At FKM: Balance Electrical work of FKM station in connection with ABSS provision of Platform surfacing, development of circulating area, approach road and toilet in circulating area for passengers in the jurisdiction of SSE/W/FKM.
AP-EL-04-26-27
AP-EL-04-26-27
Open
9 Months
Unknown (Unspecified Location)
₹0
₹2.8 L
19 Jun 2026
19 Jun 2026
29 Jun 2026
A-Provision of Wiring
Supply, installation, testing & commissioning of light point (concealed modular) for to be drawn by single core stranded FRLSH insulated 1.5 mm2, 1100 volt grade copper cable 1 conforming to IS:694 through alkathene pipe of suitable size to be fixed inside wall by having final plastering with necessary coupler /elbow /Tee / 4way etc. The point to be terminated by modular type 6A flush type controlling switch on suitable size full/half flash GI board & platinum white plate at one end and by ceiling rose with 1sqmm single core IS : 694 multi-stranded FRLSH copper wire as earth continuity at the other end as per direction of Railway Engineer.
Supply, installation testing & commissioning of light point (for PP shed) is to be drawn by single core stranded FRLSH insulated 1.5sqmm, 1100 volt grade copper cable conforming to 2 IS:694 through Casing & Capping/ Conduit pipe of suitable size to be fixed necessary coupler /elbow /Tee / 4way etc. The point to be terminated by ceiling rose with 1sqmm single core IS : 694 multi- stranded FRLSH copper wire as earth continuity at the other end as per direction of Railway Engineer.
Supply & fixing of ceiling fan hook for fixing of ceiling fan is to be done as per direction of Railway Engineer.
Supply & fixing of ceiling fan point (concealed modular) is same as item no.1, including supply & fixing of modular type step electronic fan regulator 100W as per direction of Railway Engineer.
Supply & fixing of 6A, 5 pin modular plug point is same as item no-1. The modular plug socket to be fixed with platinum white plate on MS board as per direction of Railway Engineer.
Supply & erection of modular plug point 16A, 3 pin is same as item no.1 except the line shall be drawn by single core stranded FRLSH insulated 2.5sqmm, 1100 volt grade copper cable. 16A, 3 pin socket and 16A separate flush type modular switch to be fixed with platinum white plate on MS board as per direction of Railway Engineer.
Supply & erection of the mobile charging point consisting of 2 sets of 6 amp 3 pin plug socket & switches on 8" X 12" PVC board with suitable size metallic/GI tray to be fixed with the 7 bottom of the board for keeping mobiles during charging. The connection of the mobile charging point is to be done as per SP MCB 6A (as per item no. 10). The point is to be done by single core stranded FRLSH insulated 1.5 mm2, 1100 volt grade copper cable confirming to IS-694 through casing capping/rigid conduit pipe of suitable size to be fixed as per direction of Railway Engineer.
Supply, installation, testing & commissioning of distribution board 6way is to be commissioned as per direction of Railway Engineer. The switch is to be provided on suitable place 8 being observing IE rules & other safety measures. Cable connection to be done by lug /socket of proper size and cable gland to be provided with proper insulation at every cable entrance and exit of distribution board where necessary. The board comprising with C series MCCB/MCB's with the following items: a)MCB DP 20A = 2 no, b)MCB SP 10A = 2 no (For light circuit)
Supply, installation, testing & commissioning of distribution board 4way is to be commissioned as per direction of Railway Engineer. The switch is to be provided on suitable place 9 being observing IE rules & other safety measures. Cable connection to be done by lug /socket of proper size and cable gland to be provided with proper insulation at every cable entrance and exit of distribution board where necessary. The board comprising with C series MCCB/MCB's with the following items: a)MCB DP 20A = 1 no, b)MCB SP 16A =2no (For fan circuit)
Supply & fixing of SP MCB 6A =1 no is to be fixed in proper location as per direction of Railway Engineer. (For mobile charging point).
Supply & fixing of cable PVC loop box of 4way terminal (IP: 66) for suitable entry of 11 cable is to be fixed as per direction of Railway Engineer. For PP shed gland with an appropriate IP rating (IP65, IP66, or higher) to be used as per direction of Railway Engineer. (Necessary petty items required for successful commissioning of loop box is to be supplied by contractor).
B-Provision of wiring cable & LT cable
Supply & laying of FRLSH PVC insulated 2.5sqmm single core multi-stranded copper 12 cable IS:694 to be laid through concealed where necessary of suitable size alkathene pipe/casing capping/conduit pipe including 1sqmm single core FRLSH IS:694 multi stranded copper wire is to be used as per direction of Railway Engineer where necessary.
Supply & laying of FRLSH PVC insulated 4sqmm single core multi-stranded copper 13 cable IS:694 to be laid through concealed where necessary of suitable size alkathene pipe/casing capping/conduit pipe including 1sqmm single core FRLSH IS:694 multi stranded copper wire is to be used as per direction of Railway Engineer where necessary.
Laying of LT cable as per direction of Railway Engineer. (Cable will be procured through store).
Excavation of cable trench for laying of cable with necessary cable protection is to be done as per direction of Railway Engineer.
C-LIGHTING ARRANGEMENT
Supply & fixing of LED surface mounted round/square 15Watt light which is suitable for site condition is to be fixed in proper location as per direction of Railway Engineer.
Supply & fixing of LED recess round/square 15Watt light which is suitable for site condition is to be fixed in proper location as per direction of Railway Engineer
D-Provision of facade lighting
Supply & fixing of Dynamic color changing Linear light fixture of 48watt suitable for outdoor facade lighting applications (RGBW).Luminaries optics shall be highly efficient, UV and temperature-resistant lens systems. Rated input supply of 24V DC Power Factor: >0.9, THD<15%. The luminaire must be controllable through DMX. The body of the fixture must be made of Die-cast 18 aluminum alloy housing with heat resistance tempered glass cover and surface finished- double powder coated, outdoor grade, anti UV with suitable IK07 rating to sustain any outer objects from damaging the fixture. The luminaries must be weatherproof with IP66 or higher rating with operating temperature: 0°C to 50°C and humidity : 10% to 90%. Housing must have adjustable bracket to set the light and illuminate to required area. The entire work is to be executed as per direction of Railway Engineer. Pre-inspection of materials by RITES should be imparted.
Supply & fixing of RGBW DMX controller for light control working temperature -10°C to +50°C is to be provided for controlling of RGBW light. The work is to be executed as per direction of Railway Engineer. Pre-inspection of materials by RITES should be imparted.
Supply & fixing of signal driver is to be provided for communication of light & DMX controller. The work is to be executed as per direction of Railway Engineer.
Supply & fixing of power supply input voltage of AC 85-265V, 50-60Hz. The Output 21 Voltage shall be 24V DC. The Power Consumption of the Power supply unit min 200W to provide power to RGBW light. The work is to be executed as per direction of Railway Engineer. Pre-inspection of materials by RITES should be imparted.
Supply & fixing of digital timer for automatic RGBW light on & off. The work is to be executed as per direction of Railway Engineer.
Supply & fixing of contactor is to be provided as per direction of Railway Engineer.
Supply & fixing of power supply panel box to install signal driver, power supply, adopter and MCB etc. The work is to be executed as per direction of Railway Engineer.
Supply & fixing of power adopter 5V DC for DMX controller power supply is to be done as per direction of Railway Engineer.
Supply & fixing of DP MCB 20A to (up to 63A) is to be fixed in proper location as per direction of Railway Engineer.
Supply & laying of cat 6 UTP PVC -FR (without separator) is to be laid for connection of facade light as per direction of Railway Engineer.
E-DECORATIVE POLE
Supply, Installation, testing and commissioning of drop down LED decorative light, warm white mounted on cast ironbased pole of height 6 meter with 90 watt luminaries capacity single arm bracket mild steel grooved pipe pole made out of cast iron base above the ground level primer coated and painted with polyurethane paint with die cast Aluminum embellishments, joints/ column's section etc. The bottom column shall be integral connection box having mounting arrangement of One No. MCB, 4Way heavy duty connector cover the same etc as required with medium LED Hanging light made out of spun aluminium housing, minimum 5000 lumens with maximum system wattage 90 watt Led Mounting on aluminum die casted heat sink with power Led, minimum efficacy 100 Lumen per watt with external driver CCT 5700, CRI >70, PF>0.90, Surge Protection, Operating Volte 220-240V AC Painted with PU Paint As matching of above Pole complete. The LED driver access should be from top for easy maintenance LEDs should be provided with non- yellowing modular secondary lens optics. LED Used shall be SMD type, Life of fixture 50000hrs, THD<10%, and Operating Temperature Range 0 deg C to +50deg C, IP66. Built in Surge Protection of 5KV & external surge. protection of 10kV. LED Driver should be of Constant current driver to have built-in surge, open & short circuit protection, Over Voltage Protection@ 300V+5V, Double Phase Protection (up to 48 hrs.) The design, drawings, and material specifications must be approved by the competent authority before execution of the work. Pre-inspection of materials by RITES should be imparted.
Supply & fixing of decorative single header is to be fixed in proper location as per direction of Railway Engineer. Pre-inspection of materials by RITES should be imparted.
Supply & fixing of decorative double header is to be fixed in proper location as per direction of Railway Engineer. Pre-inspection of materials by RITES should be imparted.
Supply & fixing of maximum 72W (including all losses) LED Post Top luminaire with Housing made of Spun aluminum & Elegantly designed Aluminum pressure die casted heat sink for efficient thermal management and sturdiness. It should have minimum system lumen output of 8400 lumens with system efficacy of more than 115 lumen/Watt. It should have UV protected pure polyester powder coated grey finish after phosphochromate treatment. The luminaire should have a rated system lifetime of 50,000 burning hours @L70 and CCT of 3000K/5700K. It should have 31 Injection molded, clear polycarbonate cover with IK09 impact resistance rating. The luminaire should have CRI of >= 70. It should have IP66 protection. The luminaire should have PC lens to ensure better uniformity of light distribution. Operating Temperature range should be 0 to 50 deg C and operating voltage should be in the range of 140-270V. It should have Built-In Potted electronic LED driver and surge protection of upto 10KV. System power factor should be >= 0.95 and THD <= 10%. The light source should be towards the ground level for direct lighting. LM 79 report, Type Test Certificate and BIS certificate to be submitted for luminaire and LM 80 report for LED source issued by LED manufacturer. Pre-inspection of materials by RITES should be imparted.
Supply & fixing of high bay light 100 watt, PVC AL housing with direct module IP lens potted driver , 10KV SPD , IP-66 and with system efficacy of 120lm/watt is to be fixed in proper location. Pre-inspection of materials by Railway Engineer should be imparted.
Supply & fixing of chandelier light of appropriate design is to be fixed in proper location as per direction of Railway Engineer.
G-Supply , fabrication, and installation of Non illuminated signage board
TWO WHEELER PARKING.
THREE WHEELER PARKING.
FOUR WHEELER PARKING
DIVYANGJAN PARKING
WAY TO DIVYANGJAN
Station Name Board on gantry (WITH ENTRY LANE & EXIT LANE only), front & back Tri lingual
Emergency Exit.
Reserved Parking for staff (Two Wheeler)
Reserved Parking for staff (Four Wheeler)
General Information Board (Help Line No-139, Wheelchair/Stretcher assistance available with Station Superintendent, Complain Book available with Station Superintendent, Online Complaint-Rail Madad App, First Ald Box available with station superintendent)
Prohibited Items
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC 2022 Works
ATTACHMENT
ShramikKalyanPortal.pdf
ATTACHMENT
Annexure-VA.pdf
ATTACHMENT
TENDERFORMFirstSheetAnnexure-INEW.pdf
ATTACHMENT
BGVerification.pdf
ATTACHMENT
AnnexureVIB.pdf
ATTACHMENT
SCHAP-EL-04-26-27.pdf
ATTACHMENT
GCC2022Correctionslipdtd.14.07.22.pdf
ATTACHMENT
GCCApril2022ACSNo_2.pdf
ATTACHMENT
GCCApril2022ACSNo_3.pdf
ATTACHMENT
GCCPGApril2022AdvanceCorrectionSlipNo_11.pdf Correction sleep for PG
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27.04.221.pdf
ATTACHMENT
GCCPGApril2022AdvanceCorrectionSlipNo_11.pdf
ATTACHMENT
Download all tender documents and submit your bid