Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.4 CrAdmitted-Finance | ₹5.4 Cr | L1 | Admitted-Finance |
| 2 | Rejected-Technical | - | - | Rejected-Technical Technically Non Responsive |
| 3 | Rejected-Technical | - | - | Rejected-Technical Technically Non Responsive |
| Sl No | Description | Qty | Unit | M P KHAITAN L1 |
|---|---|---|---|---|
| 1.00BOTANICAL GARDEN : Civil & Allied Works | ||||
| 1.00EARTH WORKS | ||||
| 1.00 | Clearing compound premises of shurbs, plants, jungles etc. by cutting and removing as directed (Specific
permission of Engineer-in-Charge prior to execution will be necessary). (Payment to be made on area cleared) | 944 | sqm | 10 ₹9,440 |
| 1.00 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but
excluding laterite or sandstone) including removing,spreading or stacking the spoils within a lead of 75 m.as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the
bottom, bailing out water as required complete.
(a) Depth of excavation not exceeding 1,500 mm. | 909 | cum | 200 ₹1.8 L |
| 1.00 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing,spreading or stacking the spoils within a lead of 75 m.as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.
b) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring
shoring. | 713 | cum | 300 ₹2.1 L |
| 1.00 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing,spreading or stacking the spoils within a lead of 75 m.as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.
(c) Depth of excavation for additional depth beyond 3000 mm. upto 4000mm. excluding cost of shoring as
necessary | 13 | cum | 600 ₹7,800 |
| 1.01 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm.including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)
(a) With earth obtained from excavation of foundation. | 218 | cum | 110 ₹23,980 |
| 1.01 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)
(iii) With carried earth arranged by the contractor within a radius exceeding 3 km. but not exceeding 5 km including the cost of carried earth. | 1,292 | cum | 900 ₹11.6 L |
| 1.01 | Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating
the same by thorough saturation with water, ramming complete including the cost of supply of sand.
(payment to be made on measurement of finished quantity) | 966 | cum | 1,500 ₹14.5 L |
| 1.01 | Hire and labour charges for shoring work (including necessary close plank walling, framing, Eucalyptus/Jhou
bulla piling, strutting etc) complete as per direction of the Engineer-in-charge for foundation excavation (vertical surface are in contact with supported earth is to be measured.) (This item should be executed on specific direction of the Enginner in charge).
(a) Depth upto 1.5 m. | 327 | Sqm | 3,800 ₹12.4 L |
Tender Value
₹5.5 Cr
EMD Value
₹11.0 L
Closing Date
14 Jan 2026, 3:00 pmClosed
Project Director
Office of WBTIDCLtd. C.S.T.C. Kasba Depot Compound Kolkata-700107
Design, Structural Vetting and Construction of Search and Rescue Centres and Command and Control Centre Sl 05
2025_WBTID_977263_5
IN-WBTIDCL-529368-CW-RFB
Open Tender
Miscellaneous Works
300 days
Kolkata
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹11.0 L
Office of WBTIDCLtd
6 Mar 2026
23 Dec 2025
14 Jan 2026
23 Dec 2025
14 Jan 2026
6 Jan 2026
30 Dec 2025
BOTANICAL GARDEN : Civil & Allied Works
EARTH WORKS
Clearing compound premises of shurbs, plants, jungles etc. by cutting and removing as directed (Specific permission of Engineer-in-Charge prior to execution will be necessary). (Payment to be made on area cleared)
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing,spreading or stacking the spoils within a lead of 75 m.as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm.
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing,spreading or stacking the spoils within a lead of 75 m.as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. b) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring.
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing,spreading or stacking the spoils within a lead of 75 m.as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (c) Depth of excavation for additional depth beyond 3000 mm. upto 4000mm. excluding cost of shoring as necessary
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm.including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation.
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (iii) With carried earth arranged by the contractor within a radius exceeding 3 km. but not exceeding 5 km including the cost of carried earth.
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
Hire and labour charges for shoring work (including necessary close plank walling, framing, Eucalyptus/Jhou bulla piling, strutting etc) complete as per direction of the Engineer-in-charge for foundation excavation (vertical surface are in contact with supported earth is to be measured.) (This item should be executed on specific direction of the Enginner in charge). (a) Depth upto 1.5 m.
Hire and labour charges for shoring work (including necessary close plank walling, framing, Eucalyptus/Jhou bulla piling, strutting etc) complete as per direction of the Engineer-in-charge for foundation excavation (vertical surface are in contact with supported earth is to be measured.) (This item should be executed on specific direction of the Enginner in charge). (b) For additional depth beyond 1.5 m. and upto 3.00 m
Hire and labour charges for shoring work (including necessary close plank walling, framing, Eucalyptus/Jhou bulla piling, strutting etc) complete as per direction of the Engineer-in-charge for foundation excavation (vertical surface are in contact with supported earth is to be measured.) (This item should be executed on specific direction of the Enginner in charge). (c) For additional depth beyond 3.00 m.
Bailing or pumping out water from foundation trenches
40 mm. thick damp proof course with cement concrete (1:1.5:3) (with graded stone chips 20 mm nominal size) with water proofing compound of approved brand @ 0.2% weight of cement including cost of materials over two coats of non toxic acrylic polymer modified cementitious waterproofing slurry coat complete [cost of water proofing compound and non toxic paint to be paid seperately) for underground water retaining structures. [water proofing as per item no 9 and non toxic paint as per item no. 8 (b) of subhead C of Section 'C' ]
Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties by mixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer's specification for water proofing layer in water tank etc. (No Departmental Cement is required)
Extra rate for using water proofing and plasticising admixture @ 0.2% by weight of cement (or at manufacturer's specified rate) for concrete of various grades
(c) Anti termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. of the surface before sand bed or sub-grade is laid. Holes upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways shall be made with 12 mm, diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in para 6.4 of code IS-6313 (part -II) 1981. ( Mode of measurment will be per Sq.m of plan area of plinth treated.)
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal /Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge
CONCRETE WORK
Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor (a) Pakur variety (b) 1:4:8 proportion
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. (a) Pakur variety
Cement concrete with graded stone ballast (40 mm size excluding shuttering) (a) Pakur variety (b) 1:3:6 proportion
RCC WORK
Supplying ready mixed concrete of M 30 Grade with well graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu.m of wet concrete produced in computerised batching plant under controlled condition using approved super plastisizer, designing concrete mix following I.S. 10262 and I.S. 456, transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required levels of concreting and then placing the mix in its final location of form work, compacting and curing the same complete as per specification & direction of the Engineer-in-charge including computerised batching plant transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. [cement to be supplied by the Manufacturer/ supplier] In ground floor and foundation (ii) With approved concrete pump
Supplying ready mixed concrete of M 30 Grade with well graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu.m of wet concrete produced in computerised batching plant under controlled condition using approved super plastisizer, designing concrete mix following I.S. 10262 and I.S. 456, transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required levels of concreting and then placing the mix in its final location of form work, compacting and curing the same complete as per specification & direction of the Engineer-in-charge including computerised batching plant transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. [cement to be supplied by the Manufacturer/ supplier] upto 4 th floor.
Add extra over the rate of ground floor for basement and each additional floor above ground floor
R.C. shelves (1:1.5:3) either precast or cast in situ with stone chips and necessary reinforcement upto 1% (0.8% main and 0.2% distribution bars),shuttering etc. and 10 mm. thick cement plaster (1:4) including neat cement finishing and cutting chase fitting and fixing in position, mending good damages as necessary complete.In ground floor 50 mm thick using steel of I. SAIL/ TATA/RINL
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/mild steel I. SAIL/ TATA/RINL
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. I. SAIL/ TATA/RINL First Floor
Add extra over the rate of ground floor/initial 4 m for each basement floor and each additional floor below/ above ground floor upto 4th floor
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns,lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns,lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (ii) First Floor
Extra for works beyond the roof of ground floor per additional floor (i) upto 4th (per floor) and in basement.]
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (iii) Second Floor
Extra for works beyond the roof of ground floor per additional floor (i) upto 4th (per floor) and in basement
Extra for works beyond the roof of ground floor per additional floor (i) upto 4th (per floor) and in basement
MASONRY WORK
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) -Cement mortar 1:6 (1 cement : 6 coarse sand
Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth
Brick work with 1st class bricks in cement mortar (1:6) (b) In superstructure, Ground Floor
Brick work with 1st class bricks in cement mortar (1:6) (b) In superstructure, Ground Floor
Add extra for basement and each additional floor over the rate for ground floor
Brick work with 1st class bricks in cement mortar (1:6) (b) In superstructure, Second Floor
Add extra for basement and each additional floor over the rate for ground floor upto First Floor
Add extra for basement and each additional floor over the rate for ground floor upto Second Floor
100 mm. thick brick work with 1st class Modular bricks set in cement sand mortar (1:4) including raking out joints, curing, scaffolding etc. complete in all respect with H.B. netting in every third layer in ground floor. in ground floor
100 mm. thick brick work with 1st class Modular bricks set in cement sand mortar (1:4) including raking out joints, curing, scaffolding etc. complete in all respect with H.B. netting in every third layer in ground floor. (a) upto 4th floor - First Floor
Add extra for each additional floor over the rate for ground floor upto 4th Floor
100 mm. thick brick work with 1st class Modular bricks set in cement sand mortar (1:4) including raking out joints, curing, scaffolding etc. complete in all respect with H.B. netting in every third layer in ground floor. (a) upto 4th floor - Second Floor
Add extra for each additional floor over the rate for ground floor upto 4th Floor
Add extra for each additional floor over the rate for ground floor upto 4th Floor
STEEL WORK
M.S. round or square bar grating of windows etc. fitted and fixed in holes of window frame and with intermediate flat bar stiffener( with necessary holes for the grating bars and with the ends turned and fixed to timber frame with necessary screws) complete, as directed. In ground floor.
M.S. round or square bar grating of windows etc. fitted and fixed in holes of window frame and with intermediate flat bar stiffener( with necessary holes for the grating bars and with the ends turned and fixed to timber frame with necessary screws) complete, as directed. In First floor.
Extra 1%for each additional floor upto 4th floor - upto First Floor
M.S. round or square bar grating of windows etc. fitted and fixed in holes of window frame and with intermediate flat bar stiffener( with necessary holes for the grating bars and with the ends turned and fixed to timber frame with necessary screws) complete, as directed. In Second Floor
Extra 1%for each additional floor upto 4th floor - upto First Floor
Extra 1%for each additional floor upto 4th floor - upto Second Floor
Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge. Weight of Strainless Steel railing per metre 6.5 Kg (approx)
M.S. gate of Jail type as per approved design made of strong M.S.frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge. In ground floor
Holding down bolt with nut including 100 x 100 x 6 mm plate washer at bottom fitted complete and packing the hole with cement concrete or cement grout as directed. (i) 16 mm dia bolt (b)450 mm long
JOINERY WORKS
Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868- 1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. Natural white For 2-Track window : Members for Bottom frame @ 0.875 Kg per Mtr.and for Top and Side frame @ 0.778 Kg per Mtr. and for shutter Bottom and Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr. For 3-Track window : Members for Bottom frame @ 1.233 Kg per Mtr.and for Top and Side frame @ 1.067 Kg per Mtr. and for shutter Bottom and Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr.
Supplying, fitting & fixing of Aluminium fixed partion wall of all aluminium sections viz top, bottom and side member, intermediate member, glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733- 1983 and IS: 1285-1975, annodized conforming to IS:1868-1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium fixed partition wall with glass / panel board all complete as per architectural drawings and direction of Engineer-incharge. (Excluding cost of glass/ panel board,10-12 Micron thickness Annodizing film.Natural white.unit wt of Top, bottom & side member @ 1.978; intermediate member @ 2.055; glazing clip @ 0.167 kg/m respectively) b) For unsupported length of vertical member above 1.50m. height of both ends of vertical member restrained but panel above 0.90 sqm -Fixed glazing
Partly glazed partly panelled or fully glazed single leaf alunminium swing door made of extruded and annodized alloy aluminium sections,fabrication including cutting to proper shape and size, drilling and floor with mending damages,with top pin assembly of approve make and brand, fitted with in built locking arrangement, flush bolt, glazing clips and all other necessary fittings, fixtures, adhesives and joineries, cutting glass of approved make to requisite shape and size fitting with dry set neoprene or EPDM gasketing, cutting to requisite shape and size panel board (prelaminated particle block) fixing them with glazing clips as per drawing, specification and direction of Engineer in charge
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. i) 4mm thick coloured / tinted / smoke glass.
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. ii) 6mm thick clear glass.
b) Supplying 'Godrej' mortice lock chromium plated with keys 6 levers including fitting & fixing complete.
Supplying concealed type heavy duty PVC headed aluminium tower bolt for double leaf doors as per approved make and brand as per direction of Engineer-in-Charge. 200 mm long
Hydraulic door closer of approved quality as per I.S.I. standard fitted and fixed complete (a) Heavy type (I.S.I. size 3)
(i) Door stopper.(Brass)
Anodised aluminium decorative handle (hexagonal / fluted) of approed quality fitted and fixed complete. - (ii) 175mm plate x 12mm dia rod x 60mm hexagonal / fluted.
Supplying fitting & fixing frames for Fire resistant door shutters made of 1st class Malaysian Hardwood (densified to 810 kg/cum) and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 psi pressure as per IS:401 and kiln seasoned to moisture below 15% as per IS:1141 of section 120 mm X 70 mm spray quoted with 2 coats of intumescent paint of minimum 200 micron, with single row of Brush- Type intumescent strip of size 10 mmx 4 mm affixed in the slit of the Frame for fire and smoke sealing, etc. complete as per direction of Engineer -in Charge including a protective coat of painting at the contact surfaces of the frame excluding cost of concrete,Iron butt hinges and M.S clamp at Ground Floor. [Note : Specific permission of the Superintending Engineer is required for execution of this item]
Supplying & fitting of 55mm thick asbestos free - fire, heat and smoke resistant composite Fire check Door Shutter complying with fire performance-FD120 as per IS:3614 (part -II)-comprising of 2x8 mm Calcium Silicate boards over Chemically treated (with Fire retardant chemicals in pressure impregnation vessels under 160 psi pressure as per IS:401 and kiln seasoned to moisture below 15% as per IS:1141) internal timber (Malaysian Hard Wood, densified to 810 kg/cum ) frame work of 100 mm x32 mm with 32mm thick infill of ceramic fiber (density 128Kg/cum), vermaculite mix faced with 3 mm Fire retardant High Density fire board, internally lipped with hardwood beading, and pasted in Hydraulic Press under 25 MPa, spray coated with 2 coats of in-tumescent paint of minimum 300 micron, and with single row of Brush- Type intumescent strip of size 10 mm x 4 mm affixed on peripheral slit on all edges of shutter except bottom for fire and smoke sealing , without any external lipping including fitting ,fixing shutters in position but excluding the cost of hinges & other fittings as per direction of Engineer -in -charge complete in all respect in Ground Floor. [Note : Specific permission of the Superintending Engineer is required for execution of this item. ]
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). (a) 1st class Best Indian teak.
Supplying solid flush type doors of deluxe decorative (both side) quality,conforming to I:S 2202 timber frame consisting of top and bottom rail and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 27.5mm wide battens places both ways in order to made the door of solid core and internal lipping with teak, mahogony or rose wood approved decorative veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing the shutters in position but excluding the cost of hinges and other fittings in ground floor: (a) 35mm thick shutters (single leaf)
Supplying solid flush type doors of deluxe decorative (both side) quality,conforming to I:S 2202 timber frame consisting of top and bottom rail and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 27.5mm wide battens places both ways in order to made the door of solid core and internal lipping with teak, mahogony or rose wood approved decorative veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing the shutters in position but excluding the cost of hinges and other fittings in ground floor: ii) First Floor
Add extra over rate of ground floor for each addl. Storey (a) up to 4th floor
Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria.. Mtr 35.00 497.00 17,395.00 (i)66mm x 90mm
Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. - In ground floor (i) 32 mm thick
Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. - In ground floor ii) First Floor
Add extra over rate of ground floor for each addl. Storey up to 4th floor]
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Supplying, fitting and fixing steel rolling shutter grills link type, with 18 B.G . of approved type steel latche section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete.
FLOORING WORK
Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contrr]e) (I)With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment. (A) Deep Colour & White
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (c) Floor With Polymerised Adhesive and Epoxy grout pointing including spacer- 2 mm ( When Tiles are laid over existing hard ready surface) (b) Area of each tile above 0.09 Sq.m [using adhesive 4.5 mm thick] (i) Coloured decorative
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (D)Wall with Polymerised Adhesive and Epoxy grout pointing including spacer- 2 mm ( When Tiles are laid over existing hard ready surface) (b)Area of each tile above 0.09 Sq.m [using adhesive 4.5 mm thick] (i) Coloured decorative
Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20 mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours,curing and roughening of concrete surface complete. In ground floor (b) Area of each Granite slab above 1.0 Square meter.
Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20 mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours,curing and roughening of concrete surface complete. In ground floor (b) Area of each Granite slab above 1.0 Square meter. I) First floor
extra for each addl, floor upto 4 th floor
Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns,wall, facia,rise etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging, curing and roughening of concrete surface complete.[Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m] - In ground floor (a) Area of each Granite slab 0.6 to 1.0 Square meter.
Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns,wall, facia,rise etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging, curing and roughening of concrete surface complete.[Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m] - In ground floor (a) Area of each Granite slab 0.6 to 1.0 Square meter. I) First floor-
extra for each addl, floor upto 4 th floor
Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/granite work including providing necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete as directed by the Engineer-in-Charge at all levels.
Cement concrete flooring with high performance non-metallic floor hardener containing specially graded non-metallic hard wearing natural aggregates imparting floor hardness in the range of mohr scale 8-9 & capable of achieving 28 days compressive strength of 25 MPa with air content less than 3% applied as a dry shake @ 5Kg/sgm sprinkled to provide durable, non-slip monolithic floor for application of the topping over freshly laid concrete with under layer of 40 mm. thick cement concrete (1:2:4) (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) as per specification of the manufacturer & as per direction of Engineer-in-Charge. [Note: Floor hardener is applied as dry shake using a power trowel when the floor concrete has stiffened sufficiently and bleed of water should not be visible on the top of the floor while the application started]
20 mm. thick (finished) terrazo work with precast tiles set on 20 mm avg thick cement mortar (1:3) and sides with admixture of pigment and white/grey cement as necessary in floor, dado, skirting, staircase etc. laid in panels or in patterns including high polishing, raking out joints,roughening of concrete surface & application of cement slurry before flooring works using cement @ 1.75 kg. per sq.m. all complete including all materials & labour. (Add extra @ 1.5 % for each additional floor upto 4th floor and @ 1.75 % for each additional floor above 4th floor). (B) 12 mm. thick terrazo topping, laying and finished to 9 mm. thick after final grinding with 0 to 10 mm. size mosaic chips (i) In ordinary grey colour In ground floor
FALSECEILING WORKS
Supplying fitting & fixing concealed False ceiling Framework with G.I. Section (perimeter channels having one flange of 20 mm. and another flange of 30 mm.with thickness of 0.55 mm. and web of length 27 mm., along the perimeter of the ceiling, screws fixed to the wall with help of nylon sleeves or PVC dash fastners @ 610 mm c/c. then suspend G.I. intermidiate 'C' section with web 90 mm. and flanges of 15 mm. each from soffit @ 1200 mm c/c with ceiling angle of size 25mm. X 10 mm. X 0.55 mm. fixed to soffit G.I. Cleat and Steel expansion fasteners.Ceiling section of 0.55 mm. thickness having web of 51.5 mm. and two flanges of 26 mm. each with lips of 10.55 mm., are then fixed on to the intermediate channel with the help of connecting clips in the direction perpendicular to the intermidiate channel @ 610 mm c/c) with fully threaded fiber cement screws @ 300 mm c/c.all complete as per the drawing and direction of Engineer-in- Charge.Section specification :- Perimeter Channel :- 30 mm X 20 mm X 27 mm,thickness 0.55 mm (min), Intermidiate Channel :- 15 mm X 90 mm, thickness 0.90 mm (min), Ceiling Section :- 51.5 mm X 26 mm X 10.55 mm, thickness 0.55 mm (min), Ceiling Angle :- 25 mm X 10 mm, thickness 0.55 mm (min).
(d) Supplying, fitting & fixing OW Acoustic Board (mineral Fibre Acoustic Ceiling Tiles) of approved patern and size595mm X595mm with NRC value > 0.65 should be placed in the Grid module to form a false ceiling all complete as per drawing & direction of Engineer - in- Charge. False ceiling with (i)15mm thick OW Acoustic Board/Tiles.
FINISHING WORKS
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course,scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (iii) With 1:3 cement mortar (c) 10 mm thick plaster Ground Floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (iii)With 1:3 cement mortar First Floor
Extra for each additional floor over the rate for ground floor up to 4th floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (iii)With 1:3 cement mortar Second Floor
Extra for each additional floor over the rate for ground floor up to 4th floor ]
Extra for each additional floor over the rate for ground floor up to 4th floor ]
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor). [Excluding cost of chipping over concrete surface] With 1:6 cement mortar, 15 mm thick plaster Ground Floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] With 1:6 cement mortar, 15 mm thick plaster First Floor
Extra for each additional floor over the rate for ground floor (a) upt ot 4 th floor]
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] With 1:6 cement mortar, 15 mm thick plaster Second Floor
Extra for each additional floor over the rate for ground floor upt ot 4 th floor]
Extra for each additional floor over the rate for ground floor upt ot 4 th floor]
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. - i) Water based interior grade Acrylic Primer (b) ( two coats) In Ground Floor
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. - i) Water based interior grade Acrylic Primer (b) ( two coats) In First Floor
Extra for each additional floor over the rate for ground floor (i) Upto 4 th floor
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. - i) Water based interior grade Acrylic Primer (b) ( two coats) In Second Floor
Extra for each additional floor over the rate for ground floor (i) Upto 4 th floor
Extra for each additional floor over the rate for ground floor (i) Upto 4 th floor
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) (i) Standard quality In All Floor
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly,EIC (b) Two Coats - In Ground Floor
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly,EIC (b) Two Coats In First Floor
Extra for each additional floor in external walls
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly,EIC (b) Two Coats In Second Floor
Extra for each additional floor in external walls upto 4th floor
Extra for each additional floor in external walls upto 4th floor
protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. a) Normal Acrylic Emulsion - (Two Coat) In Ground Floor
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. a) Normal Acrylic Emulsion - (Two Coat) In First Floor
Extra for each additional floor in external walls upto 4th floor
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. a) Normal Acrylic Emulsion - (Two Coat) In Second Floor
Extra for each additional floor in external walls upto 4th floor
Extra for each additional floor in external walls upto 4th floor
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work
Flush pointing to stone masonry wall in cement morter (1:3) including racking out joints (Cement 0.119 Cu.m/100 Sq.m)
WATERPROOFING AND MISCELLANEOUS WORK
Supplying & laying 3mm thick pre-fabricated plastomeric water proofing membrane conforming to EN 12311-1 & ASTMD 5147, manufactured with atactic poly propylene (APP) modified premium grade asphalt, specially reinforced with non-woven polyester core with polyester reinforcement @160 gms per sqm & both faces covered with thermo-fusible polyethylene film /MineraL on top face over a coat of primer @0.40 lit/sqm of manufacturer's specification on smooth,clean dry surface prepared wherever required. Lap joint shall be provided of 75 mm in longitudinal & 100 mm in transverse direction and fused using LPG/Propane torch employing extra care ensuring full bondage, complete removal of entrapped air and sealing edges into grooves in appropriate manner as per direction of Engineer -in-charge all complete including materials,labour and applicable taxes. (Payment shall be made on the basis of finished surface area.). Membrane Property: Softening Point > 150 deg C, Cold Flexibility < -6 deg C, Tensile Strength, N/cm : 600 (longitudinal), 450 (transverse), Tearing Strength, N:300 (longitudinal), 200 (transverse)
Supplying and laying standard six course bituminous water proofing treatment as per specification laid down in I.S. 1346 - 1991 to be finished with pea size gravel including necessary preparatory works such as shaping mouth of outlets, cutting chase as and where necessary and refilling with sand and Cement mortar (4:1) or Cement Concrete (1:2:4) with graded stone chips before undertaking the treatment including cutting grooves in parapet and inserting edge of felt and mending good damage complete in all respect as per direction of Engineer - in - Charge including cost of all materials and labours and incidental charges but excluding the cost of Cement Mortar or concrete required for levelling and grading. (In sloped roof Course sand of approved varieties is to be used in place of Pea size gravels as sixth and final course.) i) 1st, 3rd and 5th Course with bonding materials of hot applied industrial blown type bitumen of grade 85/25 or 90/15 conforming to I.S.702 - 1988 @ 12Kg/10Sqm on each course. ii) 2nd and 4th course with Hessian base self finished bitumen type-3 Gr.-I conforming to I.S. 1322-1993 (weighing 23kg/10Sqm gross with bitumen content 12.10kg/10Sqm ) tested under the provision of I.S. 13826 - 1993 part VII. iii) 6th course with washed and clean pea sized gravel or grit @ 0.006 cum/Sqm.A. Over flat roof
Supplying and fixing C.I. cover with frame for manholes : 600x600 mm square C.I. cover (Heavy duty) the weight of the cover to be not less than 210 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge
Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction /expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete:Serrated with central bulb ( 225 mm wide, 8-11 mm thick)
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design
Construction of granular sub- base by Providing close graded Material conforming to specifications,mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30
Providing , laying spreading and compacting graded stone aggregate ( size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub - base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer - in- Charge
(c) 60 mm thick interlocking designer concrete paver block M-35 grade for light-traffic zone,commercial & office complex,tourist resort as per IS: 15658-2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course &250 mm thk bound gnaular /granular sub-base course including cost of sand for sand bed but excluding cost of base ,sub-base course & subgrade preparation.) (ii) Coloured Decorative
EXISTING BUILDING DEMOLITION
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. a) In ground floor including roof.
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. First Floor
Add Extra rate for each addl. Floor over the rate of ground floor
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof. (a) upto 150 mm. thick
Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel (a) In ground floor including roof.
Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel (a) In first floor including roof.
Add Extra rate for each addl. Floor over the rate of ground floor]
Taking out carefully G.C.I. or C.I. or asbestos sheets (including ridges etc.) from roof or wall after unscrewing bolts, nuts, screws etc.and stacking the material at site as directed. (Payment to be made on measurement of portion of roof or wall removed.)
Dismantling carefully wood work in posts,postplates, rafters, partition etc., sorting and stacking serviciable materials at site and removing rubbish as directed
BOTANICAL GARDEN : Electrical Works
METERING PANEL Supply, installation, testing and commissioning of Outdoor type KSEB metering panel, including supply and accomodating CT operated TOD meter and consisting of 3 nos. of 100 A cutout with HRC fuse, neutral link, 100A FP MCCB with earth fault release in separate chamber,inter connections etc. as required, and necessary supports to be fabricated out of 14 SWG CRCA sheet with locable door with sealing facility having glass window for energymeter, sealing facility for KSEB, top canopy , weather proofenclosure (IP54)and necessary overhang, undergone seven tankprocess ,powder coated finish and all mounting accessories asrequired .The panel shall be with all accessories as per drawing &specification
UPS AND ACCESSORIES Supply, Installation, Testing and Commissioning of 15kVA,three phase input and output, built in isolation transformer at output side true on-line UPS system with 15 minutes back up at .9 pf, including all accessories, SMF batteries VRLA type with powder coated CRCA cabinet including all accessories such as cabling etc. as required complete having following specification. The UPS system consist of one number of UPS unit and one set of battery bank mounted in battery racks. Fully digital controlled based on DSP Power factor corrected from end 0.95 Pure sine wave output. Full time output voltage & frequency regulation Auto regulation of battery end voltage Intelligent interface with LED/LCD display Static bypass switch / manual bypass switch Auto temperature compensation
DG AND ACCESSORIES Supply, Installation, Testing and Commissioning of outdoor 58.5 KVA prime rated D.G Set with acoustic enclosure and Control panel ,protection and digital metering,controls and interlocks, CTs and transducers for all metering and protection and suitable FP MCCB etc. , including antivibration mountings, exhaust silencer and exhaust pipe conforming to latest environment protection regulations for emission and noise levels complete with , water/ coolant cooled, (radiator type) four stroke, electric start conforming to BS: 5514 58.5 KVA prime rating, brushless, self excited, self regulated and suitable for continuous operation at 1500RPM, generating 415 V+/-5% Volts at 0.8 p.f (lag), 50Hz,3 phase, 4 wire system generally conforming to BS: 2613 & IS: 4722. Both Engine and Alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads,battery stand, necessary control wiring with control cables, first fill of lubricating oil, and earthing as per standards Fuel tank , fuel piping from fuel tank o Engine, Residential silencer, suitable size Cable termination box with extended Alternator terminal with bus bars etc as required and as per specifications. RCC foundation rate considered in civil estimate. The work should be as per Electrical Inspectorate/ Pollution control board standards
CABLE & TERMINATION Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 3.5C 70 Sq.mm Al
Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 3.5C 50 Sq.mm Al
Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 4C 35 Sq.mm Al
Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 4C 16 Sq.mm Al
Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 4C 4sqmm Cu
Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 3C 4 sqmm Cu
Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 2C 4 sqmm Cu
Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 4C 1.5 Sqmm Cu
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables 3.5C 70 Sq.mm Al
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables 3.5C 50 Sq.mm Al
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables 4C 35 Sq.mm Al
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables 4C 16 Sq.mm Al
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables 4C 4sqmm Cu
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables 3C 4 sqmm Cu
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables 2C 4 Sqmm Cu
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables 4C 1.5sqmm Cu
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials 3.5C 70 Sq.mm Al
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials 3.5C 50 Sq.mm Al
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials 4C 35 Sq.mm Al
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials 4C 16 Sq.mm Al
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 4C 4sqmm Cu
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 3C 4 sqmm Cu
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 2C 4 Sqmm Cu
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 4C 1.5sqmm Cu
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting
Laying of cable above 3½ core 50 sqmm and upto 3½ core 90 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting
Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core
Laying only Cable above 50 sqmm but not exceeding 400sqmm through existing RCC/ Hume/GI Pipe/open masonary trench for single, 2, 3, 3½ and 4 core
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
Laying of two cables upto 35 sqmm in an underground trench in single tier formation (horizontal), the trench size : 680 mm x 760 mm average depth, with brick protection on the top of each cable 8 (eight) Nos. bricks per Mtr. and 4 (four) Nos. bricks per Mtr. as separator between the bricks and cables and also trench to be filled up with shifted soil, levelling up and restoring surface duly rammed
Laying of two cables above 35 sqmm and upto 185 sqmm in an underground trench in single tier formation (horizontal), the trench size : 680 mm x 760 mm average depth, with brick protection on the top of each cable 8 (eight) Nos. bricks per Mtr. and 4 (four) Nos. bricks per Mtr. as separator between the bricks and cables and also trench to be filled up with shifted soil, levelling up and restoring surface duly rammed
Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire. Up to 50 sqmm
Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire. From 70sqmm to 150sqmm
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required 50 mm
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required 100 mm
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. 150x50x1.25mm (18 SWG)
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. 300x50x1.25mm (18 SWG)
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
Supply, fabricating and installing MS items such as Tees/ angles/ channels etc. on floor/ ceiling/ wall including necessary civil work such as grouting, finishing etc. and painting with two coats of primer and two coats of synthetic enamel paint as required
WIRING AND ACCESSORIES
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish. Average run 5 mtr
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light points with 2 no. 2 way Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. Average run 9 mtr
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required.
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC
Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required
Supply & Fixing 240 V 16 A Piano key type switch (Brand approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required
Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Brand approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board
Supplying & Fixing 240 V AC Buzzer (Ancho) on HW board incl. S&F HW board
Supply & fixing Computer points with 3 nos 3 pin 5/6A socket with 2no.5/6A switch with modular front plate and cover on surface/recess, including proving and fixing suitable size GI boxs, its interconnections etc as required complete. (Note: 2 nos 5/6A socket fixed at 60cm above FFL and 2 nos 6A switch with 1no 5/6A socket at 1m above FFL)
Supply & Fixing RJ45 sitable for CAT6 cable (Brand approved by EIC) with PVC board and top cover plate on wall and making necessary connections & testing as required
Supply & Fixing Telephone socket (RJ11) Modular type (Brand approved by EIC) with PVC board and top cover plate on wall and making necessary connections & testing as required
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works 20 mm
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works 25 mm
Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supplying & Fixing GI Modular Switch Board of the following sizes complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works 2 Module
Supplying & Fixing GI Modular Switch Board of the following sizes complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works 4 Module
MCBs AND MCB DISTRIBUTION BOARDS
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment 6 Way
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection 100Amp,25 KA,FPMCCB
Supply of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 12 way (8 + 36), Double door
Supply of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 6 way (8 + 18), Double door
Supply of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (8 + 12), Double door
Fixing only Vertical type TPN MCBDB in Sheet Steel enclosure (4 to 12 way) on angle iron frame on wall
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 12 way, Double door
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 8 way, Double door
Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection RCCB as per specification as required 4 pole 40 amps. (415 Volts), 100mA sensitivity.
Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection RCCB as per specification as required 4 pole 25 amps. (415 Volts), 100mA sensitivity.
Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection RCCB as per specification as required 2 pole 25 amps. (240 Volts), 30mA sensitivity-
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection 6A to 32A, SP, C-CURVE
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection 6 A to 32 A TP MCB, C-CURVE
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection 40A TP MCB C CURVE
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection 63A TP MCB C CURVE
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection 40A FP MCB C CURVE
Supplying and fixing 240/415 V 40 FP MCB Isolator on din rail of existing DBs and necessary connection.
Supplying and fixing 240/415 V 63 FP MCB Isolator on din rail of existing DBs and necessary connection.
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supply installation, testing and commissioning of out door (IP 54 ) DOL starter upto 5HP, 3ph motor including auxiliary contactors, SPP relay , illuminated pushbuttons, provision for remote operation all the necessary accessories as required complete. The starter enclosure shall be made of powder coated 1.6 mm CRCA sheet.
Fixing only starters (for motor control) on flat iron frame / angle iron frame on wall Direct on Line starter for motor (upto 5 HP)
Supplying & Fixing Industrial Plug & Socket board with 240 V, 20A, SPN & Earth Metal Industrial Plug socket & 20A Industrial top incl. S&F 20 A SP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection
Supply and fixing outdoor type START/STOP (2way) push button station (IP65) including all the necessary accessories as required complete with suitable mounting arrangement.(Cat No Hensel-PBS 0201 or equivalent approved make)
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. For 12 way, Double door SPN MCBDB
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. For 8 way, Double door SPN MCBDB
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment 12 way (8 + 36), Double door vertical DB
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment 6 way (8 + 18), Double door vertical DB
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment 4 way (8 + 12), Double door vertical DB
Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required. MCCB as incomer
LIGHT FIXTURES AND FANS
Supply of 10 (+/-2) W High efficient LED batten surface/wall mounted, System efficacy of more than 100 lm/W and lumen output of luminaire greater than 1000 lumen, designed extruded channel in thermally conductive material with plastic with HET diffuser. CRI >80, Power factor>0.9, CCT - 6500K, 50000 burning hours as per L 70 criteria.
Supply of 20W Surface/Suspended Mounted LED Batten with System efficacy of more than 110 lm/Wand lumen output of luminaire greater than 2000 lumen. LED luminaire shall have sleek design with Extruded Aluminum Section. The luminaire shall have Optically Efficient Polycarbonate Diffuser for Uniform illumination and wider light distribution. The LED shall be compliant with LM80 standard with Useful L70 life of 50000 Hrs tested at maximum current. The CRI of Minimum 80 and 3 KV internal surge protection. Power factor greater than 0.9 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire
Supply of 36W , High efficient recess mounted 2 x 2 LED luminaire with CRCA housing &CRI>80, IP20, Ambient temp-0 to 45DegC, 50,000 hrs @L70 life.THD0.9, Surge protection-2 kV,prewired electronic driver, luminaire efficacy> 110 lm/W including all accessories necessary as required to complete installation.
Supply of 18W, High efficientrecess mounted LED round downlighter with white powder coated,Aluminium die cast aluminium housing.CRI>80, IP20, Ambient temp-0 to 45DegC, 50,000 hrs @ L70 life.THD0.9, Surge protection-2 kV, Inbuilt electronic driver, luminaire efficacy > 110 lm/W including all accessories necessary as required to complete installation.
Supply of IP 65 & IK 08 LED surface mounted Bulkhead fixture with System efficacy of more than 100 lm/W. Luminaire shall be made up of Die Cast Aluminium for efficient heat dissipation. Luminaire shall have Polycarbonate diffuser for Uniform illumination and wider light distribution. The LEDs used should be with CCT of 5700 K and CRI > 70, Power factor greater than 0.9 and total harmonic distortion (THD) of less than 10% including all accessories necessary as required to complete installation.
Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105 lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/ Lumilled/ Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
Supply installation testing and commissioning of of 6 Mtr hot dip galvanized octagonal pole conforming to BSEN 10025 & galvanization BS EN ISO 1461 or Equivalent with 3 mm sheet thickness and > 65 microns with confirming windspeed of 47 M/s . Pole should be of 70mm top dia and 130mm bottom dia . The pole should have inbuild door munting 500mm above from ground with proper gaskets & alien key arrangemnet for safety locking. Pole should withstand in 4 Nos of END hot dip galvanized M20x 600mm "J" bolts and baseplate of 200X 200mm with a 12mm thickenss conforming to IS 2062 . PCD=220mm . Conforming BSEN10025 ; BESEN ISO 1461 . Model : HM-1106P ; 1 Mtr Single Arm Hot dip galavanized included
Distribution wiring for street light on pole with 2x1/1.40 PVC insulated and sheathed (single core) in 15 mm dia GI pipe (ISI Medium), without control switch incl. S&F 30.48 cm outdoor type dispersive light fitting with GI Pipe bracket and providing 25x6 mm Galv. MS flat clamps with bolts, nuts etc. and incl. painting (Av. run 3m)
Supply of 225 mm sweep,900 rpm light duty exhaust fan in metal framework working on 230 V AC supply complete with all accessories as required
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required
Supply of 40W Surface/Suspended Mounted LED Batten with System efficacy of more than 110 lm/W and lumen output of luminaire greater than 4000 lumen. LED luminaire shall have sleek design with Extruded Aluminum Section. The luminaire shall have Optically Efficient Polycarbonate Diffuser for Uniform illumination and wider light distribution. The LED shall be compliant with LM80 standard with Useful L70 life of 50000 Hrs tested at maximum current. The CRI of Minimum 80 and 3 KV internal surge protection. Power factor greater than 0.9 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire
ITC LIGHT FITTINGS AND FANS
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connections, testing & commissioning etc as required.
Installation, testing and commissioning of LED type fittings on wall/Column/truss/false ceiling/slab of height 25m and above using 25mm heavy duty GI conduit of thickness 1.6mm (TATA, Jindal or equivalent) with GI clamps , adequate structural sections, antifall arrangement with 2mm PVC coated GI wire rope,necessay drilling only (without gas cutting) having the holes deburred or rounded using rubber grommets, spacers with 20mm long x ID 12 mm x OD 18mm,cotter pin, Stainless Steel nuts bolts and washers etc for a length of 1mtr including connections with 3C 2.5 Sq.mm PVC insulated flexible copper conductor cable ,ceiling rose etc complete as required.
Fixing only outdoor / street light type fluorescent light fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall and painting
Installation, testing and commissioning of LED down lighter fittings on false ceiling with all mounting accessories as required complete including interconnections using 3 core 1.5 sqmm FRLS PVC insulated flexible copper conductor as required.
Numbering of ceiling fan / exhaust fan/ fluorescent fitting as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
EARTHING AND SAFETY EQUIPMENTS
Excavation of soil for installation of Earth Electrode and filling & ramming For Soft Soil.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level By TATA-Medium GI pipe
Earthing with Copper plate (610x610x3mm size) having weight of 9.84 Kg and 1 No. 25x5mm Copper strip (3.20 mt long) & 1 no. 6 sqmm PVC insulated stranded Copper wire (4 Mt long) incl. S & F 15 mm dia GI pipe (ISI-Medium) protection (4 mt. long) to be fillied with bitumen, partly under the ground level & partly above ground level to an average depth of 3.65 Mts. below the ground level and restoring the surface duly rammed incl. providing 3.0 mt long, 25 mm dia GI pipe (ISI-Medium) for periodic treatment, incl. providing masonery enclosure on the top of the earth electrode of overall size 86.36x86.36x46cm deep (below Ground level) complete with cemented brick work (1:6) of 25 cm width, duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56x35.56cm with locking arrangement, GI reducer and treatment of soil by using salt & charcoal or coke for plate electrode
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required. 25mm X 3mm Cu
Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required. 3.15mm Cu (10 SWG)
Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 25mm X 5mm GI
Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 25mm X 3mm Cu
Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 3.15mm Cu (10 SWG)
Supplying of Rubber hand gloves suitable for 11 KV.
Supply and fixing anodised aluminum glass framed shock treatment chart
Supply and fixing of First aid box
Supply and fixing single line diagram, schematic diagrams etc. of A1 size including lamination etc. as required complete on wall.
Supply and fixing of of fire retardant/extinguishing electrical insulated synthetic mat of size 2m x 1m for 3.3kV grade 2mm thick, +/- 10% confirming to BIS: DOC No. ET-02 (5440) meeting requirements of IS:15652:2006 (with upto date amendment), suitable for 3.3kV voltage and having minimum width of 1000mm +/- 20mm and including supply of required quantity of adhensive / compound
LIGHTNING PROTECTION
Supply & Fixing of Testing Joints by 20 mm x 3 mm thick GI (Hot Dip) strip 125 mm long grouted on wall having clearance of 6 mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded Wire and 4 SWG GI (Hot Dip) wire of vertical conductor and conductor from earth electrode complete with S & F thimbles, GI bolts, nuts, check-nuts, spring washers etc. as required
S & F Lightning conductor Air-terminals made of 15 mm dia 1500 mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. duly grouted on the parapet etc. in CC mortar (4:2:1)
S & F of 4 SWG GI (Hot Dip) wire on Parapet/Roof/Plinth/ Surface of wall for lightning conductor as required (for Horizontal runs) with 40 mm long GI Staples spaced not exceeding 1300 mm apart incl. mending good all the damages to the building works
S & F of 4 SWG GI (Hot Dip) wire on wall for the lightning conductor as required (for vertical run) with GI Staples (40 mm long) spaced not exceeding 1 Mtr. apart incl. mending good the damages to building works (excluding hire charges of scaffolding)
Supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the Parapet/Roof/ Wall with GI Saddles 1100mm apart incl. mending good the damages to building works
Making soldered joints between conductors, conductors and air terminals for 4 SWG GI (Hot Dip) wire incl. supply of jointing materials and painting with 2 (two) coats of bituminous paint
Making soldered joints between conductors and down pipes/ other metallic objects for 14 SWG GI (Hot Dip) wire including supply of necessary 4 SWG GI (Hot Dip) wire, jointing materials and painting with 2 (two) coats of bituminous paint
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run
BOTANICAL GARDEN : Water Supply Works
SANITARY INSTALLATIONS
Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc.(a) With 'P' trap
Supplying, fitting and fixing Closet seat of approved make with lid and C.P.hinges, rubber buffer and brass screws complete.(a) E.W.C.(iv) Bestolite (solid type) white
Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete.i) Polythene Flush Pipe
Supplying, fitting and fixing 10 litre porcelain low-down cistern of approved make with either side or bottom inlet, side overflow, brackets complete with all internnal PVC fittings.White
Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete.
Supplying, fitting and fixing urinal flush pipe fittings of approved brand (a) C.P. urinal flush pipe fittings range of one.
Providing and fixing of star white vitreous china urinal division plate of approved quality and make with fittings/fastener including cutting and making good the walls, cost and conveyance of all material, labour charge, lead, lift, all taxes etc. complete as directed by the Engineer-in-Charge.
Supplying, fitting and fixing Half round channel with or without outlet as required set in cement concrete (6:3:1) with jhama chips complete,(Payment of concrete will be paid seperately). (i) 600 mm X 100 mm, (b) White vitreous chinaware
Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks,C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. (ii) 550 mm X 400 mm size
Supplying, fitting and fixing bevelled edged mirror 5.5 mm thick silver red as per I.S. 3438 / 1965 together with brass C.P. hinges.(ii) 600 mm X 450 mm
Supplying, fitting and fixing liquid soap container (a) Cromium plated.
Supplying, fitting and fixing towel rail with two brackets. (a) C.P. over brass (ii) 25 mm dia. and 600 mm long
Supplying, fitting and fixing porcelain toilet paper holder of approved make with wooden spindle as necessary.i) Roll type size 250 mm X 125 mm
(f) Hand Shower(Health Faucet) with 1mtr Fexible Tube with Wall Hook(Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar).
a(ii) Chromium plated Bib Cock long body with wall flange with aerator (Equivalent to Code No. 512 & Model - Tropical / Sumthing Special of ESSCO or similar brand)
b(ii) Chromium plated Concealed Stop Cock (Equivalent to Code No.514(A) & Model - Tropical / Sumthing Special of ESSCO or similar brand).
(d) (i) Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand)
AMBULANT DISABLED TOILET-Supplying, fitting & Fixing EWC (Size- 710x370x810 mm)in white glazed vitreous chinaware of approved make supplying, fitting and fixing in position complete with necessary nut and bolts. (Model Code No.S10221114-P Trap (CRUSE SET) of CERA or equivalent.)
Fittings of Ambulant Disabled Toilet-(a) Supplying, fitting and fixing 10 litre white glazed vitreous chinaware of approve low-down cistern of approved make with either side or bottom inlet, side overflow, brackets complete with all internal fittings. (Model Code No. S1060106 of CERA or equivalent.)White
Fittings of Ambulant Disabled Toilet (b)Soft Close seat cover of approved make with lid and C.P. hinges, rubber buffer and brass screws suppling, fitting and fixing complete. E W C (Model Code No. B1520118 of CERA or equivalent.) white
Fittings of Ambulant Disabled Toilet (c)Supplying, fitting and fixing Stainless steel Wall Mounted Grab Bar. Load bearing capacity 150 kg, covered by Nylon surface with contour finish (for better grip) with Anti- bacterial surface complete. (Model Code No. B2210106 of CERA or equivalent.) 600mm Long
Fittings of Ambulant Disabled Toilet (d)Supplying, fitting and fixing Stainless steel Wall Mounted Hinged hand rail (750X100 mm) covered by Nylon surface with contour finish (for better grip) with two brackets.(Model Code No.B2210108 of CERA or equivalent.) 750 mm long
Fittings of Ambulant Disabled Toilet (e)Supplying, fitting and fixing 15 mm Twin Flush Fitting (Model Code No. B1810112 of CERA or equivalent).
Fittings of Ambulant Disabled Toilet (f)Supplying, fitting and fixing 15 mm Spatula Single Lever Basin Mixer (Model Code No. F9030451 of CERA or equivalent).
Wash basin vitreous china of approved make (without fittings) supplied,fitted and fixed in position on 75mm X 75 mm X 75 mm wood blocks and C.I. brackets including two coats of painting of C.I. brackets. (ii) 550 mm X 400 mm size
Supplying, fitting and fixing complete Bottle waste trap (Heavy Quality)(a) Chromium plated Bottle trap 32 mm with 190 mm long connecting pipe and wall flange (Equivalent to Code No. 545 & Model - Tropical /Sumthing Special of ESSCO or similar brand).
Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets. (b) Sink with drain board 1050 mm X 450 mm X 180 mm
Supplying, fitting & fixing Aluminium domical grating.
WATER SUPPLY WORKS
Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). i)100 mm dia
ii) 80 mm dia
(iii) 65 mm dia
(iv) 50 mm dia
(v) 40 mm dia
(vi) 32 mm dia
(vii) 25 mm dia
(viii) 20 mm dia
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS- 15778: 2007 . with all necessary accessories,specials viz. socket, bend, tee, union, cross, elbo, nipple,longscrew, reducing socket, reducing tee, short piece etc.fitted with holder bats clamps, including cutting pipes,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. (a) For Exposed Work (i) CPVC Pipes Class-1, SDR-11 20mm
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS- 15778: 2007 . with all necessary accessories,specials viz. socket, bend, tee, union, cross, elbo, nipple,longscrew, reducing socket, reducing tee, short piece etc.fitted with holder bats clamps, including cutting pipes,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. b) For Concealed Work (i) CPVC Pipes Class-1,SDR-11 15mm
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories,specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew,reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc.clamps, including cutting pipes, making threads,fitting, fixing etc.complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line,measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (a) For Exposed Work PVC Pipes 40 mm
Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD -1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). With all necessary accessories, specials viz. socket, bend, tee, union, cross,elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc.fitted including cost of all materials ,jointing materials, cutting pipes,making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories,specials.) PVC Pipes 50 mm
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (f) 3000 litre capacity
Labour for hoisting plastic water storage tank. (ii)Above 1500 litre upto 5000 litre capacity (a) Upto 1st story from G.L.
(b) Extra for each additional story
Labour for punching hole in plastic water storage tank upto 50 mm dia.
SANITARY WORKS
Supplying, laying, jointing, testing and commissioning to the satisfaction of Engineer in charge of hard PVC pipes with PVC specials such as tees, bends, door bend, door tee, elbows,unions, etc. with clamps including cutting and making good the walls,testing the lines rectifying any leakages or defects,etc. complete for soil, waste, rain water,drains, vent pipe, etc. concealed or open at all levels including cost and conveyance of all materials, labour charges, sundries etc complete for concealed work as directed by the Engineer- in-Charge. 110mm OD (6 kg/cm2)
75mm OD(6kg/cm2)
50mm OD(6 kg/cm2)
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 Meter Length (a) 75 mm
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 A(ii) Double Socketed 3 Meter Length (a) 75 mm
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (iii) Single Socketed 1.8 Meter Length (a) 75 mm
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (iv) Double Socketed 1.8 Meter Length (a) 75 mm
B) Fittings i) Coupler a) 75mm
ii)Palin tee a) 75mm
iii) Door Tee a) 75mm
xi) Door Bend a) 75mm
xiii) Cross Tee a) 75mm
xv)Vent Cowl a) 75mm
xvi) Pipe Clip a) 75mm
xxix) Passover a) 75mm
xviii) W.C Connector (450mm long ) W/lipring-75mm
xxi) 110x 110, P Trap -75mm
Multi Floor Trap without Top tile & Strainer-75mm
Multi Floor Trap without Top tile & Strainer-110mm
Cleaning Pipe (a) 75 mm
Rubber Lubricant 500ml
Solvent Cement 250ml
Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerincharge. (Payment will be made on centre line measurement of the total pipeline including specials. (A) Above ground (i) 75 mm dia.
(ii) 110 mm dia.
(iii) 160 mm dia.
Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerincharge. (Payment will be made on centre line measurement of the total pipeline including specials. B) Under Ground (i) 75 mm dia.
(ii) 110 mm dia.
(iii) 160 mm dia.
Supplying, fitting and fixing yard gully with approved H.C.I. grating complete. (i) 225 mm X 150 mm with 230 mm gratings
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides,bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. i) With Pakur variety. (SAIL/TATA/RINL)
Providing and laying non-pressure NP2 class (medium duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete: 300 mm dia R.C.C. pipe.
Supplying, fixing,jointing, testing and commissioning to satisfaction of Engineer in charge of schedule 80 UPVC ASTM pipe and Schedule 80 ASTM-UPVC specials of approved make such as tees elbows, unions,bends,sockets bends,flanges, reducers, end caps,saddles, plugs,coupling, etc. including cost of all jointing materials like solvent cement, bolts, nuts, rubber washers,ferrule,pipe supports, cost of extra wastage of fittings during laying of pipe line such as rectification and recharging of the existing line as and when required etc.hire of tools and plant,trenching and refilling, cost and conveyance of water for testing after connecting to mains including all testing pipe line to the specified hydrostatic test pressure,rectifying any leakage or defects etc. complete.as directed by Engineer-in-Charge for water supply.-65mm Dia.
PUMPS, FILTERS AND ASSOCIATED ACCESSORIES
Supplying and fixing of centrifugal pump, with CI construction, CI impeller, mechanical seal,<br>complete with motor, base plate, foundation bolts, nuts ,pressure guage and all accessories. and<br>working with 415V, 3ph and 50 Hz frequency including cost and conveyance<br>of all materials, labour charges etc complete as directed by the Engineer in charge at all levels Capacity: 5m3/hr @ Head: 27m.(1W+1S)
Supplying and fixing of centrifugal pump, with CI construction, CI impeller, mechanical seal,<br>complete with motor, base plate, foundation bolts, nuts ,pressure guage and all accessories. and<br>working with 415V, 3ph and 50 Hz frequency including cost and conveyance<br>of all materials, labour charges etc complete as directed by the Engineer in charge at all levels Capacity: 3m3/hr @ Head: 27m.(1W+1S)
Supplying ,fixing, testing and commissioning of portable drainage pump 2HP , with stainless steel construction, stainless steel impeller complete with motor which shall be as per IS12615 and pump efficiency meeting ECBC standards , with all accessories and working with 415V, 3ph and 50 Hz frequency including cost and conveyance of all labour charges,lead,lift etc as directed by the Engineer in charge at all levels.
Supplying and Erecting air release valve 50 mm dia
Supplying and erecting air release valve 65 mm dia
Supplying and fixing of the Butterfly Valve Dia 50 mm of UPVC valves including all necessary fittings, cost and conveyance of all materials, labour charges etc as directed by the Engineer in charge at all levels.
Supplying and fixing of the Butterfly Valve Dia 65 mm of UPVC valves including all necessary fittings, cost and conveyance of all materials, labour charges etc as directed by the Engineer in charge at all levels.
Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 50mm.
Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 50mm
Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 65mm
Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 65mm.
Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 100mm
Supplying and fixing GM foot valve with all accessories including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer -in - charge at all levels. <50mm dia
Providing and fixing CI Y type strainer rating PN 10 complete with SS 304 filter screen of 1mm Perforation X 24G flanged and connection, flanges etc.including cost and conveyance of all materials,labour etc. complete and as directed by Engineer-in-Charge 50mm 'Y' type strainer.
Providing and fixing enclosed type water meter (bulk type) 50mm dia conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber etc. (The tail pieces if required will be paid separately) including cost and conveyance of all materials, labour etc. complete and as directed by Engineer-in-Charge.
BOTANICAL GARDEN : HVAC Works
Supply, Installation ,testing and commissioning of minimum 18 HP capacity Air-cooled VRF (Variable Refrigerant Flow) Outdoor unit with multiple compressors of variable speed inverter driven with suitable capacity drive motors conforming to IE3 as per IS 12615, air cooled condenser suitable for 3 phase, 415 V, 50Hz supply, R410A/R407C refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off, suitable interconnecting control cabling between IDUs , ODUs ,vibration isolator for Outdoor unit and GI mounting stand shall be included as part of equipment line item etc . Minimum Energy Efficiency of the equipment shall meet stringent of ASHRAE 90.1 and ECBC latest standards (whichever is superior). The item shall be complete in all respects complying to technical specifications. (Note: 1.Cost of equipment should be inclusive of necessary hardware /software gateway interface controllers etc.)
Supply,Installation,Testing and Commissioning of indoor evaporative units 4 way type Cassette of minimum 1.5 TR capacity with cordless remote comaptible with VRF system suitable for operation single phase, 230 V, 50Hz supply, including fixing of room unit, with high lift drain pump, drain connection with U-trap and all necessary fittings, elbows, structural supports etc. The item shall be complete in all respects complying to technical specifications.
Supply,Installation,Testing and Commissioning of indoor evaporative units 4 way type Cassette of minimum 2.0 TR capacity with cordless remote comaptible with VRF system suitable for operation single phase, 230 V, 50Hz supply, including fixing of room unit, with high lift drain pump, drain connection with U-trap and all necessary fittings, elbows, structural supports etc. The item shall be complete in all respects complying to technical specifications.
Supply, Installation ,testing and commissioning of indoor evaporative units Hiwall unit type of 1.0 TR minimum capacity compatible with VRF system including cordless remote, suitable for operation single phase, 230 V, 50Hz supply, including fixing of room unit, with high lift drain pump, drain connection with U-trap and all necessary fittings, elbows, electrical cabling from power plug, structural supports etc. complete in all respects as per the technical specifications.
Supply,Installation,Testing and Commissioning of following diameter Gas/ Liquid Copper Piping with with suitable thick insulation of closed cell nitrile rubber or closed cell physically crosslinked polyolefin foam, factory laminated Aluminium FSK facing of 12 micron thickness as mentioned in technical specification, complying to 25/50 rating as per ASTM E84, with minimum R value meeting the ECBC+ requirements for Refrigerant Piping Insulation, insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part of refrigerant piping. The thickness of insulation shall be as per ECBC+ requirements or 19 mm thickness whichever is higher. The item shall be complete in all respects complying to technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered to the nearest refrigerent pipe diameter in the line items mentioned. Both refrigerant suction and liquid line shall be insulated. Provision for Future takeoff shall be provided for each circuit. Dia- 31.75 mm ( 1 1/4") mmHard Copper Pipe 18 Guage with 19mm thick Insulation
Dia- 28.575 mm ( 1 1/8") Hard Copper Pipe 18 Guage with 19mm thick Insulation
Dia- 22.22 mm ( 7/8") Hard Copper Pipe 18 Guage with 19mm thick Insulation
Dia- 19.05 mm ( 3/4") Hard Copper Pipe 18 Guage with 19mm thick Insulation
Dia- 15.875 mm ( 5/8") Hard Copper Pipe 18 Guage with 19mm thick Insulation
Dia- 12.7 mm ( 1/2") Hard Copper Pipe 18 Guage with 19mm thick Insulation
Dia- 9.525 mm ( 3/8") Hard Copper Pipe 18 Guage with 19mm thick Insulation
Dia- 6.35 mm ( 1/4") Hard Copper Pipe 18 Guage with 19mm thick Insulation
Supply,Installation,Testing and Commissioning of PDI Compatible Central Controller, along with associated accessories for controlling entire VRF system & 25% spare capacity for future provisions with suitable interconnecting control cabling between IDUs, ODUs and central controller ,Power wiring with necessary supports. The item shall be complete in all respects complying to technical specifications.
Supply, Installation, Testing and Commissioning of minimum 1.0TR capacity Inverter- Decorative(Hi wall) Split air conditioning unit (Indoor and Outdoor Unit) with codensate high lift drain pump,complete with suitable capacity drive motor, air cooled condense with all accessories, hermetically sealed scroll/rotary compressor, outdoor unit and indoor units for single phase 230 V supply minimum 5 star rated as per BEE and with suitable stabilizer with necessary supports vibration isolators suitable as required as per manufacturers recommendation, suitable sized (diameter) copper refrigerant piping (for both suction and liquid piping) between indoor & outdoor units (upto 5m), duly insulated with suitable thick closed cell elastomeric Class 0 insulation complying to minimum R value meeting ECBC+ standards, complete insulation shall be finished with factory laminated 7mils glass cloth with required pipe fittings and accessories like bends,tees,reducers,supports complete,necessary power/control cabling as required, suitably supported on trays/ split clamps etc.,PVC condensate drain pipe 6kg/sq.cm of suitable dia connecting the drain pan of the indoor unit to nearest drain point with U-trap, insulated with 9mm thick closed cell nitrile rubber insulation, required pipe fittings and accessories like bends, tees, reducers, supports, clamps, finished with 7 mils factory laminated treated fibre glass cloth, first charge refrigerant gas R410A/R407C, cordless remote etc. The item shall be complete in all respects complying with technical specifications.
Supply,Installation,Testing and Commissioning of PVC drain pipe of 6Kg/Sq.cm (beyond 5 m) of suitable dia connecting the drain pan of the indoor units with necessary U-traps, elbows, fittings etc. to nearest drain point, with insulated with 9 mm thick closed cell elastomeric class 0 insulation with 7 mils factory laminated glass cloth as per specification required pipe fittings and accessories like bends, tees, reducers, supports, clamps, suitably supported on trays, clamps etc. The item shall be complete in all respects complying to technical specifications.
Supply and installation of ISI marked ABC Stored pressure type Fire Extinguisher 6 Kgs Capacity Mono Ammonium Phosphate based Dry Chemical Powder for Fighting ABC Class of Fire, stored Pressure type of Mild steel body pressurized by Nitrogen Gas. The Extinguisher shall conform to IS:15683, have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal abd wall bracket complete in all respect as per technical specification.
BOTANICAL GARDEN : Furniture Works
RECEPTION AREA
Reception Desk Top of the table shall be made up of 25mm Pre- laminated Particle Board as per IS IS: 12823, edges finished with 2mm PVC Lipping. Inside radius, outside radius and depth shall be 700, 1350 and 790mm respectively. It shall have counter frosted glass10mm thick with diamond cut finish on the edges. Inside radius, outside radius and depth of glass shall be 1202.5, 1402.5 and 200mm respectively.Worktop height shall be 750mm and Counter height shall be 1035mm .Angles sustained with the arc must be 60 degree. Modesty panel shall be made of MS perforated sheet and shall have dimensions 0.8mm (thick) x665mm (height) below the work surface and 0.8mm (thick) x 260mm (height) above the work surface. Legs of the desk shall be made of 18mm Pre- laminated Particle Board and height 604 mm. Approx .Size of Reception table shall be 2400mm (W) x 1060mm (D) x 1370mm (H). Pedestal units: 2 Nos pedestals made of good quality both side prelaminated Particle Board with 2 drawers and 1 storage cabinet. Drawers and cabinets to have locks openable with the same key and supported on castor wheels with locking device. The size of pedestal unit shall be 475 mm depth x 420 mm width x 725 mm height. The top, two sides, bottom, back & drawer/storage fascia are to be made of 25 mm thick both side pre laminated good quality Particle Board. The drawer/storage sides and bottom are to be made of 12 mm thick both side pre laminated good quality Particle Board.Key Board tray with mouse holder and Cpu trolley
Reception Chair The Seat and Back Cushion of the chairs should be pressed on 12mm hot press ply and PU foam. Height Adjustable Seat with lumbar support and waterfall edge. Overall Height of chair should be minimum 1100 mm (Inclusive of maximum adjustment of gas lift mechanism). The Gas lift mechanism should be tested as per BIFMA standards. Back/Seat Foam: Moulded PU Foam with density not less than 45- 52 Kg/m3. The polyurethane foam shall be as per manufacturer’s specification. It should be covered with fabric as per manufacturer’s shade card. (Fabric colour shall be approved by CLIENT). Arm Rest – Fixed armrest with PU arm Pad. Upholstery: Upholstered in leatherette finish The pedestal should be five legged injection moulded and fitted with 5 nos twin wheel castors. The must confirm to BIFMA Standards. Back - Height: 650mm; Width:500mm Seat - Height: 470mm Width: 460mm
Reception Chair Table made of prelaminated MDF board. Color shade: Brown. Size :60cm L X 37cm W X 57.5cm H. Make : Damro
Centre Table Table made of prelaminated MDF board. Color shade: Brown. Size : 900(w) x 500(D) x 450(H). Make : Damro
3 seater Sofa 1. SOFA 3 Seater: The seat shall be made of PU foam with Density 28 ± 2 kg / cub. mtr having an additional top layer of super soft PU foam in Density 32 ± 2 kg / cu . upholstered with fabric or leatherette. 2. The back is made of PU foam with Density 28 ± 2 kg / cub. mtr with two additional top layer of supersoftfoam of density 32 ± 2 kg / LEG ASSEMBLY: made of Mahogany Wood with PU polish. SIZE: 1950 (L) x 750(D)x 450(H) mm
COMMANDER IN CHARGE CABIN EXECUTIVE TABLE Size- 1300(L) x 600(D) x 750(H)mm -25mm thick Top Prelaminated particle board with with pvc edge banding., 18mm Leg Prelaminated particle board with pvc edge band. Modesty 18mm thick prelaminated partricle board with pvc edge band. 3 drawer Pedestal - 400(L) X 450(D) X 725(H)mm with 3 nos Drawer unit Made by 9mm thick back others all 17mm thick prelaminated particle board with pvc edge band. Provided with Key board tray and cpu trolley. All hardware included
EXECUTIVE CHAIR HECTER HIGH BACK CHAIR WHITE/GRAY NYLON - High Back revolving Chair with Mesh back & Cushioned Seat, Centre Tilt Mechanism with Single Point , Gas lift for height adjustment, Adjusteble Arms, 5 Prong Nylon Base with Twin Wheel castors.
VISITOR CHAIR ROBO MEDIUM BACK CHAIR WHITE/GREY - Medium Back revolving Chair with Mesh back & Cushioned Seat, Centre Tilt Mechanism with Single Point , Gas lift for height adjustment, Fixed Arms, 5 Prong Nylon Base with Twin Wheel castors.
FILE STORE ROOM FULL HEIGHT STORAGE Size- 2100(L) x 600(D) x 2100(H)mm -Openable shutter with inner shelf - 9mm back others all 18mm thick prelaminated particle board with pvc edge band. All hardware included.
COFERENCE ROOM CONFERENCE TABLE SIZE - 4100(L) x 1420(D) x 750(H)mm -25mm thick Top Prelaminated particle board with pvc edge band, 17mm Leg & Modesty Prelaminated particle board with pvc edge band. 2 nos Pop up box All hardware included.
VISITOR CHAIR ROBO MEDIUM BACK CHAIR WHITE/GREY - Medium Back revolving Chair with Mesh back & Cushioned Seat, Centre Tilt Mechanism with Single Point , Gas lift for height adjustment, Fixed Arms, 5 Prong Nylon Base with Twin Wheel castors.
SITUATION ROOM EXECUTIVE TABLE Size- 1200(L) x 600(D) x 750(H)mm -25mm thick Top Prelaminated particle board with pvc edge band, 18mm Leg Prelaminated particle board with pvc edge band. Modesty 18mm thcik prelaminated partricle board with pvc edge band.. All hardware included.
EXECUTIVE CHAIR HECTER HIGH BACK CHAIR WHITE/GRAY NYLON - High Back revolving Chair with Mesh back & Cushioned Seat, Centre Tilt Mechanism with Single Point , Gas lift for height adjustment, Adjusteble Arms, 5 Prong Nylon Base with Twin Wheel castors.
VISITOR CHAIR ROBO MEDIUM BACK CHAIR WHITE/GREY - Medium Back revolving Chair with Mesh back & Cushioned Seat, Centre Tilt Mechanism with Single Point , Gas lift for height adjustment, Fixed Arms, 5 Prong Nylon Base with Twin Wheel castors.
FULL HEIGHT STORAGE Size- 2100(L) x 600(D) x 2100(H)mm -Openable shutter with inner shelf - 9mm back others all 18mm thick prelaminated particle board with pvc edge band. All hardware included.
TREATMENT ROOM EXECUTIVE TABLE Size- 1200(L) x 600(D) x 750(H)mm -25mm thick Top Prelaminated particle board with pvc edge band, 18mm Leg Prelaminated particle board with pvc edge band. Modesty 18mm thcik prelaminated partricle board with pvc edge band.. All hardware included.
EXECUTIVE CHAIR HECTER HIGH BACK CHAIR WHITE/GRAY NYLON - High Back revolving Chair with Mesh back & Cushioned Seat, Centre Tilt Mechanism with Single Point, Gas lift for height adjustment, Adjusteble Arms, 5 Prong Nylon Base with Twin Wheel castors.
VISITOR CHAIR ROBO MEDIUM BACK CHAIR WHITE/GREY - Medium Back revolving Chair with Mesh back & Cushioned Seat, Centre Tilt Mechanism with Single Point , Gas lift for height adjustment, Fixed Arms, 5 Prong Nylon Base with Twin Wheel castors.
STANDERD HOSPITAL BED Plain hospital Bed With MS Head and Leg Board: Sizes: 1980 mm L X 910 mm W X 610 mm Features: •Fixed type bed •Mosquito pole arrangement •Mounted on rubber shoe •Finish with paint •Vertical support
FULL HEIGHT STORAGE Size- 2100(L) x 600(D) x 2100(H)mm -Openable shutter with inner shelf - 9mm back others all 18mm thick prelaminated particle board with pvc edge band. All hardware included.
DISCUSSION ROOM CONFERENCE TABLE SIZE - 4100(L) x 1200(D) x 750(H)mm -25mm thick Top Prelaminated particle board with pvc edge band, 17mm Leg & Modesty Prelaminated particle board with pvc edge band. 2 nos Pop up box All hardware included.
VISITOR CHAIR ROBO MEDIUM BACK CHAIR WHITE/GREY - Medium Back revolving Chair with Mesh back & Cushioned Seat, Centre Tilt Mechanism with Single Point , Gas lift for height adjustment, Fixed Arms, 5 Prong Nylon Base with Twin Wheel castors.
WHITE MAGNETIC BOARD Best quality White magnetic Marker Board edge banded aluminium anodised channel with plastic corner. Size- 1800 mm X 1200 mm
TRAINING ROOM DESKLET TRANING CHAIR Seat & Back made by 12mm thick hot presed ply with 50 mm thick 32 density foam upholstered with good quality fabric. The under structure should be made of 1 " dia tubular MS pipe 14 swg with powder coated tube and rubber bushes. Must have provision for bottom storage made of wire mesh and openable type writing pad made of 16 mm ply with 1 mm laminate finish with PVC edge banding finish. Size of Board : 21 ''x 9"
WHITE MAGNETIC BOARD Best quality White magnetic Marker Board edge banded aluminium anodised channel with plastic corner. Size- 1800 mm X 1200 mm
TECHNICAL ASSISTANT EXECUTIVE TABLE Size- 1300(L) x 600(D) x 750(H)mm -25mm thick Top Prelaminated particle board with pvc edge banding, 18mm Leg Prelaminated particle board with pvc edge band. Modesty 18mm thcik prelaminated partricle board with pvc edge band. 3 drawer Pedestal - 400(L) X 450(D) X 725(H)mm with 3 nos Drawer unit Made by 9mm thick back others all 17mm thick prelaminated particle board with pvc edge band. Provided with Key board tray and cpu trolley. All hardware included.
EXECUTIVE CHAIR HECTER HIGH BACK CHAIR WHITE/GRAY NYLON - High Back revolving Chair with Mesh back & Cushioned Seat, Centre Tilt Mechanism with Single Point , Gas lift for height adjustment, Adjusteble Arms, 5 Prong Nylon Base with Twin Wheel castors.
VISITOR CHAIR ROBO MEDIUM BACK CHAIR WHITE/GREY - Medium Back revolving Chair with Mesh back & Cushioned Seat, Centre Tilt Mechanism with Single Point , Gas lift for height adjustment, Fixed Arms, 5 Prong Nylon Base with Twin Wheel castors.
FULL HEIGHT STORAGE Size- 1500(L) x 600(D) x 2100(H)mm -Openable shutter with inner shelf - 9mm back others all 18mm thick prelaminated particle board with pvc edge band. All hardware included.
INFORMATION ASSISTANT EXECUTIVE TABLE Size- 1300(L) x 600(D) x 750(H)mm -25mm thick Top Prelaminated particle board with pvc edge banding., 18mm Leg Prelaminated particle board with pvc edge band.Modesty 18mm thcik prelaminated partricle board with pvc edge band. 3 drawer Pedestal - 400(L) X 450(D) X 725(H)mm with 3 nos Drawer unit Made by 9mm thick back others all 17mm thick prelaminated particle board with pvc edge band. Providedwith Key board tray and cpu trolley. All hardware included.
EXECUTIVE CHAIR HECTER HIGH BACK CHAIR WHITE/GRAY NYLON - High Back revolving Chair with Mesh back & Cushioned Seat, Centre Tilt Mechanism with Single Point , Gas lift for height adjustment, Adjusteble Arms, 5 Prong Nylon Base with Twin Wheel castors.
VISITOR CHAIR ROBO MEDIUM BACK CHAIR WHITE/GREY - Medium Back revolving Chair with Meshback & Cushioned Seat, Centre Tilt Mechanism with Single Point , Gas lift for height adjustment, Fixed Arms, 5 Prong Nylon Base with Twin Wheel castors.
PANTRY AREA EXECUTIVE TABLE Size- 1200(L) x 600(D) x 750(H)mm -25mm thick Top Prelaminated particle board with pvc edge band, 18mm Leg Prelaminated particle board with pvc edge band. Modesty 18mm thcik prelaminated partricle board with pvc edge band.. All hardware included.
VISITOR CHAIR ROBO MEDIUM BACK CHAIR WHITE/GREY - Medium Back revolving Chair with Mesh back & Cushioned Seat, Centre Tilt Mechanism with Single Point , Gas lift for height adjustment, Fixed Arms, 5 Prong Nylon Base with Twin Wheel castors.
OVERHEAD STOARGE UNIT Size- 2100(L) x 600(D) x 900(H)mm -Openable shutter with inner shelf - 9mm back others all 18mm thick prelaminated particle board with pvc edge band. All hardware included.
BOTANICAL GARDEN : ELV Works - Common for CCTV and Networking
Supply , Installation, Testing and Commissioning of CAT6 Cables as per specification
Supply , Installation, Testing and Commissioning of Medium Class ISI PVC conduit with all accessories as per the specification
Supply , Installation, Testing and Commissioning of 27U rack (1000 depth) with all accessories as per the specification
Supply , Installation, Testing and Commissioning of 6U rack with all accessories as per specification.
Supply , Installation, Testing and Commissioning of cat6 patch cord 1mtr with all accessories as per specification
Supply , Installation, Testing and Commissioning of cat6 patch cord 2mtr with all accessories as per specification.
Supply , Installation, Testing and Commissioning of cat6 voice patch panel Fully Loaded with all accessories as per specification.
Supply , Installation, Testing and Commissioning of cat6 24 port patch panel Fully Loaded with all accessories as per specification.
Supply , Installation, Testing and Commissioning of cat6 I/O with back box and face Plate with all accessories as per specification.
Supply , Installation, Testing and Commissioning of 16Port PoE Switch as per specification
Supply , Installation, Testing and Commissioning of CCTV Server with 16CH supported having 90days of recording as per specification
Supply , Installation, Testing and Commissioning of 10TB Harddisk as per specification. ( Storage specified here in is Tentative, Bidder shall compute the actual storage and proide the required Storage)
Supply , Installation, Testing and Commissioning of 5MP IP Dome/Bullet Camera with all accessories per specification.
Supply , Installation, Testing and Commissioning of 2MP IP Motorized Dome/Bullet Camera as per specification.
Supply , Installation, Testing and Commissioning of 10 bay NAS of 100TB storage(Including Hard Disk) with all accessories as per specification.
Supply , Installation, Testing and Commissioning of Centralized Video Management Software with all accessories as per specification
Supply , Installation, Testing and Commissioning of 20W SIP based Speaker(Ceiling/Wall Mount) as per specification.
Supply , Installation, Testing and Commissioning of 2 Core Speaker Cables as per specification.
Supply , Installation, Testing and Commissioning of PA Sytsem Controller/ software for announsment and music as per specification.
Supply & ITC of 85" Interactive Display 24/7 with HDMI, VGA, USB Ports, Backlit LED (IPS Panel) , 4K Ultra-HD (3840 x 2160), Touch Tools:- Finger, Stylus, Glove, Opaque Objects, Panel Size; Aspect Ratio : 86”, 16:9, Built in Speaker (10W x 2CH), HDMI 2(Rear 1, Front 1), DP 1, OPS I/F, 4 drawing (Internal) 20 touch (External) with OPS asper Specification.
Supply of 20x PTZ Full HD camera for video conferrencing asper Specification
Supply of Mini PC i5, 8GB RAM, 500GB HDD/SSD, HDMI and DI Port with Audio IN and OUT, USB, Wireless Keyboard and Mouse asper Specification
Supply of Conference Control unit as per Specification
Supply of Chairman Unit with 38mm or more length Gooseneck MIC with Speaker asper Specification
Supply of Delegate Unit with 38mm or more length Gooseneck MIC with Speaker asper Specification
Supply of 120W Audio Power Mixer Amplifier(inbuilt equlizer) with 3 input As per Specification
Supply of 20W ceiling /wall mount Analog Speaker and all accessories required at site to complete the work as per specification
Supply of Feed Back Suppressor for controlling the sound as per specification
Supply of high perfomace single channel UHF wireless microphone with reciever
Supply of cables (Speaker cable, ethernet cable, Sound Card, HDMI, Cable Cubby and VGA cables) and all other relavend accessories requiered for the proper working of the entire system in the board room (measurments of cables may vary its depends on site requirment)
Supply , Installation, Testing and Commissioning of 100 User firewall with 3yr Licence as per specification.
Supply , Installation, Testing and Commissioning of WiFi based bio metric attendance system as per specification
Supply , Installation, Testing and Commissioning of SIP Based phones as per specification.
Supply , Installation, Testing and Commissioning of Analog Phones white color as per specification.
Supply , Installation, Testing and Commissioning of 24 Port IP to Analog converter as per specification.
Supply , Installation, Testing and Commissioning of IP based EPABX system as per specification
Supply , Installation, Testing and Commissioning of WiFI -6 WITH 2*2 MIMO access point as per specification
Supply , Installation, Testing and Commissioning of Server PC i9 Intel Processor 8GB RAM wirh 256GB SSD and Win 10 Pro with all accessories as per specification.
Supply , Installation, Testing and Commissioning of Videowall Display - 4 x 4 as per specification.
Supply , Installation, Testing and Commissioning of Mounting Structure as per specification.
Supply , Installation, Testing and Commissioning of 4K Multi-Window Video Processor with HDBaseT® & HDMI® Outputs as per specification.
Cables & Connectors
Installation & Labour Charges
BOTANICAL GARDEN : IT Works
Computer Supply of i7 processor with 12 Gen, 8GB RAM, 512GB SSD, with UBS , HDMI ports with window 11 Pro
Internet Leased Line (ILL) Supply , Installation of Internet Leased Line (300Mbps)
Sip Connection Supply , Installation of sip connection
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 4.81 MB
BOQ_2381234.xls
BOQ • 0.65 MB
BotanicalGarden.pdf
Additional Documents • 0.88 MB
Download all tender documents and submit your bid