Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.8 LAccepted-AOC ATR MAIN ROAD GARACHARMA II OPP MAHINDRA JADWET SHOWROOM SRI VIJAYA PURAM 744105 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹44.5 L+₹1.7 L (4.08%)Rejected-Finance OPP CCS GARACHARMA PORT BLAIR 744105 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L2 | Rejected-Finance Other Than Lowest | |
| 3 | L3₹45.0 L+₹2.2 L (5.12%)Rejected-Finance | L3 | Rejected-Finance Other Than Lowest | |
| 4 | L4₹45.5 L+₹2.7 L (6.30%)Rejected-Finance | L4 | Rejected-Finance Other Than Lowest | |
| 5 | L5₹45.9 L+₹3.1 L (7.16%)Rejected-Finance NEAR OLD CCS JUNGLIGHAT SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L5 | Rejected-Finance Other Than Lowest |
Tender Value
₹44.5 L
EMD Value
₹89,000
Closing Date
11 Jul 2023, 6:00 pmClosed
Garrison Engineer Brichgunj
Garrison Engineer Brichgunj
PROVN OF FAMILY WELFARE CENTRE AT VAYU VIHAR BROOKSHABAD AND RAINWATER SHED INCLUDING CONNECTED BR AND EM WORKS OVER LAMBALINE ENTRANCE GATE AT AF STATION UNDER GE BRICHGUNJ PORT BLAIR
2023_MES_604276_1
8368A
Open Tender
Civil Works
Item Rate
180 days
Brichgunj
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer Brichgunj
₹89,000
Yes
1 Sept 2023
19 Jun 2023
13 Jul 2023
19 Jun 2023
11 Jul 2023
5 Jul 2023
19 Jun 2023 - 3 Jul 2023
Amount
M & L Excavating over areas, n exc 1.5 m deep and getting out Hard / Dense Soil.
All as per item No.1 here in before but for each additional 1.5m or part thereof in depth beyond the first 1.5 m and getting out Hard/Dense Soil.
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth, for foudation etc, or for shafts, wells cesspits, manholes, pier holes etc n exc 10 sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil.
M&L PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filling.
M & L for RCC- M - 30 Design Mix as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete all as specified and directed
M&L Reinforced cement concrete (design mix M-30 grade using 20mm graded aggregate) above top of footings including attached pilasters and buttresses
M & L for RCC- M -30 Design Mix as in columns, pillars, piers,posts and struts as specified and directed
M & L for RCC- M -30 Design Mix as in beams, cantilevers,bressummers, lintels over 1.5m span as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm
Removing excvated soil to a distance n.exc 50 m and depositing as directed
Use and waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for fair finished surfaces.
M & L for Use and waste of form work to sides of pillars, posts, struts, piers, columns and stanchions
Use and waste of form work to sides and sofit of Beams for Fair finished surfaces.
M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
All as per item no 14.00 here in before but TMT bars 6 mm to 8mm dia cut to length bent to shape required and binding with mild steel wire annealed not less than 0.9 mm dia.
All as per item no 14.00 here in before but 5mm dia and over up to and including 10mm dia as in stirrups, spacers, binders and the like
M&L Precast Cement Concrete Block Masonry with Solid Block, exc 10cm in width in type C-1, 1:3:6 (using 20mm graded stone aggregate) set in CM (1:6) all as specified.
M&L for 40mm thick Damp proof course in cement concrete 1:2:4 type B-O to horizontal or vertical surface including necessary formwork
M&L Rendering 10mm thick on concrete surfaces in CM (1:6) finished even & smooth without using extra cement.
M&L Rendering 5mm thick in CM 1:3 on soffits of RCC slabs, roof projections, soffits and sides of RCC beams, waist slab, Loft Slab, RCC shelves, Chajjas, and the like finished even and smooth without using extra cement.
M&L 15mm thick rendering in two layers of 10mm thick backing coat in CM 1:6 and 5mm thick floating coat in CM 1:4 mixed with water proofing compound on all external wall surfaces finished even and smooth without using extra cement. (Note : Water proofing compound shall be measured and paid seperately)
Supply only integral WPC (3% by wt of cement).
M&L preparation of newly plastered surfaces of wall and applying two coats of Oil Bound distemper over a coat of primer over a coat of internal wall care putty as specified and directed.
All as per item no 23.00 here in before but on Ceiling surfaces
M& L for Finishing walls with Acrylic smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) etc complete all as specified and as directed by Engineer-in-Charge.(Make Apex Ultima)
M&L Filling under floors or in foundations including watering and consolidation
Surface excavation n. exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out in hard/ dense soil.
M&L Hard Core of gauge n.exc. 63mm deposited spread and levelled in layers n.exc. 15 cm thick watered and rolled/ rammed to a true surfce.
M&L PCC 1:4:8 type D-2 using 40 mm graded stone aggregate in 75mm thick as in sub base.
M&L PCC 1:2:4 type B-1 using 20 mm graded stone aggregate in 40mm thick.
M&L PCC 1:3:6 type C1 using 20mm graded aggregate of 75 mm thick as in Plinth Protection.
M & L Chequered cement concrete tiles, with grey cement and pigment 30cm x 30cm x 20mm thick set, jointed and pointed in neat cement slurrry in floors including 20mm thick screed bed in Cm 1:4 all as specified and directed.
M&L Coloured Non-Skid Ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.18 Sqm but not exceeding 0.36 Sqm in floor etc,set and jointed in neat cement sluryy and pointed in coloured cement to match as in floor over 15mm thick screed bed in CM (1:6) all as specified.
All as per Item No -32 here in before but as in Dado/Skirting/Steps etc set and jointed in neat cement slury and pointed in coloured cement to match all as specified and directed including backing coat 10mm thick in CM 1:6 all as specified.
Material and labour for anodized aluminium sections (minimum anodisation 15 micros) for partitions, window and door with frame and shutters fully or partially glazed, side Hung type ( two numbers glazed and gauzed) without sash bars, with panel inserts of sheet glass, gauze including necessary jointing cleats, glazing clips, rubber beading, Neoprene packing, anodized aluminium snap beading, screws,i max hinges, butt hinges etc. The size of aluminium sections shall be all as specified in relevant IS code and SSR part-I and completed all as specified and as directed by engineer-in-charge. (Note: (i) supply only panel inserts of glass/gauze, handles, tower bolts and sliding bolt will be measured and paid separately as supply only. (ii) Weight of aluminium section only shall be accounted for payments purpose. However, until rate quoted shall be deemed to include for cost of rubber beading, glazing clips, neoprene packing and fixing only of panel inserts of glass/ particle board/gauze, handles, hinges, sliding bolts, tower bolts etc.)
Supply only 12 mm thick Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination and fixed to aluminium frames complete all as specified and as directed by Engineer -in-Charge.
Supply only 4.0mm thick sheet glass, ordinary quality in squares n exc 0.50 sq.m in each panel.
S&F 100 Butt hinges extruded aluminium alloy, anodised. With galvanished mild steel hinge pin , anodised and fixed type B-21
S&F Aluminium alloy anodised sliding door bolt with hasp, staple (bolt type) 300 mm long and fixing clips to sheet cast or extruded sections and fixing bolt or cast aluminium alloy complete all as specified.
S&F Aluminium anodised barrel tower bolt of extruded section of size 150mm long complete all as specified.
S&F Aluminium anodised barrel tower bolt of extruded section of size 100mm long complete all as specified.
S&F 100 mm long extruded aluminium alloy anodised handles fabricated type complete all as specified.
S&F 150mm long extruded aluminium alloy anodised handles fabricated type complete all as specified.
S&F for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to Fe-410-W grade E 251 Quality B complete all as specified and directed.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240
Mild steel bolts of diameter of neck exc 12mm and n.exc 20mm, purpose made with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut n exc 30cm long as specified.
Preparation of new or previously untreated steel surfaces & applying a two coats of synthetic enamel paint over a coat of red oxide primer over 10cm in width or girth,not otherwise described.
S&F 0.50 mm thick pre painted galvalume aluminium zinc coating GI based corrugated steel sheet of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self taping screws as specified.
S&F 0.50 mm thick pre painted galvalume aluminium zinc coating GI based plain steel sheet of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self taping screws as specified.
S&F MS works as in wind ties for roof incl securing bolts etc complete all as specified and as directed.
S & F for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165
M&L Painting to new steel and iron surfaces of n exc 10cm wide or girth by two coats of synthetic enamel paints over a coat of red oxide primer including preparation complete all as specified and as directed.
Material and labour for false ceiling with aluminium grid work (Size of grid 600x600 mm) with 35 x 25 x 1.5 mm main tee and 25 x 25 x 1.4 mm cross tee and wall angle and suspended with 2mm dia GI wire hooked to roof with needful adjustment bolts at an interval of 1.20 m centre to centre staggered and board with Eco board decorative type size 600 x 600 x 4 mm thick finished with two coats of oil bound distemper over a coat of primer on exposed surfaces all as specified and directed by Engineer-in-Charge.
M&L PCC 1:4:8 type D-2 using 40 mm graded stone aggregate in 100mm thick as in sub base.
M&L 25mm thick cement concrete type B-0 (12.5mm graded stone aggregate) as in RCC roof / Floor surface wfor level coarse
M&L Coloured Non-Skid Ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floor etc,set and jointed in neat cement sluryy and pointed in coloured cement to match as in floor over 20mm thick screed bed in CM (1:6).
All as per Item no 56.00 here in before but as in wall for Skirting/Dado over 10mm thick Backing Coat in CM (1:6).
M&L Preparation of Newly Plastered surfaces of Wall and applying Two coats of Oil Bound Distemper over chalk whiting including primer as specified and directed.
M& L for Finishing walls with Acrylic smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) etc complete all as specified and as directed by Engineer-in-Charge.(Make Apex Ultima)
M & L For Providing and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth.
S&F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165,
S&F framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel')
Mild steel screw bolts, diameter of neck in 16 to 20mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 10cm and n exc 15cm long
M&L for two coats of synthetic enamel paints over a coats of red oxide primer including prepration of new steel surfaces of any description over 10 cm in width or girth not otherwise described
Design, Supply and fixing at site of the TRAY PANEL SCREW type system with aluminium composite panel of approved colour on exterior walls, columns, MS structure, ceiling, coping, slab projectons at all heights and elevation including necessary aluminium framework. The aluminium composite panel should 4 mm thick consist of 3mm thick thermoplastic core of anti toxidant LDPE sandwitched between 2 skins of 0.5mm thick aluminium alloy sheet making a total panel thickness of 4mm. The external surface shall be finshed with PVDF based coating on the top side and service coating on the reverse side shall be with a polymer paint. NOTE:- The system shall be designed to withstand a wind pressure of 190 kg/Sqm with necessary Alu. sub frames, cleats and shall be fixed to the masonry/ RCC walls/ MS structure with necessary clamps, galvanized M.S brackets and anchor fasteners. All clamps and brackets shall be Hot dip galvanized minimum 80 microns thick and shall conform to IS: 4759-1996. Any other acessories such as fastening straps, nuts, bolts, rivets, washers, etc. other than anchor system shall be in Indian standard grade. all joints of ACP must be sealed with approved sealent of approved colour. sealant make DOW CORNING 789 weather sealant. Rate shall include to provide open cell polyethylene backer rods, weather sealant etc, all materials and labour complete.
S&F PVC (SWR) pipes 150mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors or in walls including band as required complete all as specified
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft / loose soil all as specified and directed.
M&L for PCC 1:2:4 type B2, using 40mm graded aggregate of 100mm thick as in hardstanding and footpath.
M&L for 60mm thick coloured machine pressed precast concrete interlocking paver block glossy finished any size and shape conforming to IS 15658-2006 , M-35Grade with grey cement and pigment over sand filling complete all as directed. ( Cost of Sand will be measured and paid separately)
M & L for Sand filling under floors or in foundations including wateringand consolidation complte all as specified.
M&L For Point wiring complete with 1.5 sqmm single core FRLS PVC insulated and unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC casing and caping and all accessories fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper cable green in colour as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover for housing the switches, socket outlets, fan regulators etc., all as specified and as directed for one light point controlled by one one way switch.
All as per item No. 71 here - in - before but for one fan point controlled by one 5 Amps switch.
All as per item No. 71 here - in - before but for 5 Amps switch socket point on the same board controlled by one switch.
All as per item No. 71 here - in - before but for 3 pin switch socket outlet point 5 amps on independent board.
Supply and fix switch piano flush button single pole oneway 5 amp.
Supply and fix switch socket outlet 3 & 2 pin (multi pin) 5 amp flush type.
All as per item No 71 here-in-before but for 3 pin 15 Amps switch socket combination on independent board with 4 sq mm copper cable and provision of 4 sq mm FRLS PVC insulated stranded copper conductor cable for earth continuity conductor connected to common earth dolly connecting upto fittings
Supply and fix switch socket outlet multipurpose 3 pin 15 and 5 amp controlled by one switch, flush type.
Supply and fix ceiling rose surface bakelite 65x50mm 3 terminal
Supply and fix fan speed regulator, electronic suitable socket type for single phase AC, 240 volts, 50 Hz,100 watts, complete all as specified and as directed by Engineer-in-Charge Make:-Anchor/Havells/Bajaj
Supply and fixing LED lights fitting 1x 22W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
S&F 25 W New genration energy saving & envoirmental friendly long life versatile pressure dia cast aluminium IP65 road way luminaire with high power LEDs as light and electronic driver complete with necessary brackets (made out of 25 mm bore GI light grade pipe approx. 0.6 M long) nuts, bolts etc to be fixed as on walls complete as directed.
Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor.complete all as as specified and as directed.
Supply and fix metal enclosure distribution board TPN 4 way 415 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs, complete all as as specified and as directed.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning.
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) TPN 16 to 32 Amps and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fix exhaust fans electric driven AC single phase 230 volts 300 mm sweep with louvers including grouting and making whole in wall, complete all as specified.
M&L for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less thab 1.5 Meter below normal ground level connected to GI wire 4 mm dia by means of bolts, nuts , check nuts and washers of GI and GI tubing 20 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1 pre cast RCC (1:2:4) type B1 cover slab 54 x 54 x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing (LG) for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed electrical plate No. 3 of SSR part - I
Supply and fix metal enclosure distribution board SPN, 8 way 240 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs, complete all as as specified and as directed.
Supply and fix in repair MCB single pole 240 volts, 6 to 32 amps "B" series complete all as specified and as directed by Engineer-in-Charge.
Supply and fix single pole and netural 240 Volts 6 To 32 amps complete all as specified and as directed by Engineer-in-Charge.
Supply, lay, test and commissioning under ground XLPE insulated and PVC sheathed, armoured heavy duty under ground cable, suitable for earthed system, laying in trenches/duct sleeving through pipe in duct, ISI marked with aluminium stranded conductor 1100 volt grade of cross section area 4 C x 25 sq mm
Supply, lay, test and commissioning under ground XLPE insulated and PVC sheathed, armoured heavy duty under ground cable, suitable for earthed system, laying in trenches/duct sleeving through pipe in duct, ISI marked with aluminium stranded conductor 1100 volt grade of cross section area 2 C x 10 sq mm
Supply & lay cable protection pipe of HDPE double wall corrugated (DWC) incl couplers,bends etc of size 50 mm OD and ID 38mm confirming to IS 14930 -II and ISI Marked all specified and directed.
Supply and fix Galvanished iron steel tubing of medium grade with all fittings of 25 mm dia in size.
Supply and fix Galvanished iron steel tubing of medium grade with all fittings 0f 20 mm dia in size
Supply and fix of Gun metal gate valve ISI marked with iron wheel head at both ends for iron pipes and fixed for the following sizes: (a) 20mm bore
Supply and fix of Gun metal gate valve ISI marked with iron wheel head at both ends for iron pipes and fixed for the following sizes: ( b) 25mm bore
Cutting the existing water main 40mm dia and insert 'T' reducer/ ferrule for taking branch connection size 25 mm including all materials as required and excavation, earth work complete.
Supply and Fix Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I ,Tank capacity 1000 Ltr along with float valve complete all as specified and directed
DEEPAK AGENCIES
M/s Kamal Electrical
Nirman Construction Company
SKV Engineering
M/s K Moorthi
P Babu
M/s Saina Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .