Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.5 LAccepted-AOC 11 1 7 P D KYDGANJ PRAYAGRAJ U P PIN 211003 | PRAYAGRAJ | UTTAR PRADESH | 211003 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹19.9 L+₹1.7 L (9.31%)Rejected-Finance 018 GROUND FLOOR LEKHRAJ ENCLAVE LEKHRAJ PANNA SECTOR 2 VIKAS NAGAR LUCKNOW UTTAR PRADESH 226022 | LUCKNOW | UTTAR PRADESH | 226022 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹23.2 L+₹5.0 L (27.5%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹23.4 L+₹5.2 L (28.8%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹23.5 L+₹5.3 L (29.1%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
26 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST PRAYAGRAJ
GE WEST PRAYAGRAJ PIN-211001
REPAIR AND MAINTENANCE TO DRAIN, SEWAGE LINE AND OTHER MISC WORK UNDER AGE B/R-II AT NEW CANTT PRAYAGRAJ
2023_MES_600857_1
8624/E8
Open Tender
Civil Works
Item Rate
270 days
GE WEST PRAYAGRAJ
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE WEST PRAYAGRAJ
₹80,000
Yes
26 Jul 2023
3 Jun 2023
27 Jun 2023
3 Jun 2023
26 Jun 2023
14 Jun 2023
Amount
Cleaning of choked sewer lines of 100mm dia of any depth manually or through mechanical appliances and making sewer line functional , complete including working under , foul condition and depositing the sludge, rubbish etc off the premises at an isolated place to a distance exc. 1.5 Km but not exc 2 KM distance complete all as specified and directed.
Cleaning of choked sewer lines of 150mm dia of any depth manually or through mechanical appliances and making sewer line functional , complete including working under , foul condition and depositing the sludge, rubbish etc off the premises at an isolated place to a distance exc. 1.5 Km but not exc 2 KM distance complete all as specified and directed.
Cleaning of choked sewer lines of 200mm dia of any depth manually or through mechanical appliances and making sewer line functional , complete including working under , foul condition and depositing the sludge, rubbish etc off the premises at an isolated place to a distance exc. 1.5 Km but not exc 2 KM distance complete all as specified and directed.
Cleaning of choked sewer lines of 300mm dia of any depth manually or through mechanical appliances and making sewer line functional , complete including working under , foul condition and depositing the sludge, rubbish etc off the premises at an isolated place to a distance exc. 1.5 Km but not exc 2 KM distance complete all as specified and directed.
Desludging of existing manholes of depth upto 1.50m filled with sludge by means of manually or through mechanical appliances complete including working under foul condition and depositing and removal of sludge , rubbish etc off the premises at an isolated place to a distance exc. 1.5 Km but not exc 2 KM complete all as specified and directed
Desludging of existing manholes of depth upto 1.50m and not exc. 3.00m filled with sludge by means of manually or through mechanical appliances complete including working under foul condition and depositing and removal of sludge , rubbish etc off the premises at an isolated place to a distance exc. 1.5 Km but not exc 2 KM complete all as specified and directed
Desludging of existing manholes of depth more than 3.00m filled with sludge by means of manually or through mechanical appliances complete including working under foul condition and depositing and removal of sludge , rubbish etc off the premises at an isolated place to a distance exc. 1.5 Km but not exc 2 KM complete all as specified and directed
Cleaning and desludging by pumping out sludge water by septic tank cleaning truck i.e. Honey Sucker (The capacity of the truck is 6,000 litres) from existing chocked /blocked septic tanks including taking out all sediment sand , dirt ash, grease fibre or vegetation , foreign materials etc from any depth and size of septic tanks including removing of sludge to distance exc. 3.00 Km but not exc. 5.00 Km away and buried under ground complete all as specified & directed.
Dewatering of existing soak well of following sizes by means of manually or through mechanical appliances and discharging waste into nearby drain, including taking out, foreign materials etc complete all as specified and directed for the following sizes :-.
Soak well 1.80m dia and 3.00 m deep
Soak well 1.20m dia and 3.00 m deep
Soak well 2.40 m dia and 3.00 m deep
Soak well 3.00 m dia and 3.00 m deep
Cleaning of choked WC in ground floor manually or mechanical upto first man holes and making functional including working under foul condition complete all as specified and directed. (Note : - The rates quoted are deemed to be included opening of access door and closing etc as required at site)
All as per srl item No 14 here-in-before but of WC in other than ground floors.
Cleaning of floor trap / Nahani trap / gully trap upto first manhole complete Note : The rates quoted are deemed to be included of access door and closing all as specified and directed .
Excavation in trenches n.exc 1.50 mtr wide and n. exc 1.50 mtr depth for foundation etc or for shafts , wells, cesspits , manholes , pier holes etc n.exc 10 Sqm on plan & n. exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches not exc. 1.50 mtr wide for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc not exc. 10 Sqm on plan exc. 1.5m and not exc. 3.00m in depth and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches not exc. 1.50 mtr wide for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc not exc. 10 Sqm on plan exc. 3.00m and not exc. 4.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Removing excavated soil material n.exc 50m and deposited where directed at a level n exc. 1.5m above the starting point all as specified and directed
Returning filling in including spreading, levelling, watering and well ramming of soil in layers not exceeding 25 cm complete all as specified and directed.
M&L for Reinforced Concrete pipes, class NP3 200 mm bore, laid and jointed with collars complete all as specified & directed.
M&L for 100 mm dia bore salt glazed stone ware drain pipe grade 'A' conforming to IS 651-1972 laid in trenches and jointed in CM 1:1 complete all as specified and directed.
M&L for 150 mm dia bore salt glazed stone ware drain pipe grade 'A' conforming to IS 651-1972 laid in trenches and jointed in CM 1:1 complete all as specified and directed
M&L for cement concrete bed to drain pipe 100 mm dia including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D2 using 40mm graded stone aggregate complete all as specified and directed.
M&L for cement concrete bed to drain pipe 150 mm dia including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D2 using 40mm graded stone aggregate complete all as specified and directed.
M&L for cement concrete bed to drain pipe 200 mm dia including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D2 using 40mm graded stone aggregate complete all as specified and directed.
Cutting into existing man holes for connecting new drains and making good to pipes and rendering cutting out existing benching for and forming branch channel ( 1/2 round or 3'4 section) in cement concrete 1:2:4 type B-1 ( using 20mm graded stone aggregate ) surface smooth finished and reforming benching as required for internal dia of pipe 100mm al as specified and directed.
Cutting into existing man holes for connecting new drains and making good to pipes and rendering cutting out existing benching for and forming branch channel ( 1/2 round or 3'4 section) in cement concrete 1:2:4 type B-1 ( using 20mm graded stone aggregate ) surface smooth finished and reforming benching as required for internal dia of pipe 150mm al as specified and directed.
Cutting into existing man holes for connecting new drains and making good to pipes and rendering cutting out existing benching for and forming branch channel ( 1/2 round or 3'4 section) in cement concrete 1:2:4 type B-1 ( using 20mm graded stone aggregate ) surface smooth finished and reforming benching as required for internal dia of pipe 200 mm al as specified and directed.
Demolition of cement concrete reinforced of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in manhole covers including necessary form work set in CM 1:4 complete all as specified and directed.
M&L for providing RCC 1:2:4 type B-1 using 20mm graded stone aggregate as in slab supported on walls , beams & columns etc as in roof & the like complete all as specified and directed.
Formwork to sides and soffits of slabs n. exc. 200 mm thick and similar works rough finished surfaces of concrete complete.
S&F mild steel TMT bars 8 mm dia and over , cut to length, bent to shape required, including cranking bending spirally for hooping for column,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified.
M&L for cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed .
M&L for PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) in surface channels and drain complete all as specified and directed at site.
M&L Providing cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate in copings, bed plates including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed at site.
M&L for 100mm thick cement concrete type B-2 1:2:4 (using 40mm graded stone aggregate)finishing surfaces even and smooth without using extra cement Spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green complete all as specified.
M &L for PCC 1:5:10 type E-2 using 40mm graded stone aggregate in foundation ,filling and mass concrete complete all as specified & directed.
M&L for 75mm thick PCC 1:3:6 type C 2 (using 40mm graded stone aggregate) laid in panel and joint fell with asphaltic bitumen and sand complete all as specified.
M&L for rubber moulded chequered cement concrete coloured tile 30cm X 30cm X 25 mm thick with grey cement and pigment set jointed and pointed in neat cement slurry over screed bed or bedding layer 15 mm thick in CM (1:6) in floor all as specified including dismantling of tiles complete all as specified and directed.
Extra for farming fair finished drain or channel 30 cm inner girth in cement, concrete, using extra cement, including forms, moulds, mitered/stopped end etc
Taking down PVC pipe of any size or pattern including all fitting head, shoe, band, swan neck, etc complete all as specified and directed.
S & F 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with GI flat iron complete all as specified and directed.
S & F 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S & F 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with GI flat iron complete all as specified and directed.
S & F 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S & F 110 mm dia PVC(SWR) bends any radius without access door complete all as specified and directed.
S & F 75 mm dia PVC(SWR) bends any radius without access door complete all as specified and directed.
S&F of PVC (SWR) junction single (T) equal or unequal 110mm dia complete all as specified and directed.
S&F in repair PVC (SWR) floor trap plain with grating including jointing with solvent cement 75/100 mm dia complete all as specified and directed
S&F in repair PVC (SWR) nahani trap plain with grating including jointing with solvent cement 75/100 mm dia complete all as specified and directed
S&F of PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement complete all as specified and directed
Dismantling RCC Post any section, including taking out embedded portion and making good disturbed ground; posts embedded in natural ground complete all as specified .
Excavating in post holes (or similar holes) in soft/loose soil each not exceeding 0.5cum, getting out, returning, ,watering and removing surplus soil to a distance not exceeding 50m and making good surface complete all as specified & directed.
Mild steel work conforming to Fe-290 (Gde E-165) in posts & struts in fencing including cutting top to shape as directed, drilling holes, notching for wire, etc; flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc complete all as specified & directed.
Dismantling fencing wire mess any type any description complete all as specified and directed at site.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire complete.
Supply only chain link mild steel galvanized fencing, any type or size complete.
Demolition of brick work built in cement mortar or cement lime mortar complete all as specified and directed.
M&L for brick work with sub class ‘B’ old size bricks straight or curved on plan exc 6 m mean radius built in cm (1:6) complete all as specified and directed.
All as per srl item No 63 here-in-before but except old size sub class 'B' bricks. (Note:- Old bricks retrieved from demolition shall be re-used)
M&L for 15 mm thick rendering on fair faces of brick work or concrete surface with CM (1:4) finishing fair, even & smooth without using extra cement complete all as specified and directed .
Taking down cement plaster on brick or stone wall etc including racking out joints, hacking for key, scrubbing down with water etc all as specified and directed.
M&L for two coat cement base paint on wall over one coat cement primer including preparing new or old plastered surfaces complete all as specified.
Preparing new or previously untreated steel & iron surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over & including a coat of red oxide primer complete all as specified and directed.
Forming 12mm thick expansion joint filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound grade 'A' Thickness of concrete slab in in 100 mm complete all as specified.
M&L preparing old painted brick or concrete surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint complete all as specified and directed.
M&L for 80 mm thick M-40 grade factory made machine pressed precast cement concrete coloured interlocking paver block any shape and size conforming to IS 15658-2006 with grey cement and pigment as approved laid over & including 25 mm thick sand cushion and joints filled with sand complete all as specified and directed.
S&F in repairs vitreous china water closet squatting pan " Orissa Pattern" of size 580 X 440 mm white with integral foot rest (excluding flushing cistern and flush pipe) including cast iron P or S trap, front or back inlet and making connection to trap & to flushing cistern complete all as specified& directed. Note:- The unit rate is quoted is inclusive of making good the disturbed surfaces.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified & directed.
M&L for glazed ceramic coloured tiles of size 350 mm x 250 mm / 450 mm x 300 mm and thickness not less than 7 mm as in skirting / dado etc set and jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles including 10 mm thick backing coat in cement mortar 1:4 etc complete all as specified & directed. .
M&L for non skid coloured ceramic floor tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc set & jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles including 15 mm thick screed bed in cement mortar 1:6 complete all as specified & directed
S&F in repairs PVC flushing cistern 10 ltr capacity valve less symphonic action type, low level with and including ball valve float and handle, PVC flush pipe 32 mm bore complete set all as specified and directed.
S & F in repairs stop valve cast copper alloy screwed down for high pressure with crutch or butterfly handles screwed both ends for iron pipe and fixed for 15 mm bore pipe complete set all as specified and directed.
M&L in repair 250 MM dia Reinforced concrete pipes, class NP2, laid and jointed with collar complete all as specified & directed.
M&L for running welding at site in repairs exc 6mm but n exc 9mm in length , thickness of Metal to be welded not exceeding 6 mm complete all as specified and directed.
M&L for welding at site in repairs exc 2.5cm but n exc 5cm in length in length ,thickness of Metal to be welded not exceeding 6 mm complete all as specified and directed.
S&F in repair standard stainless steel grating doom round 125mm size with waste hole(minimum weight 40 grms) complete all as specified and directed.
M & L uprooting of plants/ trees growth on wall/ drains/ roof surfaces etc in a skilled and careful manner using appropriate tools and means and without causing any damage to the adjoining part. The exposed surfaces of wall will be coated with a paste made from ammonium sulphate crystals or with tree killer chemical available in the market. In this condition the root system to be left to absorb and die. The rate for making good the existing wall surfaces damaged during the uprooting of the tree is deemed to be included in the rate quoted by the contractor.
Extra for farming fair finished drain or channel 15 cm inner girth in cement, concrete, using extra cement, including forms, moulds, mitered/stopped end etc
SK ENTERPRISES
JMD Enterprises
JAI MAA VINHYAVASANI CONSTRACTION CO
Anupravesh Enterprises
M/s Vaishnavi Constructions
HARSH ASSOCIETES
PITAMBARI TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .