| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 LAccepted-AOC 489 55 7TH CROSS 7TH MAIN GOKULA 1 2ND PHASE YESHWANTHPUR BANGALORE 560 022 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560022 | L1 | Accepted-AOC L1 | |
| 2 | L2₹8.0 L+₹33,589 (4.41%)Rejected-Finance 777 CHANDRA MOULESHWARA TEMPEL STREET BANGLORE URBAN KARNATAKA BANGALORE RURAL KARNATAKA 560088 | BENGALURU URBAN | KARNATAKA | 560088 | L2 | Rejected-Finance L2 | |
| 3 | L3₹8.7 L+₹1.1 L (14.1%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical not submitted GST returns for the month of May,2025 after seeking shortfall document |
| Sl No | Description | Qty | Unit | Sri Manjunatha Swamy Electricals L2 | NAGALAKSHMI ELECTRICALS L1 | MOHAN ENGINEERING INSTALLATION AND SERVICES L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing and commissioning of following capacity (continuous loading) BEE 5 Star rated (Corresponding Level as per BIS amended upto date of receipt of tender) , 1/0.433 KV step down, 3 Phase, 50 Hz, Dyn 11 vector group, ONAN (Oil Natural Air Natural) copper wound transformer (Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better, suitable for outdoor/ indoor applications with On Load Tap Changer (OLTC) on HV side having AVR relay and Remote Tap Changer Control (RTCC) for automatic sensing of incoming voltage, automatic operation of OLTC and facility for remote and manual operation of OLTC HV side in range of +5% to -15% in steps of 2.5%, having cable end boxes on HV side suitable for 3x300 sqmm XLPE cable of 11 KV grade, including bus trunking arrangement on LV side including supplying and laying of copper conductor multicore control cable from transformer to HT breaker/panel for safety tripping, complete with all accessories and safety provisions as per relevant IS Code including first filling of filtered dehydrated oil, i/c supplying and grouting of suitable M.S. Channel with all accessories and transformer shall be confirming to IS : 2026 (Part 1 to Part 5), IS : 1180 and duly ISI Marked and as per CPWD specifications complete in all respects etc as required at site.The maximum flux density in any part of the core and yoke at rated voltage and frequency shall be such that the flux density with + 12.5 percent combined voltage and frequency variation from rated voltage and frequency does not exceed 1.9 Tesla. The permissible temperature-rise shall not exceed 35 dg. C for oil and 40 dg. C up to 200 KVA and 40 dg. C for oil and 45 dg. C for above 200 KVA for winding. Inside of tank shall be painted with varnish or liquid resistant paint. For external surfaces one coat of thermos setting powder paint or one coat of epoxy primer followed by two coats of polyurethane base paint shall be used. IS: 1180 (Part 3) shall be referred to for paint thickness for normal to medium corrosive atmosphere. For highly polluted atmosphere and special application external paint work shall be as per direction of Engineer-in-Charge. Design ambient condition: a) air temperature 50 deg C, b) Relative Humidity 90 % Max, c) Seismic Zone as per location of site, d) Altitude as per location/site. Noise level Shall not exceed limits as per NEMA TR-1 with all accessories running measured as per IEC 551 / NEMA standard. The transformer should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc. Marking Each transformer shall be provided with rating plate made of anodize aluminium/ stainless steel material securely fixed on the outer body, easily accessible, as per IS: 1180 Part-3. The entries on the rating plate shall be indelibly marked. Fitting and Accessories : The following fittings shall be provided:- a) Two earthing terminals with the earthing symbol b) Oil level gauge indicating oil level at minimum, 30°C and maximum operating temperature; c) Air release device (for non-sealed type transformers) d) Rating and terminal marking plates; e) Silica gel breather f) Drain-cumsampling valve (¾″ nominal size thread, IS 554) preferably steel with plug for three phase transformers; g) Thermometer pocket with cap; h) Oil filling holes having (1¼″ nominal size thread) with cover (for sealed type transformers without conservator); i) Lifting lugs for the complete transformer as well as for core and winding assembly; j) Pressure relief device or explosion vent above 200 kVA; k) One filter valve on the upper side of the tank (for transformers above 200 kVA); l) Unidirectional flat rollers (for transformers above 200 kVA); m) Inspection hole (for transformers above 200 kVA); n) HV side neutral grounding strip (where one of the HV bushing terminal is connected to earth); o) Buchholz relay for transformers above 800 kVA. p) Arcing horns or suitable rating lightning arrestors for HT side – 3 Nos. q) Bird guard; r) Oil temperature indicator and winding temperature indicators for transformers above 200 kVA with suitable tripping mechanism above permissible limit s) Jacking pads (for transformer above 1600 kVA); t) Additional Neutral separately brought out on bushing for earthing. u) Magnetic oil level gauge (for transformer above 1600 kVA) with low oil level alarm contact; v) Non return valve (for conducting pressure test); w) Pressure relief device or explosion vent x). Monogram Plate y) Inspection cover z). Detachable type radiators with top and bottom shutoff valve. a) Oil Conservator with Oil level indicator, minimum level marking and drain plug for all transformers of capacity 50 KVA and above. b) Necessary hardware, clamps, lugs etc. for termination on HV/MV etc. for all transformer | 1 | Each | 3,65,000 ₹4,30,700 | 4,29,181 ₹4,29,181 Lowest | 5,20,000 ₹6,13,600 |
| 2.00 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. | 2 | set | 48,000 ₹56,640 | 21,464 ₹21,464 Lowest | 40,000 ₹47,200 |
| 3.00 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. | 30 | Meter | 6,750 ₹7,965 | 5,400 ₹5,400 | 4,500 ₹5,310 Lowest |
| 4.00 | 9 Meter Pole DP Structure with 200 Amps GOS HT Fuse unit, LA and other accessories as per site condition | 1 | Set | 58,000 ₹68,440 | 1,00,000 ₹1,00,000 | 50,000 ₹59,000 Lowest |
| 5.00 | SITC Outdoor pot head and its accessories. | 2 | Each | 37,000 ₹43,660 | 8,600 ₹8,600 Lowest | 12,000 ₹14,160 |
| 6.00 | SITC of HT 95 sq mm 3 core Cable with termination. | 12 | Meter | 11,760 ₹13,876.8 | 11,400 ₹11,400 Lowest | 14,400 ₹16,992 |
| 7.00 | SITC of LT 95 sq mm 3.5 core Al Armored Cable with termination. | 32 | Meter | 28,000 ₹33,040 | 16,000 ₹16,000 Lowest | 48,000 ₹56,640 |
| 8.00 | SITC 630 A 4 P Online change over switch with outdoor Box and stand including end termination as per site requirement. | 1 | Set | 75,000 ₹88,500 | 40,000 ₹40,000 | 18,000 ₹21,240 Lowest |
| 9.00 | Connecting the output cable from changeover switch to existing Feeder Pillar with necessary earth work, end termination etc as per site condition. | 1 | L/s | 45,000 ₹53,100 | 14,000 ₹14,000 Lowest | 30,000 ₹35,400 |
Tender Value
Refer Docs
EMD Value
₹19,000
Closing Date
6 Oct 2025, 3:00 pmClosed
The Director
ICAR-IIHR, Hesaraghatta, Bangalore
Step Down Transformers and 11 KV Overhead line work at ICAR-IIHR, Hesaraghatta, Bangalore
2025_DARE_877502_1
5-56/2025-26/SP-IIHR/2641071
Open Tender
Electrical Works
Works
60 days
ICAR-IIHR, Hesaraghatta, Bangalore
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹19,000
13 Apr 2026
15 Sept 2025
8 Oct 2025
15 Sept 2025
6 Oct 2025
15 Sept 2025
stage.html
html • 0.05 MB
technical_922387.pdf
techsummary_922387.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.92 MB
BOQ_922387.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .