RequiredExperience with Government
RequiredAnnual Turnover
RequiredOEM Authorization Certificate Bid to RA enabled No Steel Porta Cabin ( 6 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) GENERIC Configuration of Cabin With one Room and Verandah. With one Room and Verandah.
RequiredWith one Room only.
RequiredWith one room
Requiredone kitchen and verandah
RequiredWith three rooms
Requiredone kitchen and verandah Transportations Freight charges Offer Prices are on Free Delivery at Consignee * 1/13 site basis. Approval of Advance sample After award of contract - Seller shall have to get proto type Advance sample approved from Buyer before manufacturing starting Bulk supplies - Buyer shall approve provide list of modifications required within 10 days of offer of advance sample - If there is delay in approval of advance sample from Buyer side - the delivery period shall be regularized for the period of delay in sample approval. After award of contract - Seller shall have to get proto type Advance sample approved from Buyer before manufacturing starting Bulk supplies - Buyer shall approve provide list of modifications required within 10 days of offer of advance sample - If there is delay in approval of advance sample from Buyer side - the delivery period shall be regularized for the period of delay in sample approval.
RequiredNo Advance Sample Foundation for Cabin Building of Foundation at site shall be the responsibility of the Consignee and the Seller shall Install Erect and Commission the structure on the foundation constructed upto plinth level by the Consignee. * Special Condition Scope of supply includes Supply and Erection of Cabin at consignee site hence Offer Price to include all these cost components. Further Offer Prices are on Free Delivery at Consignee site basis hence Transportation/Freight charges are to be included in Offer price. Building of Foundation at site shall be the responsibility of the Consignee and the Seller shall Erect the structure on the foundation constructed upto plinth level by the Consignee. In case advance sample is required - after award of contract - Seller shall * 2/13 have to get Advance sample approved from Buyer before manufacturing starting Bulk supplies. Buyer shall approve provide list of modifications required within 10 days of offer of advance sample. If there is delay in approval of advance sample from Buyer side - the delivery period shall be regularized for the period of delay in sample approval. Time period for completion of Erection work at site by seller Within 30 days of the date of receipt of consignee's confirmation regarding completion of ground and foundation work Within 20 days of the date of receipt of consignee's confirmation regarding completion of ground and foundation work
RequiredWithin 30 days of the date of receipt of consignee's confirmation regarding completion of ground and foundation work Suitability structural stability completness of structures
Requiredthe structure is intended for use in In wind condition of 55m/s - in Seismic zone V and ambient temperature range (-) 40 degree C to (+) 50 degree C - 1 M snow load standing on the roof - Roof slope 1 : 2 Cabin should be structurally stable and suitable to meet severity of these climatic condition. In wind condition of 55m/s - in Seismic zone V and ambient temperature range (-) 40 degree C to (+) 50 degree C - 1 M snow load standing on the roof - Roof slope 1 : 2 Cabin should be structurally stable and suitable to meet severity of these climatic condition.
RequiredIn wind condition of 55m/s - in Seismic zone V and ambient temprature range 0 degree C to (+) 50 degree C - Roof slope 1 : 2 Cabin should be structurally stable and suitable to meet severity of these climatic condition. Shape of Cabin Rectangular * Type of slope(roof) Two way slope. One way slope.
RequiredTwo 3/13 way slope.
RequiredAll side slope. Insulation of Wall/Roof door panels Insulation core of panel to be formed in one piece and provides desired structural and physical properties. * Ventilation Without ventilator. * Storage provision 1 no. Wooden Cabinet 1 no. Wooden Cabinet
Required1 no. Steel Almirah
RequiredN.A Provision for Power Connection The seller to be liable to get the Electric connection through 3 core insulated underground cable covered with PVC pipe from the power supply point provided by the Buyer. The seller to be liable to get the Electric connection through 3 core insulated underground cable covered with MS pipe from the power supply point provided by the Buyer.
RequiredThe seller to be liable to get the Electric connection through 3 core insulated underground cable covered with PVC pipe from the power supply point provided by the Buyer.
RequiredProvision for Power Connection not required. Wiring Concealed wiring Concealed wiring
RequiredSurface wiring Provision for Cable
RequiredSwitches and Junction box connection Seller to make appropriate provisions for cable laying - installing meter junction box with switches - other related electrical accessories as may be require for the power supply to the Cabin. Seller to make appropriate provisions for cable laying - installing meter junction box with switches - other related electrical accessories as may be require for the power supply to the Cabin.
RequiredProvision for Cable
Requiredswitches and Junction box Connection not required. Other requirements Not required. All necessary required permissions from civic agencies for installation and commissioning to be arranged by seller - necessary assistance documents required to be provided by Buyer.
RequiredNot required. 4/13 Completeness of the work Any fittings or items which may not be specially mentioned in the specifications but which are necessary for commissioning of Cabin are to be provided by the Seller without any extra charge. * Electricity charges N.A * PANEL MATERIAL Side wall panel material 1.25 mm thick corrugated HR sheet 1.25 mm thick corrugated HR sheet Door panel material Flush door 32 mm thick water proof. Flush door 32 mm thick water proof.
RequiredWaterproof BWP flush door 34 mm thick Window panel material Powder coated aluminium sliding windows with 4 mm tinted Glass Powder coated aluminium sliding windows with 4 mm tinted Glass
RequiredPolycarbonate sheet of 6 mm thick.
RequiredBoard Aluminium frame (60 mm x 30 mm) sliding shutter with 5 mm plain glass.
RequiredWith aluminium grill protection from inside alongwith mosquito mesh.
RequiredAluminium sliding window having dark glass with grill and rain gutter Door and Window canopy material 1.25 mm thick corrugated HR sheet Fibreglass Reinforced plastics (F.R.P).
Required18 gauge MS corrugated sheet.
Required1.25 mm thick corrugated HR sheet
RequiredN.A Floor panels material 15 mm heavy duty cement fiber board inside and outside texture paint. 24 mm Block board thickness with FRP coating checkers style.
Required19 mm thick marine grade plywood confmg. to IS 710/latest to be laid on top and secured by self - tapping screws to the base members - Covered with 2 mm thick PVC sheets.
Required16 mm thick marine grade plywood with Vinyl carpet.
Required15 mm heavy duty cement fiber 5/13 board inside and outside texture paint.
Required18 mm thick BWP plyboard mounted on top and above that PVC to be attached on above surface.
RequiredBWP marine grade ply board 12 mm thick with PVC vinyl sheet on top.
Required18 mm plywood with 1.5 mm vinyl sheet Roof panel material 1.25 m thick corrugated HR sheet Fibreglass Reinforced plastics (F.R.P)
Required18 gauge MS corrugated sheet
Required2 mm thick plan MS sheet Confmg. to IS 1079
Required2 mm thick plan MS sheet Confmg. to IS 513
RequiredInsulated Roof to be made of continue line sandwich panels with 0.35 mm thick pre- coated steel sheet (PPGI sheet) having 120GSM with minimum 4 microns epoxy primer on both sides of sheet and polyester top coat minimum 15 microns ON BOTH SIDES OF PUF.
RequiredMade out of plain GI sheet 0.63 mm thick chemically treated.
Required75 mm thick panels of thermal insulated stuffed - High grade galvanized steel chemically coated with six layers from inside and outside.
Required0.45 mm corrugated galvanized colour coated sheet.
Required1.25 m thick corrugated HR sheet End panel material 1.25 mm thick corrugated HR sheet * Insulation material for sides and End walls 30 mm high density thermocol. With 50 mm thick glass wool
RequiredWith polyurethane foam (PUF) having density 40 Kg/CuM ± 2 Kg/CuM.
Required30 mm high density thermocol.
RequiredResin bonded with EPS thermo-Cole 75 mm 6/13 thick - sand casted and texture finish/color (outside only)
RequiredN.A Insulation material for Roof 30 mm high density thermocol. With 75 mm thick glass wool
RequiredWith polyurethane foam (PUF) having density 40 Kg/CuM ± 2 Kg/CuM
Required30 mm high density thermocol.
RequiredResin bonded with EPS thermo-Cole 75 mm thick - sand casted and texture finish/color (outside only)
RequiredN.A Inside panel material for sides
Requiredend walls & roof Consists of 8 mm thick pre-laminated board. Consists of 8 mm thick pre-laminated board.
RequiredWall internal cladding by 50 mm thick glasswood with 6 mm prelaminated plywood (having colour as per buyer's choice) - fixed with aluminium stiffener and rivets
RequiredN.A FRAME MATERIAL Roof frame Made of MS having stiffner Top 40 mm x 20 mm x 3.2 mm thick Made of MS having stiffner Top 40 mm x 20 mm x 3.2 mm thick
RequiredMade of MS having stiffner Top 40 mm x 20 mm x 3.5 mm thick
RequiredMade of MS having stiffner Top 40 mm x 20 mm x 4 mm thick
RequiredMade of MS having stiffner Top 50 mm x 25 mm x 2.5 mm thick and 32 mm x 32 mm x 2 mm MS sq. tubes
RequiredSupported MS structure with Column - Truss - Portal truss - Purlin - Tie member
RequiredMS frame of 32 mm x 32 mm size 16 gauge square hollow tube section. Side Panel frame Made of MS having stiffner Top 40 mm x 20 mm x 3.2 mm thick Made of MS having stiffner Top 40 mm x 20 mm x 3.2 mm thick
RequiredMade of MS having stiffner Top 40 mm x 20 mm x 3.5 mm thick
RequiredMade of MS having stiffner Top 40 mm x 20 mm x 4 mm thick
Required7/13 Supported MS structure with Column - Truss - Portal truss - Purlin - Tie member
RequiredMS frame of 32 mm x 32 mm size 16 gauge square hollow tube section. Floor panel frame MS having 50 mm x 50 mm x 1.2 mm MS having 50 mm x 50 mm x 1.2 mm
RequiredMS having 50 mm x 50 mm x 1.5mm
RequiredMS having 50 mm x 50 mm x 2 mm
RequiredMS having 50 mm x 50 mm x 3 mm
RequiredTo be made out with 1.2 mm MS folded section in required size and shape.
RequiredMS frame of 32 mm x 32 mm size 16 gauge square hollow tube section.
RequiredMS Tubular pipes of 50 mm x 50 mm heavy gauge. Window panel frame Aluminium glazed sliding window anodized sections frame * Understructure/Base Made up of MS pipe 50 mm x 50 mm x 1.2 mm thick for vertical and beside - Centre block and outer ride with 25 mm x 25 mm x 2 mm thick MS pipe * Door panel frame Other than aluminium frame. * Dimensions and Thickness Inside Length ± 15 mm 6100 mm 1220 mm
Required1525 mm
Required1830 mm
Required2135 mm
Required2210 mm
Required2440 mm
Required3050 mm
Required3960 mm
Required6100 mm Inside Width ± 15 mm 3050 mm 1065 mm
Required1220 mm
Required1830 mm
Required2135 mm
Required2210 mm
Required2440 mm
Required3050 mm
Required3660 mm
Required1525 mm
Required7620 mm Total Height (mm) ± 15mm 2590 mm 2135 mm
Required2285 mm
Required2440 mm
Required2590 mm
Required2750 mm
Required2895 mm Size of Window ± 10 mm 900 mm x 900 mm * 8/13 Door Width ± 5 mm 915 mm * Door Height ± 10 mm 2135 mm * Size of Door handle SS 302 Latch 200mm * Size of Tower bolt SS 302 125 mm * Size of Aldrop 200 mm x 16 mm of SS 302 * Size of door hinges 100 mm of SS 302 * Size of Door/Window Chajja (projection if any) ± 10 mm 455 mm wide 45 degree slope * Roof projection (if any) ± 10 mm N.A 305 mm to be given on all sides at full height of cabins.
Required300 mm from the Eaves wall and 150 mm from the Gable walls.
Required380 mm to be given on all sides at full height of cabins.
RequiredN.A Total thickness of Wall panel ± 2 mm 40 mm 75 mm
Required47 mm
Required40 mm
Required30 mm
Required20 mm
Required15 mm Total thickness of Door panel ± 2 mm 35 mm 40 mm
Required35 mm
Required30 mm
Required20 mm
Required15 mm Roof ridge height ± 10 mm N.A Total height (i.e. height of side panels) + 610 mm
RequiredTotal height (i.e. height of side panels) + 760 mm
RequiredN.A Almirah/Cabinet size ± 5 mm 760 mm x 405 mm x 750 mm 760 mm x 405 mm x 750 mm
Required760 mm x 405 mm x 1000 mm
Required760 mm x 405 mm x 1220 mm
Required760 mm x 405 mm x 1525mm
Required760 mm x 405 mm x 1650 mm
RequiredN.A Verandah size 1800 mm x 1800 mm * MISCELENIOUS Number of Door hinges 2 nos. * Number of Door handles 2 nos. (1 no. each inside and outside) * Number of Tower bolt 1 nos. * Number of Aldrop on each door 1 nos. * safety Grills (for windows) Made from MS square bar of 8 mm having equal spacing of 125 mm * 9/13 Position of door On one of the longer side * Electric fittings Only electric points to be provided for one fan - One light - One bulkhead fitting point - one 5 amp. power point with Switch board including Double pole MCB 20A with metal enclosure - continuous earth wires to be provided and also external earth terminal to be provided. Only electric points to be provided for one fan - One light - One bulkhead fitting point - one 5 amp. power point with Switch board including Double pole MCB 20A with metal enclosure - continuous earth wires to be provided and also external earth terminal to be provided.
RequiredTo be supplied alongwith 1 no. ISI marked 355 mm Wall fan with its fittings - 2 nos. 8 watt LED bulbs - one exhaust fan - Fitting and Fixtures for wall fan & exhaust fan and LEDs - 1 no. switch panel/board - 1 no. light plug point to charger.
RequiredOnly electric points to be provided for one fan - One light with switch board for room and one electric point for light in verandah with switch board.
RequiredProvision for 3 nos. tube light (18 Watt LED light) - 2 nos. wall mounted ceiling fan (300 mm) - 3 nos. plug and socket (3 pin 5 amps electric plug socket)- 1 no main input socket (32 Amp heavy duty 3 pin power socket with MCB)- split AC (1.5 T) provision
RequiredN.A Number of Doors 1 * Number of Windows 2 nos. windows 1 no. window
Required2 nos. windows Doors (against water ingress in closed condition) Others * Roof slope 1 : 4 (approx) Self Draining Type * Door opening External * 10/13 Roof ridge N.A To be made out from 0.45 mm thick PPGI sheet.
RequiredN.A Flashing item (U track
RequiredL corner etc) N.A To be made out with 0.45 mm thick PPGI sheet in require size and shape.
RequiredN.A Locking/Security Cabin have to be provision of locking Door and Windows to prevent unwanted intrusion and theft. Cabin have to be provision of locking Door and Windows to prevent unwanted intrusion and theft.
RequiredN.A Overall covered area by Roof ± 10 mm 3050 mm x 3960 mm * COLOUR AND FINISH Colour As per Buyer's choice White
RequiredGreen
RequiredBlue
RequiredGrey
RequiredAs per Buyer's choice Top coat Chlorinated rubber paint 50 microns. Chlorinated rubber paint 50 microns.
RequiredBituminous paint.
RequiredN.A Paint outside Two coats of synthetic enamel paint to be applied on expose structure and all MS items after installation. Two coats of synthetic enamel paint to be applied on expose structure and all MS items after installation.
RequiredWeather texture roller paint
RequiredAll exterior panels to be white and Blue texture excluding the acrylic polycarbonate and aluminium frames.
RequiredAs per Buyer's choice
Required1 coat primer and 2 coats of enamel exterior paint(colour as per buyer's choice)
RequiredN.A Inside finish As per Buyer's choice Internal panels - doors - ceiling - shutter to be white finish (excluding polycarbonate/acrylic glass sheet and aluminium frames on windows)
RequiredWeather texture roller paint.
RequiredWall internal cladding by 50 mm thick glasswood with 6 mm prelaminated plywood with white colour sunmica fixed with aluminium stiffener and rivets
RequiredAs per Buyer's 11/13 choice Logo (if any) Approved logo of desired size to be painted as per Buyer's requirement. Approved logo of desired size to be painted as per Buyer's requirement.
RequiredNo logo WARRANTY Guarantee/Warranty of bought out components OEMs guarantee warranty of all Bought out components to be extended to the user unit - Seller have to submit related documents to the Buyer alongwith supply of Goods. * Service Maintenance Replacements/repairs to be borne by the seller in respect of fittings and fixtures during guarantee warrantee period. * Warranty 1 - Year * CERTIFICATION Test reports to be furnished to buyer's on demand Yes Yes
RequiredNo OEM of offered product is ISO 9001:2015 certified No Yes
RequiredNo OEM of offered product is ISO 14001:2015 certified Yes Yes
RequiredNo OEM of offered product is ISO 18001:2007 certified Yes Yes
RequiredNo * Bold specifications are the golden parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.