Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.9 LAccepted-AOC 4 94D RAJA COTTAGE 1ST FLOOR KANYAKULAM PARVATHIPURAM NAGERCOIL KANNIYAKUMARI TAMILNADU 629 003 | KANNIYAKUMARI | TAMIL NADU | 629003 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹59.1 L+₹13.0 L (28.3%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹75.3 L+₹29.3 L (63.5%)Rejected-Finance 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | L3 | Rejected-Finance Not being L1 | |
| 4 | Rejected-Technical | - | Rejected-Technical Being not eligible Due to not uploaded scaned copy of DD |
| Sl No | Description | Qty | Unit | Lucky Enterprises L3 | devan enterprises L2 | ADR ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil complete all as specified and as directed. | 133.65 | CUM | 480 ₹64,152 | 430 ₹57,469.5 | 280 ₹37,422 Lowest |
| 2.00 | Returning filling in excavated soil upto a depth of 30 cm after riddling of excavated soil (in lieu of sand) for cushioning of cable and refilling of trenches with left over normal excavated soil including spreading, leveling, watering and well ramming in layers complete all as specified and directed. | 116.05 | CUM | 140 ₹16,247 | 150 ₹17,407.5 | 80 ₹9,284 Lowest |
| 3.00 | Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. | 17.6 | CUM | 250 ₹4,400 | 250 ₹4,400 | 80 ₹1,408 Lowest |
| 4.00 | Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1 flat of size 300mm x 180mm x 40mm complete all as specified and directed.. | 2,178 | EACH | 48 ₹1,04,544 | 44 ₹95,832 | 36 ₹78,408 Lowest |
| 5.00 | Material and labour for Boring of holes under roof, pavement, hardstanding by trenchless technology using ultrasound technique and necessary machine including HDPE pipe of 75mm dia suitable for 0.4mpa working pressure all as pecified and directed. | 50 | RM | 2,800 ₹1,40,000 | 1,700 ₹85,000 | 1,200 ₹60,000 Lowest |
| 6.00 | Supply, Lay, testing and commissioning of HT UG cable XLPE insulated , screened, PVC bedded, galvanized steel strip or wire armored electric power cable (heavy duty earthed) with stranded aluminium conductor, 11000 volts grade of size 3 core 95 Sqmm complete laid in trenches or fixed on walls /floors etc.all as specified and as directed. | 150 | RM | 1,380 ₹2,07,000 | 1,300 ₹1,95,000 | 1,180 ₹1,77,000 Lowest |
| 7.00 | Supply, Lay, testing and commissioning of HT UG cable XLPE insulated , screened, PVC bedded, galvanized steel strip or wire armored electric power cable (heavy duty earthed) with stranded aluminium conductor, 11000 volts grade of size 3 core 120 Sqmm complete laid in trenches or fixed on walls /floors etc.all as specified and as directed. | 150 | RM | 1,540 ₹2,31,000 | 1,530 ₹2,29,500 | 1,380 ₹2,07,000 Lowest |
| 8.00 | Supply, Lay, testing and commissioning of HT UG cable XLPE insulated , screened, PVC bedded, galvanized steel strip or wire armored electric power cable (heavy duty earthed) with stranded aluminium conductor, 11000 volts grade of size 3 core 240 Sqmm complete laid in trenches or fixed on walls /floors etc.all as specified and as directed. | 140 | RM | 2,860 ₹4,00,400 | 2,640 ₹3,69,600 | 2,360 ₹3,30,400 Lowest |
| 9.00 | Supply, Lay, testing and commissioning of HT UG cable XLPE insulated , screened, PVC bedded, galvanized steel strip or wire armored electric power cable (heavy duty earthed) with stranded aluminium conductor, 11000 volts grade of size 3 core 150 Sqmm complete laid in trenches or fixed on walls /floors etc.all as specified and as directed. | 110 | RM | 1,980 ₹2,17,800 | 1,750 ₹1,92,500 | 1,590 ₹1,74,900 Lowest |
| 10.00 | Material and labour for fault finding of HT 11 KV 3 core, XLPE cable of size 95/120/185 sqmm by thumping and echo instrument/ computer aided fault finding kit, and finding out exact location of the fault complete all as specified and directed .
Note :(i) Necessary excavavation, reterning refilling and removal of soil shall be measured and paid separately under relevant items of the schedule. | 12 | EACH JOB | 25,000 ₹3,00,000 | 19,500 ₹2,34,000 Lowest | 23,000 ₹2,76,000 |
Tender Value
₹72.0 L
EMD Value
₹1.3 L
Closing Date
23 Jun 2026, 6:00 pmClosed
Ranjeet Kumar, IDSE, CWE
Commander Works Engineers AF South Gangamma Circle Opp Guard Room 410 AFS Jalahalli Bangalore 560013
REPAIRS / MAINTENANCE OF H T NETWORK, RING MAIN UNITS,DEHYDRATION OF TRANSFORMERS, SERVO STABILIZER ISOLATION TRANSFORMER AND ASSOCIATED NETWORK AT AFS YLAHANKA
2026_MES_768111_1
86239/E8
Open Tender
Civil Works
Item Rate
270 days
GE AF elahanka
As per Tender Document
8 documents required · 8 mandatory
₹1,000
GE (AF) Yelahanka
₹1.3 L
Yes
13 Aug 2026
27 May 2026
1 Jul 2026
27 May 2026
23 Jun 2026
17 Jun 2026
27 May 2026 - 2 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil complete all as specified and as directed. | 133.65 | CUM | 16 | ₹2,138.4 |
| 2 | Returning filling in excavated soil upto a depth of 30 cm after riddling of excavated soil (in lieu of sand) for cushioning of cable and refilling of trenches with left over normal excavated soil including spreading, leveling, watering and well ramming in layers complete all as specified and directed. | 116.05 | CUM | 16 | ₹1,856.8 |
| 3 | Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. | 17.6 | CUM | 16 | ₹281.6 |
| 4 | Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1 flat of size 300mm x 180mm x 40mm complete all as specified and directed.. | 2,178 | EACH | 16 | ₹34,848 |
| 5 | Material and labour for Boring of holes under roof, pavement, hardstanding by trenchless technology using ultrasound technique and necessary machine including HDPE pipe of 75mm dia suitable for 0.4mpa working pressure all as pecified and directed. | 50 | RM | 16 | ₹800 |
| 6 | Supply, Lay, testing and commissioning of HT UG cable XLPE insulated , screened, PVC bedded, galvanized steel strip or wire armored electric power cable (heavy duty earthed) with stranded aluminium conductor, 11000 volts grade of size 3 core 95 Sqmm complete laid in trenches or fixed on walls /floors etc.all as specified and as directed. | 150 | RM | 16 | ₹2,400 |
| 7 | Supply, Lay, testing and commissioning of HT UG cable XLPE insulated , screened, PVC bedded, galvanized steel strip or wire armored electric power cable (heavy duty earthed) with stranded aluminium conductor, 11000 volts grade of size 3 core 120 Sqmm complete laid in trenches or fixed on walls /floors etc.all as specified and as directed. | 150 | RM | 16 | ₹2,400 |
| 8 | Supply, Lay, testing and commissioning of HT UG cable XLPE insulated , screened, PVC bedded, galvanized steel strip or wire armored electric power cable (heavy duty earthed) with stranded aluminium conductor, 11000 volts grade of size 3 core 240 Sqmm complete laid in trenches or fixed on walls /floors etc.all as specified and as directed. | 140 | RM | 16 | ₹2,240 |
| 9 | Supply, Lay, testing and commissioning of HT UG cable XLPE insulated , screened, PVC bedded, galvanized steel strip or wire armored electric power cable (heavy duty earthed) with stranded aluminium conductor, 11000 volts grade of size 3 core 150 Sqmm complete laid in trenches or fixed on walls /floors etc.all as specified and as directed. | 110 | RM | 16 | ₹1,760 |
| 10 | Material and labour for fault finding of HT 11 KV 3 core, XLPE cable of size 95/120/185 sqmm by thumping and echo instrument/ computer aided fault finding kit, and finding out exact location of the fault complete all as specified and directed .
Note :(i) Necessary excavavation, reterning refilling and removal of soil shall be measured and paid separately under relevant items of the schedule. | 12 | EACH JOB | 16 | ₹192 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.46 MB
86239Tender.pdf
Tender Documents • 2.84 MB
BOQ_860185.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .