| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹29.9 L+₹3.8 L (14.4%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹30.0 L+₹3.9 L (14.8%)Rejected-Finance 244 SHARDA VIHAR NEAR NEW HIGH COURT GWALIOR 474002 MP | GWALIOR | GWALIOR | MP | 474002 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹35.1 L+₹9.0 L (34.4%)Rejected-Finance 53 SHANTI S SANIK COLONY BAIRAGARH BHOPAL MP 462 030 | BHOPAL | BHOPAL | MADHYA PRADESH | 462030 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹38.4 L+₹12.3 L (47.1%)Rejected-Finance LIG 10 VIVEK NAGAR NAVIBAGH BHOPAL MADHYA PRADESH 462038 | BHOPAL | MADHYA PRADESH | 462038 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
5 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Gwalior
Garrison Engineer Gwalior Morar Cantt
8893/GWL/E8 REPAIR AND MAINT OF CENTRAL AND PACKAGE TYPE AC AT MORAR CANTT UNDER GE GWALIOR
2023_MES_617539_1
8893/GWL/E8
Open Tender
Electrical and Maintenance Works
Works
335 days
Garrison Engineer Gwalior
Please refer tender documents
9 documents required · 9 mandatory
₹500
Garrison Engineer Gwalior
₹80,000
Yes
2 Jan 2024
6 Sept 2023
10 Oct 2023
6 Sept 2023
5 Oct 2023
21 Sept 2023
Amount
M&L for dismantling of cooling tower part by part complete and refixing at same position after replacement/repairing of defective parts such as Mechanical Equipment Support,Cooling Tower Louvers,Water Distribution Piping,honey comb fins and painting is also to be done on the outer and inner surface of the cooling tower with existing colour complete all as specifed and directed.Note : Amt of Honey comb finns, louvers should be paid to contractor separately.
Taking down the existing UNSV filter from AHU upto to 10500 CFM, cleaning the cooling coil with suitable chemical scale 400 and replace the all unsv filter with new AHU filter as per sample complete all as specified and directed.
M&L in replacement of Louvers of ac plant as per sample/size/make complete including taking down all as specified and directed.
M&L in repair for pumping down the existing refrigerant gas in separate cylinder immediately after end of season and fill/re charge the gas at the starting of season carry out pressure leak test by nitrogen gas of the system of AC plant 1 x upto 85 TR for leak proof valve joint, seal other connected controls flaries etc including identify & rectify of leak defects and maintaining constant pressure of 160 lbs on low side and 200 lbs at high side at least 24 hrs complete all as specified and directed. Note : (i) Necessary leak proof empty cylinders and necessay pumps , tools need to be included in the quoted rate. (ii) If any leakage in the cylinder after pumping down, the diffiencies need to be filled by the Contractor without any extra cost.
M&L in repair for descaling of condenser tube of central AC plant of cap 1 x upto 85 TR by disconnecting the condenser from the system cleaning by descaling cloution of make (as per existing) and descaling solution, cleaning solution, cleaning condenser tube by nylon brush & MS rod of suitable size repalcement of rubber joints and unserviceablenut bolts complete all as specified and directed. Note : Necessary tools need to be included in the above quoted rate.
Taking out old perished/worn out mechanical oil seal of compessor of ac plant 85 TR at coupling end and replacing it with the (as per existing make), checking for no leakage of oil/gas, testing and commissioning to the entire satisfaction of Engineer in Charge complete all as specified and directed. Note : Gas & Oil required to be charged after replacement of mechanical oil seal shall measured and paid separately.
Taking out old defective burnout motor of capacity 15 HP, 3 phase, 440 V, 50 Hz from foundation and transfer it to workshop for rewinding with super enameled copper wire of existing size & guage and replacement of DE & NDE bearing so as to match the manufacturer original specification and refitting the same, testing and commissioning complete all as specified and directed.
S&F in replacement of Single Phase Preventor of the LT Panel of AC Plant,32 Amp 415 V, 50 Hz 3 Phase complete including taking down all as specified and directed.
S&F in replacement of MCCB of the LT Panel of AC Plant, 63 Amps, 4 Pole, C-Curve, AC, 415V, 50 Hz, 3Phase, c-curve complete including taking down all as specified and directed.
S&F in replacement of TP the Panel of AC Plant, 80 Amps, 3 Pole, C-Curve, AC, 415V, 50 Hz, 3 Phase, c-curve including taking down complete all as specified and directed.
Supply only 407C/R22 gas for Compressor as required in servicing complete all as specified and directed.
M&L in replacement of V-belt from AHU motor with the make and size as required and as per sample including taking down complete all as specified and directed.
M&L in maint and cleaning of cooling tower of central AC Plant of capacity 1 x 160 TR by applying suitable chemicals(Scale 400) and removing all deposited dust, foreign material, cleaning of filter and servicing of Ct fan motor, sprinklar and PVC arms and also repairing leakage of water in cooling tower complete all as specified and directed.
M&L in replacement of CT fan blade for CT motor of cooling tower of central AC Plant of capacity 1 x 185 TR of make as per site including taking down requirement or as per sample complete all as specified and directed.
M&L replacement of spray nozzle of cooling tower of central AC plant of cap 1 x 225 TR of make as per site requirement or as per sample complete including taking down all as specified and directed.
M&L in replacement of water of water pressure indicating gauge(Caliberated type) fitted water circulation circuit (Range-0 to 100/150 lbs/sq in and 0 to 7/10.6 kg/sq cm complete including taking down all as specified and directed.
Taking out old defective burnout motor of capacity 5 to 10 HP, 3 phase, 440 V, 50 Hz from foundation and transfer it to workshop for rewinding with super enamelled copper wire of existing size & gauge and replacement of DE & NDE bearing so as to match the manufacturers original specification and refitting the same, testing and commissioning complete all as specified and directed.
M&L for filling compressor oil grade CPI 120 for compressor complete all as specified and directed.
S&F in replacement of micro process computerised mother board suitable for Central AC Plant upto 85 TR Panel of (as per existing make) complete including taking down all as specified and as directed.
M&L for complete servicing of Duct AC of any capacity including air filter cleaning,condenser and evaporator coil cleaning,insulation of tubing with expanded polythene foam insulation tubing and making necessary connection including M&L for implastiised PVC pipe medium duly 20mm dia for draining out condensed water all as specified and directed.
S&F PCB Circuit in repair with remote control of Duct AC suitable for any make and capacity of 3 Ton Duct type AC including taking down.
Dismantling and taking out the existing old unserviceable compressor hermetically/rotary sealed unit of any make from Duct AC and S&F New compressor suitable for Duct AC of capacity 3 Ton complete all as specified and directed by Engr-in-charge.
M&L Replacement of Power Contractor 32 Amps of the Duct AC,3 pole ,415 V, 50 HZ,3 phase complete all as specified and directed.
M&L in replacement of filter Strainer for Condenser Pipe line of AC Plant including taking down complete.
S&F water level indicator in repair as per sample complete including taking down all as directed.
M&L in replacement of AHU fine filter of size, down to micron and EU-4, size and CFM shall be as per site requirement complete including taking down all as speficied and directed.
M&L in replacement of AHU HEPA NANO filter of size, down to micron and EU-4, size and CFM shall be as per site requirement complete including taking down all as speficied and directed.
M&L in repair of cladding in external duct and exposed pipe.
M&L in repair of insulation 25 mm thick in duct and and pipe line.
M&L in replacement of AHU coil as persuitable size including taking down complete.
S&F in replacement of 3 way mixing valve of suitable size as per site/sample requirement including taking down.
S&F in replacement of strip type heater of capacity 3 KW including taking down complete all as specified and directed.
M&L in Making of MS leader up to 6 mtrs.
S&F temperature sensor in repair at inlet and outlet on both ends of Chiller including taking down complete all as specified and directed.
M&L in replacement of Air Break(Power) contractor 65 Amps of the panel of AC Plant(As per sample), 3 Pole, AC, 415 V, 50 HZ, 3 Phase, including taking down complete all as specified and directed.
M&L in replacement of relay 32 Amps of the LT panel of AC Plant, 3 pole, AC, 415 V, 50 Hz, 3 Phase, including taking down complete all as specified and directed.
M&L in repair and complete overhauling and through checking of of 5TR capacity package type AC unit including leak tesing and pressure testing for 24 hours and gas changing with R-22 refrigarent including testing with Nitrogen gas etc, complete all as specified and directed by Engr-in-Charge.
S&F condenser pump with motor 10 HP in repair complete fitting and testing including taking down complete.
S&F New compressor in repair including taking down (as per existing Make and capacity)
Supply and fixing of butterfly valve in repair including taking down follow :-
M&L for complete Servicing/overhauling of motor which is attached to the chiller pump/condenser pump for making it smooth operational and as per direction of Engr-in-Charge. Note : Necessary servicing will be carried out from authorised rep of Manufacturers.
M & L for GI pipe Med grade of 25 mm dia alongwith all fittings and fixtures complete laid in trenches all as specified and directed.
S&F cast iron/Brass Gate Valve cofiorming to IS 14846/2000,ISI Mark MS Spindle and iron wheel head with both ends flanged with new rubber gasket,bolts and nuts including dismantling of old u/s Gate valve fixed at any location of size 25 mmm dia all as specified and directed.
Supply, install, testing and commissioning complete Centrifugal Mono block pump set coupled with electrical oprated Motor with single phase 220 volts, 50 Hz required head not less than 10 mtrs,(2 HP),Suc x Del (mm) : 25mm x 25mm including fixed on suitable size MS angle placed on PCC foundation and grouting with suitable size/Nos Nut bolts & all electrical connections, all as required at site complete and directed by engineer in charge. Note:- (i) Quoated rates are includes, PCC foundation work, Nut bolts, MS chanel work, all elctrical connections and suitable size of Copper/aluminium cable (if required on site) not more than 20 RM complete.
S&F fully automatic star dol starter suitable for Up to 10 HP Set Motor 220 volts 50 Hz with Panel Mounting complete with contactor and suitable thermal relay all as specified and directed.
Excavation in trenches n exc. 1.5 m wide and n' exc. 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling of excavated soil, including spreading leveling, watering and well ramming in layers, not exceeding 25cm complete all as specified and directed.
Removing of surplus soil to a distance n exc 50 m and depositing where directed at a level n exc 1.5m above the starting point complete.
S&F Bucket type 25mm PVC Float Valve in repair for water storage tank including taking down.
S&F Stainless steel ball Float valve in repair male Thread automatic tank pool water level valve with specification of gel silica seals-Acid and alkali resistant-Top fill(bottom fill float valve also avaliable)-Works on gravity feed.
S&F in replacement of chiller Switch as per sample for ac plant including taking down.
M&L in replacement of spring type heater(As per sample)of capacity 3 KW including taking down.
M&L for replacement of Cold Room Evaporator coil for walking cooler as per sample/size including taking down all as specified and directed.
M&L in replacement of Condenser coil for walking cooler as per sample/size including taking down all as specified and directed.
M&L in replacement of water flow switch of low/high pressure as per sample complete including taking down all as specified and directed.
M&L in replacement of expension valve as per sample complete including taking down all as specified and directed.
M&L in replacement of solenoid valve as per sample complete including taking down all as specified and directed.
M&L in replacement of Angle valve of size 1/4 & 3/8 for ac plant as per sample complete including taking down all as specified and directed.
M&L in replacement of liquid line valve for ac plant as per sample/size/make complete including taking down all as specified and directed.
M&L in replacement of Drier core filter of ac plant as per sample/size/make complete including taking down all as specified and directed.
M&L in replacement of Saftey valve (Pressure relief valve) as per sample/size/make including taking down complete all as specified and directed.
M&L in replacement of Liquid line side glass as per sample/size/make complete including taking down all as specified and directed.
M&L in replacement of phase preventor of AC Plant panel as per sample/size/make complete including taking down all as specified and directed.
M&L in replacement of rectifier of 24 volt for AC Plant panel as per sample/size/make complete including taking down all as specified and directed.
M&L in replacement of Industrial thermometer to check the temp of chiller water for ac plant as per sample/size/make including taking down complete all as specified and directed.
M&L in replacement of chiller water temperator sensor of ac plant as per sample/size/make including taking down complete all as specified and directed.
MCCB 4 Pole, 415 V, Adjustable type, 630 Amps with breaking capacity 36 KA in repair complete including taking down all as specified and directed.
MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA in repair complete including taking down all as specified and directed.
M&L for replacement of Honey Comb fines of size 24x12x6 inch for cooling tower of ac plant as per sample/size/make including taking down complete all as specified and directed.
M&L in replacement of AHU Stainless Steel Actuator Valves, For Water, Valve Size as per sample including taking down complete all as specified and directed.
M&L in replacement of digital thermostate with temp rang -2°C to 30°C complete wiring which is used to control the 3 way valve system automatically including taking down complete
S&F dehumidifier in renewal is non-cyclic,rotary type and dries the air by process of continues physical adsorption,a simplest and most direct metthod of humdity control.The Desiccant used by manufacturing company are non toxic,non flammable with maximum moisture removal capacity. Area 1 :- OT Room We understand that you require dehumdifier to maintain :-Relative Humidity = 50+5% temperature temp(3 to 4 degree C increases)LXWXH=1980 Cubic feet Door= 1 operationalDoor Size + 28 Sq feet door area Door opening per hour= 3 Number of people inside the rom is = % AHU CFM=2700(100% Fresh Air) Considered fresh air load of 2700 CFM to be precooled at 50 DBT/WBT to offset latent load partially.The capacity of precooling coil shall be 2 TR Air humdifier model FFB-1000 are three phase machine - Duct length should not be increases more than 10 mtr or 12 mtr. Dehumdifier shall not able to increse the humidity level if environment humidity is low below designed humidity levels.There are no fixed openings in or out space. Temperature Control is not in our scope.However after installing dehumidifier in the room there is 4-5 degree of Delta T rise in the room. Infiltration load,fresh air load or duct collector load if any.If there is any external ducting to the controlled space,the same shall be fully caulked and sealed and made fully vapour tight.The supply/reture air of the controlled space will not be mixed with supply/return of any uncontrolled(not dehumdified) space.
S&F 900 Watts (Unbreakable Body Sparkless Technology) 100% Copper Air Blower in repair for removing for dust from filter and other AC plant equipment complete all as specified and directed.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique of size 80mm
Note:- 1.Tenderer are advised to visit the site to access the quantum of work and make of articles before quoting the rates.
Akarsha Enterprises
Uma engineers
M/s Shanti Enterprises
PRAGATI ELECTRICALS AND ELECTRONICS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .