| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 LAdmitted-Finance | ₹2.5 L | L1 | Admitted-Finance |
| 2 | L2₹3.3 LAdmitted-Finance | ₹3.3 L | L2 | Admitted-Finance |
| 3 | L3₹3.3 LAdmitted-Finance CW 545 SANJAY GANDHI TRANSPORT NAGAR NEW DELHI 110042 | NORTH | DELHI | 110042 | ₹3.3 L | L3 | Admitted-Finance |
| 4 | Not Admitted-Finance | - | - | Not Admitted-Finance Others-FDR not submitted |
| Sl No | Description | Qty | Unit | Bansal Engineers and Traders L2 | Devraj Enterprises L3 | K R ELECTRICAL L1 |
|---|---|---|---|---|---|---|
| 1.01 | Wiring for light point/fan point /exhaust point/ call bell point withsq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. DSR Civil 2022 Code 1.8.3 Group C | 15 | Nos. | 5,250 ₹6,195 | 11,250 ₹13,275 | 2,250 ₹2,655 |
| 1.02 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required. Group - 31.15.3/DJB SOR 2025 | 22 | Nos. | 8,800 ₹10,384 | 16,500 ₹19,470 | 5,500 ₹6,490 |
| 1.03 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required DSR Civil 2022 Code 1.17.12 | 200 | Mtrs. | 22,000 ₹25,960 | 17,000 ₹20,060 | 17,000 ₹20,060 |
| 1.04 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required DSR Civil 2022 Code1.17.21 | 200 | Mtrs. | 20,000 ₹23,600 | 20,000 ₹23,600 | 22,000 ₹25,960 |
| 1.05 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire DSR Civil 2022 Code 1.14.3 | 150 | Mtrs. | 50,100 ₹59,118 | 16,500 ₹19,470 | 37,500 ₹44,250 |
| 1.06 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door DSR Civil 2022 Code 2.3.1 | 2 | Nos. | 3,000 ₹3,540 | 3,300 ₹3,894 | 4,500 ₹5,310 |
| 1.07 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. DSR Civil 2022 Code 2.10.1 | 16 | Nos. | 3,200 ₹3,776 | 2,560 ₹3,020.8 | 3,840 ₹4,531.2 |
| 1.08 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. DSR Civil 2022 Code 2.10.2 | 15 | Nos. | 6,000 ₹7,080 | 7,800 ₹9,204 | 7,650 ₹9,027 |
| 1.09 | Supply of ceiling fan having size 1200 mm (48") in white colour . Make: Havells/Crompton/DJB approved make. DJB SOR Item no.20.1.3 | 5 | Nos. | 9,000 ₹10,620 | 7,900 ₹9,322 | 12,500 ₹14,750 |
| 1.10 | Supply of exhaust fan having size 300 mm , 1440 rpm . Make: Havells/Crompton/DJB approved make. DJB SOR Item no.20.2.1 | 4 | Nos. | 13,796 ₹16,279.28 | 11,400 ₹13,452 | 6,000 ₹7,080 |
Tender Value
Refer Docs
EMD Value
₹8,300
Closing Date
6 Mar 2026, 11:00 amClosed
Office of the Ex. Eng. (E and M) M-2
Pocket-A, Dilshad Garden, Delhi-110095
Replacement of electrification system at Yamuna Vihar Water Emergency
2026_DJB_287854_1
NIT No. 30 (25-26)
Open Tender
Miscellaneous Works
30 days
Yamuna Vihar BPS
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Ac No. 50448339804
₹8,300
16 Mar 2026
27 Feb 2026
6 Mar 2026
27 Feb 2026
6 Mar 2026
27 Feb 2026
Wiring for light point/fan point /exhaust point/ call bell point withsq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. DSR Civil 2022 Code 1.8.3 Group C
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required. Group - 31.15.3/DJB SOR 2025
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required DSR Civil 2022 Code 1.17.12
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required DSR Civil 2022 Code1.17.21
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire DSR Civil 2022 Code 1.14.3
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door DSR Civil 2022 Code 2.3.1
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. DSR Civil 2022 Code 2.10.1
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. DSR Civil 2022 Code 2.10.2
Supply of ceiling fan having size 1200 mm (48") in white colour . Make: Havells/Crompton/DJB approved make. DJB SOR Item no.20.1.3
Supply of exhaust fan having size 300 mm , 1440 rpm . Make: Havells/Crompton/DJB approved make. DJB SOR Item no.20.2.1
Supply of Led tubelight 24 W. Make: Havells/Bajaj/Crompton/DJB Approved make DJB SOR Item no.19.3.1
Supply of 70 W Led Street Light. Make: Havells/Crompton/Bajaj/DJB approved make DJB SOR Item no.19.10.6
Supply of 250 amp MCCB 3 Pole breaking capacity 36 KA . Make: L&T/Havells/DJB approved make
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. DSR E&M 2022 item no. 12.34
Providing and fixing 50 mm dia X 5.6 metres G.I. pipe (including accessories) complete with 50 mm X 50 mm X 6 mm angle iron cross arm and 40 mm X 3mm M.S. flat iron clamps bends for guard wire, 75 mm X 90 mm shackle insulator and straps, 7/ 3.15 mm G.I. wire stay set for house service connection including painting the angle and flat iron with primer and finish paint etc. as required. DSR E&M 2022 item No. 12.36
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.DSR item No, 1.41
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Also for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes 31.50.1 & 31.51/ DJB SOR 2025
stage.html
html • 0.03 MB
technical_381577.pdf
techsummary_381577.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.91 MB
BOQ_381577.xls
BOQ • 0.26 MB
NIT.pdf
Tender Documents • 0.90 MB