GE PULGAON
GE PULGAON CAD CAMP PULGAON 442303
REPAIRS/REPLACEMENT OF STREET LIGHT APFC PANEL AND OTHER MISC WORKS AT GUNJKHEDA, CMPH, BHIM LINE AND RA AREA UNDER GE PULGAON
2023_MES_612985_1
8048/PUL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE PULGAON
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE PULGAON
₹50,000
Yes
15 Sept 2023
9 Aug 2023
4 Sept 2023
9 Aug 2023
29 Aug 2023
24 Aug 2023
10 Aug 2023 - 23 Aug 2023
Amount
Disconnecting and taking down exiting unserviceable Street lights/flood lights any type/watts from pole/wall and dismantling the light fittings. Repairing/replacing unserviceable parts refixing the same on pole/wall after testing and removing of carbon from line jumpers/Tightening of jumper/alligment of fitting defective street light/security light/flood lights fitting/LED light from electric pole complete all as directed by Engr-In-Charge Note: Spare parts and accessories such as LED Driver,connected items etc will be measured and paid separately under respective item as supply only and fixing is deemed to be included under this item.
Supply and fixing in replacement LED street light Driver in repair for 100 Watts LED Flood light complete all as specified and directed.
Supply and fixing in replacement LED street light Driver in repair for 60 Watts LED Street light/ Flood light type complete all as specified and directed.
Supply and fixing in repair LED streetlight of 45 Watt comprises of pressure die cast Aluminium housing & having system efficiency>110 lumens/Watt i.e 6670 lumns,All LEDs should be highpower LEDs of 1W to 3W Only with moduler lens for batwin shape distribution of 30 degree & 60 degree,Input voltage working range is 140 Vac to 270 Vac,Brand name should be emoboised,Potted Driver is used with 4KV internal & external 5KV Potted surge protection,Short Circuit Protection,Open Circuit Protection,High & low voltage protection,fixture should withstand high & low voltage protection,fixture should withstand high voltage upto440 v for 8 hr,IP66 Protected,THD<10%,CRI>70CCT 5700+/-300K, PF>0.9, Driver efficiency>85%,LM79.Including taking down old unserviceable fittings complete all as specified and directed by Engr-in-Charge. Make : Crompton Greaves cat part No TRP-417-45-57-SL-LM-NBK or equivalent make in Wipro/Phillips/ Havells
Supply and fixing in repair LED streetlight of 60 Watt comprises of pressure die cast Aluminium housing & having system efficiency>110 lumens/Watt i.e 6670 lumns,All LEDs should be highpower LEDs of 1W to 3W Only with moduler lens for batwin shape distribution of 30 degree & 60 degree,Input voltage working range is 140 Vac to 270 Vac,Brand name should be emoboised,Potted Driver is used with 4KV internal & external 5KV Potted surge protection,Short Circuit Protection,Open Circuit Protection,High & low voltage protection,fixture should withstand high & low voltage protection,fixture should withstand high voltage upto440 v for 8 hr,IP66 Protected,THD<10%,CRI>70CCT 5700+/-300K, PF>0.9, Driver efficiency>85%,LM79.Including taking down old unserviceable fittings complete all as specified and directed by Engr-in-Charge. Make : Crompton Greaves cat part No TRP-409-60-57-SL-GL-NSG or equivalent make in Wipro/Phillips/ Havells
Supply and fixing in repair LED flood light 100 watt 230 V AC, 3000K outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including taking down old unserviceable fittings complete all as directed by EIC. Make : Crompton cat part No TFS-504-100-57-NL-SL-GL-NSG or equivalent make in Wipro/Phillips /Havells
Supply and fixing in repair 1100 volts grade 4 Sqmm twin core flat heavy duty cable PVC insulated,PVC sheet with aluminium conductors, multistranded served with an inner sheathing of PVC tape and overall PVC shathed for street lights connections in service connections. including disconnection and removing the unserviceable cable.
Supply and fixing in repair 1100 volts grade 6 Sqmm twin core flat heavy duty cable PVC insulated,PVC sheet with aluminium conductors, multistranded served with an inner sheathing of PVC tape and overall PVC shathed in service connections
Supply and fixing in repair street light bracket made out of 25mm dia light grade pipe 1.2 mtr long bend to shape along with two FI clamp made out of 20mmx3mm including nut, bolt, washers including painting of one coat primer and two coat of aluminium synthetic enamel paint all as directed and taking down the existing bracket.
Material and Labour Earthing complete with galvanised earth plate electrode 60cmx60cmx6.3 mm thick buried directly in ground nut less then 2.25 mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nut check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to main switch distribution board complete and testing on completion all as specified and directed by Engr-in-charge. Note : The unit rate shall also includes for excavation and earth work, in/any type of soil, pit in PCC 1:3:6 type C1 funnel with watering pipe 20mm bore GI medium grade, earth lead protection pipe 40mm bore GI medium grade, RCC 1:2:4 type B1 cover for earrth chamber, 50mm thick with 8mm dia TMT bar 150mm C/C both ways & 6mm dia MS round bars as handles of cover slab all as specified.
Material and labour in replacement/repair for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI strip 32mm X 6mm main earthing lead by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (2009) connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt alround earth plate, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) 50mm thick cover reinforced with 8mm dia TMT bars @ 100mm c/c both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm bore GI medium grade earth lead protection pipe, complete all as specified and directed.
Supply and fixing in replacement of galvanised iron strip 32 X 6 mm buried in ground for additional earthing lead beyond 7.5 meter if required.
Supply & Fixing in repair steel tubing GI light grade 50mm bore for cable protection passing under Road/Floor or for fixing to poles all as specified and directed.
All as per item above but for 40 mm dia GI Pipe complete all as specified and as directed
Material and Labour for Preparation of old painted surfaces of steel tubular poles 9/11 Mtr long including cross arms protection pipe by rubbing propperly with the help of embry/sand paper and painting one coat of aluminium paint from above ground level to top of pole and cross arms and protection pipe Engr-in-charge paint including writing poles numbers in white letter on black ground or as directed complete. all as specified and directed by Engr-in-Charge.
Taking out LT XLPE/PVC insulated armoured cable alongwith all joints of any size from trenches wall/roof/trenches including bricks/PCC Covers complete all as directed by Engr-in-Chrage.
Supply and laying XLPE LT 1100 volts underground earthed cable, PVC bedded, galvanized steel strip or wire armoured, electric power cable heavy duty 1100V with multi stranded, aluminum conductor of cross sectional area 2 core x 10 Sqmm including laying, testing and commissioning complete all as specified and directed.
Supply and laying XLPE LT 1100 volts underground earthed cable, PVC bedded, galvanized steel strip or wire armoured, electric power cable heavy duty 1100V with multi stranded, aluminum conductor of cross sectional area 2 core x 16 Sqmm including laying, testing and commissioning complete all as specified and directed.
Supply and laying XLPE LT 1100 volts underground earthed cable, PVC bedded, galvanized steel strip or wire armoured, electric power cable heavy duty 1100V with multi stranded, aluminum conductor of cross sectional area 4 core x 10 Sqmm including laying, testing and commissioning complete all as specified and directed.
Supply and laying XLPE LT 1100 volts underground earthed cable, PVC bedded, galvanized steel strip or wire armoured, electric power cable heavy duty 1100V with multi stranded, aluminum conductor of cross sectional area 4 core x 16 Sqmm including laying, testing and commissioning complete all as specified and directed.
Excavation in trenches not exceeding 1.5 metre wide & not exceeding 1.5 meter in depth for foundation, laying of cable or pipe and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed by Engr-in-charge.
Returning, filling in trenches in soft/loose soil in layers n.exc. 25 cm after laying of cables including spreading, levelling, watering, and well ramming complete all as directed by Engr-in-Chrage.
Removing surplus excavated soil to a distance n.exc. 50 metre and depositing where directed at a level n.exc.1.5 metre high from the starting point all as directed by Engr-in-Chrage.
Material and Labour for sand cushioning with dry and clean sand over and under the under ground cable in trenches ,ducts for cable protection incliding levellling and consodilation complete all as specified and directed by EIC. Note : Punned thickness shall be measured.
Laying only old brick/PCC cover obtained from excavation complete as directed by Engr-in-Charge
Supply and laying brick sub class "B" having minimu compressive strength 75 kg/sqcm laid in trenches for cable protection etc complete all as directed by Engr-in-Chrage.
Supply and fixing in repair loop in / loop out box of internal size 250 x 210 x 115mm made out of FRP (Hot moulded type) with weather proof canopy and locking screws alongwith 5/6 Amps MCB-01 No, 15 Amps rated 3 pole connector - 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector complete in the box, duly fixed to steel tubular pole using 25 x 3mm FI clamp with suitable gland and lugs for connecting cable including taking down old one complete all as specified and as directed.
Supply and fixing in repair MCB TPN 63 amps 415 volts Complete all as specified and directed including taking out old one.
Supply and fixing in repair MCB SPN 32 amps 230 volts Complete all as specified and directed including taking out old one.
Material an Labour for road cutting for laying of UG cable under road/railway crossing, pavement, hardstanding by manually means, protection pipe for cable protection GI pipe for cable of required dia and making it good to match with the adjoining surface/structue for after cable passing completed asll as specified and directed
Supply & Fixing in repair/Replacement PVC line seperator suitable for 2/3/4 way on LT over head line all as directed.
Supply, errecting and fixing in true vertical position, steel tubular swaged pole (410 SP-55) confirming to IS 2713(Part 1 to 3) 11 mtr complete with cast iron base plate, pole cap/finial taper plug, bolts,nuts, washers including two coats of black bituminious paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coate of red oxide primer and two coats of aluminium paint complete all as specified and directed. Note: Excation, earth work and PCC foundation will be measured and paid separately.
M&L for PCC 1:4:8 type D-2 using 40 mm (using graded crushed stone aggregate ) as in foundation filling and mass concrete of stay assembly/ pole etc complete all as specified and as directed.
M&L for PCC(1:2:4) type B-1( using 20mm graded crushed stone aggregate) as in coping foundation,filling and mass concrete including frame work for poles complete all as specified and directed
Material and Labour for disconnecting burnt end or portion of HT/LT cable from pole/AB Switch/OH Lines/GOD/Transformer and removing from GI pipe/loop including all GI clamps,nut bolts washers etc including necessary excavation & earth work relaying and reconnecting the cable by removing burnt portion of cable and preparing fresh terminals/HT /LT Joints including re- fixing of new lugs for 16 Sqmm 3.5/ 4 to 120 Sqmm cable complete all as specified and directed. Note : Cable joint will be measured and paid separately in the respective items.
Material and Labour for taking out HT/LT Poles through cutting/welding or & breaking of concrete foundation encasing the pole through excavtion without damaging and making good to the diturbed place as around after disconnecting all Cross Arms/Earthing GI Strips./Angle/AB Switch/LA/GOD/Pin/Disc insulators from and re-fixing or deposite in MES yard. complete all as specified and directed. Note : Cable joint will be measured and paid separately in the respective items.
Material and labour for straight through joint for LT Cable 1100 Volts grade epoxy/ XLPE type of size 25-35 Sqmm 3.5 Core /4 Core Sqmm including taking out/separating the faulty portion of the cable,preparing it for fixing of joint and testing on full load after repair all as directed by Engr-in-Charge.
All as per item Sr No 37 but 3.5 core x 50 sqmm.
All as per item Sr No 37 but 3.5 core x 70 sqmm.
All as per item Sr No 37 but 3.5 core x 95 sqmm.
All as per item Sr No 37 but 3.5 core x 120 to 150 sqmm.
Dismantaling of the complete APFC of any capacity from its position, opening for repair, preventive maintenance, servicing, including wiring, replacement of defective parts to make it fully functional, reassembling after repair, installation to its original position, connection with input/output supply, testing to its on full load capacity complete all as specified and as directed. NOTE :- (a) Spares / parts except minor repairs required for replacement shall be measured and paid separately. (b) Necessary wiring with 1.5 Sqmm Single Core FRLS included in the above Cost.
Supply and fixing in replacement of old defective Power Contactor MOC-15, 3 pole 415 Volts capacity 15 amps AC 50 Hz (for switching of capacitor) all as specified and testing after competion..
Supply and fixing in replacement of old defective Power Contactor MOC-5, 3 pole 415 Volts capacity 5 amps AC 50 Hz (for switching of capacitor) all as specified and testing after competion..
Supply and fixing in replacement of old defective 10 KVAR Heavy duty Power Capacitor 440 Volt, in APFC Panel all as specified and testing after competion..
Supply and fixing in replacement of old defective 5 KVAR Heavy duty Power Capacitor 440 Volt, in APFC Panel all as specified and testing after competion..
Supply and fixing in replacement of old defective 3 KVAR Heavy duty Power Capacitor 440 Volt, in APFC Panel all as specified and testing after competion..
Supply and fixing in replacement of old defective 2 KVAR Heavy duty Power Capacitor 440 Volt, in APFC Panel all as specified and testing after competion...
Supply and fixing in replacement of old defective 1 KVAR Heavy duty Power Capacitor 440 Volt, in APFC Panel all as specified and testing after competion...
Supply and fixing in replacement of old defective CT of 100/5 ratio as specified in existing APFC Panel
Supply and fixing in replacement of old defective APFC relay 8 stage including adon For APFC Panel.
Supply and fixing in replacement of old defective APFC relay 6 stage including adon For APFC Panel.
Supply and fixing in replacement of old defective MCB 3 pole 16 Amps 440 Volts all as specified and directed.
Supply and fixing in replacement of old defective MCB 3 pole 10 Amps 440 Volts all as specified and directed. Make :-Havell's/L&T
Supply and fixing in replacement of old defective MCB TP 32 Amps 23 Volts coplete all as specified and directed. Make :- L&T/INDOASIAN/GE/C&s/Schnider
Supply and fixing in replacement of old defective flexible copper cable PVC insulated multi stranded of size 3 core 2.5 Sqmm 1100 Volts grade.
Supply and fixing in replacement of old defective flexible copper cable PVC insulated multi stranded of size 3 core 4 Sqmm 1100 Volts
Supply and fixing in replacement of old defective Digital Voltmeter (0-500 V) all as specified and directed.
Supply and fixing in replacement of old defective Digital Amp Meter (0-100 A) all as specified and directed.
Supply and fixing in replacement of old defective Indicating LED Light Red 220 V AC all as specified and directed.
Supply and fixing in replacement of old defective Indicating LED Light Yellow 220 V AC all as specified and directed.
Supply and fixing in replacement of old defective Indicating LED Light Green 220 V AC all as specified and directed.
Repair/Replacement of Automatic Street light Control Switch using Infrared Sensor based Nature Switch for automatic switching of street lights. Nature Switch operation should be based on Natural light Lux level.Required illumunance Level for Switching ON is<30 Lux and for Switching OFF >10 lUX.The sensor should also have part night operation facility of min .4 hrs to max.12 hrs .The sensor along with suitable power Contactor(s) and Incoming-Outgoing MCBs should be enclosed in a pole/wall mountable Rust proof,Electric shock proof,Termite proof and FR grade thermoplastic polycarbonate Enclosure with hinged Enclosure conforming to IP-66 protection class 2. The Circuit should also have provision for Manual Operation(i.e sensor By -pass option).Two-phase load of 2x8 kw (Swadeep-66-16 kw 3P) with Contactor,Incoming MCB & Outgoing MCB rating of 40-63 Amps & Main load Circuit Wiring(Copper) of min.16 sq .mm with two nos Contactors,two nos.Incoming MCBs & 2 nos.Outgoing MCBs of 40-63 Amps each & Circuit wiring (Copper) of min.10 sq.mm.
Repair/Replacement of Automatic Street light Control Switch using Infrared Sensor based Nature Switch for automatic switching of street lights. Nature Switch operation should be based on Natural light Lux level.Required illumunance Level for Switching ON is<30 Lux and for Switching OFF >10 lUX.The sensor should also have part night operation facility of min .4 hrs to max.12 hrs .The sensor along with suitable power Contactor(s) and Incoming-Outgoing MCBs should be enclosed in a pole/wall mountable Rust proof,Electric shock proof,Termite proof and FR grade thermoplastic polycarbonate Enclosure conforming to IP66 protection class 2. The Circuit should also have provision for Manual Operation(i.e sensor By -pass option) Single-phase load of 8 kw(Swadeep-66-8kw 1P) with Contactor,Incoming MCB & Outgoing MCB rating of 40-63 Amps & Main load Circuit Wiring(Copper) of min.16 sq .mm
M/S Maa Durga Constructions,Pulgaon
SHRI RANI SATI TRADERS
M/s MM TRADERS
M/S JAI BHAWANI CONSTRUCTIONS
Bidder Name
SHRI RANI SATI TRADERS
M/S Maa Durga Constructions,Pulgaon
M/s MM TRADERS
M/S JAI BHAWANI CONSTRUCTIONS
SHUBHAM SALES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .