Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC NO 2 22 DHARMA RAJA KOIL STREET PULICAT POST PONNERI TALUK TIRUVALLUR DISTRICT 601205 | THIRUVALLUR | TAMIL NADU | 601205 | ₹1.3 Cr Quoted ₹1.4 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹1.4 Cr+₹4.0 L (2.88%)Rejected-Finance | ₹1.4 Cr+₹4.0 L (2.88%) | L2 | Rejected-Finance Rejected |
| 3 | L3₹1.5 Cr+₹8.8 L (6.31%)Rejected-Finance NO 07 CENTRAL STREET KILPAUK GARDEN COLONY CHENNAI 600010 | CHENNAI | TAMIL NADU | 600010 | ₹1.5 Cr+₹8.8 L (6.31%) | L3 | Rejected-Finance Rejected |
Tender Value
₹1.4 Cr
EMD Value
₹77,750
Closing Date
27 Mar 2025, 3:00 pmClosed
Chief Engineer
Fishing Harbour Project Circle Fisheries and Fishermen Welfare Department Chennai35
Development of Climate resilient coastal fishermen village at Mandavai Pudhukuppam in Villupuram District.
2025_AHDF_531900_1
14 DB F.114 N 2025 Dated 06.03.2025
Open Tender
Civil Works
Lump-sum
180 days
Mandavai Pudhukuppam
As per mentioned below
3 documents required · 3 mandatory
₹0
₹77,750
29 May 2025
13 Mar 2025
28 Mar 2025
13 Mar 2025
27 Mar 2025
13 Mar 2025
Amount
Earthwork Excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth with in the compound in places shown by the departmental officers with an initial lead of 10mts and initial lift of 2mts and clearing and levelling the site etc., Complete complying with standard specifications.
Refilling basement with excavated earth in layers of not more than 15cm thick well rammed, watered and consolidated etc.,
Supplying and filling in foundation, basement, etc with filling M.sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
Cement Concrete 1:4:8 (One cement, Four sand and Eight hard broken stone) using 40 mm gauge hard broken jelly for flooring including laying, consolidating, finishing, rendering the top surface rough to receive the floor, curing, etc. complete complying with standard specification. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)
For Plain surfaces such as RCC slab, Beam, Bed Block, waist slab, landing slab, lintel etc.,
For column footing plinth beam staircase steps, piers raft beam raft slab etc.,
For square or rectangular column, boxing, sunshade etc.,
For Vertical surfaces such as sunshade boxing, vertical drops, facia for sunshade, canopy facia and other vertical walls etc.,
Mould cost using M.S.sheet and angle including cost and conveyance , welding charges etc, complete.
Triangular Module
Grouper Module
Well ring Module
Fixing and Removal of moulds for preparation of modules per single use
Supplying and fabrication of HDPE rope including cost and conveyance and all labour charges etc., complete.
Providing and laying in position, Standardised Concrete Mix M-25 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 350 kglms and maximum water cement ratio of 0.50, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).
For Foundation and Basement
For Ground Floor up to 4.50 M height
For First floor
Providing and laying in position, Standardised Concrete Mix M-30 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 400 kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).
Supplying factory fusion bonded epoxy coated with minimum 175 microns thickness H.Y.S.D. steel ( Cold, Twisted ) reinforcement for R.C.C work including cost and conveyance from point of purchase to reputed company and to site after coated straightening, cutting, bending, hooking, placing in position, lappeing and / or welding wherever required, trying with binding wire and anchoring to the adjoining members wherever necessary complete as per design etc., complete as per specification.
Supplying fabricating and placing in position of M.S./RTS rods for RCC work including binding wire,cutting,tying etc ., complete
Brick work in following Cement Mortar using best quality Fly ash bricks of size 23x11x7cm for foundation and basement including curing etc.,complete complying with standard specification.
For Foundation and Basement
For Ground Floor up to 4.50 M height
In first floor
Special ceiling plastering CM 1:3 (One cement and Three sand), 10mm thick all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
Plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
Stuccoplastering 12mm thick using HBG chips of size 10mm and below over a base of plastering with C.M 1:5 mix 12mm thick for 10 sqm including cost,conveyance etc.,
Transportation charges for 60 Nos grouper modules, 120 Nos Triangular modules and 60 Nos of well ring modules including hire & fuel charges for barge, crane, tipper lorries, winch equipments for placing fabricated artificial reefs from casting yard to the site shown by the departmental officers. The rate includes statutory fees, berthing fee, vehicle entry fee for cranes & lorry, any other fee, labour charges of all activities such as loading the reefs from casting yard to sea berth, lifting to barge and placing on the bed of sea, insurance charges of general liability for loss of life and damage of reefs during transportation and placing at sea bed etc complete complying with statndard specification. 1Job=240 modules.
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putt
Plain Cement Concrete 1:2:4 (one cement, two sand and four hard broken stone jelly) using 10-12mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.
Paving the Top of roof with Solar refelective ceramic tiles of size 305 x 305 x 7mm thick of approved quality and colour laid in Cement mortar 1:3 (One cement and three crushed stone sand) 12mm thick and pointed with tile grout (Nitotile Grout or equivalent) and cement in the ratio of 1:3 for joint, curing etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by the Executive Engineer before use on works)
Paving the floor with Granite slab of size 1200 X 600mm and above (8 X20mm thick) in all floors in CM 1:3, 20mm thick Granite slab (Ruby Red/Raw Silk/Jet Black) 20mm thick for flooring
Supplying and fixing in position best approved of ISI quality of 110mm diameters of PVC RAIN WATER DOWN FALL PIPES having a working pressure of 4 kg / sq.cm
Wiring with 2x1.5 sqm (22/0.3) PVC insulated unsheathed SC.Cu Conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box with 5A F.T. switch inflush with wall, covered with hylum sheet of 3mm thick with painting of suitable colour for open PVC light / fan point (For electronic regulator) (5 Points per Coil) -SD 22
Supplying and fixing of twin box type 4" 40W flu fitting complete with copper choke and condensor, with TW round block on wall or ceiling with tubes and PVC unsheathed Copper leads from terminals to the fitting.-SD-90
Supply and laying of 4 x 6 Sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 mt. Layer of sand and covering the cable completely with bricks and sand and refilling good. SD No. 201
Supply and fixng of TNEB meter board suitable for 3 phase 63A service connection made up of suitable angle iron frame work of size 2 feet x 1-1/2 feet using angle iron of size 1-1/2" x 1-1/2" x 1/4" rigidly fixed on wall covered with hylem sheet of size 2 feet x 1/2 feet of 6mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos. 63A fuse units (500V), 1 No. neutral link, copper earth flat of size 1" x 1/4" with inter connection of EB meter to fuse units by 7/16 PVC insulated copper wire with earth connection complete. SD No. 129
Supply and fixing of 5A 3 pin and 2 pin combined flush type wall socket with 5A flush type switch on suitable TW box connection complete. SD No. 136
Supply and fixing of 5A / 15A 3 pin combined flush type wall socket with 15A flush type switch on suitable TW box connection complete. SD No. 139
PLUG AND SOCKETS IN SHEET STEEL ENCLOSURE WITHOUT MCBs (BWD SOR - Page No.132
20A Single Pole
20A Double Pole
VERTICAL THREE PHASE DISTRIBUTION BOARD WITH MCBS 4 way / 8 way / 12 way vertical TPMCB sheet steel distribution boards flush type / surface type fitted with bus bars and neutral links with single / three phase MCB outgoings and separate 4 way provision for accommodating One No. 4 pole incoming MCB / Isolator and another separate 4 way provision for accommodating One No. 4 pole ELCB / RCD with label holder and provisions (4 ways 3 phase DB No. of ways incomer MCB / Isolator - 4 No. of ways incomer ELCB / RCD - 4 No. of outgoings ways - 12)
Supply and fixing of 65mm (2-1/2") GI pipe (Class 'B') of 6 metre length with 300mm x 300mm x 6mm MSbase plate duly welded at the bottom with concreting with construction of masonary pedestal with suitable MS box to house 5A control switch 16A fuse unit (500V) etc with suitable angle iron frame work with door and with lock and key arrangements and with supply and fixing of 4'40 W single street light fitting with copper chokes and condenser with fluorescent tubes with 1 metre of 32mm dia GI pipe (Class 'B') complete with necessary clamps on the above post with PVC unsheathed leads with painting of suitable colour SD 102
Supply and laying of 2 x 25 Sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 Meter putting 0.15 mt. layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good - SD 178
Supply and fixing of brass cable gland for 2 x 25 Sq.mm PVC LTUG armoured cable with earth connection - SD 162
Supply and clamping of 2 x 25 Sq.mm PVC LTUG armoured LTUG cable on post or on wall with M.S clamps - SD 196
Supply and fixing of 16A DP switch of 500V with metal clad with fuse and neutral (side handle) on suitable TW board with eart connection only SD 142
Sub Total Amount for above all items (excluding GST)
GST 18% for above SubTotal Amount
VMP ASSOCIATES (BID ID -1278820)
EMJAY CONSTRUCTIONS (BID ID -1278674)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_633081.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .