Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹29.3 LAccepted-AOC | L-1 | Accepted-AOC lowest bidder | |
| 2 | L-2₹37.2 L+₹7.4 L (24.7%)Rejected-AOC | L-2 | Rejected-AOC other than lowest bidder |
Tender Value
₹29.3 L
EMD Value
₹58,600
Closing Date
13 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh Tanuj Bagla, EE
GE Kaluchak Pin-900673 C/O 56 APO
SPL REPAIR TO LT PANEL, LT CABLE AND CONNECTED ITEMS IN SATA BTY, PROVN OF 24 EXHAUST FAN, ADDN/ALT TO WATER POINT AND PROVN OF CULVERT IN FRONT OF PT GROUND IN KALUCHAK MIL STN UNDER GE KALUCHAK
2023_MES_632700_1
GE/KC/NIT-55/2023-24
Open Tender
Civil Works
Item Rate
180 days
Kaluchak
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹58,600
Yes
27 May 2024
16 Dec 2023
15 Jan 2024
16 Dec 2023
13 Jan 2024
30 Dec 2023
16 Dec 2023 - 23 Dec 2023
Amount
Excavation over areas not exc. 1.50 m deep and getting out in any type soil complete all as specified and directed.
Excavation over areas exc. 1.50 m but not exc. 3.0 m deep and getting out in any type soil complete all as specified and directed.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation etc. or for laying of cable etc. not exc. 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Excavation in trenches not exc. 1.50 m wide and exc. 1.50 m but not exc. 3.00 m in depth for foundation etc. or for laying of cable etc. not exc. 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed.
M&L for dry sand cushioning for UG cable in trenches including spreading levelling and hand paning and consolidating complete all as specified and directed.
Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
M & L for providing reinforced cement concrete 1:2:4 (Nominal Mix) type B-1, using 20 mm graded stone aggregate as in foundation including rafts, footing, foundation beams, plinth beams, base of columns and the like complete all as specified and directed.
M & L for providing reinforced cement concrete 1:2:4 (Nominal Mix) type B-0, using 12.50 mm graded stone aggregate, in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones,bed platesetc and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
M & L for providing reinforced cement concrete 1:2:4 (Nominal Mix) type B-1, using 20 mm graded stone aggregate as in foundation including rafts, footing, foundation beams, plinth beams, base of columns and the like complete all as specified and directed.
M & L for providing reinforced cement concrete 1:2:4 (Nominal Mix) type B-1, using 20 mm graded stone aggregate, as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, shelves and the like complete all as specified and directed.
M & L for providing plain cement concrete type B-1, 1:2:4, (using 20 mm graded stone aggregate), as in copings, bed block for embedding hold fasts, kneelers, apex stones, bed plates, water throughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
M & L for brick work with sub class ‘B’ old size bricks straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:4 complete all as specified and directed.
M & L for form work to sides of concrete foundation, footing, bases of columns, raft & raft beams, sides and soffits (if any) of foundation and plinth beam and similar works in rough finished flat surface of concrete complete all as specified and directed..
M & L for form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc. 200 mm thick horizontal or slopping in fair finished surface of concrete complete all as specified and directed.
M & L for form work to edges of concrete flats, treads, breaks in floor, window cills, concrete railing, opening in concrete wall, sides of RCC slab, RCC / PCC bends in walls or similar work thickness exc. 10 cm and not exc. 20 cm in fair finished surfaces complete all as specified and directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia securing with clips complete all as specified and directed.
M & L for mild steel TMT bars 6 to 8 mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
S & F of steel work as in tubular posts or rectangular hollow section including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to IS – 1239 (Part-I-1990) complete all as specified and directed.
S & F collapsible steel gates, top hung,consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and directed
S & F of steel fasteners of size 75 mm long steel supports fixed to walls complete all as specified and directed.
S & F of Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed . NOTE:- Corrugated shape of sheet shall be approved by GE
M & L for Glazed ceramic coloured tiles in vertical surface 450x300x 7 mm thick , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. NOTE: - RENDERING SHALL BE MEASURED AND PAID SEPARATELY.
M & L for 15 mm thick rendering on fair faces of brick work or concrete surfaces with cement mortar 1:6 finished even and smooth (without using extra cement)complete all as specified and directed.
M & L for preparing newly plastered or previously untreated wall surfaces and applying two coats of cement base paint over one coat of primer complete all as specified and directed.
M & L for preparation of steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
M & L for cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in bed to drain pipes of 450 mm bore including packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed.
S & F of 450 mm bore reinforced concrete pipe class NP-2 laid, jointed with collar in neat cement slurry complete all as specified and directed.
M&L for point wiring one lightl/bell/fan/Exhaust fan point controlled by one way switch(concealed type) complete with multi stranded copper conductor flame retardant low smoke (FRLS) 1.5 Sqmm size PVC insulated unsheathed cable 1100 volts grade drawn through with and incl medium grade duty concealed PVC conduit ISI marked not less than 20mm dia including conduit fittings and accessories such as socket,elbow,junction box, bell mouth,bend, reducer etc complete incl cutting chases in existing walls of any description built in cement mortar and making good the disturbed surfaces in cement mortar (1:4) and finishing the surfaces to match with existing surfaces and finish with using sunken type pressed steel terminal boxes of required sizes of not less than 1.6 mm thick factory made and factory painted with top cover of 3 mm thick plastic laminated sheet fixed with brass screws washers with all accessories including single core multi stranded copper conductor 1.5 Sqmm size PVC insulated unsheathed cable green in colour as earth wire to common earth and connected to earth dolly drawn in same conduit complete all as specified . NOTE :-Wire/Cable colour coding Shall be maintained properly as per IE rule.
S&F switch piano flush type polycarbonate single pole one way 5 Amps complete all as specified and directed.
S&F Ceiling rose three teminal /PVC/ polycarbonate, insulated body complete all as specified and directed.
Supply & fixing metallic exhaust fan, 300mm (12") sweep, single phase, 230 volts, 50 Hz AC, 1400 RPM, energy saving, heavy duty totally enclosed, heavy duty motor with die-cast aluminiun rotor mounted on two ball bearings, complete with louvers and shutters, connecting electrically using 3 core 0.75 Sq mm PVC insulated flexible copper conductor cable including cutting holes in existing brick walls for making opening for fixing of exhaust fan of 300mm sweep including grounting bolts/nuts and making good disturbed surface of walls using cement sand mortar 1:4, complete all as specified & directed.
M&L for well burnt brick with sub class ‘B’ old size bricks for protection of cable complete all as specified and directed.
Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15mm thick CRCA sheet for load bearing members and 16 SWG (1.6 mm thick) for doors covers and internal partitions and shall be powder coated both side. Base frame of the panel shall be made of ICMC channel of size 50 x50 x 6mm, duly grouted on platform made of brick work in CM (1:2:4), 15mm thick plastering in CM (1:6) having minimum height of 600mm. The panel shall be provided with separate compartments for each switch gears with hinged door including interlocking with switch gears. The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with epoxy insulated 600 Amps rated high conductivity aluminium bus bars, supported with DMC / SMC barriers and coluor coded, prewired with copper cable, 1100V Danger notice board on front of the panel & the degree of protection is IP-54. the panel shall be complete with instrumentation such as LED phase indicating lamps and CT's, including extended aluminium strip of rating of Incomer (600Amps), and outgoing as per rating of MCCB’s, including aluminium lugs to connect the cable etc., and comprising of the following:- (for 315 KVA Transformer OTM Sata)
(a) MCCB 500 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 36KA (Adjustable thermal & fixed magnetic release) - 01 Nos (Incomer) (b) MCCB 250 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 36 KA (Adjustable thermal & magnetic release) - 01 Nos (outgoing) (c) MCCB 160 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 36 KA (Adjustable thermal & magnetic release) - 05 Nos (outgoing) (1 No Spare) (d) MCCB 100 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 16 KA (Adjustable thermal & magnetic release) - 01 Nos (outgoing) (e) Multifunctional meter ---01 Nos (f) Indicator lamp RYB :01 Set (g) CT'S 500/5 01 Set NOTE : 1) Design / Drawing / BOM of the panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from GE before placing final order to the manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.
Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15mm thick CRCA sheet for load bearing members and 16 SWG (1.6 mm thick) for doors covers and internal partitions and shall be powder coated both side. Base frame of the panel shall be made of ICMC channel of size 50 x50 x 6mm, duly grouted on platform made of brick work in CM (1:2:4), 15mm thick plastering in CM (1:6) having minimum height of 600mm. The panel shall be provided with separate compartments for each switch gears with hinged door including interlocking with switch gears. The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with epoxy insulated 400 Amps rated high conductivity aluminium bus bars, supported with DMC / SMC barriers and coluor coded, prewired with copper cable, 1100V Danger notice board on front of the panel & the degree of protection is IP-54. the panel shall be complete with instrumentation such as LED phase indicating lamps and CT's, including extended aluminium strip of rating of Incomer (400Amps), and outgoing as per rating of MCCB’s, including aluminium lugs to connect the cable etc., and comprising of the following:- (for 160 KVA Transformer near Bde Canteen)
(a) MCCB 350 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 36KA (Adjustable thermal & fixed magnetic release) - 01 Nos (Incomer) (b) MCCB 200 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 36 KA (Adjustable thermal & magnetic release) - 02 Nos (outgoing) (c) MCCB 160 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 36 KA (Adjustable thermal & magnetic release) - 02 Nos (outgoing) (d) MCCB 100 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 16 KA (Adjustable thermal & magnetic release) - 02 Nos (outgoing)(1 No Spare) (e) Multifunctional meter ---01 Nos (f) Indicator lamp RYB :01 Set (g) CT'S 350/5 01 Set NOTE : 1) Design / Drawing / BOM of the panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from GE before placing final order to the manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.
Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15mm thick CRCA sheet for load bearing members and 16 SWG (1.6 mm thick) for doors covers and internal partitions and shall be powder coated both side. Base frame of the panel shall be made of ICMC channel of size 50 x50 x 6mm, duly grouted on platform made of brick work in CM (1:2:4), 15mm thick plastering in CM (1:6) having minimum height of 600mm. The panel shall be provided with separate compartments for each switch gears with hinged door including interlocking with switch gears. The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with epoxy insulated 350 Amps rated high conductivity aluminium bus bars, supported with DMC / SMC barriers and coluor coded, prewired with copper cable, 1100V Danger notice board on front of the panel & the degree of protection is IP-54. the panel shall be complete with instrumentation such as LED phase indicating lamps and CT's, including extended aluminium strip of rating of Incomer (350Amps), and outgoing as per rating of MCCB’s, including aluminium lugs to connect the cable etc., and comprising of the following:- ( Golconda line Md Accn & Near Offrs Mess)
(a) MCCB 250 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 36KA (Adjustable thermal & fixed magnetic release) - 01 Nos (Incomer) (b) MCCB 160 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 36 KA (Adjustable thermal & magnetic release) - 02 Nos (outgoing) (c) MCCB 100 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 16 KA (Adjustable thermal & magnetic release) - 02 Nos (outgoing) (d) MCCB 63 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 16 KA (Adjustable thermal & magnetic release) - 01 Nos (outgoing) (e) Multifunctional meter ---01 Nos (f) Indicator lamp RYB :01 Set (g) CT'S 250/5 01 Set NOTE : 1) Design / Drawing / BOM of the panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from GE before placing final order to the manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.
Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15mm thick CRCA sheet for load bearing members and 16 SWG (1.6 mm thick) for doors covers and internal partitions and shall be powder coated both side. Base frame of the panel shall be made of ICMC channel of size 50 x50 x 6mm, duly grouted on platform made of brick work in CM (1:2:4), 15mm thick plastering in CM (1:6) having minimum height of 600mm. The panel shall be provided with separate compartments for each switch gears with hinged door including interlocking with switch gears. The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with epoxy insulated 300 Amps rated high conductivity aluminium bus bars, supported with DMC / SMC barriers and coluor coded, prewired with copper cable,1100V Danger notice board on front of the panel & the degree of protection is IP-54. the panel shall be complete with instrumentation such as LED phase indicating lamps and CT's, including extended aluminium strip of rating of Incomer (300Amps), and outgoing as per rating of MCCB’s, including aluminium lugs to connect the cable etc., and comprising of the following:-
(a) MCCB 200 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 36KA (Adjustable thermal & fixed magnetic release) - 01 Nos (Incomer) (b) MCCB 63 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 16 KA (Adjustable thermal & magnetic release) - 05 Nos (outgoing) (c) MCB 63 amps, 2 pole, 415V, 50Hz, AC Supply with breaking capacity 10 KA (Adjustable thermal & magnetic release) - 02 Nos (outgoing) (d) Multifunctional meter ---01 Nos (e) Indicator lamp RYB :01 Set (f) CT'S 200/5 01 Set
NOTE : 1) Design / Drawing / BOM of the panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from GE before placing final order to the manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.
Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15mm thick CRCA sheet for load bearing members and 16 SWG (1.6 mm thick) for doors covers and internal partitions and shall be powder coated both side. Base frame of the panel shall be made of ICMC channel of size 50 x50 x 6mm, duly grouted on platform made of brick work in CM (1:2:4), 15mm thick plastering in CM (1:6) having minimum height of 600mm. The panel shall be provided with separate compartments for each switch gears with hinged door including interlocking with switch gears. The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with epoxy insulated 250 Amps rated high conductivity aluminium bus bars, supported with DMC / SMC barriers and coluor coded, prewired with copper cable, 1100V Danger notice board on front of the panel & the degree of protection is IP-54. the panel shall be complete with instrumentation such as LED phase indicating lamps and CT's, including extended aluminium strip of rating of Incomer (250Amps), and outgoing as per rating of MCCB’s, including aluminium lugs to connect the cable etc., and comprising of the following:-
(a) MCCB 160 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 36KA (Adjustable thermal & fixed magnetic release) - 01 Nos (Incomer) (b) MCCB 100 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 16 KA (Adjustable thermal & magnetic release) - 02 Nos (outgoing) (c) MCCB 63 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 16 KA (Adjustable thermal & magnetic release) - 01 Nos (outgoing) (d) MCB 63 amps, 2 pole, 415V, 50Hz, AC Supply with breaking capacity 10 KA (Adjustable thermal & magnetic release) - 01 Nos (outgoing) (e) Multifunctional meter ---01 Nos (f) Indicator lamp RYB :01 Set (g) CT'S 200/5 01 Set
NOTE : 1) Design / Drawing / BOM of the panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from GE before placing final order to the manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.
Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15mm thick CRCA sheet for load bearing members and 16 SWG (1.6 mm thick) for doors covers and internal partitions and shall be powder coated both side. Base frame of the panel shall be made of ICMC channel of size 50 x50 x 6mm, duly grouted on platform made of brick work in CM (1:2:4), 15mm thick plastering in CM (1:6) having minimum height of 600mm. The panel shall be provided with separate compartments for each switch gears with hinged door including interlocking with switch gears. The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with epoxy insulated 250 Amps rated high conductivity aluminium bus bars, supported with DMC / SMC barriers and coluor coded, prewired with copper cable, 1100V Danger notice board on front of the panel & the degree of protection is IP-54. the panel shall be complete with instrumentation such as LED phase indicating lamps and CT's, including extended aluminium strip of rating of Incomer (250Amps), and outgoing as per rating of MCCB’s, including aluminium lugs to connect the cable etc., and comprising of the following:-
(a) MCCB 160 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 36KA (Adjustable thermal & fixed magnetic release) - 01 Nos (Incomer) (b) MCCB 100 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 16 KA (Adjustable thermal & magnetic release) - 01 Nos (outgoing) (c) MCCB 63 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 16 KA (Adjustable thermal & magnetic release) - 02 Nos (outgoing) (d) MCB 63 amps, 2 pole, 415V, 50Hz, AC Supply with breaking capacity 10 KA (Adjustable thermal & magnetic release) - 02 Nos (outgoing) (e) Multifunctional meter ---01 Nos (f) Indicator lamp RYB :01 Set (g) CT'S 200/5 01 Set NOTE : 1) Design / Drawing / BOM of the panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from GE before placing final order to the manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.
Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15mm thick CRCA sheet for load bearing members and 16 SWG (1.6 mm thick) for doors covers and internal partitions and shall be powder coated both side. Base frame of the panel shall be made of ICMC channel of size 50 x50 x 6mm, duly grouted on platform made of brick work in CM (1:2:4), 15mm thick plastering in CM (1:6) having minimum height of 600mm. The panel shall be provided with separate compartments for each switch gears with hinged door including interlocking with switch gears. The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with epoxy insulated 200 Amps rated high conductivity aluminium bus bars, supported with DMC / SMC barriers and coluor coded, prewired with copper cable, 1100V Danger notice board on front of the panel & the degree of protection is IP-54. the panel shall be complete with instrumentation such as LED phase indicating lamps and CT's, including extended aluminium strip of rating of Incomer (200Amps), and outgoing as per rating of MCCB’s, including aluminium lugs to connect the cable etc., and comprising of the following:-
(a) MCCB 100 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 16KA (Adjustable thermal & fixed magnetic release) - 01 Nos (Incomer) (b) MCCB 63 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 16 KA (Adjustable thermal & magnetic release) - 02 Nos (outgoing) (c) MCB 63 amps, 2 pole, 415V, 50Hz, AC Supply with breaking capacity 10 KA (Adjustable thermal & magnetic release) - 01 Nos (outgoing) (d) MCB 32 amps, 2 pole, 415V, 50Hz, AC Supply with breaking capacity 10 KA (Adjustable thermal & magnetic release) - 02 Nos (outgoing) (e) Multifunctional meter ---01 Nos (f) Indicator lamp RYB :01 Set (g) CT'S 125/5 01 Set NOTE : 1) Design / Drawing / BOM of the panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from GE before placing final order to the manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.
Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15mm thick CRCA sheet for load bearing members and 16 SWG (1.6 mm thick) for doors covers and internal partitions and shall be powder coated both side. Base frame of the panel shall be made of ICMC channel of size 50 x50 x 6mm, duly grouted on platform made of brick work in CM (1:2:4), 15mm thick plastering in CM (1:6) having minimum height of 600mm. The panel shall be provided with separate compartments for each switch gears with hinged door including interlocking with switch gears. The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with epoxy insulated 350 Amps rated high conductivity aluminium bus bars, supported with DMC / SMC barriers and coluor coded, prewired with copper cable, 1100V Danger notice board on front of the panel & the degree of protection is IP-54. the panel shall be complete with instrumentation such as LED phase indicating lamps and CT's, including extended aluminium strip of rating of Incomer (350Amps), and outgoing as per rating of MCCB’s, including aluminium lugs to connect the cable etc., and comprising of the following:-
(a) MCCB 200 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 36KA (Adjustable thermal & fixed magnetic release) - 01 Nos (Incomer) (b) Multifunctional meter ---01 Nos (c) Indicator lamp RYB :01 Set (d) CT'S 200/5 01 Set NOTE : 1) Design / Drawing / BOM of the panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from GE before placing final order to the manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.
Dismantling LT Panel board of any size from site complete all as specified and as directed.
Dismantling ACSR conductor of any size from LT pole and setting a side the serviceable quantity for reuse and removing the unserviceable quantity from site complete all as specified and as directed.
M&L under ground XLPE insulated, screened, PVC bedded galvanized steel strip or wire armored, electric power cable (heavy duty) with aluminium conductor, 1100 volts (earthed) grade cross sectional area 300 sqmm, 3.5 core laid in trenches/ pipes/ ducts/ wall/ boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including disconnecting and taking out of existing LT cable of any type and size complete all as specified and directed. Note:- Excavation and earth, sand coushioning and protection for cable work shall be measured and paid separately.
All as per item No. 44 here-in-before but cross-sectional area 185 sqmm, 3.5 core complete.
All as per item No. 44 here-in-before but cross-sectional area 150 sqmm, 3.5 core complete.
All as per item No. 44 here-in-before but cross-sectional area 120 sqmm, 3.5 core complete.
All as per item No. 44 here-in-before but cross-sectional area 95 sqmm, 3.5 core complete.
All as per item No. 44 here-in-before but cross-sectional area 70 sqmm, 3.5 core complete.
All as per item No. 44 here-in-before but cross-sectional area 50 sqmm, 3.5 core complete.
All as per item No. 44 here-in-before but cross-sectional area 35 sqmm, 3.5 core complete.
All as per item No. 44 here-in-before but cross-sectional area 25 sqmm, 3.5 core complete.
All as per item No. 44 here-in-before but cross-sectional area 16 sqmm, 4 core complete.
All as per item No. 44 here-in-before but cross-sectional area 16 sqmm, 2 core complete.
M&L for GI pipe 80 mm dia "light grade" ISI marked, laid in trenches/ on floors/road for cable protection including necessary joints / fittings complete all as specified and directed .
All as per Srl item No 55 here-in-before but 50mm dia
All as per Srl item No 55 here-in-before but 40mm dia
Boring of holes under road, pavement, hard standing by hand method without damaging the surface for 80/50/40 mm bore GI pipe complete all as specified and as directed by Engineer-in-Charge. Note :-(i) Depth of hole shall be 1 metre below the top surface of road / pavement / hard standing. (ii) Pipe shall be measured and paid for separetely under respective item of this schedule.
Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x 600mm x 6mm thick buried dirctly in ground with earth pit not lesss than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized iron strip of 25 x 4 mm earthing lead by means of nuts bolts check nuts GI washers earth wire protected by GI pipe 32 mm bore, light grade, including concrete pit in PCC (1:3:6) type C1 of size 45x45x45 cm, precast RCC (1:2:4) type B1 as cover of size 40x40x10 cm with one handle for lifting made out of 8 mm dia MS bar, GI funnel wire mesh, 20 mm bore GI pipe, medium grade, for watering, charcoal or coke and salt packed all around in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part-I including testing on completion including demolition to existing one complete all as specifed and directed. (Note :- (i) PCC pit, RCC pit cover, GI earth protection & watering pipe, funnel, earth strip upto 7.5 Mtr etc shall deemed to be included in the unit rate. (ii) GI earth strip above 7.5 m length, if required, for earthing shall be paid measured and seperately as "Supply only".)
DARVESH ENGINEERING WORKS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .