Loading…
Loading…
Tender Value
₹59.5 L
EMD Value
₹1.2 L
Closing Date
18 Mar 2026, 4:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
ELECT.G
17 conditions · 5 needing a document upload
Financial Eligibility Criteria: (Ref: RB letter No. 2022/CE-I/CT/GCC- 2022/POLICY : Advance Correction Slip No.-1 dt 14.07.2022) The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-I, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The intending tenderers should possess a valid electrical contractor license at the time of opening of tender, issued by any state government & same should be submitted along with tender documents by all bidders including working contractors of this unit otherwise offer shall be summarily rejected....... IT SHOULD BE NOTED BY THE TENDERER THAT ELECTRICAL LICENSE UNDER RENEWAL AT THE TIME OF TENDER OPENING WILL NOT BE CONSIDERED AND OFFER WILL BE SUMMARILY REJECTED. IT IS THE RESPONSIBILITY OF TENDERER TO UPLOAD VALID ELECTRICAL CONTRACTOR LICENSE ON THE DATE OF TENDER OPENING.
All requisite documents mentioned in clause 3.7 of the tender document attached pertaining to constitution of firm/concern. (As applicable).
33 conditions · 4 needing a document upload
The rate to be quoted by tenderer shall be inclusive of all state/central taxes including GST. THE TENDERER SHOULD UPLOAD VALID GST REGISTRATION CERTIFICATE ALONG WITH THE OFFER.
The tender shall comply with General Condition of contract (GCC),2022 of Indian Railways (file attached). and its latest amendment, if any. The tenderer shall submit the offer after duly satisfying himself/herself with the GCC,2022 in general.
Tenderers are required to upload the Bank details as per Annexure-XII (Real Time Gross Saving (RTGS)/National Electronic Fund Transfer (NEFT) Model Mandate Form)of tender document.
Tenderers are required to upload requisite details as per Annexure-VIIB (DETAILS OF CONTRACTUAL PAYMENT RECEIVED IN LAST THREE FINANCIAL YEARS AND CURRENT FINANCIAL YEAR) without which the offer is liable to be rejected.
Tenderers are compulsorily required to upload Affidavit as per Annexure-XXIV along with tender document, without which the offer will be considered incomplete and will be rejected summarily.
All requisite documents/credentials mentioned in clause 3.5 of the tender document attached pertaining to his/their technical and financial eligibility. (As applicable).
All requisite documents mentioned in clause 3.7 of the tender document attached pertaining to constitution of firm/concern. (As applicable).
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
No post tender correspondence for submission of additional documents shall be entertained after opening of the Technical & Commercial offers. Even suo-moto post tender letters of the tenderer/s shall be treated as Null & Void.
Defective parts shall only be replaced with OEM's spares. Proper invoices/delivery challan /warranty certificate etc. shall be provided by the firm to prove genuineness of spare parts.
This tender complies with Public Procurement Policy (Make in India) Order 2017, dated 15/06/2017, issued by Department of Industrial Promotion and Policy, Ministry of Commerce, circulated vide Railway Board letter no. 2015/RS(G)/779/5 dated 03/08/2017 and 27/12/2017.
IF ANY DISCREPANCY IS FOUND IN THE TENDER DOCUMENT, NAMELY SOR ITEM DESCRIPTION, SPECIAL TENDER CONDITION ETC., CLARIFICATION CAN BE SOUGHT FROM THE OFFICE OF SRDEE/G/DLI, DRM OFFICE, STATE ENTRY ROAD, NEW DELHI.
This tender complies with Railway Board instructions for Startups (recognized by Department of Industrial Policy and Promotion, Ministry of Commerce and Industry) for exemption from payment of Bid Security as detailed in GCC 2022 as amended from time to time. Such Startup firms may note that no other exemption is applicable to them in this particular tender.
On account payment, contractor shall submitted indemnity bond with validity up to the completion/extended period in the prescribed format (please refer Annexure-XXVIII) at the contractor's cost, vesting the ownership of such material with the railways.
The site of work is at Subzi Mandi, Muzaffar Nagar, Faridabad, Jind, Nangloi, Palwal, Sahibabad, Adarsh Nagar, Karnal, Faridabad Town, Ballabhgarh, Deoband, Sonipat, Rohtak, Meerut Cantt, Shakurbasti, Meerut City, Bahadurgarh, Panipat & Gurgaon Railway Stations of Delhi Division. However, site can be changed anywhere in Delhi Division, if required.
Electrical work in connection with provision of video surveillance system at stations over DLI Division.
57-SRDEE-G-DLI-2025-26
57-SRDEE-G-DLI-2025-26
Open
Works - General
6 Months
Delhi, Delhi
₹0
₹1.2 L
18 Mar 2026
24 Feb 2026
4 Mar 2026
41 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 59,48,047 | ||
| — | 980.00 | — | — | ||
| Supply and recessing/fixing of PVC conduit pipe of 25mm size conforming to IS:9537 Part-III:1987 (or Latest version) with accessories junction box, bends etc. including making chase, plastering/clamping etc. as per site requirement conforming to IS 9537 (Part 3): 1983 or latest & as per Explanatory Note. | — | — | — | 30,380 | |
| — | 1100.00 | — | — | ||
| Supply, Fixing, testing & commissioning of following sizes FRLS PVC insulated multi stranded copper (annealed) conductor single core cable conforming to IS 694 (or Latest Version) , and drawing in Laid (recessed /surface) PVC conduit pipe for wiring of point wiring / circuit wiring / sub main / main as required including connections, testing and commissioning & as per Explanatory Note. Size = 1x1.5 sq.mm. | — | — | — | 15,400 | |
| — | 2500.00 | — | — | ||
| Supply, Fixing, testing & commissioning of following sizes FRLS PVC insulated multi stranded copper (annealed) conductor single core cable conforming to IS 694 (or Latest Version) , and drawing in Laid (recessed /surface) PVC conduit pipe for wiring of point wiring / circuit wiring / sub main / main as required including connections, testing and commissioning & as per Explanatory Note. Size 1x4.0 sq.mm. | — | — | — | 67,500 | |
| — | 1000.00 | — | — | ||
| Supply, Fixing, testing & commissioning of following sizes FRLS PVC insulated multi stranded copper (annealed) conductor single core cable conforming to IS 694 (or Latest Version) , and drawing in Laid (recessed /surface) PVC conduit pipe for wiring of point wiring / circuit wiring / sub main / main including connections, testing and commissioning & as per Explanatory Note. Size = 1x10.0 sq.mm. | — | — | — | 76,000 | |
| — | 500.00 | — | — | ||
| Supply, fixing , testing & commissioning of UPVc drain pipe size 25mm dia. complete with all accessories. Preferred make: AKG, Rajgold, Supreme, Finolex or equivalent of reputed brand and of latest relevant IS & as per Explanatory Note. | — | — | — | 78,000 | |
| — | 86.00 | — | — | ||
| Supply, fixing, testing & commissioning of 25A, 2P 30mA RCBO AC type confirming to IS 12640-2 & IEC 61009-1: latest complete & as per Explanatory Note. | — | — | — | 1,79,138 | |
| — | 12.00 | — | — | ||
| Supply, fixing, testing & commissioning of 63A, 4P 30mA RCBO AC type confirming to IS 12640-2 & IEC 61009-1: latest complete & as per Explanatory Note. | — | — | — | 41,352 | |
| — | 10.00 | — | — | ||
| Supply, Fixing, testing & commissioning of LT distribution board double door type made up of CRCA sheet sheet with anti corrosion treatment and suitable, IP 43 phosphatised powder painted complete with neutral link, earth point, Din rail and prewired confirming to IS:13032, IEC 60947 & IS/IEC:61439 or latest of make ABB, Siemens, L&T, Schneider, Legrand or equivalent with following items of matching make to be fixed in distribution board, confirming to IS/IEC:60898-1 :2002 or latest, IE rules and site requirement. It should be rodent entry proof. It should also include well dressing and coding of circuit & as per Explanatory Note 63A DP RCBO 30 mA= 01 No. (Incoming) 6-32A MCB SP "C" Series = 09 Nos. (Outgoing) It should be rodent entry proof. It should also include well dressing and coding of circuit IP2X terminal , reversible door with 180 degree opening, cement spill protection, detachable gland at top and bottom and short link for MCBs. It should also include proper tagging on electrical wires/cables which clearly indicate the incoming point or source and outgoing point of wires/cables. | — | — | — | 65,590 | |
| — | 10.00 | — | — | ||
| Supply, Fixing, testing & commissioning of LT distribution board double door type made up of CRCA sheet sheet with anti corrosion treatment and suitable, IP 43 phosphatised powder painted complete with neutral link, earth point, Din rail and prewired confirming to IS:13032, IEC 60947 & IS/IEC:61439 or latest of make ABB, Siemens, L&T, Schneider, Legrand or equivalent with following items of matching make to be fixed in distribution board, confirming to IS/IEC:60898-1 :2002 or latest, IE rules and site requirement. It should be rodent entry proof. It should also include well dressing and coding of circuit & as per Explanatory Note 63A 4P RCBO 30 mA= 01 No. (Incoming) 6-32A MCB SP "C" Series = 09 Nos. (Outgoing) It should be rodent entry proof. It should also include well dressing and coding of circuit IP2X terminal , reversible door with 180 degree opening, cement spill protection, detachable gland at top and bottom and short link for MCBs. It should also include proper tagging on electrical wires/cables which clearly indicate the incoming point or source and outgoing point of wires/cables. | — | — | — | 93,140 | |
| — | 730.00 | — | — | ||
| "Refrigerant Piping" Supply & Installation of interconnecting suitable sizes of one end expanded refrigerant copper pipe work, insulated with 13mm thick (pipe size upto 19.1mm dia) & 19mm thick (pipe size above 19.1mm dia) closed cell electrometric nitrile rubber tubular insulation with alluminium foil between each set of indoor & outdoor units with outer mechanical protection for all exposed pipes as per specification. All piping inside the room shall properly run in MS/GI supports and hangers etc. as reqd. and perforated cable tray as mentioned below for exposed pipes and in the shaft & as per Explanatory Note. 15.9mm dia with 13mm thick nitrile rubber insulation: 18G | — | — | — | 7,54,820 | |
| — | 480.00 | — | — | ||
| "Refrigerant Piping" Supply &Installation of interconnecting suitable sizes of one end expanded refrigerant copper pipe work, insulated with 13mm thick (pipe size upto 19.1mm dia) & 19mm thick (pipe size above 19.1mm dia) closed cell electrometric nitrile rubber tubular insulation with alluminium foil between each set of indoor & outdoor units with outer mechanical protection for all exposed pipes as per specification. All piping inside the room shall properly run in MS/GI supports and hangers etc. as reqd. and perforated cable tray as mentioned below for exposed pipes and in the shaft & as per Explanatory Note. 9.5mm dia with 13mm thick nitrile rubber insulation: 18G | — | — | — | 3,06,240 | |
| — | 250.00 | — | — | ||
| "Refrigerant Piping" Supply &Installation of interconnecting suitable sizes of one end expanded refrigerant copper pipe work, insulated with 13mm thick (pipe size upto 19.1mm dia) & 19mm thick (pipe size above 19.1mm dia) closed cell electrometric nitrile rubber tubular insulation with alluminium foil between each set of indoor & outdoor units with outer mechanical protection for all exposed pipes as per specification. All piping inside the room shall properly run in MS/GI supports and hangers etc. as reqd. and perforated cable tray as mentioned below for exposed pipes and in the shaft & as per Explanatory Note. 6.4mm dia with 13mm thick nitrile rubber insulation: 18G | — | — | — | 1,12,250 | |
| — | 350.00 | — | — | ||
| Supply, laying, testing and commissioning of communication cable (1.5 sq. mm x 2 core) complete & as per Explanatory Note. | — | — | — | 62,300 | |
| — | 350.00 | — | — | ||
| Supply, fixing, testing and commissioning of suitable size interconnecting control cable size (5Cx6.0 sq. mm.) from indoor to outdoor unit complete with suitable size copper earthing as per latest relevant IS & IE rules and site requirement & as per explanatory note. | — | — | — | 1,22,150 | |
| — | 26.00 | — | — | ||
| Supply, installation, testing and commissioning of Air Curtain of size 1200x230x212 mm complete as per site requirement and latest relevant IS and IE & as per Explanatory Note. | — | — | — | 4,16,000 | |
| — | 25.00 | — | — | ||
| Supply, fixing, testing and commissioning of Complete Panel Solution for remote monitoring and controlling of 02 Nos. air conditioning units (window/split) including individual relay/contactor of 40A rating each. 02 PT100 CLASS-B temperature sensors. Compact energy meter with display, covering direct current, voltage and energy parameters in compliance to IEC 61000-4-2 & IEC 61000-4-5. Suitable Modular PLC with inbuilt HMI having 5DI, 8DO, 2A (impedance input of 750 ohm) with software (IEC 61131-3). Din Rail SMPS-i/p 100-270V Ac o/p 24V DC, current rating -2.5 A with up to 140% of rated output current; Hiccup type auto recovery and O/C, O/V, S/C protection, Size 43x110x103mm (WxHxD), Serial (Modbus) to cloud connector device with MQTT and GSM (m2m sim card support). ABS/MS/Polycarbonate panel box IP 67, IK10, Outdoor type and as per site requirement & as per Explanatory Note. | — | — | — | 21,59,175 | |
| — | 10.00 | — | — | ||
| Supply, fixing, testing and commissioning of Complete Panel Solution for remote monitoring and controlling of 04 Nos. air conditioning units (window/split) including individual relay/contactor of 40A rating each. 02 PT100 CLASS-B temperature sensors. Compact energy meter with display, covering direct current, voltage and energy parameters in compliance to IEC 61000-4-2 & IEC 61000-4-5. Suitable Modular PLC with inbuilt HMI having 5DI, 8DO, 2A (impedance input of 750 ohm) with software (IEC 61131-3). Din Rail SMPS-i/p 100-270V Ac o/p 24V DC, current rating -2.5 A with up to 140% of rated output current; Hiccup type auto recovery and O/C, O/V, S/C protection, Size 43x110x103mm (WxHxD), Serial (Modbus) to cloud connector device with MQTT and GSM (m2m sim card support). ABS/MS/Polycarbonate panel box IP 67, IK10, Outdoor type and as per site requirement & as per Explanatory Note. | — | — | — | 11,09,140 | |
| — | 86.00 | — | — | ||
| Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB "C" curve including connections, painting etc. as required (For AC's). CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 & as per Explanatory Note | — | — | — | 62,522 | |
| — | 26.00 | — | — | ||
| Earthing with 40 mm dia GI pipe class 'B' 4.5 meter long earth electrode as per IS:3043 (latest version) to achieve earth resistance less than 5 ohms including construction of masonry enclosures with hinged cover plate of cast iron with locking arrangement (approx. size 400 mmx 400 mm) on top, provision of earth plate, connections from earth electrode to switch gear/pole as per drawing & as per Explanatory Note. | — | — | — | 1,78,230 | |
| — | 130.00 | — | — | ||
| Supplying and laying 25 mm X 5 mm G.I strip confirming to relevant IS as per IS:3043 (Latest version), fixing on surface or as per site condition, clamping or fixing with suitable arrangement as per site requirement, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm) & as per Explanatory Note. | — | — | — | 18,720 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC-2022-ACS10_merged.pdf GCC 2022 along with ACS
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .