Office of Military Engineer Services ,Garrison Engineer (AF) Thane, Kolshet Road, Sandoz Baugh Post, Thane 400607
SR/REPLACEMENT OF CI AND GI PIPE LINE, GEYSER, EXHAUST FAN , CEILING FAN AGAINST BER ITEMS AND ALL CONNECTED WORK OF PUMP HOUSE NO 2, PROVN OF AC POINTS WITH WIRING AT J,K,L AND 02 BLOCKS OF MES AND certain MINOR WORK AT SITE P UNDER GE AF THANE
2023_MES_628390_1
8316/E8
Open Tender
Miscellaneous Works
Item Rate
120 days
THANE
AS PER NIT
8 documents required · 8 mandatory
₹500
GE AF THANE
₹62,000
Yes
13 Apr 2024
15 Nov 2023
12 Dec 2023
15 Nov 2023
11 Dec 2023
29 Nov 2023
15 Nov 2023 - 29 Nov 2023
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m in depth for taking out/laying pipe line and getting out, in soft/loose Soil complete all as specified and directed by Engineer-in-charge.
Returning, filling including spreading leveling, watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and directed by Engineer-in-charge.
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-charge.
Taking down GI water tubing with 100 mm bore all fittings and fixtures complete from wall/floor / trenches all as dircted by Engineer in charge.
All as per Srl item No 4.00 here-in-before but GI pipe of size 80 mm complete aii as specified and directed by Engineer-in-Charge.
All as per Srl item No 4.00 here-in-before but GI of size 50 mm complete aii as specified and directed by Engineer-in-Charge.
All as per Srl item No 4.00 here-in-before but GI of size 40 mm complete aii as specified and directed by Engineer-in-Charge.
All as per Srl item No 4.00 here-in-before but GI of size 25 mm complete aii as specified and directed by Engineer-in-Charge.
All as per Srl item No 4.00 here-in-before but GI of size 20 mm complete aii as specified and directed by Engineer-in-Charge.
Supplying & Laying, connecting and testing GI pipe 100 mm bore medium grade including necessary fittings in trenches complete all as specified and directed by Engineer-in-charge.
All as per Srl item No 10.00 here-in-before but of size 80 mm bore complete all as specified and directed by Engineer-in-charge.
All as per Srl item No 10.00 here-in-before but of size 50 mm bore complete all as specified and directed by Engineer-in-charge.
All as per Srl item No 10.00 here-in-before but of size 40 mm bore complete all as specified and directed by Engineer-in-charge.
All as per Srl item No 10.00 here-in-before but of size 25 mm bore complete all as specified and directed by Engineer-in-charge.
All as per Srl item No 10.00 here-in-before but of size 20 mm bore complete all as specified and directed by Engineer-in-charge.
Refixing old serviceable steel GI tubing of size 50mm and connecting incuding fittings /fixtures on wall /floor or in trenches including cleaning all as directed
All As per Srl Item No -16.00 here-in-before but for 40mm size
All As per Srl Item No -16.00 here-in-before but for 25mm size
All As per Srl Item No -16.00 here-in-before but for 20mm size
Disconnecting ,dismantling and taking down of unserviceable rusted water tubing CI of size 150 mm from existing place in trenches/wall/floors/ceilings complete all as specified and directed by Engineer-in-Charge:
Supply, laying, and fixing of Ductile Iron Pressure Pipes, Centrifugally Cast [Spun], Class "K-9" of size 100mm with Socket and Spigot ends conforming to IS - 8329 in standard lengths suitable for Push-On Rubber Gasket Jointing with inside Cement Mortar Lining and Black Bitumen external coating complete laid in trenches / along the walls / ceilings / floors / ducts / on pillar post all as specified and directed by Engineer-in-charge.
Supply, laying, and fixing of Ductile Iron Pressure Pipes, Centrifugally Cast [Spun], Class "K-9" of size 80mm with Socket and Spigot ends conforming to IS - 8329 in standard lengths suitable for Push-On Rubber Gasket Jointing with inside Cement Mortar Lining and Black Bitumen external coating complete laid in trenches / along the walls / ceilings / floors / ducts / on pillar post all as specified and directed by Engineer-in-charge.
Dismantling and taking out unserviceable Sluice Valve of size 80 mm bore from line complete all as directed by Engineer-in-charge.
Dismantling and taking out unserviceable Sluice Valve of size 100 mm bore from line complete all as directed by Engineer-in-charge.
Dismantling and taking out unserviceable Sluice Valve of size 150 mm bore from line complete all as directed by Engineer-in-charge.
Supply and fix Sluice Valve Class PN 1.6 80 mm dia with iron wheel head, gaskets nuts, bolts,washers complete all as directed by Engineer-in-Charge.
Supply and fix Sluice Valve Class PN 1.6 100 mm dia with iron wheel head, gaskets nuts, bolts,washers complete all as directed by Engineer-in-Charge.
Supply and fix Sluice Valve Class PN 1.6 150 mm dia with iron wheel head, gaskets nuts, bolts,washers complete all as directed by Engineer-in-Charge.
S&F CI Butterfly valve of size 150 mm dia including with packing materials, nuts, bolts, etc , complete all as specified and directed by Engr-in-charge.
S&F CI Butterfly valve of size 100 mm dia including with packing materials, nuts, bolts, etc , complete all as specified and directed by Engr-in-charge.
S&F CI Butterfly valve of size 80 mm dia including with packing materials, nuts, bolts, etc , complete all as specified and directed by Engr-in-charge.
M&L for CI/DI Special like bends, Tees, collar, Tail piece etc (any type & shape and angle) tapers of any type (straight, bend, increasing, decreasing or double socket etc) Tee pieces single branch, 'Y' junction double branch, cross (all sockets or socket and spigot) collars, caps and plugs suitable for CI/DI pipe upto 150 mm dia , complete all as specified and directed by Engr-in-charge.
S&F DI pipe rubber gasket suitable for 100mm K-7/K-9 pipe ,complete all as specified and directed by Engr-in-charge.
S&F DI pipe rubber gasket suitable for 80mm K-7/K-9 pipe ,complete all as specified and directed by Engr-in-charge.
Supply and fixing in Repairs of 50 mm bore gun - metal glove or gate Valves,With iron Wheel head,Screwed both ends for iron pipe and fixed for GI pipe including dismantling and taking out unserviceable valve complete all as specified and directed by Engineer -in- Charge.
All as per Srl item No 35.00 here in before ,but of size 40 mm dia
All as per Srl item No 35.00 here in before ,but of size 25 mm dia
All as per Srl item No 35.00 here in before ,but of size 20 mm dia
M&L for GI bends, Tees, Nipple, Tail piece etc (any type & shape and angle) tapers of any type (straight, bend, increasing, decreasing or double socket etc) Tee pieces , all sockets or socket and plugs suitable for GI pipe 50 mm dia , complete all as specified and directed by Engr-in-charge.
Taking down carefully existing aluminium/Copper point wiring light, fan socket or power bell complete with fitting such as sockets, ceiling roses, pendants batten holders regulators socket, call bells & making good to the disturbed surfaces of walls, matching the colour with existing Surface all as spd and directed by Engr-in-Charge. Note: Rate for making good shall be deemed to be included in quoted rate.
M& L for Point wiring complete with 1100 volts grade FRLS insulated unsheathed cable of copper conductor cable multi stranded of size 1.5 Sqmm single core including PVC rigid concealed conduit medium grade of suitable size (not less than 20mm dia) with all accessories such as bend reducers /MS hooks, MS junction box 1.2mm thick MS pressed sunken terminal boxes of suitable sizes for mounting of switches sockets, fan regulators etc covered with 3.15 mm thick bakelite laminated (Hylem/Anchor) top cover including continuous earth wire of size 1.5 Sqmm PVC strandedcopper conductor unsheathed, insulated stranded (Green colour) connected to common earth point dolly ,complete all as specified and as directed by Engr-in-charge .for the following:-
One Ceiling / Exhaust fan point to be controlled by one number one way PT switch
All as per Srl item No 41.00 here in before but with 4 Sqmm wire for 15 Amp socket outlet on independent board
S&F switch Piano type single pole one way 5 Amp,230 V AC ,complete all as specified and as directed by Engr-in-charge.
S&F switch Piano type single pole one way 16 Amp on laminated sheet top cover ,complete all as specified and as directed by Engr-in-charge (Sheet top cover incl in point wiring) .
S&F socket Pinao type 6 Pin 16 amp,230 V AC ,complete all as specified and as directed by Engr-in-charge.
S&F Ceiling rose, two to three terminals with bakalite 20mm back plate,complete all as specified and as directed by Engr-in-charge.
Supply & fixing ceilling fan of size 1200 mm sweep 5 star rating complete all as specified and as directed by Engr-in-charge.
Supply & fixing fresh air fan PVC body of size 300 mm sweep ,complete all as specified and as directed by Engr-in-charge.
Supply & fixing fresh air fan PVC body of size 450 mm sweep ,complete all as specified and as directed by Engr-in-charge.
Supply and fix electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate,NRV, connection piece etc.complete all as specified and as directed by Engr-in-charge.
Material and labour for sub main wiring complete with 2 run of 4 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through and including PVC casing and caping of size 25mm width or above as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 4 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly including removing old unserviceable itemcomplete and making good the disturbed surfaces to match with existing all as specified and directed. Note : - 02 run of 4 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable and 01 run of PVC casing and caping shall be measured as one unit.
Supply and fix MCB SP 6 to 32 Amps,10 KA, "C" series, 240 volts complete all as specified and directed.
Supply and fix of sheet metal enclosures with two pin and earth plug and socket complete with single pole MCB 20 Amps complete all as specified and directed.
Supply and fix factory made, sheet metal enclosure, double door, 415 volts, AC,TPN, vertical distribution board, 4 way, painted with epoxy based powder coated suitable for mounting MCCB as incomer of rating upto 160Amps, FP, 16-36 KA and MCB SP /TP as outgoings and complete with and including 200 amps rated copper busbar, neutral bar,earth bar, connecting cable links with and including top and bottom removable gland plate, complete with IP 43 protection, and making good the disturbed surfaces to match with existing all as specified and directed.
Supply & fix MCCB FP 63 Amps,16 KA, 240 volts complete all as specified and as directed.
Supply,lay and testing of over head line or cable XLPE insulated,galvanised steel strip armoured,1100 volts grade with multistranded aluminium conductor of cross-sectional area 95 sqmm; 3.5 core laid in trenches/pipes/ducts/walls and connection with necessary cable lugs and glands, nuts, bolts and washers etc and testing including removing old unserviceable item complete all as specified and directed. Note: (i) Excavation & Earth work,sand cushioning, cable cover and protection pipe shall be measured and paid separately under relevent item of Sch A. (ii) The cable shall be in one length unless otherwise directed by the GE.
All as per Srl item No.57.00 above but of size 70 sqmm, 3.5 core
All as per item No. 57.00 above but of size 50 sqmm, 3.5 core
All as per item No.57.00 above but of size 35 sqmm, 3.5 core
Supply ,filling and speading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete all as specified in SSR Part-I and as directed. Note: Punned thickess i.e 18 cm shall be measured for paymeny purpose.
Supply and laying unreinforced precast factory made concrete cable cover, class LV, Type -I, flat, size 250mm x 150mm x 40mm, complete all as specified and directed.
M & L for cable route indicator LT Type made of metal cast iron, the strip size not less than 32x4 mm,height 300 mm and round shape of dia not less than 8 cm with embossed LT welded or reveted strip and round plate each other including adequate qty of PCC 1:3:6 type C1 using 20 mm graded stone agregate complete all as specified and as directed.
Supply , installation, testing and commissioning of totally enclosed LT electric panel outdoor type (IP-55) fabicrated out of 3.15mm thick CRCA, CPRI approved sheet dust and vermin proof powder coated double door type independent cabin including locking arrangement for each ACB/MCCBs, bus bar chamber enclosed complete suitable for operating on 415 volt 50 Hz AC supply internally wired with copper conductor/strip of adequate size from main incoming MCCB to bus bar and bus bar to outgoing MCCB/MCBs having legs 45cm made out of 65x65x6mm angle iron grouted on brick masonary platfor upto 30 Cm. Brick masonary platform should be 60Cm above the ground level, comprising the following:- (a) MCCB 250 Amps,FP, 36 KA,415 volts,50Hz-02 No (b) MCCB 125 Amps,FP,16 KA,415 volts,50Hz-2Nos (c) MCCB FP 40 to 100 AMPs-4 Nos (d) Digital voltmeter,with VSS -01 set,Digital, Ammeter,with CTs & ASS-01 set (e) LED phase indication lamps RYB-01 set (f) Aluminium bus bar TPN 400 Amps rating -01 set
M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and as directed.
M&L for Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2010 including testing on completion, complete all as specified.
Supply and fixing of flameproof cum waterproof LED bulk head light fitting of 40 Watt , IP66 protection of cast aluminium alloy material and heat and impact resistance toughen A clear glass having anti corrosive epoxy powder coated finish complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size ,complete all as specified.
Supply and fix Flame proof exhaust fan 350mm sweep IP-66 confirming to IS-IEC60529-1-2001 stainless steel body complete all as specified and directed.
M&L for Flame proof point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed FRLS cable 1100 volts grade, multi stranded with copper conductor drawn through and incl ERW steel conduit with conduit accessories fixed on wall/roof/floors etc and MS terminal boxes concealed in walls covered with plastic laminated top cover 3.0 mm fixed with cadmium plated iron screws etc incl 1.5 sqmm PVC insulated, unsheathed FRLS copper conductor multi stranded cable 1100v grade as earth continuity conductor & connecting to common earth dolly all as specified for one light/fan point controlled by one switch
S & F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V ,complete all as specified and as directed by Engr-in-charge.
NANGIA AND CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .