Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAccepted-AOC NO 6 V O C STREET II MAIN ROAD DHATCHANAMURTHY NAGAR SOKKANTHANPET PUDUCHERRY 605 009 | PONDICHERRY | PUDUCHERRY | 605009 | ₹14.0 L | L1 | Accepted-AOC 1st lowest |
| 2 | L2₹14.7 L+₹73,686 (5.27%)Rejected-Finance NO 23 JEEVANANDAM STREET PUDUCHERRY 605 001 | PUDUCHERRY | PUDUCHERRY | PUDUCHERRY | 605001 | ₹14.7 L+₹73,686 (5.27%) | L2 | Rejected-Finance II Lowest |
| 3 | L3₹17.7 L+₹3.8 L (27.0%)Rejected-Finance 42 A METTU STREET MUTHIRAPALAYAM PUDUCHERRY 605009 | PUDUCHERRY | PUDUCHERRY | PUDUCHERRY | 605009 | ₹17.7 L+₹3.8 L (27.0%) | L3 | Rejected-Finance III Lowest |
Tender Value
₹14.5 L
EMD Value
₹28,951
Closing Date
26 Jul 2022, 4:30 pmClosed
Executive Engineer
Office of the Executive Engineer, BRS, PWD, Puducherry
Reconstruction of damaged compound wall at North West corner of switch yard and replacement of existing failed mono block jet pump and worn out water pipes inside the premises of 230 110KV Villianur Auto Sub Station, Electricity Department, Puduche
2022_PWDC1_10713_1
No.13/PW/EE/BRS/2022-23
Open Tender
Civil Works
Item Rate
90 days
Puducherry
Please refer Tender documents.
3 documents required · 3 mandatory
₹525
₹28,951
30 Aug 2022
19 Jul 2022
27 Jul 2022
19 Jul 2022
26 Jul 2022
19 Jul 2022
Amount
Earthwork in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed , within a lead of 50m - all kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50m and lift upto 1.5m
Supply of Quarry rubbish including stacking to department gauge for premeasurement and spreading required thickness
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plith level - 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns,piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping,bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc. upto floor five level, excluding the cost of centering ,shuttering and finishing - 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete , excluding the cost of centering , shuttering , finsishing and reinforcement - All work upto plinth level 1:1.5:3 (1cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness) , including attached pilasters, buttresses , plinth and sting courses , fillets , columns , pillars , piers , abutments , posts and struts etc. upto floor five level excluding cost of centering , shuttering , finishing and reinforcement - 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size)
Centering and shuttering including strutting , propping etc and removal of form for - foundations, footings, bases of columns etc for mass concrete
Centering and shuttering including strutting , propping etc and removal of form for - Lintels , beams , plinth beams , girders , bressumers and catilevers
Centering and shuttering including strutting , propping etc and removal of form for - Columns , Pillars , Piers , Abutments , Posts and Struts
Steel reinforcement for R.C.C.work including straightening , cutting , bending , placing in position and binding all complete upto plinth level - Thermo -Mechanically treated bars (ISI BRAND OF APPROVED MAKE) Fe - 415 or more
Brick work with common burnt clay F.P.S. (non modular ) bricks of class designation 3.5 in foundation and plinth in - cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S (non modular ) bricks of class designation 3.5 in superstructure above plinth level upto floor five level in all shapes and sizes in - cement mortar 1:6 ( 1 cement : 6 coarse sand)
12 mm cement plaster of mix 1:5 (1 cement : 5 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix 1:5 (1 cement : 5 fine sand)
Applying one coat of water thinnable cement primer of approved brand and manufacturer on wall surface - water thinnable cement primer
Finishing walls with water proofing cement paint of required shade - New work (Two or more coats applied @ 3.84 kg / 10 sqm)
Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead - in cement mortar
Supplying of electrically operated wet type submersible motor and pumpset (Texmo/KSB/Taro/Kirloskar make), AC 3 phase, 415 volts, 50 Hz, 2900-3000 RPM. The pump shall have brass impeller, high grade steel shaft with sufficient stages having outlet size of 2"/2.5"/3" dia. to suit the borewell (150 / 200mm dia.), complete.The rate includes, all taxes, freight, etc., FOR at site in UT of Puducherry. The pumpset shall be guaranteed for a period of one year from the date of commissioning.(5 HP Submersible motor and pumpset).
Supplying and fixing of fully automatic air break star-delta starter range for 5A to 13A F.A.S.D. (Bharat Culter Hammer/ L&T/ Siemens make) with suitable M.S. angle frame etc., complete.- 5HP to 12.5 HP pumpsets
Supplying and fixing of 1x3x4 sqmm (single run) PVC insulated copper submersible flat flexible cable of Finolex make complete.-upto 10HP pumpset.
Supplying,fixing and lowering into the borewell high tensile threaded PVC column pipes which are to be connected to the submersible pump,including labour charges,jointing materials etc.,complete.-50 mm dia
Providing and fixing ASTM pipes including all ASTM plain & brass threaded fittings this included jointing of pipes & fittings with one step ASTM solvent cement , trenching refilling & testing of joints complete (External work) - 40 mm nominal outer dia pipes
Providing and fixing brass gate valve with C.I. wheel of approved quality (screwed end) - 50mm nominal bore
Providing and fixing in position G.I. elbow (UNIQUE/R Brand/HB Brand/UI Brand) conforming to IS 1239 part II and ISI marked,including labour charges for jointing, jointing materials etc,complete - 50 mm dia.
Providing and fixing M.S. top cover suitable for UPVC pipes including the cost of materials and labour etc.
Supply and fixing of 80/100mm dia. M.S. erection clamps of size 80mmx12mm with bolts, nuts, washer etc., complete
Providing and fixing in position G.I. coupling (UNIQUE/R Brand/HB Brand/UI Brand) conforming to IS 1239 part II and ISI marked,including labour charges for jointing,jointing materials etc,complete - 50 mm dia.
Erection, testing and commissioning of motor and pumpset complete.The rate includes obtaining electricity service connection from Electricity Department also.
Supplying and laying of 16mm dia nylon rope for holding of motors
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m - all kinds of soil - pipes,cables etc , exceeding 80mm dia but not exceeding 300 mm dia
Providing, laying and jointing UPVC pipes(Finolex / jain / Supreme / Truebore / Nandi) (1 Mpa)conforming to IS specification 4985 and ISI marked including transportation to the site , lowering to the trenches, laying to proper grade and alignment, testing of joints with required testing equipment,including cost of solvent cement,excludingUPVC specials such as bends,tees, threaded pieces, couplers, reducer, endcaps etc.,complete all as per IS and CPWD specification. - 90mm dia.
Providing and fixing ASTM pipes including all ASTM plain & brass threaded fittings this included jointing of pipes & fittings with one step ASTM solvent cement , trenching refilling & testing of joints complete (External work) - 25 mm nominal outer dia pipes
Providing and fixing brass bib cock of approved quality - 20 mm nominal bore
Providing and fixing in position G.I. Hex nipple (UNIQUE/R Brand/HB Brand/UI Brand) conforming to IS 1239 part II and ISI marked,including labour charges for jointing,jointing materials etc,complete - 40 mm dia.
sabastinmartial
P Ramamoorthy
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .