main gate with all fittings and connected with wiring all as specified and as directed. Note:- Design of the LOGO shall be provided by department.
S & F sheet metal enclosure with socket plug top and MCB TPN enclosure with three pin & earth plug and socket complete with MCB TPN 32 Amps 415 volts complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 2 core, nominal cross sectional area of main conductor 6 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 10 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, installation, testing and commissioning floor mounted outdoor panel of suitable size. The Panel made out of 3.15 mm thick MS CRCA sheet dust and vermin proof and angle iron structure 50x50x6 mm ,CPRI approved compartmental type of size as required including locking arrangement and 2 coat of powder coated paint over a coat of red oxide metal primer, fixed in floor with MS angle iron 50x50x6mm frame structure and grouted with PCC M-15 (Nominal mix) using 20mm graded stone aggregate with and including separate compartment separated by 3.15 mm CRCA sheet and separate copper bus equal size (1.5 times capacity of incomer) for phase and neutral with porcelain insulator for DG (incomer-1) and Mains Supply (Incomer-2) complete all fittings and fixing arrangement with suitable size FRLS copper wired connection, cable glands for cable entry etc. complete all as specified and as directed having following specifications :- INCOMER-1 (DG supply) (i) 4 Pole MCCB 63 Amps, 16 KA Breaking Capacity with thermal magnetic release- 01
OUTGOING (i) 4 Pole MCCB 40 Amps, 10 KA Breaking Capacity with thermal magnetic release- 02 Nos (ii) 32 A MCB TPN C Series - 03 Nos (iii) 16 Amp MCB DP-02 Nos (iv) Digital Ammeter - 01 No with CTs (v) Digital Voltmeter 0-500 V - 01 No (vi) LED indicator Light - 01 set (3 Nos) INCOMER-2 (Mains supply) (i) 4 Pole MCCB 40 Amps, 10 KA Breaking Capacity with thermal magnetic release- 01 OUTGOING: (i) 32 A MCB TPN C Series - 02 Nos (ii) 16 Amp MCB DP-04 Nos (iii) Digital Time switch - 01 No (iv) Contractor MNX 22-2P - 01 No (v) Digital Ammeter - 01 No with CTs (vi) Digital Voltmeter 0-500 V - 01 No (vii) LED indicator Light - 01 set (3 Nos) Note: Quoted rate is inclusive of necessary PCC foundation
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3.5 core, nominal cross sectional area of main conductor 35 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
M & L for laying of bricks locally available sub class 'B' bricks (old size) for cable protection cover laid flat and dry in trenches over the cablfCe perpendicular to the direction of cable all as directed.
Supplying & fixing to walls and ceilings or laid in floors 50 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
DIPAK ENTERPRISE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .