Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹22.8 L+₹1.8 L (8.70%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹23.0 L+₹2.1 L (9.87%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹24.0 L+₹3.1 L (14.7%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹24.2 L+₹3.2 L (15.4%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
3 Dec 2020, 6:00 pmClosed
GE Kamptee
Garrison Engineer, Military Engineer Services, Kamptee Cantt - 441 001
REPAIRS /REPLACEMENT OF ROOFING, FLOORING, CONNECTING BUILDING WKS AND REPAIRS / CLEANING OF SEWAGE LINE, MANHOLES, SEPTIC TANKS, DRAINS AND CERTAIN B/R WORKS OF CERTAIN UNIT OF HQ UM AND G SUB AREA UNDER AGE B/ R-II AT NAGPUR.
2020_MES_393433_1
8217/E8
Open Tender
Civil Works
Item Rate
270 days
Nagpur
Class E, Cat a (i) and a (ii)
7 documents required · 7 mandatory
₹500
Yes
GE Kamptee
₹40,000
Yes
31 Dec 2020
7 Nov 2020
5 Dec 2020
9 Nov 2020
3 Dec 2020
21 Nov 2020
9 Nov 2020 - 20 Nov 2020
Amount
Dismantling wall and ceiling boards (Fiber, pulp, insulation etc) or insulation boards, slabs, blankets or of any description in any thickness including cover fillets complete all as specified and directed.
S&F GI framework for seamless ceiling of size 600mm x 600 mm comprising of hot deep galvanized powder coated perimeter angle 0.30 mm thick of size 24x24 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre, main runner Tee section 0.3 mm thick with height 32 mm and cross Tee 0.3 mm thick with height 28 mm suspended from soffit at approx 1200 mm centre to centre with GI cleat and steel expansion fasteners, including drilling holes for 2mm dia GI wire suspender and clips etc complete as per manufacturer's recommendations complete all as specified and directed. Note:- (i) Ceiling boards shall be measured separately. (ii) The grid system shall be as per specifications of make as specified and directed.
M&L for non-asbestos designer fiber cement building boards of size 595 x 595 x 4mm fixed or laid/ inserted to GI frame work with screws/ clips as in ceiling laid flat or sloping complete all as specified and directed. Note:- GI frame work will be measured and paid for separately.
Removing existing water proofing treatment on roof including screed bed and scrubbing down with water etc and removing the same beyond premises of MD land complete all as specified and directed.
M&L for 25mm (avg) thick cement concrete type B-0, 1:2:4 (using 12.5mm graded stone aggregate) finishing cement concrete surface even and smooth without using extra cement using water proofing liquid @ 200 ml/50 kg of cement complete all as specified and directed. Note:- Water proofing liquid will be measured & paid separately.
Supply only liquid water proofing admixture of Make:- Pidilite or equivalent complete all as specified and directed.
M&L for provision of water proofing treatment by using APP torch on mineral/ slate finished membrance over roof and vertical surfaces including preparation of surfaces and applying oil based bituminous primer coat @ 0.30 ltr per sqm on clean and dry surface and then providing APP membrane having non woven polyster film reinforcement with 3 mm thick and weight not less than 3.00 kg/sqm and finished on top with mineral/slate finished torch on system laid with 100mm & 150mm over lap on side & end laps resepectely all as per manufacturers instructions over and including rendering 15mm thick in cement mortar 1:3 on concrete surfaces complete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description not otherwise specifically provided for complete all as specified and directed.
M&L for roof trusses (framed), trussed, purlins, crane ganbies, rails and fastenings and heavy bracket framing (lleam, tee, angle, charmel or flat sections) including distance pieces, cleats etc. conforming to IS 1161-1979 grade Fe 290 (Gde E-165) complete all as specified and directed.
Dismantling of AC (Corrugated or semi corrugated etc) sheets in roof covering including ridges complete all as specified and directed.
M&L for 6mm thick asbestos cement corrugated or semi-corrugated sheets in roof, walls including fixed with L type or J type or cranked hook bolts complete all as specified and directed.
M&L for 6mm thick asbestos cement one piece plain angulal ridge including fixed with L type or J type or cranked hook bolts complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in mortar complete all as specified and directed.
M&L for vitrified ceramic tiles 10mm thick (square or rectangular) polished, light shade, area of each tile not exceeding 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm cement screed bed in cement mortar 1:6 complete all as specified and directed.
M&L for coloured non skid ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding. 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed with white or coloured cement to match over and including 15mm thick screed bed of cement mortar (1:6) etc complete all as specified and as directed.
M&L for coloured non skid ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc set and jointed in neat cement slurry and pointed with white or coloured cement to match over and including 15mm thick screed bed of cement mortar (1:6) etc complete all as specified and as directed.
Dismantling of unserviceable floor, hearth or wall tiling including cement mortar bedding (but not backing) and removal of rubbish/ debris from premises of MOD land complete all as specified and directed.
M&L for colored glazed ceramic tiles in vertical surface 350x 250x 7mm/ 450x 350x 7mm/ 300x 450x 7mm thick, set and jointed in neat cement slurry and pointed in white or colored cement to match including rendering 10mm thick in cement mortar 1:4 complete complete all as specified and directed.
Taking down cement plaster of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick work or concrete surface in cement plaster (1:6) surface finished fair and even complete all as specified and directed.
M&L for preparation of new surfaces of wall and applying two coats of oil bound distemper over a coat of birla white wall care putty complete all as specified and directed
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc complete all as specified and directed.
M&L for brickwork with fly ash brick, old size, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM (1:4) finished fair and even complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for and removal of rubbish/ debris outside MD land complete all as specified and directed.
M&L for 75mm thick cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in subbase complete all as specified and directed.
M&L for 40mm thick cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in floor finished even and smooth without using extra cement complete all as specified and directed.
M&L for 75mm thick cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in floors finished even and smooth without using extra cement complete all as specified and directed.
S&F in repairs vitreous china wash down water closet (pedestal pattern) 'P' or 'S' trap including jointing including plastic water closet seat, closed pattern with flat bottom, cover and mild steel CP or aluminimised hinging device complete all as specified and directed.
S&F in repairs plastic water closet seat, black/ white, closed pattern with flat bottom, cover and mild steel chromium plated or aluminimised hinging device complete all as specified and directed.
S&F in repairs vitreous china squatting pan "Orissa pattern" 580 x 440mm long with integral foot rest, S or P trap including connection to trap and to flushing pipe etc including making good to floor complete all as specified and directed.
S&F in repairs 10 ltr capacity PVC valve less symphonic action type flushing cistern, low level, white with inlet ball valve, float and handle including bracket etc complete all as specified and directed.
S&F in repairs wash hand basin (flat back or angle back) of size 550 x 400mm, white, including waste pipe, chain and plug, porcelain stopper including for & pinning in ends of brackets including supply & fixing of waste pipe complete all as specified and directed.
S&F 32mm waste fittings, brass, chromium plated for glazed ware sinks, basins, etc with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed.
S&F 15mm bore GI water tubing, medium grade, galvanized with all fittings & fixture, fixed to walls and ceilings or laid in floors including taking up or down steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed.
S&F 20mm bore GI water tubing, medium grade, galvanized with all fittings & fixture, fixed to walls and ceilings or laid in floors including taking up or down steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed.
S&F 15mm bore bib taps, chromium plated, cast copper alloy, fancy type, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F in repairs 15 mm bore chromium plated bib taps long body, cast copper alloy, Fancy type, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repair 15mm bore pillar tap, brass, CP fancy type complete all as specified and directed.
S&F in repair 125mm size shower rose, brass chromium plated complete all as specified and directed.
S&F in repair 15mm bore bib tap, standard of PTMT any colour, high pressure, screwed for iron pipe and fixed complete all as specified and directed.
S&F in repairs rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 500 litres capacity, hoisted and fixed in position and including dismantling of existing water tank and removing from site complete all as specified and directed.
S&F in repairs rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 1000 litres capacity, hoisted and fixed in position and including dismantling of existing water tank and removing from site complete all as specified and directed.
S&F 20mm bore ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe and fixed (Minimum weight 20mm - 210gms) complete all as specified and directed.
S&F in repairs floor door stopper of 140mm aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed.
S&F in repairs 20mm dia stainless steel curtain rod of approved quality including cutting and fixing to curtain brackets complete all as specified and directed.
S&F fancy type curtain brackets of approved quality fixed to wall with screws complete all as specified and directed.
S&F wire brush with aluminium section 25mm x 1mm and brooms to fill the gap of floor and door shutter complete all as specified and directed.
S&F corner glass shelf 300mm (with brass brackets) 300x600mm complete all as specified and directed. Make:- Prayag Cat No BEA-44 or equivalent.
S&F in repairs health faucet with 1 mtr tube and hook complete all as specified and directed. Make:- Prayag cat No.: BEA-81 or equivalent.
S&F glass shelf 500x125mm (with brass brackets) complete all as specified and directed. . Make:- Prayag Cat No.: BEA-45 or equivalent.
S&F in repair wall cabinet mirror of size 500x400mm Appx or equivalent complete all as specified and directed.
M&L for preparation of old plastered or unplastered surface of any desciription exc 10cm in width or girth and applying one coat of weather shield paint (Apex) complete all as specified and directed.
M&L for complete removal of existing treatment of wall and applying two coats of weather shield paint (Apex) over coat of primer and 3mm thick wall care putty complete all as specified and directed.
M&L for complete removal of existing treatment of wooden surface and applying two coats of wooden polishing over a coat of wood filler (primer) complete all as specified and directed.
M&L for complete removal of existing treatment of and applying one coat of birla white putty to make the surface smooth and applying two coats of acrylic emulsion over a coat of primer including rubbing the surface by emrry paper etc complete all as specified and directed.
M&L for preparing old painted surfaces of wall and applying one coat of cement base paint complete all as specified and directed.
M&L for complete removal of existing treatment of wall and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
M&L for one coat of synthetic enamel paint on old painted wooden surface including preparation of surfaces complete all as specified and directed.
M&L for preparation old steel and iron surface not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparing old decorative surface of wall and applying one coat of oil bound distemper complete all as specified and directed.
M&L for preparing old decorative surface of wall and applying two coats of oil bound distemper complete all as specified and directed.
M&L for complete removal of existing treatment of wall and applying two coats of oil bound distemper over coat of primer and 3mm thick wall care putty complete all as specified and directed.
M&L for brooming down surfaces of any description and applying one coat of white wash on old decorated surfaces of walls including preparation of old surfaces & filling cracks and holes etc complete all as specified and directed.
M&L for brooming down surfaces of any description and applying two coats of white wash on old decorated surfaces of walls including preparation of old surfaces & filling cracks and holes etc complete all as specified and directed.
Taking of existing cover of septic tanks/ soak well & cleaning of septic tank/ soak well of any size/ capacity by mechanical sewage sucking pumping machine and transport the sludge in to a mechanical sewage carrier tank for removing the same to a distance 10 to 15 KM from defence land and placing back in position the removed cover complete all as specified and directed by Engineer-in-Charge. Note:- (i) Net quantity of sludge removed shall be measured and paid as quoted by the contractor. (ii) The excavation and earth work of pit in any type of soil is deemed to be included in the unit rate quoted by contractor. (ii) No extra payment shall be made for dewatering and cleaning with water which shall deemed to be included in the unit rate of this item.
Cleaning of blocked sewer/ sewage line of any discription (SGSW/ RCC/ CI pipe) of 100mm/150mm/ 200mm dia or any dia at any depth by rodding or by mechanical means and well flushing the complete sewer line with water from manhole to the entire satisfaction of Engineer-in-charge with and including taking out and re-fixing of manhole covers where required complete all as specified and directed.
Taking off existing manhole cover & cleaning of manhole (any size/ depth) by dewatering and taking out rubbish/ sludge etc by mannual or by mechanical means and removing the same to a distance not exc 50 mtr and put into newly excavated earth and placing the removed cover back in position complete all as specified
Cleaning of blocked / chocked nahani trap/ floor trap including drain/ sewer/ sewage line of any discription (SGSW/ RCC/ CI pipe) of 100mm/ 150mm/ 200mm dia or any dia at any depth by rodding or by mechanical means and well flushing the complete sewer line with water upto first manhole to the entire satisfaction of Engineer-in-charge with and including taking out and re-fixing of manhole covers where required complete all as specified and directed.
Excavation over areas not exc 1.5m deep and getting out in hard / dense soil complete all as specified and directed.
Excavation over areas depth exc 1.5 m and not exc 3.0m deep and getting out in hard / dense soil complete all as specified and directed.
Excavating in trenches, not exc 1.5m wide and not exc 1.5m depth; for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc. not exc 10 sqm on plan and not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25cm in soft/loose soil complete all as specified and directed.
Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
M&L for loose filling with broken bricks of guage 80 to 150mm in soakage pits / soakage wells complete all as specified and directed.
Demolition of cement concrete bed in hauching and breaking up drain pipes, SGSW set in cement mortar of the 100mm dia complete all as specified and directed.
Demolition of cement concrete bed in hauching and breaking up drain pipes, SGSW set in cement mortar of the 150mm dia complete all as specified and directed.
M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in bed to drain pipe of 150mm bore including packing under and hauching against the sides of pipe after they are laid and tested complete all as specified and directed.
M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in bed to drain pipe of 100mm bore including packing under and hauching against the sides of pipe after they are laid and tested complete all as specified and directed.
M&L for 100mm bore SGSW drain pipe, grade A, laid in trenches and jointed in CM 1:2 complete all as specified and directed.
M&L for 150mm bore SGSW drain pipe, grade A, laid in trenches and jointed in CM 1:2 complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for precast RCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in landings, cover slabs, for manholes etc and similar articles with plain faces, set in cement mortar 1:4 complete all as specified and directed.
M&L for mild steel TMT bars 8mm dia and over, cut to length, bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M&L for providing PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in coping etc including necessary form work complete all as specified and directed.
Use & waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landing horizontal or slopping, similar work not exc 200mm thick and flat fair finished surfaces complete all as specified and directed.
M&L for reinforced cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies deck slabs, in shelves and the likes complete all as specified and directed.
M&L for extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement, including forms etc complete all as specified and directed.
M&L for PCC (1:2:4) type B-0 (using 20mm graded stone aggregate) as in surface channel and drain finished even and smooth using extra cement complete all specified and directed.
Dismantling of cast iron pipe of 100mm dia jointed in cement mortar and taking out in trenches, if required complete all as specified and directed.
S&F cast iron soil, waste and vent pipes 100mm in any length with or without ears, with cement joints complete all as specified and directed.
All as per item No 95 above but 75mm bore complete all as specified and directed.
S&F in repairs CI bends (any radius) diminishing pieces or tapers (larger bore mearsured) for 100mm dia complete all as specified and directed.
S&F in repairs CI bends (any radius) diminishing pieces or tapers (larger bore mearsured) for 75mm dia complete all as specified and directed.
S&F in repairs 100mm bore CI branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access doors complete all as specified and directed.
S&F in repairs 75mm bore CI branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access doors complete all as specified and directed.
Dismantling PVC pipes (110/75mm) jointed in cement mortar and taking out of trenches/ from walls including fittings as bends, branch pieces, traps etc complete all as specified and directed.
S&F in repairs 110mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F in repairs 75mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F in repairs 110mm bore PVC (SWR) junction double, (Double T) equal or unequal complete all as specified and directed.
S&F in repairs 75mm bore PVC (SWR) junction double, (Double T) equal or unequal complete all as specified and directed.
S&F in repairs 110mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F in repairs 75mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F in repairs 110mm bore PVC (SWR) bends any radius with access doors complete all as specified and directed.
S&F in repairs 75mm bore PVC (SWR) bends any radius with access doors complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed.
S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed.
S&F in repairs 125/110mm PVC (SWR) gully trap, setting and jointing with solvent cement complete all as specified and directed.
S&F 15mm PVC connections with PTMT nuts of length 450mm complete all as specified and directed.
NOTE:- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs.30,080.00]
SHUB CONSTRUTION
M/s DS Khekde
Devika Constructions
Meet Road Lines
Shri Mohan Brother
Bidder Name
Meet Road Lines
SHUB CONSTRUTION
M/s Rahul Traders
Shri Mohan Brother
M/s DS Khekde
Devika Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .