Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-AOC 1523 PHASE 10 SAS NAGAR PB | L1 | Accepted-AOC L-1 Bidder | |
| 2 | L-2₹6.4 L+₹13,500.70 (2.15%)Rejected-Finance | L-2 | Rejected-Finance Second Lowest Bidder | |
| 3 | L-3₹6.7 L+₹36,861.70 (5.86%)Rejected-Finance | L-3 | Rejected-Finance Third Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹14,000
Closing Date
1 Mar 2021, 4:00 pmClosed
SE EMCCIII, PTEP, Panki, Kanpur
Office of SE EMCCIII, PTEP, Panki, Kanpur
work of servicing and complete overhauling of departmental air conditioners, water coolers and ceiling fans of PTEP, Panki, Kanpur.
2021_RVUNL_549490_1
ET11PTEPEMCCIIIEMCDVIII2021
Open Tender
Electrical Works
Fixed-rate
365 days
Kanpur
Please refer Tender documents.
3 documents required · 3 mandatory
₹826
Dy CAO, CFA and BO, PTEP, Panki, Kanpur
₹14,000
Yes
25 Mar 2021
28 Jan 2021
2 Mar 2021
28 Jan 2021
1 Mar 2021
28 Jan 2021
28 Jan 2021 - 1 Mar 2021
Amount
Servicing /overhauling of air conditioners (window/split type of capacity 1.5/2.0 ton) make BlueStar/Voltas/LG/Carrrier/Videocon/kirloskar.
Servicing/overhauling of water coolers (capacity 40 to 150liters). Make: Blue Star/Voltas/LG/Carrrier/Videocon/kirloskar.
Periodic cleaning of tank & filter of water coolers (capacity 40 to 150 liters) Make: BlueStar/Voltas/LG/Carrrier/Videocon/kirloskar.
Periodic cleaning filter (plastic wire mesh) of air conditioner (window/split type of capacity 1.5/2.0 ton). Make: BlueStar/Voltas/LG/Carrrier/ Videocon/ kirloskar.
Replacement of damaged compressor unit for 1.5 ton / 2 ton air conditioner/Water cooler with new one (new compressor will be provided by the department free of cost and damaged compressor will be the property of department)
Replacement of damaged compressor unit for 1.5 ton Air conditioner (window/split type) with new one. New compressor will be provided by contractor at his own cost and damaged compressor will be property of department. Reciprocation type compressor
Replacement of damaged compressor unit for 1.5 ton Air conditioner (window/split type) with new one. New compressor will be provided by contractor at his own cost and damaged compressor will be property of department. Rotary type compressor
Replacement of damaged type compressor unit for 2 ton Air conditioner (window/split type) with new one. New compressor will be provided by contractor at his own cost and damaged compressor will be property- Reciprocation type compressor
Replacement of damaged type compressor unit for 2 ton Air conditioner (window/split type) with new one. New compressor will be provided by contractor at his own cost and damaged compressor will be property of department. Rotary type compressor
Replacement of damaged compressor unit for water cooler with new one of capacity 40 to 150 liters (new compressor will be provided by the contractor at his own cost and damaged compressor will be the property of the department)
Replacement of condenser coil of 1.5 ton air conditioner. New condenser coil will be provided by contractor at his own cost
Replacement of condenser coil of 2.0 ton air conditioner New condenser coil will be provided by contractor at his own cost
Repairing of condenser coil of 1.5/2.0 ton air conditioner
Fabrication & Installation of outer metallic cover frame of the air conditioner.
Denting, welding and repairing and painting of water coolers (capacity 40 to 150 liters).
Transportation charges for shifting of air conditioner (window/split type of capacity 1.5/2.0 ton) from one place to another place within premise of PTEP, Panki.
Transportation charges for shifting of water cooler (capacity 40to 150liters) from one place to another place within premise of PTEP, Panki.
Gas charging for air conditioner (window/split type) of 1.5 ton capacity.
Gas charging for air conditioner (window/split type) of 2.0 ton capacity.
Gas charging for water cooler. 40 liter to 80 liter.
Gas charging for water cooler. 120 liter to 150 liter
Rewinding of blower motor of single speed AC (window/split (type).
Rewinding of blower motor of variable speed (window/split ac)
Rewinding of fan motor of water coolers. 40 liter to 80 liter.
Rewinding of fan motor of water coolers. 120 liter to 150 liter
Replacement of electronic PCB of 1.5/2.0 ton window/Split type air conditioner by new one.
Deployment of 01 AC technician and 1 helper for attending the complaint of AC/water cooler during emergency /visit of VIP at PTEP, Panki, Kanpur.
Replacement of various damaged parts with new one (of reputed make) of AC/water cooler(as per scope of work ) Running capacitor, 220/440V
Replacement of various damaged parts with new one (of reputed make) of AC/water cooler (as per scope of work ) Starting relay
Replacement of various damaged parts with new one (of reputed make) of AC/water cooler(as per scope of work ) overload relay SR-1622 or equivalent
Replacement of various damaged parts with new one (of reputed make) of AC/water cooler(as per scope of work ) Thermostat
Replacement of various damaged parts with new one (of reputed make) of AC/water cooler(as per scope of work ) Filter (Plastic wire mesh)
Replacement of various damaged parts with new one (of reputed make) of AC/water cooler(as per scope of work ) Metal tap for water cooler
Replacement of various damaged parts with new one (of reputed make) of AC/water cooler(as per scope of work ) Fan Blade
Replacement of various damaged parts with new one (of reputed make) of AC/water cooler(as per scope of work ) Water supply pipe for water cooler
Replacement of various damaged parts with new one (of reputed make) of AC/water cooler(as per scope of work ) Float valve for water cooler
Replacement of various damaged parts with new one (of reputed make) of AC/water cooler(as per scope of work ) Blower fan motor shaft
Replacement of various damaged parts with new one (of reputed make) of AC/water cooler(as per scope of work ) Blower fan motor bush
Replacement of various damaged parts with new one (of reputed make) of AC/water cooler(as per scope of work ) Front grill of window AC
Work of overhauling of automatic stabilizer 4 KVA/3KVA installed at VIP Guest House, VIP Residence and GM Building and in premises of PTEP, PANKI & Dispensary, Inter college.
Work of replacement of damaged parts with new one of automatic voltage stabilizer 4KVA/3KVA installed at VIP Guest House, VIP Residence and GM building, in premises of PTEP, (The damaged parts will be replaced with new one ,new parts will be arranged by the contractor at his own cost and taken out damaged parts will be property of department.) Main transformer of 3 KVA, AVS (Automatic Voltage Stabilizer, single Phase 220 V, 50 HZ.)
Work of replacement of damaged parts with new one of automatic voltage stabilizer 4KVA/3KVA installed at VIP Guest House, VIP Residence and GM building, in premises of PTEP, (The damaged parts will be replaced with new one ,new parts will be arranged by the contractor at his own cost and taken out damaged parts will be property of department.) Main transformer of 4 KVA, AVS (Automatic Voltage Stabilizer, single Phase 220 V, 50 HZ.)
Work of replacement of damaged parts with new one of automatic voltage stabilizer 4KVA/3KVA installed at VIP Guest House, VIP Residence and GM building, in premises of PTEP, (The damaged parts will be replaced with new one,new parts will be arranged by the contractor at his own cost and taken out damaged parts will be property of department.) Relay of 4KVA/3KVA, AVS
Work of replacement of damaged parts with new one of automatic voltage stabilizer 4KVA/3KVA installed at VIP Guest House, VIP Residence and GM building, in premises of PTEP, (The damaged parts will be replaced with new one, new parts will be arranged by the contractor at his own cost and taken out damaged parts will be property of department.) Single Change Over contactor 30 amp. of 4KVA/3KVA,AVS.
Work of replacement of damaged parts with new one of automatic voltage stabilizer 4KVA/3KVA installed at VIP Guest House, VIP Residence and GM building, in premises of PTEP, (The damaged parts will be replaced with new one, new parts will be arranged by the contractor at his own cost and taken out damaged parts will be property of department.) Time delay circuit of 4KVA/3KVA, AVS.
Work of replacement of damaged parts with new one of automatic voltage stabilizer 4KVA/3KVA installed at VIP Guest House, VIP Residence and GM building, in premises of PTEP, (The damaged parts will be replaced with new one,new parts will be arranged by the contractor at his own cost and taken out damaged parts will be property of department.) Main Electronic circuit of 4KVA/3KVA, AVS.
Work of replacement of damaged parts with new one of automatic voltage stabilizer 4KVA/3KVA installed at VIP Guest House, VIP Residence and GM building, in premises of PTEP, (The damaged parts will be replaced with new one, new parts will be arranged by the contractor at his own cost and taken out damaged parts will be property of department.) Circuit Transformer (240 V/9V) of 4KVA/3KVA, AVS.
Work of replacement of damaged parts with new one of automatic voltage stabilizer 4KVA/3KVA installed at VIP Guest House,VIP Residence and GM building, in premises of PTEP, (The damaged parts will be replaced with new one, new parts will be arranged by the contractor at his own cost and taken out damaged parts will be property of department.) ON/OFF Switch of 4KVA/3KVA, AVS.
Work of replacement of damaged parts with new one of automatic voltage stabilizer 4KVA/3KVA installed at VIP Guest House, VIP Residence and GM building, in premises of PTEP, (The damaged parts will be replaced with new one, new parts will be arranged by the contractor at his own cost and taken out damaged parts will be property of department.) 2-way switch of 4KVA/3KVA, AVS.
Work of overhauling of geyser(25 litre),220 V, single phase in guest house,V.I.P. Residence of officers colony PTEP
Replacement of following damaged parts with new one of geyser (The damaged parts will be replaced with new one, new parts will be arranged by the contractor at his own cost and taken out damaged parts will be property of department. Heating coil 1500 watt ,250V
Replacement of following damaged parts with new one of geyser (The damaged parts will be replaced with new one, new parts will be arranged by the contractor at his own cost and taken out damaged parts will be property of department. Heating coil 3000 watt , 250V
Replacement of following damaged parts with new one of geyser (The damaged parts will be replaced with new one, new parts will be arranged by the contractor at his own cost and taken out damaged parts will be property of department. Thermostat
Replacement of following damaged parts with new one of geyser (The damaged parts will be replaced with new one, new parts will be arranged by the contractor at his own cost and taken out damaged parts will be property of department. Indicator
Replacement of following damaged parts with new one of geyser (The damaged parts will be replaced with new one, new parts will be arranged by the contractor at his own cost and taken out damaged parts will be property of department. Glass Wool
Overhauling of Ceiling Fan.
Overhauling of Cabin Fan.
Rewinding of ceiling fan along with overhauling.(Orient make)
Rewinding of ceiling fan along with overhauling. (Polar, Khaitan, Kedia, Bajaj, Usha make)
Rewinding of cabin fan along with overhauling.
Repairing of bearing housing.
S/F of following ball bearing of approved make 6201
S/F of following ball bearing of approved make 6202
S/F of following ball bearing of approved make 6203
Conversion of bush housing into bearing assembly with machining of shaft of rotor.
Painting of ceiling fan. (Paint and material required for painting work will be arranged by the contractor at his own cost)
Work of numbering(15 mm to 20 mm size) on ceiling fan or cabin fan or exhaust fan.(Paint and material required for numbering will be arranged by the contract at his own cost)
Shifting of ceiling fan or cabin fan.
Shifting of air cooler.
Overhauling of Air Cooler Fan. (Kit Fan). with insulating varnish.
Overhauling of 12”/18” Exhaust Fan with insulating varnish.
Rewinding of Air Cooler Fan (Kit Fan) along with overhauling.
Rewinding of Exhaust fan single phase, 230V, 50Hz along with overhauling of up to 60W rating
Replacement of shaft of Air Cooler Fan. or Exhaust Fan
Repairing of bearing housing of 12”/18” Exhaust Fan.
Replacement of capacitor of Air Cooler Fan(Kit Fan) or Exhaust Fan . (capacitor will be provided by the department free of cost)
Replacement of ply wood sheet of 3 mm thickness (ply wood will be arranged by the contractor at his own cost)
Replacement of electric wire for air cooler as per requirement (Wire will be provided by the department free of cost)
Replacement of wood wool pad with netting of a Air Cooler. (Wood wool pad will be arranged by the contractor as his own cost.)
Removal or Installation of cooler fan or 12”/18” Exhaust Fan.
Replacement of 12”/18” metallic frame of Exhaust fan with spokes.
Replacement of Arm set of kit fan with spokes.
Replacement of 12”/18” Exhaust fan metallic blade.
Replacement of 12”/18” kit fan metallic blade.
Replacement of cabin fan blade.
Filling of water in water tank of air coolers installed in G M Building of PTEP,Panki . (30 No Cooler for 120 days)
Danting & Painting of Air Cooler -Removal of old paint, Preparation of surface , smoothening of surface & then painting of surface with one coat of red oxide & two cot of synthetic enamel paint. The above work carried out in the internal& external surface of the cooler. All required material for painting work shall be arranged by the contractor at his own cost.
Danting & Painting of Air Cooler -Preparation of surface and smoothening of surface of old cooler & then painting of surface with one coat of synthetic enamel paint. The above work carried out in the internal& external surface of the cooler (painting of internal surface of water tank of air cooler with Japanes black paint). All required material for painting work shall be arranged by the contractor at his own cost.
Danting & Painting of Air Cooler -Internal Surface of water storage tank with water resistance paint first quality paint. All required material for painting work shall be arranged by the contractor at his own cost.
Replacement & fixing of water storage tank with good quality/gauge GI sheet. All required material for this work shall be arranged by the contractor at his own cost.
S/F of Desert cooler steel body (GI sheet) Size: 800 X 810 X 1070 mm, without fan motor and pump. (cooler body should be made of good quality22 gauge sheet and height of tank must be 1 feet)
Repairing of water storage tank with M seal
Replacement & Fixing of water circulating pipe with elbo
Replacement of damage copper, flexible card, 3x 2.5 sqmm.
Replacement of damaged gun metal bush of ceiling fan/cabin fan .
Replacement of ceiling fan clamps including gentry nut-bolt with split pin .
Replacement of nut bolt with split pin for ceiling fan.
Replacement of rubber gutka of ceiling fan .
Replacement of rubber gutka of Kit Fan/Exhaust Fan .
Replacement of capacitor (2.5 mfd) of ceiling/cabin fan.
Replacement of capacitor (4.0 mfd) for cooling fan / Exhaust fan motor.
Replacement of damaged gun metal bush of Air Cooler Fan (Kit Fan) with new one.
Replacement of 5 Amp. plug top.
Replacement of Water circulating pump for air cooler.
M/s Ambey Enterprises
M/S KRISHNA ENGG.WORKS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .