Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹36.4 L+₹8.7 L (31.2%)Rejected-Finance NO 18 BHARATHI STREET WEST GANDHI NAGAR AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹36.4 L+₹8.7 L (31.5%)Rejected-Finance 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹38.8 L+₹11.1 L (40.1%)Rejected-Finance NO 15 PULAVAR GOVINDAN STREET GANDHI NAGAR AVADI CHENNAI 600 054 | AVADI | CHENNAI | TAMIL NADU | 600054 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹39.3 L+₹11.6 L (41.7%)Rejected-Finance 19 C CUDDALORE MAIN ROAD PEDDANAICKENPALAYAM PO TK SALEM DIST PIN 636 109 | SALEM | SALEM | TAMIL NADU | 636109 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹36.0 L
EMD Value
₹71,900
Closing Date
10 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER AIRFORCE THANJAVUR
GARRISON ENGINEER AIRFORCE THANJAVUR
PROVISION OF INFRASTRUCTURE FOR INSTALLATION OF RT GRID BATCH III AT 321 TRU DETT KODIAKKARAI UNDER AFS THANJAVUR
2023_MES_574467_3
8933/E8
Open Tender
Civil Works
Item Rate
240 days
THANJAVUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GARRISON ENGINEER AIRFORCE THANJAVUR
₹71,900
17 Mar 2023
30 Jan 2023
11 Feb 2023
30 Jan 2023
10 Feb 2023
5 Feb 2023
Amount
PCC 1:4:8 type D2 (40mm graded aggregate) Cement concrete foundations, filling and mass concrete complete all as specified and directed.
Brickwork with flyash bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed.
M&L Moorum / red bajri obtained from outside MD land, filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
RCC M30 in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
M&LMild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
All as per Srl Item No 6 above but for 8mm dia.
All as per Srl Item No 6 above but for 8mm dia as in stirrups.
M&L Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M & L for 75mm thick PCC 1:4:8 using 40mm graded stone aggregate as in subbase to floor complete all as specified and directed.
M&L Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 20mm thick screed bed in CM(1:6) complete all as specified and directed.
M&L for rendering 10mm thick on brick or concrete surfaces in CM (1:6) finished even & smooth without using extra cement complete all as specified and directed.
M&L for two coats of cement based paint over coat of primer on concrete surface in cluding preparation of surfaces complete all as specified and directed.
Supply Fabricate and installation of Double skin wall using One no’s 10 mm thick (out side) and One no 10 mm Thick (Inside) cement bonded particle board confirming IS 14276-1995 and the panels are fix over the fabricated frame of grid 610 mm x 1220 mm using 30 x 30 x 1 mm thick MS hollow box section and the panel joints are fix by 25 x 6 mm Wood reaper in inside and all external joints are fill with White colored Paintable slicon with groove and the panel are painting with one coat of primer and two coat of OBD as interior and one coat of any branded exterior paint as exterior paint and the gap is fill with 30 mm Thick EPS Insulation material and we leave opening for doors and windows where ever required , but during measurement , no deduction for doors and window opening etc complete all as specified and as directed.
Supply fabricate and installation of door shutters using 30 mm thick IS Quality of any brand of Hot Boiling waterproof flush door and fix all around wooden beading with required fittings of 3 no’s 5” hinges with one no 10” Aldrop and two no’s 10” Tower bolt and two nos Handle all are aluminum powder coated and the panel is painted with one coat of primer and two coat of approved enamel paint etc complete all as specified and as directed.
Supply fabricate and installation Roof structure using 100 x 50 x 2.6 mm Column at every 3.660 C/c Over that fix Ladder type A’ Model Trusses using 80 x 40 x 1.6 mm MS Box section Top and 60 x 40 x 1.6 mm section as Bottom and use 60 x 40 x 1.6 mm intermediate at every 2’0” C/C and diagonally and provide 80 x 40 x 1.6 mm thick section as purloin at every 1.220 mm C/c and provide Edge of Eves side Over that laying of 0.45 mm Thick Pre Painted Galvalume roof sheet fix by means of suitable self tapping bolts as per the manufactures recommendation and all steel section are painted with one coat of red oxide and two coat of approved enamel paint etc complete Measuremet is to be taken by Roof laid area complete all as specified and as directed.
Supply fabricate & Installation of 2 Shutters Aluminum sliding windows using standard aluminum section and the shutter is fill with 5 mm thick tinted glass and I provide MS Section grill made out of 32 x 32 x 3 mm MS Angle all around and 12 mm sq bars horizontally at every 100 mm C/c and provide 32 x 3 mm MS Flat in center and the whole systems fox to inside the wall by means of self tapping screws and provide 0.45mm thick PPGL Bended profile as Sunshade and the grills is painted with one coat of red oxide and two coats approved enamel paint etc complete all as specified and as directed. 6 windows of size 4 x 4
Supply fabricate & installation of false ceiling using 4 mm thick ‘V’ panel & Prepainted Prenotched GI section as grid of 600 x 600 mm suspended from the roof truss by means of 6 mm MS Rod and over the board laying of 15 mm Thick EPS Insulation sheet and the rate id inclusive of One coat of primer on both sides and two coats of approved colour interior Emulsion painting over the board etc complete all as specified and as directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed.
S&F for MS work as in post struts complete all as specified and directed.
S&F MS work in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F MS work as in wind ties complete all as specified and directed.
Preparing new steel surfaces of any description, over 10cm width or girth and applying two coats of anti corrossive epoxy paint over a coat of epoxy red oxide primer complete all as specified and directed.
Excavating in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. nexc 10 sq m on plan and n exc 1.5 m in depth and getting out in loose soil complete all as specified and directed.
Excavating in trenches, n.exc 1.5 m wide and exc 1.5 m and n.exc 3m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. nexc 10 sq m on plan and n exc 1.5 m in depth and getting out in loose soil complete all as specified and directed.
RCC M 30 as in walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses
Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter fair finished surface complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in loose soil.
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cemet and pigment complete all as specified and directed.
M&L for sand filling under paver block complete all as specified and directed.
S&F MS Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165
Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out in soft/loose soil.
M&L PCC 1:2:4, using 20mm graded aggregate as in kerb stone
M&L for Chequered cement concrete tiles 300 x300 x 25mm thick, set with grey cement and pigment, jointed and pointed in neat cement slurry in floors including 15mm thk screed bbed in CM 1:6 complete all as specified and directed.
M&L for Chequered cement concrete tiles 300 x300 x 25mm thick, set with grey cement and pigment, jointed and pointed in neat cement slurry in dado/skirting/riser including 10mm thk backing coat in CM 1:4 complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Material and labour point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed FRLS 1100 Volt grade multistranded copper conductor cable drawn through and incl 20 mm casing capping and accessories complete fixed surface to wall/roof/ceiling etc and incl 1.5 sqmm single core PVC insulated, unsheathed FRLS 1100v grade multi stranded copper conductor cable as earth continuity conductor cable & connecting to common earth dolly incl pressed steel terminal boxes made out of 1.6mm MS sheet surface fixing on walls/roof/ceiling etc with laminated 3.0 mm thick masonite sheet with cadmium plated iron screws and cup washers for housing switches/sockets/fan regulator etc for the following :-
One light point each controlled by one switch.
One ceiling fan/exhaust fan point each controlled by one switch.
One 3 pin 5 A socket outlet on independent board .
All as per Srl Item No 38 above but for one 3 Pin 15 A S/S combination using cable 2.5 Sqmm and 1.5 Sqmm earth continuity conductor.
Supply & fixing of Switch Piano flush type single pole one way 5/6 amp.
Supply & fixing of Switch Socket combination 3 pin, 5A flush type.
All as per Srl Item No 41 but 2 in 1 3Pin 5A & 15A.
S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole and neutral with 200 amps rated bus bar, IP-43 protection suitable for fixing MCB complete all as specified and as directed
S&F MCB, Single pole & neutral, 6 to 32 amps, 240 volts, ‘C’ curve, 10KA complete all as specified and as directed
S&F MCB, Single pole & neutral, 40 to 63 amps, 240 volts, ‘C’ curve, 10KA complete all as specified and as directed
S&F Sub main wiring with 2 runs of 4 sqmm PVC insulated unsheathed copper cable multistranded 1100V, FRLS grade with PVC cashing caping with accessories fixed on wall/ceiling/truss etc and one run of PVC insulated 4 sqmm copper conductor cable as earth continuity complete all as specified
S&F ceiling rose, surface bakelite, large type, 220/240 volts, three terminals, white/ivory finish complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor(BLDC) complete all as specified and as directed
S&F Exhaust fan, steel body AC single phase. 230 V of size 300mm sweep with blades, and frame and louvers complete all as specified and as directed
Supply and fixing in replacement of PRIDE PLUS INVERTER BATTEN wall mounted inverter LED light 20 Watt LED, with square profile and polycarbonate channel, Lithium ion Battery with charging time 8 hours to 10 hours and backup time upto 4 hours complete all as specified and directed. Make as per Havells Cat Part.No: LHEXACP7FN1W020 or equivalent in wipro and Bajaj.
Supply and fix LED street light 20 W IP 65 SUPERB STREET LIGHT Street Lights with best in class design & Robust heat sink along with class leading IP, IK & Surge protections for long lasting performance. complete all as specified and directed. Make as per Havells Cat Part.No: LHEXAYP7PN6K020 or equivalent in wipro and Bajaj.
S&F in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with single pole MCB 20 amps capacity complete all as specified and directed.
Supply, laying XLPE insulated, screened PVC beaded, galvanized steel strip or wire armoured electric power cables (heavy duty) with stranded aluminium conductor, 1100 Volts grade of size 16 sq mm 2 core complete all as specified and directed.
Material and labour for earthing complete wit galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to but using galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed.
Supply and fixing 4 pole MCCB 63 amps 50 HZ, 415 volts with ruptering capacity 25 KA. To be fixed at the existing panel with suitable alteration complete all as specified and directed.
Returning and filling in two parts (i) using riddled soil obtain from excavated soil upto depth of 30 cm (8 cm below cable and remaining above cable) for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil all as specified.
Supply and laying Bricks, sub class 'B' old size bricks, laid flat dry with width of the bricks laid to the axis of the cable all complete as specified.
Supply, laying XLPE insulated, screened PVC beaded, galvanized steel strip or wire armoured electric power cables (heavy duty) with stranded aluminium conductor, 1100 Volts grade of sizes 50 sqmm 3.5 core complete all as specified and directed.
All as per Item No 58 here-in-before but 25 sqmm 3.5 core.
All as per Item No 58 here-in-before but 10 sqmm 4 core.
Supply install test and commission LT Panel board, TPN 415 Volts, 50 Hz, 200 Amps capacity, out door cubical type floor mounted factory made dust and vermin proof fabricated out of CRCA sheet not less than 3.15 mm thick fixed on angle iron frame made out of 60x60x6 mm with cable chamber for individual feeders for incomming and outgoing connections, one set of LED indicator lamp RYB with switch and fuse, multifunction intelligent panel meter etc and with the followings :- INCOMING:- (a) MCCB 4 Pole, 415V, 36KA Adjustable Thermal Magnetic of capacity 63A - 1 No. OUTGOINGS:- (a) MCCB 4 Pole, 415V, 36KA Adjustable TM of capacity 32A - 1 No (15KVA Load). (b) MCCB 4 Pole, 415V, 25KA Adjustable TM of capacity 25A - 1 No (10 KVA stablizer). (c) MCB 4 Pole, 415V,of capacity 10A - 1 No (Bldg).
Supply and fixing 4 pole MCCB 63 amps 50 HZ 415 volts ruptering capacity 25KA with adjustable thermal and magnetic setting complete with suitable mounting arrengemen including sheet matel enclosure .(for Stablizer out) complete all as specified and directed.
Supply and fixing 4 pole MCCB 40 amps 50 HZ 415 volts ruptering capacity 25 KA with adjustable thermal and magnetic setting complete with suitable mounting arrengemen including sheet matel enclosure.(for 15 KVA In) complete all as specified and directed.
Earthing complete with copper plate 600 x 600 x 3.15 mm thick, burried directly in ground (earth pit not less than 2.25 metrres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to 20x3 mm copper strip by means of bolts, nuts and washers of copper earthing lead protected by GI pipe light grade 40mm dia all as shown in electrical plate No 5 of SSR Part I connected to earth testing point, testing complete. (2x 10 (pnl)= 20 + 10 Nos for bldgs= 30 nos) complete all as specified and directed.
Supply and fix voltage stablizer for automatic operation, three phase, naturally oil cooled indoor type designed for input variation between 300V to 480V with output voltage stablized at 415V with accuracy +2.5% and speed of correction 8V per second and of capacity 10KVA. complete all as specified and directed.
Supply and installation, test and commissioning of acoustic proof AMF panel type diesel engine driven generating set fully wired 415 volts + 5% AC three phase 4 wire 50 Hz having capacity 30 KVA continous rating. Power factor .8 (lagging) as per IS 4722 and connections as per IE rule. DG set mounted on common base plate with anti vibration pad mounting including foundations as recommended by manufacturers. The Gen Set shall confirm to CPCB norms for noise and emmission limits and necessary certificate from NAL to this effect shall be submitted and complete with AMF control panel board with 5 module microprocessor based engine safety unit all as specified and directed consisting of the following :-
DIESEL ENGINE:- The engine shall be liquid cooled turbo charged after cooled type, all lube oil filter , fuel pump, injectors shall be housed outside recker cover to enable easy maintenance . Engine rating shall be not less than 42 HP prime mover @ 1500 RPM, configuration 90 degree V type , 3 cycle ,fuel pump with electronic governer, oil filter, Radiator with fan ,exhaust and silencer pipe and insulated with glass wool and aluminium cladding safety devises and other standard fitting such as speedo meter/ hours meter etc all as engine as per IS:10001/10002 complete.
ALTERNATOR:- The alternator shall be designed for an output of 30 KVA continous rating at .8 PF screen protected drip proof in IP- 21 enclosure and closed coupled with the engine with class H or better insulation and confirming to IS: 13364, rated RPM 1500 incu self excited self regulated brush less and self ventilating type control panel with accessories. Electric supply terminal box with gland , earth terminal etc complete all as specified.
ELECTRICAL SYSTEM:- The electrical system of the startor motor and charging alternator shall have the following components. (i) Batteries 1 nos- 12v DC x150 AH . (ii) starter motor , Battery charging alternator. (d) FUEL TANK: 65 litres capacity with inlet.outlet,air vent and drain arrangement. (e) AMF PANEL :- Control Panel with controller of Make as per Kirlosker Green Gen Set engine model No 3R1040T G1/ AL2CTIDG1 Ashok Leyland or equivalent of Greaves cotton/ cummins/ Jakson.
Material and labour for earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth strip 32x6 by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed.
Supply and fix fire alarm control panel complying with BS EN 54 of 2 zone fire control panel and modules including suitable power supply complete all as specified and directed.
Supply and fix detectors complying with and type certified to EN - 45 addressible type multisensor detector with heat and smoke combination photoelectric / optical with base with self built intelligence as per IS 11360 complete all as specified and directed.
Supply and fix Addressable manual call point resettable type with alarm LED complete all as specified and directed.
Supply and fix Fire Alarm Sounders / Sirens Electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured at 1.5 m with sound output variation of + 5 DB complete all as specified and directed.
Supplying and fixing of submain wiring along with 2x1.5 sq. mm+ 1x1.5 sq. mm earth wire of FRLS is PVC insulated copper conductor, single core cable in surface laying through steel conduit with proper saddles.(For detectors) complete all as specified and directed.
BKR Enterprises
R K BUILDERS
D Subramani and Sons
S.T.S.CONSTRUCTIONS AGENCIES
SMS CONSTRUCTION
Manoprabha Electricals
SUPER COOL
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .