Loading…
Loading…
Tender Value
₹60.7 L
EMD Value
₹1.2 L
Closing Date
16 Feb 2026, 3:30 pmClosed
Protection/ shifting of S&T cables and provision of FOIS connectivity for development of Goods sheds along with circulating area and approach roads at various stations on Solapur division of Central Railway.
SUR-N-T-2025-26-39~CR
SUR-N-T-2025-26-39
Open
Works - General
8 Months
Solapur, Maharashtra
₹0
₹1.2 L
16 Feb 2026
22 Jan 2026
2 Feb 2026
A-Tender Schedule
Item Breakup - A-Tender Schedule
Supply of Indoor Access Points similar to TP-Link Numbers EA225-POE from Cisco or TP Link or D-Link or Ubiquity. (Inspection by Consignee)
Supply of Network Management interface & Numbers driver unit as per specification. (Inspection by Consignee)
Supply of Multifunction Machines (MFM) as per Numbers specification with on site OEM Warranty of 3 Year from HP or cannon or Epson or Brother. (Inspection by Consignee)
Supply of 8 Port Smart Managed Switch with 8- Numbers Port Giga PoE Ethernet & 2-Port Giga SFP loaded with SM Fiber Transceiver (1310nm) of reputed make such as TP Link/ DLink/ Cisco/ Juniper only. (Inspection by Consignee) SOLAPUR DIVISION-S AND T/CENTRAL RLY
Supply of Control IP telephones (PoE) without Numbers hands free and attachable gooseneck (microphone with base unit) operation for way side control telephone as per clause 8 of RDSO specification No.RDSO/SPN/TC/ 99/2023 Ver 3.0 or latest . (equipment to be compactible with existing system of the division) (Inspection by Consignee)
Supply of Media converters with one Fiber port Pair (SC connector) and four Ethernet ports, supporting port isolation and with built in AC Power supply. Model: FABIO 104L of make MRO- TEK or similar model of RAD, ANDA Telecom, ZYXEL or CTC only. (Inspection by Consignee)
Supply of High throughput LAN extenders as per Pair RDSO specification No.RDSO/SPN/ TC/80/2020 Rev 2.0 or latest. (Inspection by Consignee)
Supply of 1 TB External Extreme portable SSD Numbers (Type C and A) for backup of configuration of the stations in portable format from ADATA or Scandisk or Seagate or Transcend or Samsung. (Inspection by Consignee)
Supply of Wall Mounting Speaker BOSCH/ Numbers L'Acoustic /Renkus Heinz or superior. All necessary accessories required for installation will be supplied/provided by contractor. (Inspection by Consignee)
Supply of Analog Display, metal body hand Numbers driven Insulation Tester 100V 100 MOHMS with lead cables; make Waco-WI 104, Nippen, Fluke, Motwani. (Inspection by Consignee)
Supply of single line caller ID hand free Numbers telephone with speaker of make Beetel M 53 or latest with RJ 11 rosettes and 3 No. of pen torch cells Eveready or Novino to be supplied with each instrument as per specification and warranty of 01 year. (Inspection by Consignee)
Supply of Krone module of 10 pair each from Numbers Krone or DAX or OBO or R&M make. Firm to submit documentary evidence with supply that item is procure from OEM. (Inspection by Consignee)
Supply of multiport I/O box surface mounting Numbers having two RJ-45 port and three RJ-11 port from D-Link or Legrand or Anchor or similar reputed make. (Inspection by Consignee)
Fixing of UTP I/O box as per the instruction of Numbers site Engineers of the Railways.
Supply of PVC switch board 10 Pair, 0.5mm dia. Metre twisted pair PVC insulated, PVC sheathed, ATC copper conductor as per TEC specification no.TEC/GR/WIR009/05 March 2011 or latest from Network or Finolex or Synergy or Delton make. (Inspection by Consignee)
Supply of PVC switch board 05 Pair, 0.5mm dia Metre twisted pair PVC insulated, PVC sheathed, ATC copper conductor as per TEC specification no. TEC/GR/WIR/06/03 March 2002 or latest from Network or Finolex or Polycab or Delton make. (Inspection by Consignee)
Supply of CAT 6 UTP 24 port loaded patch panel Numbers from D-Link or Avaya or Lucent or AT&T or Comscope make. (Inspection by Consignee)
Supply of STP (shielded Twisted Pair) CAT-6 Boxes cable from D-Link, Finolex, Lucent or DAX Make(1 Box-305 mtrs) (Inspection by Consignee). SOLAPUR DIVISION-S AND T/CENTRAL RLY
Laying of CAT 6 cable with proper identification Metre marks and as per the instruction of site engineer.
Supply of factory molded Cat-6 patch cord 1 Mtr Numbers from D-link or DAX or Krone or Finolex make. (Inspection by Consignee)
Supply of OFC patch cord with connector at Numbers both ends single mode Simplex 05 Mtr. Make of 3M or Sterlite or Finolex or Raychem. (Inspection by Consignee)
Supply of OFC patch cord with connector at Numbers both ends single mode Simplex 10 Mtr. Make of 3M or Sterlite or Finolex or Raychem. (Inspection by Consignee)
Supply of optic fiber pigtails for termination of Numbers OFC cables with following specification: a) It shall be single mode SC/SC type with push pull mechanism or as per site requirement and fully compliance with latest industry standard. b) It shall have length of 2 Meters at least. c) It shall have SC connector at one end and other shall be loose for splicing. d) It should be of reputed make D-Link or 3M or Digilink or Molex. (Inspection by Consignee)
Supply of 6 fibre single mode armoured Metre OPTICAL FIBRE Cable as per ITU-TG 652D specification make D-Link or Digisol or AMP or Molex make. (Inspection by Consignee)
Blowing/drawing of OFC cable in HDPE/DWC Kilometre duct and protective work, as per direction of site engineer.
Supply of fiber distribution management system Numbers (24 fiber) as per RDSO spec No.RDSO-SPN-TC- 37-2000 (ver 3.0) with 24 No., FC/PC connector, 24 No. pigtails and 24 No. patch cords of 3 mtr suitable for FDMS under supply. (Inspection by Consignee)
Supply of 12 port LIU, 19 inch rack mountable Numbers as per following specification: a) It should have12 SP type ports for termination of SM optical fibres. b) It should be rack mountable with 1U height. c) It should be equipped with front managed saddle for jumper/patch cord management. d) It should have 12 SC termination. e) It should be equipped with adequate nos.of splicing trays to splice 12 fibres. f) It should have proper rubber grommet for cable protection and to minimize dust build up. g) It should be fully loaded with all the accessories for splicing and termination of fibres. h) It shall be of reputed make like D-Link or 3M or Digilink or Molex make. (Inspection by Consignee)
Installation & commissioning of 12 port LIU with Numbers all accessories and shall be used for terminations of optical fibers into the splice trays supplied with it, it shall be installed inside the 19 inch rack using all required fixing/ installation material like nuts, bolts, screws and cable ties etc. as per requirement. The splice trays shall be placed and secured into the LIU after splicing. The SC terminations shall be fixed and secured after splicing of the pigtails into the LIU. It shall be ensured that the movement of the trays is easy and free of any obstructions. SOLAPUR DIVISION-S AND T/CENTRAL RLY
Splicing/ fiber/pigtail in LIU/IObox/terminal joint through fusion splicing for termination of OFC cables. The fibers terminated shall be tested and test report (hard copy and soft copy) shall be submitted to the Railways site in-charge for records. each fiber shall be properly marked with necessary ferrules/tags, as per following specification: i) The optical fibre cables shall be entered in to the rack through cable entry and using the cable guides. ii) The loosened ends of the fibres and pigtails shall be properly prepared for termination in to the already fixed LIU. iii) Eachof the fibre shall be spliced witha pigtail by the method of fusion splicing using a Fusion Splicing Machine of standard reputed make. The splicing shall be done carefully by a skillful person. iv) The splices shall be carefully placed and well secured in the splice trays of the LIU. v) Each fiber /pigtail shall be properly marked with necessary ferrules/tags.vi) The extra length of the fibers / pigtails shall be coiled and placed and secured with cable ties. vii) The optical connectors of the pigtails shall be placed into the patch panel as per the numbering of fibers. viii) All of the terminated fibers shall be tested with OTDR and test report (Hard copy and Soft copy) shall be submitted to the Railways site In-charge for records.
Supply of 9U wall mounting rack of size 600 mm Numbers wide and 500 mm depth, cabinet made up of steel powder coated light gray painted, glass door with lock and key and other complete accessories such as 5x 6A power socket module, 2 fan trays etc. from HCL or President or APW or Valrack. (Inspection by Consignee)
Supply of on line UPS with isolation transformer Numbers suitable for signal phaseAC input & single phase AC output, floor mounted type. Rating of UPS 3.0KVA, indicative back up time 120 minutes, make APC or Immerssion or Microtek or Champion with SNMP module card installed in UPS. (Inspection by Consignee)
Supply of SMPS based battery chargers as per Numbers RDSO spec. No. RDSO/Spn/TL/23/99 Ver. 4 or latest for Telecom use, 230 Volts AC/48 Volts DC, 50 Amps. using three modules of 25 Amps in 1+2 configuration. (Inspection by RDSO)
Supply of Maintenance free VRLA Battery set of Numbers standard make similar to Exide / Amararaja, 2V per cell, 300 AH capacity in stack of 24 cells for giving a out put voltage of 48V complete with associated base plates interconnecting cables, connectors for the rows and cells with all accessories as per RDSO Specification No.IRS 93/96(A) Amdt.1 or latest. (Inspection by RDSO)
Installation, Testing and Commissioning of Set Battery set with battery charger as per site condition with all tools & plant, petroleum jelly and accessories as required.
Supply of Lighting surge arrestors for LAN Numbers network class C type as per VDE classification housed in a suitable impact resistance box. The equipment shall support one input and one output port with provision for ground connection for surge suppression. the equipment shall be from Ubiquiti or Tuvpavco or DiTek or Tripp-Lite. (Inspection by Consignee) SOLAPUR DIVISION-S AND T/CENTRAL RLY
Supply of Class B&C surge protection Device Numbers (SPD) type I & II with visual indication and potential free contract to remote monitoring as per RDSO spec No. RDSO/SPN/165/2012 version 3.0 or latest and IEC standard 61643 for signals line 230 V AC application with handling lightning surges of 10/350 microseconds and switching surges of 8/20 microseconds. One set consists of 3 Nos of SPD (Two Nos of B Class (L N, N-E) and one no of C class (L-N) all enclosed in a box with KEMA or VDE certified as per latest IEC 61643-11-2011 standard class B&C surge protection device required with Three modules only. (Inspection by Consignee)
Supply of Thermo shrink joint kit suitable for 6 Numbers quad cable for straight through/ derivation transformer as per RDSO specification No.IRS- TC-77/2012 (Rev.3.0) Amdt.3 or latest. from RDSO approved firms. (Inspection by RDSO)
Making through/derivation/ transformer /PIJF cable joint for underground jelly filled cable 6 quad/4quad/20 pair 10 pair etc. PIJF cable as per the instruction of Rly engineer at site.
Supply of PVC channel of size 50x50 mm with Metre all accessories like joint, bends etc of precision, Garware make or similar standard make. (Inspection by Consignee)
Supply of PVC casing & capping of size 25mm x Metre 25mm x 1mm thickness of Precision or Garware or Presto make. (Inspection by Consignee)
Fixing of PVC casing caping of size 25mm/ Metre 50mm as per the instruction of site engineer.
Supply of Permanently Lubricated HDPE Metre Telecom duct of size 50/42 mm and accessories as per latest Specification TEC GR No. GR/TX/CDS-008/03/March 11 with latest amendment for OFC cable of size 24 fibre armoured in length of 1000 mtrs/roll. Duct to be supplied from TEC approved sources. (Inspection by Consignee)
Laying & fixing of HDPE duct for protection of Metre cable in trenches or roof wall etc as per route given by site Engineer of Railways.
Supply of HDPE pipe 110 mm Diameter, PE63, Metre Class PN6, with confirming to IS4984 with ISI marked (or) Latest. Type test report from Central Govt./state Govt/NABL/ILAC to be submitted at the time of supply. (Inspection by Consignee)
Supply of GI pipe, inner dia. 100mm dia. B-class Metre asper spec. No.IS 1239 PT. 1/2004 or latest with sockets and fittings. TATA, JINDAL/ ZENITH BIRLA make. (Inspection by Consignee)
Fixing of GI pipes for crossing the culverts, Metre bridges etc. and concreting of ends with brick masonry at both ends as per the instruction of Rly engineer at site.
Laying bridges/culverts/concrete drawin/mountain ridges etc. with suitable GI bend shall be provided where there is turning of pipe as per the instruction of Site engineer. GI clamps at every 2m as shown in the drawing to be fixed. Suitable holes to be made in the pipe before laying as per the instruction of the site engineer 10mm dia Drg. No. SK 808. SOLAPUR DIVISION-S AND T/CENTRAL RLY
Supply of PVC conduit pipe of size 25mm x Metre 2mm of pipe heavy duty with all accessories of Astral make or similar reputed make. (Inspection by Consignee)
Conceal Wiring with cutting the wall and repair Metre in 04 Inch width. This includes supply of Concealing pipe/channel also.
Supply of Polyolefin cable channel 2434 as per Metre RDSO specification vide letter No.STS/Cable- Laying Practices Vol-IV dated 09.05.2018 or later if any. (Inspection by RITES)
Supply of RCC pipes half round of size 150mm Numbers 1000.00 dia. outer and 100 mm dia. internal 1 mtr. long matching to IS No. 458/2003 amendment-1 with Rev.4. (Inspection by RITES)
Laying of RCC half round cement pipe of Numbers appprox. Size (150/300mm dia. X 2 mtr. length) inside the trench after laying of cable. Pipes shall be placed asper directives of site engineer.
Supply of Paints as per relevant IS specification Kg preferably Asian/Apcolite/Dulux make in different colours in 1 Kg/2 Kg pack. (Inspection by Consignee)
Supply of Apparatus Case with Godown locks Numbers with detachable handle on both the doors. Half Case as per Drg No SK 783-1/2. with latest alteration. (Inspection by RITES)
Excavation and Casting of Apparatus Case Numbers foundation with contractors Anchor bolts, cement, ballast and other materials. Half Case as per Drg No SK 804.
Erection of Apparatus Cases. This includes filling Numbers of location foundations with river bed sand and plastering on top of the sand. Half Case
Painting of two coats of synthetic enamel paint Numbers over one coat of primer on the following after scrapiing & cleaning surface wherever necessary with contractor own supply of paints. Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in-charge. Epoxy paint will be supplied by Railways. Note: The paint and primer should be from M/s Asian paints Co. Ltd., The paints will be primer (IS 5660 of 1970) the aluminum synthetic will be primer (IS 2932 of 1974) brilliant white and yellow painting two coats of enamel paint over one coat of primer. Apparatus case Half size.
Lettering / Numbering Termination particulars, Numbers equipments names etc., legibly and neatly inside location boxes. Half case.
Supply of 6 pin emergency socket box as per Numbers drawing no.SK/CSTE (C) 97/20. (Inspection by Consignee)
Supply of 6 pin emergency socket flat type to Numbers suit light weight 2W/4W portable control telephone as per RDSO specification No.IRS/TC/42/87 with latest amendment. (Inspection by Consignee)
Fabrication and supply of EC assembly complete Numbers with erection of fabricated assembly at location as per Telecom/RE manual, as indicated in the route chart & as directed by Engineer in charge this includes welding of GI pipe for fixing of EC box. SOLAPUR DIVISION-S AND T/CENTRAL RLY
Fixing of EC socket complete with termination of Numbers derivation cable on strip inside the EC box duly mounted on good quality wooden box at SM building/cabin/gate lodge and wherever necessary as per instructions of site incharge of the work.
Supply and installation of concrete (RCC) route Numbers indicators at intervals of 50 meters as per technical specification. They should be standard RCC with letters on one side "CR" and the other side "S&T Cables" as per drawing SK 12/10 of RVNL SC. In case of Telecom quad cable joint locations it shall be painted with RED colour. (Inspection by Consignee)
Execution of S & T work related to Engineering/ Job S&T block of Bridge work or cable shifting or others, for relocation/protection of S&T cable/asset as per Railway site engineer instruction. (Note- five unskilled manpower have to be provided for execution of one job)
Excavation of cable trench as per cable route cum plan,1.0 mtr. deep and 300mm wide along side the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by stones/bricks, clearing of route, bushes etc. The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site. In case depth of trench is not achievable due to site conditions proportionate payment will be made.
Excavation of cable trench as per cable route cum plan,1 mt. deep and 300mm wide along side the track in hard soil, conforming to distances as per cable route plan and refilling. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by stones/bricks,clearing of route,bushes etc.The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site. In case depth of trench is not achievable due to site conditions proportionate payment will be made.
Where ever depth of 0.5 m cable trench is not cum feasible cable shall be protected as under:- Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench.
Cutting of all types of Roads/ platforms cum preparatory to trenching and excavation to depth of 300mmx300mm wide approx. and refilling after laying of RCC/GI /DWC pipe & to restore them to original condition. The work shall be done as per extant practice on C.Rly & instructions of Rly engineer at site. SOLAPUR DIVISION-S AND T/CENTRAL RLY
Horizontal boring of cable duct of minimum 2.0 Metre mtr. depth along with laying of 120 mm HDPE pipe for track crossing with minimum depth reckoned from bottom of the rail/road crossing with minimum depth reckoned from ground level. The work shall be done as per extant pracrice & instructions of site engineer. Preperation of site for Horizontal boring shall be carried out in presence of Railway representative. HDPE pipe will be supplied by Railways. Note_ Contractor shall provide all material required for boring and adequate Nos of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable.
Horizontal boring of cable duct of minimum 2.0 Metre Mtr. depth along with laying of 120mm HDPE pipe for other locations with minimum depth reckoned from ground level. The work shall be done as per extant practice & instructions of site Engineer. Preparation of site for Horizontal boring shall be carried out in presence of Railway Representative. HDPE will be supplied by Railways. Note:- Contractor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. BORING upto the length of 150mtrs. Preparation of site for Horizontal Boring shall be carried out in presence of Railway Representative.
Laying of signalling/Power/Telecom cable of Kilometre various cores/sizes intrenches.
Supply of earth electrode assembly as per Numbers Drg.No. CR/S&T/SK-815. (Inspection by Consignee)
Installation of earth electrode assembly as per Numbers Drg.No.RE/S&T/SIG/Tender/SK726/85 including earth wire connected through GI wire 8 SWG supported on M.S. flat of size 6mm x 40 mm to earth electrode as per drg. No. CR/S&T/SK-815 for sig. Equipment such as lever frames, apparatus case, signals, relay racks, block instruments, and etc. as per RE manual. The earth value should be less than 10 Ohms including the lead wire. The value should be measured in presence of Rly. supervisor. It should be documented and painted on earth enclosure made of concrete.( only earth electrode will be supplied by Railway). All other material required for provision of earthing will be brought by the contractor.
Maintenance RDSO/SPN/197/2008 or latest consisting of: (1) Copper bond steel electrode 3 Mtr long 17 mm dia with copper bonding thickness of min 250 micron & UL listed & marked-01 No. (2) Earth Enhance compound RDSO approved in sealed bag of 10 Kg-03 Nos. (3) Copper strip 150 x 25 x 6 mm-02 Nos. (4) Copper strip 300 x 25 x 6 mm-01 No. (5) 35 Sqmm copper cable to connect earth electrode to MEEB-15 Mtr. approximately. (Inspection by RDSO) SOLAPUR DIVISION-S AND T/CENTRAL RLY
Installation RDSO/SPN/197/Ver 1 or latest, to construct earthing of </= 1 Ohm consisting of: a) Digging the earth to required depth, insertion of electrode, filling of earth enhancing compound & construction of chamber, measurement of earth value and other work of earthing as per code of practice. All the consumables for mounting the copper tape inside the equipment room, exothermic weld material and tools & fixtures for the welding copper tapes and electrodes etc. shall be arranged by the contractor. Total 6074704.12
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Instructions_To_Tenderer_GS.pdf
ATTACHMENT
Special_Conditions_GS.pdf
ATTACHMENT
GCC_with_ACS-10.pdf
ATTACHMENT
Tender_form_Annexure-I.pdf
ATTACHMENT
Cable_cut_policy_CR_1st_Sept_23.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .