| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹8.4 LAdmitted-Finance | -15.00% | ₹8.4 L | L1 | Admitted-Finance |
| 2 | L2₹8.9 LAdmitted-Finance A 23 KUNJ VIHAR SOCIETY SHREE KRISHNA NAGAR SAKINAKA ANDHERI E MUMBAI 400 072 | MUMBAI | MUMBAI | MAHARASHTRA | 400072 | -10.10% | ₹8.9 L | L2 | Admitted-Finance |
| 3 | L3₹9.0 LAdmitted-Finance | -9.35% | ₹9.0 L | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | - | Rejected-Technical not eligible |
| 5 | Rejected-Technical | - | - | - | Rejected-Technical not eligible |
Tender Value
₹9.9 L
EMD Value
₹19,766
Closing Date
19 Feb 2026, 1:00 pmClosed
Executive Engineer
12, Cavalry Lane, Engineering Department, University of Delhi, Delhi-110007
Renovation of internal electrical infrastructure in 32 Nos. toilets, electrical rooms at Faculty of social science and faculty of Mathematical Science at University of Delhi
2026_DU_897144_1
CEET-7304
Open Tender
Electrical Works
30 days
North Campus
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
Registrar, University of Delhi
₹19,766
13 Mar 2026
5 Feb 2026
20 Feb 2026
5 Feb 2026
19 Feb 2026
5 Feb 2026
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required.
3 x 1.5 sq.mm
3 x 2.5 sq.mm
3 x 4 sq.mm
3 x 6 sq.mm
Supplying and fixing following size/modules GI box along with modular base and cover plate for modular switches in recess etc as reqd
3 Module (100mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
12 Module (200mmX150mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required
5/6 amps switch
3 pin 5/6 amps socket outlet
15 /16 amps switch
6 pin 15/16 amp socket outlet
Supplying and fixing suitable size G.I. box with modular plate and cover in front or in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB "C" curve including connections, painting etc. as required.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit including dismantling as required.
Group C
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required
Group C
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
S/F of 25mm x5 mm G.I strip on surface or in recess i/c making connection as reqd
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Supplying and fixing of Heavy duty PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required
25 mm dia
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way (4 + 24), Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way , Double Door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of single pole MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required
Single pole
Double pole
Three pole and neutral
Supplying and fixing 2 module stepped type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as reqd.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a ensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
4x16 sqmm+ 2x6 sqmm
Supply, Installation, testing and commissioning of pre-wired, single box fitting with one no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm complete i/c all accessories etc. directly on ceiling/wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. fitting equivalent to Philips Make, Cat No. TMC 502 1xT-LED 22W, Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100lm
Supply, Installation, testing and commissioning of pre-wired, double box type fitting with two no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm complete i/c all accessories etc. directly on ceiling/wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. fitting equivalent to Philips Make, Cat No. TMC 502 2xT-LED 22W, Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100lm
SITC of 12 inch heavy duty, AC, single phase 230 Volt,50 HZ, 1350 RPM, steel body exhaust fan in existing opening,i/c making good the damage, cable connectionetc etc. as reqd
Supplying and Fixing of snap-on DLP trunking of size 105mm x 50 mm with cover and including accessories such as cover, Flat angle, end caps, internal/external angle support etc. on the wall/surface complete all as requied.
Supply, Installation, testing and commissioning of pre-wired, 150 watt, flood light Pressure die-cast aluminium housing with high impact resistance (IK07) glass cover IP66 protection, 130lm/w, 220-240 V, 50 Hz on existig street light pole/wall including all accessories and connection etc.as required..Philips Make, Cat No. BVP 192 LED 177 CW NB FG A1 PSU GR or equivalent model of Thorn/Trilux
Supply and fixing of street light pole box of size (250 X 200 X 100) complete with all necessary accessories including suitable clamps, bakelite sheet, brass screws, washers, and 01 no. 10 Amps SP MCB (Single Pole Miniature Circuit Breaker), inclusive of making electrical connections, as required at site.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.50 MB
BOQ_942999.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid