| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹6.8 CrAccepted-AOC HOUSE OF RAJ KUMAR GOEL PO MATELLI MATELLI BAZAR JALPAIGURI | MATELLI BAZAR | JALPAIGURI | WEST BENGAL | ₹6.8 Cr | L-1 | Accepted-AOC L-1 Bidder. |
| 2 | L-2₹7.1 CrRejected-Finance OFFICE NO 304 305 3RD FLOOR PLOT NO 1 USHA CHAMBERS L S C NEW RAJDHANI ENCLAVE DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | ₹7.1 Cr | L-2 | Rejected-Finance Rejected. Other than L-1. |
| 3 | L-3₹7.5 CrRejected-Finance | ₹7.5 Cr | L-3 | Rejected-Finance Rejected. Other than L-1. |
| 4 | L-4₹7.9 CrRejected-Finance | ₹7.9 Cr | L-4 | Rejected-Finance Rejected. Other than L-1. |
| 5 | L-5₹12.4 CrRejected-Finance SITANI BUILDING DINBAZAR JALPAIGURI 735101 | JALPAIGURI | JALPAIGURI | WEST BENGAL | 735101 | ₹12.4 Cr | L-5 | Rejected-Finance Rejected. Other than L-1. |
| Sl No | Description | Qty | Unit | G and G Infratech Private Limited L2 | ANUGRAH CONSTRUCTION PVT. LTD. L1 | M.P. SITANI AND SONS L5 | DOOARS CONSTRUCTION COMPANY L4 | M/S. S.K. TEKRIWAL L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00BUILDINGS & STRUCTURE (Sch 'A' PART-I) | ||||||||
| 1.01 | Lump sum price worked out by the Contractor for “Design, Construction, Fabrication and Erection of SHOPPING COMPLEX including RCC LIFT WELL & RCC TERRACE TANK of capacity 20000Ltr : SHOPPING COMPLEX incorporating RCC framed as well as LGSF (Light Gauge Steel Frame) Structure Technology on the basis of conceptual / Line Plan drawings all as specified and shown on drawing, DBR and other documents of the Tender and as mentioned in Annexure I to this Schedule shall be submitted by the contractor alongwith Soil Investigation complete duly vetted by IIT/NIT & approved by the Department. ” as listed in Schedule ‘A’ Part-I.
NOTE: SCHEDULE 'A' PART I (TO BE QUOTED BY THE CONTRACTOR) is not prepriced by MES and prepriced rates indicated as blank under col 5 signifies this fact only. Bidders shall insert their lumpsum amoun in the Green coloured field under Col-6 only. | 1 | COMPLETE JOB | 5,64,00,064 ₹5,64,00,064 | 5,50,00,000 ₹5,50,00,000 | 10,91,73,007 ₹10,91,73,007 | 6,37,30,513 ₹6,37,30,513 | 6,05,00,000 ₹6,05,00,000 |
| 2.00EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT (Sch 'A' PART-II) | ||||||||
| 2.01 | Lump sum price worked out by the Contractor for “EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT” as listed in Schedule ‘A’ Part-II.
Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 2,56,908.70 inserted by the MES in Schedule ‘A’ Part-II. | 1 | LUMP SUM | 2,95,500 ₹2,95,500 | 1,75,000 ₹1,75,000 | 2,82,599.57 ₹2,82,599.57 | 2,50,000 ₹2,50,000 | 2,69,754.14 ₹2,69,754.14 |
| 3.00HARDSTANDING (Sch 'A' PART-III) | ||||||||
| 3.01 | Lump sum price worked out by the Contractor for “(HARDSTANDING)” as listed in Schedule ‘A’ Part-III.
Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 32,74,958.85 inserted by the MES in Schedule ‘A’ Part-III. | 1 | LUMP SUM | 39,15,790 ₹39,15,790 | 31,00,000 ₹31,00,000 | 36,02,454.74 ₹36,02,454.74 | 31,50,000 ₹31,50,000 | 36,02,454.73 ₹36,02,454.73 |
| 4.00SEWAGE DISPOSAL (Sch 'A' Part-IV) | ||||||||
| 4.01 | Lump sum price worked out by the Contractor for “(SEWAGE DISPOSAL)” as listed in Schedule ‘A’ Part-IV.
Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 2,51,223.38 inserted by the MES in Schedule ‘A’ Part-IV. | 1 | LUMP SUM | 3,22,390 ₹3,22,390 | 2,65,000 ₹2,65,000 | 2,76,345.72 ₹2,76,345.72 | 2,50,000 ₹2,50,000 | 2,81,370.18 ₹2,81,370.18 |
| 5.00AREA DRAINAGE(Sch 'A' PART-V) | ||||||||
| 5.01 | Lump sum price worked out by the Contractor for “(AREA DRAINAGE)” as listed in Schedule ‘A’ Part-V.
Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 6,42,787.73 inserted by the MES in Schedule ‘A’ Part-V. | 1 | LUMP SUM | 7,83,765 ₹7,83,765 | 6,45,000 ₹6,45,000 | 7,07,066.5 ₹7,07,066.5 | 6,35,000 ₹6,35,000 | 7,19,922.26 ₹7,19,922.26 |
Tender Value
₹8.9 Cr
EMD Value
₹7.7 L
Closing Date
14 Jan 2026, 6:00 pmClosed
CE SILIGURI ZONE
HQ CE SILIGURI ZONE, MES, SEVOKE ROAD, PO SALUGARA, DIST JALPAIGURI, PIN 734 008 (WB)
PROVISION OF SHOPPING COMPLEX AT SUKNA MILITARY STATION UNDER GE SUKNA
2025_MES_742736_1
98826/SUK/SZ/E8
Open Tender
Civil Works
540 days
SUKNA
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
GE SUKNA
₹7.7 L
Yes
26 Mar 2026
3 Dec 2025
21 Jan 2026
3 Dec 2025
14 Jan 2026
31 Dec 2025
3 Dec 2025 - 11 Dec 2025
BUILDINGS & STRUCTURE (Sch 'A' PART-I)
M&L for Horizontal boring for passing GI protection pipe up to 80 mm bore (dia), under road/ foot path, not exc. 10.00 metre in a single length, complete all as specified and as directed.Note : (i) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (ii) Any damage to existing cables any type and pipe line in the way of drilling the bore will be repaired and make good by the contractor within 24 hours. No extra cost will be paid in this account. (iii) Contractor has to get the survey of route, length and depth for boring before quoting the rate.
EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT (Sch 'A' PART-II)
Lump sum price worked out by the Contractor for “EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT” as listed in Schedule ‘A’ Part-II. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 2,56,908.70 inserted by the MES in Schedule ‘A’ Part-II.
HARDSTANDING (Sch 'A' PART-III)
Lump sum price worked out by the Contractor for “(HARDSTANDING)” as listed in Schedule ‘A’ Part-III. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 32,74,958.85 inserted by the MES in Schedule ‘A’ Part-III.
SEWAGE DISPOSAL (Sch 'A' Part-IV)
Lump sum price worked out by the Contractor for “(SEWAGE DISPOSAL)” as listed in Schedule ‘A’ Part-IV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 2,51,223.38 inserted by the MES in Schedule ‘A’ Part-IV.
AREA DRAINAGE(Sch 'A' PART-V)
Supply and fixing Galvanised Iron Fire bucket 9 ltr Red in colour as per approved OEM specification complete all as specified and as directed
EXTERNAL WATER SUPPLY (Sch 'A' PART-VI)
Lump sum price worked out by the Contractor for “(EXTERNAL WATER SUPPLY)” as listed in Schedule ‘A’ Part-VI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 20,591.89 inserted by the MES in Schedule ‘A’ Part-VI.
EXTERNAL ELECTRIFICATION (Sch 'A' PART-VII)
Lump sum price worked out by the Contractor for “(EXTERNAL ELECTRIFICATION )” as listed in Schedule ‘A’ Part-VII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 21,40,996.19 inserted by the MES in Schedule ‘A’ Part-VII.
FIRE FIGHTING & FIRE ALARM SYSTEM (Sch 'A' PART-VIII)
M&L for Construction of Septic tank ( for 100 Users) conventional type, designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Brick wall RCC M-30 in Roof Slab etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.30 meter complete all as shown on TD drawings No CESZ/2019/TD-115 Sheets 1/4 to 4/4 and directed. NOTE : Necessary Earthwork shall be included in the quoted rate.
LIFT (Sch 'A' PART-IX)
Lump sum price worked out by the Contractor for “(AREA DRAINAGE)” as listed in Schedule ‘A’ Part-V. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 6,42,787.73 inserted by the MES in Schedule ‘A’ Part-V.
DEMOLITION & DISMANTLING (Sch 'A' PART-X)
Lump sum price worked out by the Contractor for “(DEMOLITION & DISMANTLING)” as listed in Schedule ‘A’ Part-X. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 14,392.88 inserted by the MES in Schedule ‘A’ Part-X.
MISCELLANEOUS ITEMS REQUIRED FOR B/R & E/M SERVICES (Sch 'A' Part-XI)
M&L 150mm bore,HDPE double wall corrugated(DWC) SN-8 PIPE (HDPE Black Pipe) WITH COUPLER Conforming to IS:16098 Part-II:2013 sewage pipes laid in trenches and jointed as per manufacturer,s instruction with and including all fitting complete all as specified and as directed.
Lump sum price worked out by the Contractor for “Design, Construction, Fabrication and Erection of SHOPPING COMPLEX including RCC LIFT WELL & RCC TERRACE TANK of capacity 20000Ltr : SHOPPING COMPLEX incorporating RCC framed as well as LGSF (Light Gauge Steel Frame) Structure Technology on the basis of conceptual / Line Plan drawings all as specified and shown on drawing, DBR and other documents of the Tender and as mentioned in Annexure I to this Schedule shall be submitted by the contractor alongwith Soil Investigation complete duly vetted by IIT/NIT & approved by the Department. ” as listed in Schedule ‘A’ Part-I. NOTE: SCHEDULE 'A' PART I (TO BE QUOTED BY THE CONTRACTOR) is not prepriced by MES and prepriced rates indicated as blank under col 5 signifies this fact only. Bidders shall insert their lumpsum amoun in the Green coloured field under Col-6 only.
Supply, install, testing and commissioning of indoor cubical type LT Control Board, factory fabricated CPRI type tested and relevent IEC certification with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-43 & general construction confirming to IS-13947, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming MCCB rating. The panel board shall be fabricated out of 2.0 mm thick CRCA sheet duly pre-treated & powder coated, supporting frame made out of 50 x 50 x 6 mm angle iron suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl PCC platform/plinth of suitable size complete all as specified & as directed with & incl the following accessories :- BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos tinned copper 100 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections form main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables. INCOMING (i) MCCB FP, 63 Amps rating, Ics=100%Icu, 16 kA breaking capacity, adjustable thermal magnetic release - 01 No Item Continued as Srl No. 11.23
M&L for construction of brick masonary valve pit of intermal dimensions 600mm x 600mm x 600mm complete and fabrication of 3.0 mm thick MS sheet cover and angle iron frame made out of 40mm x 40mm x 6mm MS angle iron and one side provided with hinge with locking arrangement & duly painted with two coats of black bituminous paint over a coat of red oxide primer including necessary earth work and PCC work as shown in drawing and specifieid complete directed.
M&L for construction of Soakage wells excavation, in any type of soil, walls of honey combed masonry, RCC cover slab in M25, bat filling interconnecting pipes of DWC complete filled with brick bats of size 1.80 m dia X 6.0 m effective depth complete all as shown on TD drawings No SZ/TD-14 Sheets 1/1 and directed. NOTE : Necessary Earthwork shall be included in the quoted rate.
M&L for jumper connection between OH line to GOD and GOD to drop out fuses with ACSR conductor 6/1X3.35 mm (rabbit) not exe. 2 mtr long including necessary lugs where ever required/aluminum heavy duty PG clamps contact all as directed including PVC sleeve not more than 1.70 Rm with and including all connected acessories as per OEM recomendation complete all as specified and directed.
S & Fof Pole mounted Junction box with terminals minimum size 182 x 180 x 111 mm ,made of high quality thermoplastic polycarbonate, dust and jet water proof, chemical, acid corrision, impact IK-09, insulated & shock proof IP 66, grey RAL 7035 color with internaly embedded gasket (PUR) , along with cover and metric knockout all sides including back of the base must including terminals 4Nos including fixing arrangement with MS flat of size 40X4mm , nuts , bolt and washers and MCB SP 6-32 Amps 01 No with and including all connected acessories as per OEM recomendation complete all as specified and directed.
OUTGOING :- (i) MCCB 4P of capacity 250 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 25 KA with thermal magnetic release & lcs=100 % lcu - 02 Nos (01 x Spare) (ii) MCB TPN 16 Amps rating, 10 kA breaking capacity,'C' curve, ISI marked - 02 Nos ( 01 No Spare) (iii) Analog time switch, Programmed via captive segment. Power supply: 230 V~ 50/60 Hz, 3-Position override switch "ON-AUTO-OFF" on front panel. 16 Amp with 100 Hr working resurve - 01 No (iv) ML-1 Power Contactor, 415 Volt, 3 Pole, Conforming to IS/IEC 60947-4-1 & IEC 60947-4-1, Standard Coil Voltage 240V, rating 20 Amps - 01 No (v) Danger notice plate of size25 x 20 cm of 1.6 mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal-red color and fixed with MS clamp and bolt and nuts of approved size for LT conforming to lS:2551 complete-02 nos
Supply, installation, testing and commissioning of APFC Capacitor panel board cubical type of size not less than (1.2x1.0x0.6)m depth not less than 0.60 M fatory made (CPRI tested and IEC certification ), outdoor use single door , back side& front both side openable in to two halve, inner door for individual controls, MCCBs & Capacitor, contactor etc with locking arrangement made out of 3.15 mm thick CRCA Sheet supported on ,50 x 50 x 6 mm angle iron and Tee section frame dust and vermin proof,well ventelated with exhaust fan of suitable size complete, powder coated with aluminium bus bar 4 Nos, 400 Amps capacity duly PVC sleaved with colour coading mounted on porcelain insulators with suitable size of PVC insulated copper cable control wiring duly pedestal mounted to match the existing feeder pillar complete to accommodate and including the following. (80KVAR=5*1+12.5*2+25*2) (a) Ultra Heavy duty capacitor box oil filled type of capacity 5 KVAr,440 volt 3 phase -01 Nos (b) Ultra Heavy duty capacitor box oil filled type of capacity 12.5 KVAr,440 volt 3 phase -02 Nos (c) Ultra Heavy duty capacitor box oil filled type of capacity 25 KVAr,440 volt 3 phase -02 Nos (d) APFC RELAY Model No- etaSMARTR or equivallent with 1 CT input , 5 Amps ,415 Volts,AC 6 Steps with RS 485 communication port for Modbus Data transfer complete. (e) MCB three pole 16 Amp ,415 Volt ,10 KA :01 No (f) MCB three pole 16 Amp ,415 Volt ,10 KA :02 Nos (g) MCB three pole 63 Amp,415 Volt,10kA : 02 Nos (h) Digital meter for digital parameter such as Voltage, Ampere,Power Factor , Frequency, KWH , 3 Phase ,Class 1, 5A,with RS 485communication port for Item Continued as Srl No. 11.11
MODBUSS Data transfer complete.:01 No (j) MCCB Four pole 200 Amp 50 kA adjustable thermal magnetic release with threshold and Adjustable Over Load setting. :01 No (k) Capacitor Duty MO C type contactor(1 NO+1NC), low operating losses high widhstand capacity as per capacitor capacity .(5x1+12.5x2+25x2) KVAr: 01 Set for all Capacitor Banks (l) Indicating lamp LED type 220vac(red,yellow & green in colour):15 Nos (m) Push button with NO/NC 220vac:10 Nos (n) Copper Lugs 16sq mm:15 Nos (o) Suitable capacity CT's. -05 (Set of 3) (p)Painting as per CPRI (q) Danger notice plate.-01 No. (r) Panel control wiring with 16 sqmm s/c copper wire complete - 01 Job.
S&F of PVC insulated unshearthed multistandard, copper conductor cable, 1100 volts grade of size 2.5 Sqmm 3 core drawn into extg street light pole/arm complete all as specified and as directed
S&F for MS cabinet Minimum size 750 mm x 600 mm x 450 mm) to encl fire brigade inlet connections fabricated from 16 gauge sheet with full front glass door and locking arrangement painted and mounted on masonry platform and other connected acessories as per OEM recommendation complete all as specified and as directed
S&F Valve, reflux, with by-pass Arrangement, 100 mm (4”) dia as per OEM specfication complete all as specified and as directed
S&F for XLPE insulated heavy duty FRLS copper ammoured conductor 2.5 Sqmm 6 Core, with working voltage 1100 volts conforming to IS: 1554 part -I, all as specified and as directed. (From Control panel to Terrace pump)s to get the survey of route, length and depth for boring before quoting the rate.
Supply and fixing fire extingusiher, Dry Chemical Powder, ABC type 6.00 kg Capacity complete with initial charge and wall bracket BIS and BSEN standard as per approved OEM specification and other connected acessories as per OEM recommendation complete all as specified and as directed
Supply and fixing Fire Extinguisher CO2 Type (light weight squeeze grip type) 4.5 Kg BIS standard as per approved OEM specification and other connected acessories as per OEM recommendation complete all as specified and as directed
Supply and fixing Fire Extinguisher Water Stored Pressure Type 9.0 Ltr capacity BIS standard as per approved OEM specification and other connected acessories as per OEM recommendation complete all as specified and as directed
Supply and fixing Fire Extinguisher Mechanical Foam Type 9.0 Ltrs capacity BIS standard complete all as specified and as directed
S&F auto-illuminated (glow-in-dark) exit sign board with red colour background with appropriate symbol, made up of acrylic sheet for fire escape in minimum 10 cm x 30 cm size to be pasted on wall with high quality ad
hesive or to be hanged with s.s. hook-chain system and other connected acessories as per OEM recommendation complete all as specified and as directed
Lump sum price worked out by the Contractor for “(LIFT)” as listed in Schedule ‘A’ Part-IX. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 37,32,703.38 inserted by the MES in Schedule ‘A’ Part-IX.
Supply and fixing rechargeable type ceiling/wall mounted Escape lighting showing exit sign in green colour provided with in-built battery suitable to provide minimum 90 min contineous lighting after power cut as per approved OEM specification and other connected acessories as per OEM recommendation complete all as specified and as directed
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.49 MB
Complete_Tender_Except_BOQ.pdf
Tender Documents • 10.51 MB
BOQ_831720.xls
BOQ • 0.32 MB
Drgs.rar
Additional Documents • 21.25 MB
Download all tender documents and submit your bid