The Principal, Pondicherry Engineering College
The Principal, Pondicherry Engineering College
Construction of 2 Nos of Temporary Classrooms for Kasthuruba College for Women Villianur Pondicherry
2021_DHTE_8466_1
38/PEC/BD/2021-22
Open Tender
Civil Works - Buildings
Works
60 days
Kasthuruba College for Women Villianur Pondicherry
Please refer Tender documents.
3 documents required · 3 mandatory
₹525
The Principal, Pondicherry Engineering College
Exempted
31 Jul 2023
28 Aug 2021
3 Sept 2021
28 Aug 2021
3 Sept 2021
28 Aug 2021
30 days
Amount
Code No. 2.8.1 Earthwork in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed , within a lead of 50m - all kinds of soil
Code No. 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50m and lift upto 1.5m
Code No. 2.27A.1 Supplying and filling with gravel (excluding rock) in trenches , plinth, sides of foundations etc . In layers not exceeding 20 cm in depth consolidating each deposited layers by ramming and watering etc .complete including all lead and lift
Code No. 4.1.10 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plith level - 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size)
Code No. 5.1.2 Providing and laying in position specified grade of reinforced cement concrete , excluding the cost of centering , shuttering , finsishing and reinforcement - All work upto plinth level 1:1.5:3 (1cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Code No. 5.2.2 Reinforced cement concrete work in walls (any thickness) , including attached pilasters, buttresses , plinth and sting courses , fillets , columns , pillars , piers , abutments , posts and struts etc. upto floor five level excluding cost of centering , shuttering , finishing and reinforcement - 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size)
Code No. 5.9.1 Centering and shuttering including strutting , propping etc and removal of form for - foundations, footings, bases of columns etc for mass concrete
Code No. 5.9.5 Centering and shuttering including strutting , propping etc and removal of form for - Lintels , beams , plinth beams , girders , bressumers and catilevers
Code No. 5.9.6 Centering and shuttering including strutting , propping etc and removal of form for - Columns , Pillars, Piers , Abutments , Posts and Struts
Code No. 5.22.6 Steel reinforcement for R.C.C.work including straightening , cutting , bending , placing in position and binding all complete upto plinth level - Thermo -Mechanically treated bars (TISCON / VIZAG / IISCO / SAIL / JSW) Fe - 415 or more.
Code No. 6.1.2 Brick work with common burnt clay F.P.S. (non modular ) bricks of class designation 7.5 in foundation and plinth in - cement mortar 1:6 (1 cement : 6 coarse sand)
Code No. 6.13.2 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level upto floor V level - cement mortar 1:4 (1 cement : 4 coarse sand)
Code No. 9.48.2 Providing and fixing M.S.grills of required pattern in frames of windows etc with M.S. flats , square or round bars etc. including priming coat with approved steel primer all complete - Fixed to openings / wooden frames with rawl plugs screws etc
Code No. 11.3.1 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc.complete - 40mm thick with 20mm nominal size stone aggregate
Code No. 12.8 Providing high impact polypropylene reinforced cement 6mm thick corrugated sheets (as per IS:14871) roofing upto any pitch and fixing with polymer coated J or L hooks , bolts and nuts 8mm dia G.I.plainand bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required.
Code No. 12.12.1 Providing and fixing ridges and hips in fibre cement high impact polypropylene reinforced roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc.complete - corrugated serrated adjustable ridges
Code No. 10.16.2 Steel work in built up tubular (round,square or rectanglar hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete - hot finished seamless type tubes.
Code No.13.16.1 - 6mm cement plaster of mix 1:3 (1 cement : 3 fine sand)
Code No.13.1.1 - 12mm cement plaster of mix -1:4 ( 1 cement : 4 fine sand)
Code No.13.2.2 - 15mm cement plaster on the rough side of single or half brick wall of mix - 1:6 (1cement : 6 fine sand)
Code No. 13.28.4 - 12mm thick plain cement mortar bands in cement mortar 1:4 (1cement : 4 fine sand) - re moulded band
Code No. 12.45.1 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S.sheets and galvanized with zinc coating of 120 gms / sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25mm wide x1.6mm thick with flanges of 27mm and 37mm , at 1200 mm cenetre to centre, one flange fixed to the ceiling with dash fastener 12.5mm dia x50mm long with 6mm dia bolts ,other flange of cleat fixed to the angle hangers of 25x10x0.50mm of required length with nuts and bolts of required size and other end of angle hanger fixed with intermediate G.I channels 45x15x0.9mm running at the spacing of 1200 mm centre to centre , to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having clips of 10.5mm, at 450mm centre to centre ,shall be fixed in a direction perpenticular to G.I.intermediate channel with connecting clips made out of 2.64mm dia x 230mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimetre of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre , with 25mm long dry wall screws @ 230 mm interval , including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x25mm at 230mm C/C , including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150mm on both sides of joint and two coats of primer suitable for board , all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimetre channels suitably fixed , all complte as per drawings, specifications . But excluding the cost of painting with - 12.5mm thick tapered edge gypsum plain board conforming to IS: 2095 - part-I
Code No. 13.37.1 White washing with lime to give an even shade - new work (three or more coats)
Code No. 13.44.1 Finishing walls with water proofing cement paint of required shade - New work (Two or more coats applied @ 3.84 kg / 10 sqm)
Code No. 13.50.4 Applying priming coat - with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat)
Code No. 13.61.1 Painting with synthetic enamel paint of approved brand and manufacutre to give an even shade - Two or more coats on new work
K Anandaraman
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_8661.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .