Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹48.5 LAccepted-AOC | L-1 | Accepted-AOC Eligible L1 Bidder. | |
| 2 | L-2₹49.4 L+₹90,303 (1.86%)Rejected-Finance OPP DAGA HOSPITAL GANDHIBAGH NAGPUR 440002 INDIA | NAGPUR | MAHARASHTRA | 440002 | L-2 | Rejected-Finance Not a Lowest Bidder. | |
| 3 | L-3₹59.5 L+₹11.0 L (22.6%)Rejected-Finance B 814 8TH FLOOR B G TOWER OPP DELHI GATE SHAHIBAUG ROAD AHMEDABAD 380004 | AHMADABAD | GUJARAT | 380004 | L-3 | Rejected-Finance Not a Lowest Bidder. | |
| 4 | Rejected-Technical 63 SECTOR 4 R FARIDABAD HARYANA 121004 | FARIDABAD | FARIDABAD | HARYANA | 121004 | - | Rejected-Technical Not Eligible as firm does not meet NIT criteria Clause - B (xii). | |
| 5 | Rejected-Technical 9 AMARNATH INDUSTRIAL PAR K OPP MAIZE PRODUCT ODHAV SINGARVA ROAD ODHAV AHMEDABAD GUJARAT 382415 | AHMADABAD | GUJARAT | 382415 | - | Rejected-Technical Not eligible for opening of Financial Bid.as firm does not meet experience criteria as mentioned in NIT point C (1) |
Tender Value
₹74.3 L
EMD Value
₹1.5 L
Closing Date
23 Dec 2020, 6:00 pmClosed
AGM (Engg.-E)-I, AAI, DABH Airport, Indore.
O/o Airport Director, AAI, DABH Airport, Indore.
Development of 15 Nos Parking Bays, Parallel Taxi Track and other associated works at DABH Airport, Indore SH - SITC of High Mast Flood Lights
2020_AAI_64329_1
AAI/ID/ENGG(E)/ENIT-11/20-21
Open Tender
Electrical Works
Works
120 days
Indore Airport.
Please refer Tender documents.
15 documents required · 15 mandatory
₹1,180
₹1.5 L
23 Jun 2022
12 Dec 2020
24 Dec 2020
12 Dec 2020
23 Dec 2020
12 Dec 2020
12 Dec 2020 - 17 Dec 2020
Amount
Supply of following sizes of PVC/ XLPE insulated and PVC sheathed aluminium conductor armoured cable of 1.1 KV grade conforming to IS 7098 Part - I as per attached technical specifications. (Make - As per attached list of approved makes.)
A) 3.5C X 70 Sqmm
B) 4C X 50 Sqmm
C) 4C X 25 Sqmm
Supply of following PVC sheathed, XLPE insulated, armoured, copper conductor control cable confirming to IS 7098 (part-1) with upto date amendments etc as required.
A) 6 core X 1.5 sqmm
B) 16 core X 1.5 sqmm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
A) Upto 35 sq. mm Metre
B) Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required.
A) Upto 35 sq. mm
B) Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
A) Upto 35 sq. mm Metre
B) Above 35 sq. mm and upto 95 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
A) 3½ X 70 sq. mm (38mm)
B) 4 X 50 sq. mm (35mm)
C) 4 X 25 sq. mm (28mm)
D) 4 X 16 sq. mm (28mm)
Excavation of the cable trenches in hard rock not exceeding 1.5 meter in width, and lift upto 1.5 meter, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 meter.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
SUB HEAD:(I) SITC of High Mast Flood Lights Design, supply, erection and commissioing of flood lighting system of 28 m height suitable for wind velocity of 39 Mtrs/sec with hot dip galvanized multiple telescopic sections and material of construction of S 355 grade as per BS-EN10 025 (with base plate welded to the bottom sections), holdings and it shall also include head frame, steel wire rope , non corrosive pulley, complete with control gear boxes, electric driven integral power tool, power & control cables etc. as required along with the following etc. complete as required as per the specifications given include making of necessary foundation as per site conditions. a) Luminaires carriage to hold all required LED light fittings for 20 lux average in apron area plus two additional light fittings for redundancy including all accessories, counter weights and self balance etc. b) Raising and lowering mechanism consisting of suitable double drum winch assembly, head frame assembly on top with self fabricating bearing and stainless steel shaft non-corrosive, pulley, & stainless steel wire ropes of minimum 6mm dia 316 Grade S.S hoisting (7/19 construction) etc. complete with internally mounted electric driven 3 phase, 415 volts, 50 Hz operated integral power tool installed inside the base compartment for its operation and also for manual operation. c) Supply, Laying and fixing of 2 runs of flexible round sheath 5 core control cables of appropriate rating from junction box to lantern carriage including wiring with suitable size of copper cable for individual wiring of all fittings including 2 Nos Aviation obstruction lights. d) Supply of foundation bolts manufactured from special steel along with nuts, washer, suitable size anchor plate and template. e) Design, casting of open raft type RCC foundation suitable for soil bearing capacity at site. The minimum M20 grade concrete for the high mast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 meter depth job including all materials and labour and as per site conditions. (The foundation design should be vetted form reputed IIT/ NIT/ any reputed Govt technical institution for withstanding the 140km/hr wind pressure along with desired fittings for 20 average lux level at apron). f) Heavy gauge hot dip galvanized lightening arrester and its necessary connections at the top. g) Wiring of luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 1.5 sq. mm, lugs, MCB etc as required. h) Supply & installation of outdoor stand mounted feeder pillar with 63A TPN MCB incomer, single dial time switch, 45A TP contactor for the automatic switching of luminaries, power tool control with 2 no 9A contactors and raise lower push button, Incoming 25/35 sq. mm and out going 16 & 2.5 sq. mm terminals. i) Provision of 02 Nos GI pipe earthing for High mast with 2.5 M long 40 mm dia GI Pipe including connection to High mast earth terminal with 25 x 3 mm GI flats with all materials and labour. j) SITC of 02 Nos LED Aviation obstruction lights.
Design, supply, erection and commissioing of flood lighting system of 18 m height suitable for wind velocity of 39 Mtrs/sec with hot dip galvanized multiple telescopic sections and material of construction of S 355 grade as per BS-EN10 025 (with base plate welded to the bottom sections), holdings and it shall also include head frame, steel wire rope , non corrosive pulley, complete with control gear boxes, electric driven integral power tool, power & control cables etc. as required along with the following etc. complete as required as per the specifications given include making of necessary foundation as per site conditions. a) Luminaires carriage to hold all required LED light fittings for 20 lux average in apron area plus two additional light fittings for redundancy including all accessories, counter weights and self balance etc. b) Raising and lowering mechanism consisting of suitable double drum winch assembly, head frame assembly on top with self fabricating bearing and stainless steel shaft non-corrosive, pulley, & stainless steel wire ropes of minimum 6mm dia 316 Grade S.S hoisting (7/19 construction) etc. completes with internally mounted electric driven 3 phase, 415 volts, 50 Hz operated integral power tool installed inside the base compartment for its operation and also for manual operation. c) Supply, Laying and fixing of 2 runs of flexible round sheath 5 core control cables of appropriate rating from junction box to lantern carriage including wiring with suitable size of copper cable for individual wiring of all fittings including 2 Nos Aviation obstruction lights. d) Supply of foundation bolts manufactured from special steel along with nuts, washer, suitable size anchor plate and template. e) Design, casting of open raft type RCC foundation suitable for soil bearing capacity at site. The minimum M20 grade concrete for the high mast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 meter depth job including all materials and labour and as per site conditions. (The foundation design should be vetted form reputed IIT/ NIT/ any reputed Govt technical institution for withstanding the 140km/hr wind pressure along with desired fittings for 20 average lux level at apron). f) Heavy gauge hot dip galvanized lightening arrester and its necessary connections at the top. g) Wiring of luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 1.5 sq. mm, lugs, MCB etc as required. h) Supply & installation of outdoor stand mounted feeder pillar with 63A TPN MCB incomer, single dial time switch, 45A TP contactor for the automatic switching of luminaries, power tool control with 2 no 9A contactors and raise lower push button, Incoming 25/35 sq. mm and out going 16 & 2.5 sq. mm terminals. i) Provision of 02 Nos GI pipe earthing for High mast with 2.5 M long 40 mm dia GI Pipe including connection to High mast earth terminal with 25 x 3 mm GI flats with all materials and labour. j) SITC of 02 Nos LED Aviation obstruction lights.
Design,Supply, Erection and Commissioning of 8 mtrs. high GI OCTAGONAL continuously tapered galvanised street light pole with Suitable Luminaire Carriage for installation of flood/Airfield light luminaire suitable for wind velocity as per IS 875 for Indore Airport (but not less than 39 m/sec.), fabricated out of 3 mm MS plate in single section, suitable for installation on a precast foundation with supply of 4 nos. of foundation bolt & anchor plate, rigid flange plate (250x250x16mm min.) welded with the base of pole for fixing on foundation bolts complete as reqd. for structural stability as specified, weather proof and vandal resistant door flush with the exterior surface containing a terminal plate of 5 mm thick backlite sheet with suitable heavy duty connector for loop in loop out cable terminations suitable for upto two numbers 4 core 25 Sq.mm cables & suitable amp rating DP MCB for each fixture connections, earthing bolts for continuous earth connection complete as required with 01 No wired LED obstruction light as per specifications. NOTE : (The top & bottom dia (A/F) of the pole shall not be less than 70mm & 155mm respectively).
Design,Supply, Erection and Commissioning of 9 mtrs. high GI OCTAGONAL continuously tapered galvanised street light pole with Suitable Luminaire Carriage for installation of flood/Airfield light luminaire suitable for wind velocity as per IS 875 for Indore Airport (but not less than 39 m/sec.), fabricated out of 3 mm MS plate in single section, suitable for installation on a precast foundation with supply of 4 nos. of foundation bolt & anchor plate, rigid flange plate (250x250x16mm min.) welded with the base of pole for fixing on foundation bolts complete as reqd. for structural stability as specified, weather proof and vandal resistant door flush with the exterior surface containing a terminal plate of 5 mm thick backlite sheet with suitable heavy duty connector for loop in loop out cable terminations suitable for upto two numbers 4 core 25 Sq.mm cables & suitable amp rating DP MCB for each fixture connections, earthing bolts for continuous earth connection complete as required with 01 No wired LED obstruction light as per specifications. NOTE : (The top & bottom dia (A/F) of the pole shall not be less than 70mm & 155mm respectively).
Design,Supply, Erection and Commissioning of 7 mtrs. high GI OCTAGONAL continuously tapered galvanised street light pole with Suitable Luminaire Carriage for installation of flood/Airfield light luminaire suitable for wind velocity as per IS 875 for Indore Airport (but not less than 39 m/sec.), fabricated out of 3 mm MS plate in single section, suitable for installation on a precast foundation with supply of 4 nos. of foundation bolt & anchor plate, rigid flange plate (200x200x12mm min.) welded with the base of pole for fixing on foundation bolts complete as reqd. for structural stability as specified, weather proof and vandal resistant door flush with the exterior surface containing a terminal plate of 5 mm thick backlite sheet with suitable heavy duty connector for loop in loop out cable terminations suitable for upto two numbers 4 core 25 Sq.mm cables & suitable amp rating DP MCB for each fixture connections, earthing bolts for continuous earth connection complete as required with 01 No wired LED obstruction light as per specifications. NOTE : (The top & bottom dia (A/F) of the pole shall not be less than 70mm & 130mm respectively).
Design,Supply, Erection and Commissioning of 6 mtrs. high GI OCTAGONAL continuously tapered galvanised street light pole with Suitable Luminaire Carriage for installation of flood/Airfield light luminaire suitable for wind velocity as per IS 875 for Indore Airport (but not less than 39 m/sec.), fabricated out of 3 mm MS plate in single section, suitable for installation on a precast foundation with supply of 4 nos. of foundation bolt & anchor plate, rigid flange plate (200x200x12mm min.) welded with the base of pole for fixing on foundation bolts complete as reqd. for structural stability as specified, weather proof and vandal resistant door flush with the exterior surface containing a terminal plate of 5 mm thick backlite sheet with suitable heavy duty connector for loop in loop out cable terminations suitable for upto two numbers 4 core 25 Sq.mm cables & suitable amp rating DP MCB for each fixture connections, earthing bolts for continuous earth connection complete as required with 01 No wired LED obstruction light as per specifications. NOTE : (The top & bottom dia (A/F) of the pole shall not be less than 70mm & 130mm respectively).
Design,Supply, Erection and Commissioning of 5 mtrs. high GI OCTAGONAL continuously tapered galvanised street light pole with Suitable Luminaire Carriage for installation of flood/Airfield light luminaire suitable for wind velocity as per IS 875 for Indore Airport (but not less than 39 m/sec.), fabricated out of 3 mm MS plate in single section, suitable for installation on a precast foundation with supply of 4 nos. of foundation bolt & anchor plate, rigid flange plate (200x200x12mm min.) welded with the base of pole for fixing on foundation bolts complete as reqd. for structural stability as specified, weather proof and vandal resistant door flush with the exterior surface containing a terminal plate of 5 mm thick backlite sheet with suitable heavy duty connector for loop in loop out cable terminations suitable for upto two numbers 4 core 25 Sq.mm cables & suitable amp rating DP MCB for each fixture connections, earthing bolts for continuous earth connection complete as required with 01 No wired LED obstruction light as per specifications. NOTE : (The top & bottom dia (A/F) of the pole shall not be less than 70mm & 130mm respectively).
Supply of 200 W LED Flood light Luminaries of Epoxy powder coated pressure die-cast aluminium housing (ADC12/LM24) with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant, suitable to operate on 230 V, 50 Hz AC power supply and as per Lighting Design at Apron. (LED fittings should be efficacy≥110 Lumen/w, IP66 rating & as per specifications and 5 year guarantee should be provided for complete fittings i/c controller by manufacturer in favour of AAI.
Supply of 350 W LED Flood light Luminaries of Epoxy powder coated pressure die-cast aluminium housing (ADC12/LM24) with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant, suitable to operate on 230 V, 50 Hz AC power supply and as per Lighting Design at Apron. (LED fittings should be efficacy≥110 Lumen/w, IP66 rating & as per specifications and 5 year guarantee should be provided for complete fittings i/c controller by manufacturer in favour of AAI.
Supply of 500 W LED Flood light Luminaries of Epoxy powder coated pressure die-cast aluminium housing (ADC12/LM24) with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant, suitable to operate on 230 V, 50 Hz AC power supply and as per Lighting Design at Apron. (LED fittings should be efficacy≥110 Lumen/w, IP66 rating & as per specifications and 5 year guarantee should be provided for complete fittings i/c controller by manufacturer in favour of AAI.
Installation, adjusting, testing and commissioning of 200/350/500 W LED Flood light Luminaries as per requirement on high mast carriage & poles in the new apron so as to achieve desired lux level (Average lux level of 20 Lux & not less than 10 lux at extremities) i/c connection, interconnection and allied accessories etc complete as required as per site condition requirement.
Design, supply, installation, Testing and Commissioning of 1X20 KVA Capacity, 3 phase in / 1 Phase out online UPS in Stand alone configuration with double conversion PWM IGBT technology to drive constant current regulators as per technical specifications/data sheet enclosed. The UPS shall have built in automatic static by pass, phase sequence protection, pure sine wave output. input-output isolation, built in isolation transformer compatibility with generator supply cold start capability, EMI/RFI noise filter advanced communication-RS232 or equivalent port and user friendly LCD display, suitable to operate at 415V, 50Hz, 3 Phase AC supply and delivering single phase loads with Single phase output and necessary safety protection. The job also includes SITC of 12V, VRLA SMF batteries to give a backup time of minimum 20 minutes along with MS battery rack, connectors, wiring between battery bank and UPS with insulated copper conductor of required size as per site requirement etc. as required. Input of UPS shall have 63 amp 4 pole MCB, The output of UPS shall have 01 No 100 Amp Manual change over switch. Job also includes Input and output copper flexible cable. UPS & Batteries should be As per AAI Approved makes and Warranty on UPS and Battries should be for 02 Years.
M R ELECTRICALS
jaydeep agency corporation
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .