Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹55.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹56.9 L+₹54,634.15 (0.97%)Rejected-Finance RM 01 RIDHISIDHI I SRI GANGANAGAR 335001 RAJ | SRI GANGANAGAR | SRI GANGANAGAR | RAJASTHAN | 335001 | L2 | Rejected-Finance L2 FOR REJECTED | |
| 3 | L3₹58.5 L+₹2.2 L (3.82%)Rejected-Finance | L3 | Rejected-Finance L3 FOR REJECTED | |
| 4 | L4₹59.0 L+₹2.7 L (4.72%)Rejected-Finance PLOT NO 46 WARD NO 08 OPPOSITE RADIO TOWER SAGAR ROAD TILAK NAGAR BIKANER 334003 RAJ | BIKANER | BIKANER | RAJASTHAN | 334003 | L4 | Rejected-Finance L4 FOR REJECTED |
Tender Value
Refer Docs
EMD Value
₹1.1 L
Closing Date
21 Jan 2023, 6:00 pmClosed
CWE SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
SPECIAL REPAIR TO BLDG NO P-58/01 TO 04 (MAJ ACCN) AT BHAGAT ENLAVE AT SRI GANAGANAGAR MILITARY STATION SRIGANGANAGAR
2022_MES_571108_1
CA NO CWE SGNR T-54 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
GE SRI GANGANAGAR
AS PER NIT
9 documents required · 9 mandatory
₹1,000
Yes
GE SRI GANGANAGAR
₹1.1 L
Yes
11 Mar 2023
24 Dec 2022
23 Jan 2023
24 Dec 2022
21 Jan 2023
9 Jan 2023
Amount
Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed by Engineer - in - Charge.
Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15 cm thickness below and above ground level, complete all as specified and directed by Engineer - in - Charge.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches , pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed by Engineer - in - Charge.
M&L for brick work with sub class B bricks straight or curved on plan exceeding 6 mtr mean radius built in CM (1:6) etc complete all as specified and directed by Engineer - in - Charge.
M&L for half brick work with sub class B bricks straight or curved on plan exceeding 6 mtr mean radius built in CM (1:4) etc.complete all as specified and directed by Engineer - in - Charge.
Dismantling of brick tiles or terracing tiles single layer on roof including taking down existing APP membrane & disposal of retrieved material upto a distance n.exc 100m where complete all as specified and directed by Engineer - in - Charge.
Demolition of mud in roof, any thickness including plastering and leaping (where full thickness removed or only a part there of disposal off rubbish upto a distance n.exc 100m, where complete all as specified and directed by Engineer - in - Charge.
M & L for cleaning of old Roof wall/ concrete surfaces & applied a coat of cold bituminous primer over cleaned surface @ 0.40 Kg/Sqm followed by APP modified five layer ploymeric membrane 3mm thick, minimum wt 3.60 kg/Sqm reinforced with polyester non-woven fabric (weighing not less than 150gms/Sqm ) manufactured by M/S STP Ltd/IWL India Ltd or its equivalent, laid as per the manufactures instruction with side over lap of 75mm & end over lap of 100mm & tucked into the chases on vertical surfaces if required complete all as specified and directed by Engineer - in - Charge.
M & L for 40mm thick brick tiles bedded in 15 mm thick cement mortar (1:6) and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete all as specified and directed by Engineer - in - Charge.
All as per itme no. 09 above except brick tiles. Note:- brick tiles retrieved from item no 06 shall be used.
M&L for cement concerete type C2, (1:3:6) using 20 mm graded aggrigate as in filling and mass concerete as in roof padding etc complete all as specified and dirceted by Engineer-In-Charge.
M&L for PCC (1:2:4), type B1 using 20 mm graded stone aggregate as in roof kerbs / benching / coved fillets etc rounded or chamfered on edges, complete all as specified and directed by Engineer - in - Charge.
M&L for rendering 15 mm thick in cement mortar (1:6) on fair face of brick walls, finished even & smooth without using extra cement, complete all as specified and directed by Engineer - in - Charge.
M&L for rendering one layer of 10 mm thick in cement mortar (1:4) on fair face of brick walls & rendering 5 mm thick over first layer, mixed with water proofing compound (ISI marked) @ 3% by weight of cement or as per manufacturer’s instructions, finished even & smooth without using extra cement complete all as specified and directed by Engineer - in - Charge. Note:- Supply only water proofing compound shall be measured and paid for separately.
M&L for rendering 5 mm thick in cement mortar (1:3) on concrete surfaces as in ceiling, finished even & smooth without using extra cement complete all as specified and directed by Engineer - in - Charge.
Supply only integral water proofing compound, ISI Marked complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of New plastered Internal wall surface complete applying the following :- (a) Wall care putty in two coats on wall surface (1.5mm thick each coat) and smoothening the surfcae with sand papers / Mechanised sanding etc prepatory to paint as directedcoomplete all as specified (b) Two coats of acrylic emulsion over a coat of acrylic primer using Airless spray / Roller over complete all as specified Note : Contractor may use manual scraping tools for complete removal and surface preparation with prior approval of Engr-in-chrge in case of places where using of Mechanical equiment are not posiible
M&L for preparation of New external plastered wall surface complete all as specified complete all as specified and applying the following :- (a) Applying wall care putty in two coats on wall surface (1.5mm thick each coat) and smoothening the surface with sand papers / Mechanised sanding etc prepatory to paint as directed complete all as specified (b) Two coat of exterior acylic emulsion using Airless spray / Roller over and incl a coat of acrylic emulsion external primer. Note: Contractor may use manual scraping tools for complete removal and surface preparation with prior approval of Engr-in-chrge in case of where using of Mechanical equiment are not posiible
M&L for applying two coat of white wash on newly plastered surface of ceiling including preparation of surfaces complete all as specified and directed by Engineer - in - Charge.
M&L for complete removal of existing treatment including filling depression of scraped surface with wall care putty in two coats (1.5mm thick each coat) on old internal wall surface and smoothening the surfcae with sand papers / Mechanised sanding etc prepatory to paint as specified and directed complete and applying two coat of acrylic emulsion of approved tint over a coat of primer on old prepared surface by using Airless spray / Roller over complete all as specified & directed. Note:- Contractor may use manual scraping tools for complete removal and surface preparation with prior approval of Engr-in-chrge in case of places where using of Mechanical equiment are not posiible
M&L for complete removal of existing surface finishes of ceiling and applying two coats of acrylic emulsion on old plasterd ceiling surfaces after preparation complete all as specified and directed by Engineer - in - Charge.
M&L for complete removal of existing treatment including filling depression of scraped surface with wall putty two coats (1.5mm thick each coat) on Old external wall surfaces of any desciption , preparation of surface by Mechanised sander having suction vaccum Bag using Smart periodical methodology , complete all as specified and applying the following :- (a) Two coats of exterior acylic emulsion by using Airless spray / Roller over and incl a coat of acrylic emulsion external primer. Note:- Contractor may use manual scraping tools for complete removal and surface prepration with prior approval of Engr-in-chrge in case of where using of Mechanical equiment are not posiible
M&L for preparation of old surface including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and making surface even and smooth and appplying two coats of acrylic emulsion on old decorated plastered or un-plastered surfaces of walls complete all as specified & directed by Engineer-in-Charge.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust and Brushing neat cement slurry @ 3.0 kg of cement per sq. metre, complete all as specified and directed by Engineer - in - Charge.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed by Engineer- in-Charge.
M&L for 10mm thick PGVT tiles double charged (square/rectangular), polished, coloured (light shade as approved), area of each tile not exceeding .36 sqm as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar (1:4) complete all as specified and directed.
M&L for 10mm thick PGVT tiles double charged (square/rectangular), polished, coloured (light shade as approved), area of each tile not exceeding .36 sqm, as in vertical surface like dado/ skirting etc , set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering in cement & sand mortar (1:4) complete all as specified and directed by Engineer - in - Charge.
M&L for 7 to 8 mm thick non skid ceramic edge cut tiles (coloured) (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar (1:4), complete all as specified and directed by Engineer - in - Charge.
M&L for glazed ceramic tiles (coloured) 600x300x 7mm thick on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10 mm thick rendering (as backing coat) in cement & sand mortar (1:4), complete all as specified and directed by Engineer - in - Charge.
M&L for 75 mm thick PCC (1:3:6) type C2 using 40 mm graded crushed stone aggregate as in plinth protection surface finished fair and even complete all as specified and directed by Engineer-in-Charge. Note :- Plinth protection shall be of width as directed and shall be laid to slope of 1:30 in alternative bays not exceeding 3 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3).
M&L for 25 mm thick PCC (1:2:4) type B0 using 12.5mm graded crushed stone aggregate as in flooring finished fair & even complete all as specified and directed by Engineer - in - Charge.
Taking up or down GI tubing 15 mm bore pipe including cleaning for re-fixing or removal to store complete all as specified and directed by Engineer - in - Charge.
S&F GI tubing 15 mm bore medium grade with all fitting and fixed to walls & ceilings or laid in floors, complete all as specified and directed by Engineer - in - Charge.
All as per itme No. 33 above but except GI Pipe. Note:- GI pipe retrieved from item no 32 shall be used.
Taking up or down GI tubing 20 mm bore pipe including cleaning for re-fixing or removal to store complete all as specified and directed by Engineer - in - Charge. .
S&F GI tubing 20 mm bore medium grade with all fitting and fixed to walls & ceilings or laid in floors complete all as specified and directed by Engineer - in - Charge.
All as per itme No. 36 above but except GI Pipe. Note:- GI pipe retrieved from item no 35 shall be used.
S&F in repairs vitreous china wash down water closet pan (Pedestal pattern), white, including connection to drain (or outgoing pipe) and to flushing pipe, anti-sypohonage pipe etc., with plastic WC seat cover (white) closed pattern with flat bottom and cover and mild steel chromium plated or aluminized hinging device complete all as specified and directed by Engineer - in - Charge. Make: Cat No C0297 of Elite Collection of Parryware orequivalent in Cera, Hindware, Johanson, Somany
S&F in repairs vitreous china squatting pan (Orissa pattern) water closet (white) of size 580x440mm with integral foot rests, 'P' or 'S' trap, including connection to trap and flushing pipe, antisyphonage pipe etc including provision of PCC (1:5:10) type E2 in filling, making good to floor, complete all as specified and directed by Engineer - in - Charge. Make: Cat No C0117 of Claret Collection of Parryware or equivalent in Cera, Hindware, Johanson, Somany
S&F in repairs PVC valveless syphonic action type low level flushing cistern (ISI marked) of 10 litre capacity including 32 mm dia PVC flush pipe connected to water closet with inlet, ball valve, float and handle complete all as specified and directed by Engineer - in - Charge. Make: Cat No E8109/E8057 of Claret Collection of Parryware or equivalent in Cera, Hindware, Hindustan
S&F in repairs vitreous china wash hand basin, white, bowl type for table top of size 450mm x 355mmx 130mm with & including a pair of cast iron brackets embedded in PCC (1:3:6) type C1 blocks of size 10x7.5x15cm, 32 mm dia PVC waste pipe and 32mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, (excluding tap, waste chain & plug), complete all as specified and directed by Engineer - in - Charge. Make: Cat No G8845 of Claret Collection of Parryware or equivalent in Cera, Hindware, Grohe, Kohler
S&F in repair Stainless Steel grating 125mm dia with waste hole (Minimium weight 40 grams) complete all as specified and directed by Engineer - in - Charge.
S&F in repair Stainless Steel grating 100mm dia without hole (Minimium weight 25 grams) complete all as specified and directed by Engineer - in - Charge.
S&F PVC connection 450 mm long with CP brass nuts on both sides suitable for 15 mm bore GI pipe complete all as specified and directed by Engineer - in - Charge.
S&F in replacement 15mm bore long body bib tap, cast copper alloy, chromium plated with capstan head, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed by Engineer - in - Charge. Make: Cat No G5206A1/T4606A1 of Claret Collection of Parryware or equivalent in Jaquar, Kohler, Grohe, Somany, Cera and Prayag
S&F in replacement CP angle valve for 15 mm bore pipe with capstan head long screwed shank including CP cover plate fancy type complete all as specified and directed by Engineer - in - Charge. Make: Cat NoG5207A1 of Claret Collection of Parryware or equivalent in Jaquar, Kohler, Grohe, Somany, Cera and Prayag
S&F in replacement CP two way angle valve for 15 mm bore pipe with capstan head long screwed shank including CP cover plate fancy type complete all as specified and directed by Engineer - in - Charge. Make: Cat NoG5243A1 of Claret Collection of Parryware or equivalent in Jaquar, Kohler, Grohe, Somany, Cera and Prayag
S&F in replacement CP two way bib tap for 15 mm bore pipe with capstan head long screwed shank including CP cover plate fancy type complete all as specified and directed by Engineer - in - Charge. . Make: Cat No G5234A1 of Claret Collection of Parryware or equivalent in Jaquar, Kohler, Grohe, Somany, Cera and Prayag
S&F in replacement 15mm bore concealed type, stop valve cast copper alloy screwed down high pressure with capstan head and cup, screwed both ends for iron pipe or for union complete all as specified and directed by Engineer - in - Charge. Make: Cat No G4612A1 of Claret Collection of Parryware or equivalent in Jaquar, Kohler, Grohe, Somany, Cera and Prayag
S&F in replacement central hole wash basin mixer 15mm bore brass without polp up waste with 10mm dia 450mm long copper pipes complete all as specified and directed by Engineer - in - Charge. Make: Claret Collection of Parryware or equivalent in Jaquar, Kohler, Grohe, Somany, Cera and Prayag
S&F in replacement CP single lever concealled High flow diverter body including upper trim for bath and shower system complete all as specified and directed by Engineer-in-charge. Make: Cat No G5285A1 of Claret Collection of Parryware or equivalent in Jaquar, Kohler, Grohe, Somany, Cera and Prayag
S&F in replacement Brass CP Kitchen Mixer for mixing hot and cold water screwed down for iron pipe complete all as specified and directed by Engineer - in - Charge. Make: Claret Collection of Parryware or equivalent in Jaquar, Kohler, Grohe, Somany, Cera and Prayag
S&F in replacement shower health faucet to EWC ,CP brass with minimum 1000mm long CP flexible pipe, connection etc., complete all as specified and directed by Engineer-in-Charge
S&F in replacement toilet paper holder, brass chromium plated fixed to walls with chromium plated (CP) brass screws complete all as specified and directed by Engineer-in-Charge. Make: Cat Part No T6505A1 of Parryware or equivalent in Jaquar, Kohler, Grohe, Somany
S&F in replacement CP brass soap dish of fancy type fixed to plug with chromium plated brass screw complete all as specified directed by Engineer-in-Charge.
S&F in replacement glass corner self assembly, fancy type, made of 5 mm thick sheet toughened glass of size 250x250mm, fixed with CP brackets, complete all as specified and directed by Engineer - in - Charge. Make: Cat No T6010A1 of Standard Collection of Parryware or equivalent in Jaquar, Kohler, Grohe, Somany
S&F 5 mm thick and 450 mm long 200mm wide glass shelves fancy type and fixed over CP brass brackets complete all as specified and directed by Engineer-in-charge.
S&F in replacement CP brass towel rack, 20mm dia, ‘D’ type, 60cm long between flanges, fixed to PVC rawl plugs with chromium plated brass screws, complete all as specified and directed by Engineer - in - Charge. Make;-Cat No T60008A1 of Claret Collection of Parryware or equivalent in Jaquar, Kohler, Grohe, Somany.
S&F 40mm bore PVC low density (LDPE) pipe of pressure 6kg/Cm2 fixed to wall or laid in floor, complete all as specified and directed by Engineer - in - Charge.
S & F in repair bottle trap of PTMT 32mm dia having minimum water seal of 25mm (min weight 260gm) complete all as specified and directed by Engineer-in-charge.
S&F in repair brass chromium plated shower rose 125 mm size without swivel joint including fixing to steel pipe of 15mm bore or union complete all as specified and directed by Engieer-in-charge. Make:-Cat No T9851A1 of Claret Collection of Parryware or equivalent in Jaquar, Kohler, Grohe, Somany.
S&F in repair cast iron floor trap of 75 mm bore, with grating including jointing to waste pipe, fixed in cement concrete type B1 (1:2:4), complete all as specified and directed by Engineer - in - Charge.
S&F in replacement cabinet of PTMT with looking mirror of size 350x555mm complete all as specified and directed by Engineer-in-charge. Make:-Cat Part No. MCB-251 of Prayag/Pearl/Shakti
S&F in replacement double bowl stainless steel sink made of 1mm thick sheet for kitchen with plugs, washers and wastes, including fixing with cast iron cantilever brackets, bedding in cement mortar on to dwarf wall, connecting union to pipe, overall minimum size 940mm x 455 x 250 mm with including 32mm dia waste pipe of polythelene of low or high density, 32mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, making holes in walls for brackets and fixed in CM (1:3) or PCC (1:2:4) type B0, complete all as specified and directed by Engineer-in-Charge. Make: Nirali/Neelkanth/Diamond
S & F in replacement stainless steel Kitchen plate rack of overall minimum size 900mm x 750 mm x 250mm deep, with partitions for small/large plates etc made out of stainless steel 0.80 mm thick sheet fixed with rawl plug and CP steel screws complete all as specified and directed by Engineer - in - Charge.
S&F in repairs stainless steel curtain rod 25 mm dia (minimum weight 0.36 Kg per RM) with brackets, fancy knobs and rings (20 cm c/c) etc complete all as specified and directed by Engr-in-charge.
M&L for 18 to 20 mm thick Granite (of any type) slab of approved shade as in kitchen platform,steps,jambs,pillars,window cills,cooking plateforms etc, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match with shade of Granite stone including cutting, grinding and polishing (mirror polish) i.e. full granite polish as per local trade practice) over & including 20mm thick screed bed (bedding layer) in CM (1:4), complete all as specified and directed by Engineer - in - Charge.
Dismantling PVC water tank/RCC tank and removing for capacity exceeding 250 litres & not exceeding 500 litres and removing from site complete all as specified and directed by Engineer - in - Charge.
Dismantling PVC water tank/RCC tank of water tanks of capacity exc 500 Ltr & n.exc 1000 Ltr and removing from site complete all as specified and directed by Engineer - in - Charge.
S&F 1000 Litre capacity Rotational moulded polyethylene water storage tanks Triple layered White coloured (cylindrical, vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc complete all as specified and directed by Engineer - in - Charge.
S&F 500 Litre capacity Rotational moulded polyethylene water storage tanks Triple layered White coloured (cylindrical, vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc complete all as specified and directed by Engineer - in - Charge.
S&F in replacement 20 mm ball valve high pressure of PTMT with apoxy coated aluminium rod and high density plastic ball screwed for iron pipe, complete all as specified and directed by Engineer - in - Charge.
S&F in replacement gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 20 mm bore, all as specified and as approved by GE/Engineer-in-Charge.
S&F in replacement Aluminium peg set consisting of 6 pegs on aluminium flat of standard section, all as approved by GE/Engineer-in-Charge.
M&L for block board, 19/20mm thick, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame work as in cup board shutter/shelves/cabinet etc, complete all as specified and directed by Engineer - in - Charge.
S&F 40mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed by Engr-in-charge.
M&L for 0.90mm thick decorative laminates 'Mica type 1 of surface finished,colour and pattern as approved, fixed with adhesive as per makers instructions complete all as specified and directed by Engineer - in - Charge. .
S&F door viewer vide angle brass with glass cap 14 mm dia complete all as specified and directed by Engineer-n-charge.
M&L for mortice lock with two lever (vertical type) with brass body 100 mm long complete all as specified and directed by Engineer - in - Charge. Make:- Godrej:- Euro/ profile mortice ICK-1614/2c 1615 with handle, Or 1001/Bullet in Link.
S&F 25 mm size magnetic catches with Plastic body and striking plate including letting in and fixed complete all as specified and directed by Engineer - in - Charge.
S&F continuous (piano) hinges 30mm width of flap when opened, mild steel bright finish or electrogalvanised fixed with CP steel screws complete all as specified and directed by Engineer - in - Charge.
M &L in repair for providing Modular Kitchen Cabinet/cup board with shutters in required sizes & shape at site made out of 18 mm thick one side decorative laminate and other side balancing lamination sheet consisting of carcass 18 mm thick PVC sheet & PVC sheet with all required brackets SS screws e.t.c. The panels shall be fabricated using adhesive and screws wherever required . All the edges shall be covered with 2 mm thick edge bonding tape or 90 degree edge bent finish as per manufacturer instructions and as directed by Engineer-in-Charge.
S&F in repair cup Saucers fabricated with stainless steel section (SS-304), best quality of size 420 mm x 500 mm x 100mm for different use such as placing plain plate /cutlery etc fixed in position complete all as specified and directed by Engr In charge
S&F in repair Cutlery set & Dustbin fabricated with stainless steel section (SS-304), best quality of size 420 mm x 500 mm x 150 mm for different use such as placing cup & saucer etc fixed in position complete all as specified and directed by Engr In charge
S & F in repair Stainless steel fancy type 200 mm handle complete all as specified and directed by Engr In charge.
S & F Telescopic Ball bearing Channel chromium plated of size 500 mm (when closed) fix to kitchen basket complete all as specified and directed by Engr In charge Make:- godrej, Link,Hettich
S& F Auto Closing Concealed Hinges for Half Overlay Doors with 95 Degree Opening Angle complete all as specified and directed by Engr in charge
Supply & fixing hasp and staple of size 75 mm aluminium anodized safety type with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed by Engineer - in - Charge.
Taking down chowkhat with shutter (without taking off shutter from the frame) and area exc 1.5 sqm but n.exc 4 sqm each complete all as specified and directed by Engineer - in - Charge.
Taking down chowkhat with shutter (without taking off shutter from the frame) and area not exc 1.5 sqm each complete all as specified and directed by Engineer - in - Charge.
Taking down shutter of any description exc 1 Sqm and not exc 2 Sqm each and refixing in same opening including easing and adjusting of shutter as required including renewal of unserviceable screws complete all as specified and directed by Engineer - in - Charge.
S&F Pressed steel frames of size 125 X 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, (thickness of sheet shall be 1.25mm) and making good the wall with plaster in CM (1:6) complete all as specified and directed by Engineer - in - Charge.
S&F pressed steel frames of size 105 X 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, locks strike plate etc, (thickness of sheet shall be 1.25mm) and making good the wall with plaster in CM (1:6) complete all as specified and directed by Engineer - in - Charge.
M&L PCC (1:3:6) type C-0 using 12 mm graded stone aggregate for filling in back of pressed steel door frame/chowkhat and fixing of bed block of hold fast etc complete all as specified and directed by Engineer - in - Charge.
S&F 2nd class HW factory made Plain, framed, pannelled shutters 35 mm thick (two panels), with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS:1003 (Part I) Kiln seasoned and chemically pressure treated complete all as specified and directed by Engineer - in - Charge.
S&F 2nd class hardwood glazed skeleton shutters 35 mm thick open rebated and prepared to receive guage etc divided into squares, with plain chamfered or rounded, mitred and rebated sash bars any numbers complete all as specified and directed by Engineer - in - Charge. Note:- necessary beading used for securing the wire mesh rates included in this items)
M&L for Plain fillets or beading of sectional area Exc 3 & n. exc 6 sq.cm of 2nd class hard wood square, rectangular or triangular in section , clean sawn, secured with nails or beads for securing wiremesh or similar works put together with glue pinned at joints in complete all as specified and directed by Engineer - in - Charge.
S&F Solid FRP Door Frame of size 90mm x 45mm with single rebate of 32mm x 15mm to receive shutter moulded with fire retardent grade and saturated polyster resin and choped mat door framed shall be 2 mm thick and fill with suitable block in all the three legs the freme shall be covered with fiber glass rom all side MS stay shall be provided at the bottam to steady the frame . as per specification shown on drawings complete all as specified and directed by Engineer - in - Charge. .
S&F factory made solid panel FRP door shutter shall be 30mm thick (style) glass fibre reinforced plastic panel door shutter of requred colour with fire retardent grade and saturated polyster resin moulded to 3 mm thick FRP liminated for forming hollow rails and style with wodden frame and suitable block of seasoned wood inside at reqd places for fixing of fittings cast monolithically with 5 mm thick FRP panel and conforming to IS 14856:2000. suppling and fixing in the frame at site as per specification shown on drawings complete all as specified and directed by Engineer - in - Charge.
S&F butt hinges of size 100 mm medium weight, stainless steel ISI marked complete all as specified and directed by Engineer - in - Charge.
S&F in repair butt hinges of size 100 mm medium weight, stainless steel ISI marked complete all as specified and directed by Engineer - in - Charge.
S&F aluminium handle, 150mm size, cast type, anodized (ISI marked) complete all as specified and directed by Engineer - in - Charge. Note:- D type Handle and back side staple.
S&F in repair aluminium handle, 150mm size, cast type, anodized (ISI marked) complete all as specified and directed by Engineer - in - Charge.
S&F 200 mm long aluminium anodized barrel tower bolts of extruded section (ISI marked) complete all as specified and directed by Engineer - in - Charge.
S&F in repair 200 mm long aluminium anodized barrel tower bolts of extruded section (ISI marked) complete all as specified and directed by Engineer - in - Charge.
S&F 300 mm long mild steel sliding door bolts, plate type, stove enameled black, with bright bolt not less than 12mm dia and including a minimum of 06 bolts and nuts, four on bolt plate and two on staple plate and fixedcomplete complete all as specified and directed by Engineer - in - Charge.
S&F in repair 300 mm long mild steel sliding door bolts, plate type, stove enameled black, with bright bolt not less than 12mm dia and including a minimum of 06 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all as specified and directed by Engineer - in - Charge.
S&F mild steel helical door spring 300mm ordinary rat tail rod pattern spring including roller and roller plate complete all as specified and directed by Engineer - in - Charge.
S&F small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, articles of 2nd class hardwood, articles not exc 200 cu.cm each complete all as specified and directed by Engineer - in - Charge.
S&F in repair 150mm length floor door stopper of aluminium alloy body and tongue,anodised with hard drawn steel spring fixed in floor complete all as specified and directed by Engineer - in - Charge.
S & F hasp and staple, safety type of aluminium anodised100mm size fixed with screw complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying a coat of red oxide zinc chrome primer and two coats of synthetic enamel paint including preparation of surface complete all as specified and directed by Engineer - in - Charge.
M&L for preparing new wood or wood based surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of old painted steel surfaces of any description over 10cm width or grith and surfaces applying two coat of synthetic enamel paint (ordinary tint) complete all as specified and directed by Engineer - in - Charge.
M & L for applying two coat of synthetic enamel paint over a coat of pink primer after complete removal of existing treatment with grinding and filling joints with putty wood and wood based surfaces of any description, over 10cm width or girth, not other wise described including preparation of old painted surfaces complete all as specified and directed by Engineer - in - Charge.
S&F mild steel framed work such as grills, guard bars, barred iron doors, cooler stand, framework of water tanks and similar works, conforming to Grade E-165 (Fe 290), including welding etc complete all as specified and directed by Engineer - in - Charge.
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire, staples complete all as specified and directed by Engineer - in - Charge.
S&F in repair stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire, staples complete all as specified and directed by Engineer - in - Charge.
Dismantling Posts or struts (steel or RCC) any section ,including taking out embedded portion and making good disturbed ground post embedded in concrete complete all as specified and directed by Endineer -in -Charge.
Dismantling of fencing wire mesh of any type and size complete all as specified and directed by Engineer - in - Charge.
Excavating in post holes in soft/loose soil (or similar holes) each n exc 0.5 cu.m. getting out, returing, filling in and ramming earth or broken ruble mixed with earth around, in layers not exceeding 25 cm , watering, and removing surplus soil to a distance n exc 50 M and making good surface complete all as specified and directed by Engineer-in-Charge.
M&L PCC (1:3:6) using 40mm graded stone aggregate type C2, as in foundation of posts and struts complete all as specified and directed by Engineer -in -Charge.
M&L for mild steel work as in post and struts in fencing including cutting tops to shape, drilling holes, notching for wire etc conforming to Fe-290 grade E-165 complete all as specified and directed by Engineer - in - Charge.
M&L for mild steel flat iron for fixing chin link or hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and clounter sunk for balusters running bars, for doors, balusters, nosing to steps including embneding in concrete and screwing etc wid ties for roof including securing bolts, posts and struts in fencing including cutting tops shape as directed, drilling holes, notching for wire etc flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or reveting etc, and similar work conforming to Fe-290 or Fe-165 complete all as specified and directed by Engineer-in-Charge
M&L for preparation of new untreated steel and iron surfaces of any description, not exc. 10 cm in width or girth when unconnected with other painting or when painted in a different tint and applying two coats of synthetic enamel paint over a coat of zinc chrome primer complete all as specified and directed by Engineer - in - Charge.
S&F 10mm dia MS round bar for fixing of chain link fencing with post complete all as specified and directed by Engineer - in - Charge.
Supply only chain link fencing galvanised mild steel of mesh 75mm X 75mm size 3 mm dia complete all as specified and directed by Engineer - in - Charge. Note:- The weight of chain link fencing shall be ascertained by BOO as directed by GE and payment shall be paid accordingly .BOO duly countersigned by GE shall be enclosed with final bill.
Fixing only chain link fencing line wires,any mesh, size including line wire,any mesh,size and any type of standared ,rails,straining bolt, etc complete all as specifed and directed by Engineer-in-Charge. Note :- Supply of chain link fencing wire be measured and paid Separately.
S&F mild steel screw bolts (machine made) with hexagonal or square head at one end, and screwed the other,or screwed both end to be fitted with washer and one hexagonal/ square nut not exceeding 5cm long and dia of neck 11 to 15mm complete all as specified and directed by Engineer-in-Charge.
Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed by Engineer-in-Charge.
M & L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe-290(Grade E-165) complete.
Dismantling AC sheet (Corrugated, Semi corrugated etc) as in roofs etc including ridges complete all as specified.
S&F 0.50 mm thick pre-painted galvalume aluminium zinc coating galvanised iron based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws complete all as specified and directed by Engieer-in-Charge.
S&F steel work in tubular trusses or (round pipe used for purlins,vertical post etc for shed)including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to is.1161-1998 grade St-240 complete all as specified and directed by Engineer-in-Charge.
M&L for hardcore of broken brick aggregate, gauge not exc. 63mm, deposited, spread and leveled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
M&L for 75 mm thick PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in sub base, surface finished fair and even complete all as specified and directed by Engineer-in-Charge.
M&L for factory made 60mm thick reflective type rubber moulded machine pressed precast cement concrete interlocking paver blocks of Grade M-35 conforming to IS 15658-2006 of shape and size as directed with grey cement and no pigment laid over & including 25mm thick sand cushioning, joints of blocks filled with dry sand and compacted with mechanical vibrator complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete (1:2:4) type B0, using 12.5mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates and the like including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified and directed by Engineer-in-Charge.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc complete all as specified and directed by Engineer-in-Charge
M&L for cement concrete (1:3:6) type C1 using 20 mm graded crushed stone aggregate as in surface channels, drains, coping and benching including necessary formwork whrever required. Note : Forming fair finished channel for drain using extra cement shall be measured and paid for separately.
Demolition and breaking up or taking down PVC/AC/CI/SSW 100mm bore pipe drain pipes, set in cement mortar including PCC haunching and bedding complete all as specified and directed by Engineer-in-Charge
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall including PVC holding clamps complete all as specified and directed by Engineer-in-Charge
S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall including PVC holding clamps complete all as specified and directed by Engineer-in-Charge.
S&F 110mm bore PVC (SWR) bend, any radius with access door.
S&F 75mm bore PVC (SWR) bend, any radius with access door.
S&F 110mm bore PVC (SWR) vent cowl.
S & F Stack clamps out of 50mm by 5 mm flat iron and 16mm dia round iron stays for 100mm bore of pipe, including bolts and nuts and securing ends of stays to wall or roof etc complete all as specified and directed by Engineer - in - Charge.
S&F in repair ornamental and intricate design mild steel framed work as in doors / gates / steel frames etc. of angle or other sections with gusset plates, rails, braces, etc., complete conforming to Grade E-165 (Fe 290), drilled for fixing of steel sheeting or other covering (exclusive of steel sheeting or other covering) including necessary welding etc with & including framed portion hung as gates including pintle hinges, stops, hand made sliding bolts etc complete all as specified and directed by Engineer-in-Charge
S&F Aluminium frame for doors, window, ventilators with one or more rebates including joining cleat for fixing etc complete with powder coating on Aluminium minium thickness of powder coating 50 micron as per the specification the top and bottom horizontal members and vertical members adjacent walls shall be fixed with floor, ceiling walls and cills where required and fixing with the help of rawal plug and screw or with fixing clip or with expansion hold plate fasteners . Aluminium section shall be smooth, rust free, straight mitred and jointed mechanically where ever required all complete as per the direction of Engineer-in-charge
S&F Aluminium window (glazed and gauzed both),side hung type without sash bars, aluminum section weighing not less than 0.55 Kg/m including necessary joining cleats, glazing, clips, rubber packing, anodised aluminium snap beading screws,aluminium fitting such as peg stays 150mm long (01 nos), hinges type B-21 100mm long (02 Nos) suitable handle (01 No) with powder coating of any colour (thickness of powder coating not less than 50micron) etc complete all as specified and directed. Note: Only Glass and wiremesh will be measured and paid seperately.
S&F Alumunium powder coated ventilator including frame and shutter and provision of neccessary rubber gasket for fixing glass panes complete all as specified and directed by Engineer-in-charge. Note : Glass panes and wiremesh shall be measured and paid seperately under respectively Items .
S&F anodized aluminium grill powder coated of approved pattern of mesh 80x80mm, 6mm dia bars using U channel 25x12mm for windows / ventilators / doors complete, all as directed .
S&F 5.0 mm thick sheet glass ordinary quality in square not exceeding 0.5 sqm in each pane complete all as specified and directed .
Demolition of Cement concrete (unreinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed by Engineer-in-Charge
M& L for water proofing treatment to sunken slab and adjjoining vertical surfaces complete all as specified and directed by Engineer-in-charge as under :- (a) M&L rendering 10 mm thick in cement plaster (1:3) using coarse sand mixed with integral water proofing compound trowel even and smooth with steel trowel on sunken surfaces (Note : WPC shall be measured and paid separately) (b) Applying first coat of chemical pidifin 2K(Dr Fixit) on cleared RCC surfaces @ 0.86 Kg/Sqm (Minimum) as recommended by manufacturer. (c) Provide a layer glass fibre mesh of size 2.25mm x2.25mm (45 GSM) over first coat of chemical Pidifin 2K as per manufacturers recommendation. (d) Applying second coat of chemical Pidifin 2K (Dr Fixit) @ 0.86 Kg/Sqm (minimum) layer glass fibre mesh of size 2.25mm x 2.25mm (45 GSM) as recommended by manufacturers.
M&L for PCC 1:5:10, type E-2 as in filling of sunken floors etc.complete all as specified and directed by Engineer-in-Charge
M&L 40 mm GI pipe medium grade, made to shape as in spout pipe in sunken/ verandah/ Balcony complete all as specified and directed by Engineer-in-Charge
M&L for 30 cm x 30 cm x (20 to 25) mm thick chequered cement concrete tiles(rubber moulded) set jointed and pointed in neat cement slurry in floors with grey cement including 15mm thick screed in CM (1:6) with pigments complete all as specified and directed by Engineer-in-Charge.
M&L for Machine cut kota stone slab flooring, cills 20-25mm thick including 20 mm thick screed bed in cement mortar (1:6) base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and directed by Engineer-in-charge.
M& L for machine cut Kota stone slab 20-25 mm thick as in riser of steps, dado, pillars and skirting including 10 mm thick rendering in cement mortar (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and directed by Engr-in-charge.
Demolition of RCC slabs, chajjas and similar items complete all as specified and directed by Engineer - in - Charge.
M&L for reinforced cement concrete type A1 (1:1.5:3) (20 mm graded aggregate) as in slab supported on walls, beam and column in floors, roofs,landings,balconies,deck slab and in shelves and etc and setting in mortar complete with joints to match complete all as specified and directed by Engr-in-charge.
Repair to damaged concrete slab by using micro mortar and concrete in following stages:-(a) Removing the falling mortar and concrete from RCC slab and cutting the affected area in geometrical shape.(b) Cleaning the rusted reinforcement and applying rust removal.(c) Inserting addl reinforcement in case the cross sectional area reduction is more than 20 percent. Welding the reinforcement with existing one and supporting the new supporting adequately on walls if required with grout.(d) Providing micro mortar and concrete over bond coat to cover the reinforcement and slab surface.(e) Providing adequate formwork and scaffolding if required.(f) Curing the surfaceRust removal, Bonding agent, grout, micro mortar and concrete and related chemicals shall be of Dr Fixit/BASF and STP. Work is to be got executed from authorized applicators of company.
Use and waste of form work rough finished surface of soffits of suspended slab as roof slabs, floor, lamnding and similar work not exceeding 200 mm thick complete all as specified and directed by engr-in-charge.
M & L mild steel TMT bars 6 to 8mm dia , cut to length, bent to shape required, including cranking, bending, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia complete all as specified and directed by Engineer - in - Charge.
Dismantling cast iron work of any description and any position complete all as specified and directed by Engineer - in - Charge.
S&F 100mm bore cast iron sand cast soil, waste and vent pipes, in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed by Engineer - in - Charge.
S&F 75mm bore cast iron sand cast soil, waste and vent pipes, in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed by Engineer - in - Charge.
S&F 100mm bore cast iron bends sand cast (any radius), diminishing pieces or tapers (larger bore measured) fitted with oval access door complete all as specified and directed by Engineer - in - Charge.
S&F 75mm bore cast iron bends sand cast (any radius), diminishing pieces or tapers (larger bore measured) fitted with oval access door complete all as specified and directed by Engineer - in - Charge.
S&F 100mm bore cast iron bends (any radius) with duck's foot or heel rest complete all as specified and directed by Engineer - in - Charge.
S&F 18/19 mm prelaminated particle board ,Exterior grade ,preliminated both sides with decorative choice laminations fixed with screws complete all as specified and directed by Engineer - in - Charge. .
S&F 75mm bore cast iron bends (any radius) with duck's foot or heel rest complete all as specified and directed by Engineer - in - Charge.
S&F 100mm bore cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branchest complete all as specified and directed by Engineer - in - Charge.
S&F 75 mm bore cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branchest complete all as specified and directed by Engineer - in - Charge.
Extra over 100 cast iron pipes and fittings if lead joint is provided in lieu of cement joint
Extra over75 mm cast iron pipes and fittings if lead joint is provided in lieu of cement joint
M&L for CI floor trap 75 mm with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) all as specified and directed by Engr-in-charge.
M&L for CI floor trap 100 mm with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) all as specified and directed by Engr-in-charge.
Taking down carefully aluminium point wiring (light, fan, socket or power, bell complete fitting such as sockets, ceiling roses, pendants, batten holders, regulators and making good the disturbed surfaces of wall, floors, ceiling in CM 1:3 etc complete all as specified and directed by Engineer-in-Charge.
M & L for concealed conduit point wiring complete for light/ fan on independent /combine board with cable 1.5 sqmm (Nominal area) FRLSH PVC insulated multistranded unsheathed copper conductor, drawn in and including PVC Concealed conduit pipe medium grade 20 mm dia, pipe hooks , elbows, juction covers and junction boxes , after cutting in wall chasing for conduits and sinking's for modular metal flush boxes suitable length and 2.00mm thickness for mounting, switches, sockets,fan regulator with modular cover plate with frame and making the good disturbed surfaces of wall in CM 1:3 with white wash or existing colour including provision of continuous earth continuity conductor along with point wiring of 1.5 sqmm copper PVC insulated cable for one light/ fan point controlled by one switch and connected to common earth dolly, complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 182 here in before but for one switch socket combination 5/6 amp on independent board.
All as per Srl item No. 182 here in before but for one three pin socket outlet 5 Amp on same board with other switches.
All as per Srl item No. 182 here in before but for one switch socket combinationt 6 pin 5/ 15 Amps on independent board with copper conductor 2.5 Sqmm.
All as Srl item No. 182 here in before but for one light point controlled by two 2 ways switches.
All as Srl item No. 182 here in before but for call bell point.
S & F modular switch 5/6 Amps single pole one way,one module including moudlar cover plate with frame and modular metal flush box complete all as specified and directed by Engineer-in-Charge.
S & F modular switch socket combaination 5 Pin, type 5/6 Amps 5 in 1 flush type including moudlar cover plate with frame and modular metal flush box complete all as specified and directed by Engineer-in-Charge.
S & F modular switch socket combaination 6 Pin, type 15/16 Amps flush type including moudlar cover plate with frame and modular metal flush box complete all as specified and directed by Engineer-in-Charge.
S & F modular switch 5/6 Amps single pole two ways including moudlar cover plate with frame and modular metal flush box complete all as specified and directed by Engineer-in-Charge.
S & F modular socket outlet 5 pin, 5 Amps flush type icluding moudlar cover plate with frame and modular metal flush box complete all as specified and directed by Engineer-in-Charge.
Supply and fix industrial socket metal clad plug and socket with MCBs single pole 20 Amp complete all as specified and directed by Engineer-in-Charge.
S&F modular bell push 5 Amp icluding moudlar cover plate with frame and modular metal flush box complete all as specified and directed by Engineer-in-Charge.
S & F modular stepped type, fan regulator not less than 120 watt for ceiling fan 1200/1400mm sweep icluding moudlar cover plate with frame and modular metal flush box complete all as specified and directed by Engineer-in-Charge.
S&F Buzzer AC AC 230 Volt single pole ding dong type complete all as specified and directed by Engineer-in-Charge.
S & F ceiling rose surface bakelite three terminals complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of existing light fitting with LED batten with aliminium housing and integrated electronic driver, 20 watt having input voltage AC90-300V, 50 Hz , 6500K, and all other accessories including connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector complete all as specified and directed by Engineer-in-Charge. Make:Havells cat part No: LUMILINEPLUSBS20WLED865SPCSS , Bajaj cat part No.: BCLSBAL 20W CW ,Crompton cat part No. : CCS-100-20-65-HL2-DP-NWH or equivalent make as approved by GE
S&F in replacement security light fitting LED TYPE 25 watt with all necessary acessories, Clear transparent acrylic cover, prewire suitable to operated on 230 volt 50 HZ AC & Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 2 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed by Engineer-in-Charge. Make:Havells cat part no: ENDURAPEARLSL25WLED757SASYTOPCMP, Bajaj cat part no. BRLEP 25W LED WH, Crompton cat part no. LSTS-25-CDL-M or equivalent make as approved by GE
S&F in replacement decorative wall light, brushed nickle finish fixture with OPAL glass diffuser including 4 watt LED filament lamp E14 base complete all as specified and directed by Engineer-in-Charge. MAKE: HAVELLES CAT PART No. LHFOAIC1TZ1I040 or equaivalent in Bajaj/Cormpton
S&F in replacement LED Bedside light (White 3000k) 3 watt, with flexible arm suitable for reading complete all as specified and directed by Engineer-in-Charge. Make: Philips 48042, Havelles, Bajaj or equivalent
S & F in replacement Water tight bulk head fitting,comprision of connector galvanised cast iron back plate,weather proof enamelled gallery ,glass well,and including 10 watt LED lamp complete all as specified and directed by Engineer-in-Charge. Make:Havells cat part no : HEXAFT10WLED857SSYMBOPC, Bajaj cat part no. BIBWP 10W LED, Crompton cat part no. LBHP-10-CDL or equivalent make as approved by GE
S & F in replacement compact & decorative energy efficient LED mirror light fitting with antiglare diffuser and decorative end caps suitable for 1X10 watt fitting 2 ft version including LED lamp 10 watt complete all as specified and directed by Engineer-in-Charge. Make : Havells cat part no LUMILINEPLUSBS10WLED865SPCSS, Bajaj cat part no. BCLSB 10 WH, Crompton cat part no. LDL-10-CDL or equivalent make as approved by GE
S & F angle holder insulated body with back plate for conduit fittings complete all as specified and directed by Engineer-in-Charge.
S&F LED lamp 9W for angle holde complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of sub-main wiring with PVC insulated and un-sheathed 4 x 6.00 sqmm (Nominal Area) FRLSH stranded copper conductor drawn in and including PVC dia 32 mm “medium quality” conduit as per size required including 2 x 6.00 Sq mm (Nominal Area) copper cable as earth continuity conductor after chasing in wall and making good the disturbed surfaces and white wash or existing colour , necessary junction box and covers including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed by Engineer-in-Charge. (Note:- PVC cable and PVC conduit shall be ISI marked) Note:- Four lengths of 6.0 sqmm cable and two length of 6.0 sqmm earth cable along with PVC conduit will be measured as one running length
S&F in replacement sub main two single core PVC copper conductor unsheathed wire FRLSH multi stranded 4 sqmm including cutting chasing and grouting PVC pipe including Tee, Elbow, Bend etc and including 4.00 sqmm copper conductor single core wire connected by common earth all as specified. Including 20 mm dia concealed PVC conduit, medium grade, ISI marked complete all as specified and directed by Engineer-in-Charge. Note :- Two lengths of 4.0 sqmm cable and one length of 4.00 sqmm earth cable along with PVC conduit will be measured as one running length
S&F in replacement sub main two single core PVC copper conductor unsheathed wire FRLSH multi stranded 2.5 sqmm including cutting chasing and grouting PVC pipe including Tee, Elbow, Bend etc and including 2.5 sqmm copper conductor single core wire connected by common earth all as specified. Including 20 mm dia concealed PVC conduit, medium grade, ISI marked complete all as specified and directed by Engineer-in-Charge. Note:- Two lengths of 2.5 sqmm cable and one length of 2.5 sqmm earth cable along with PVC conduit will be measured as one running length
S & F in replacement sheet metal enclosure for double door Vertical DBs made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounting VTPN 4 ways, 415 Volts, ISI marked 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Sheet metal enclouser for doble door DBs made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mouted TP& N 6 Ways, 415 Volt ISI marked 200Amps busbar stove enameled dust and vermin proof suitable for incorporation MCBs and Isolators etc complete all as specified and directed by Engineer-in-Charge.
S&F in repairs MCCB TP&N 63 Amps with breaking capcity 16kA ,Fixed TM and 415 volts AC Supply ISI marked complete all as specified and directed by Engineer-in-Charge.
S & F in replacement MCB ‘B’ series type suitable for 415 volts, AC supply 40 Amps, triple pole and neutral with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer-in-Charge.
S & F in replacement MCB ‘B’ series type suitable for 415 volts, AC supply 40 Amps, triple pole with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer-in-Charge.
S & F in replacement MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 40 Amps , single pole with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer-in-Charge.
M&L for Earthing complete with GI earth plate electrode of size 600x600x6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI wire 4 mm dia earth lead by means of nuts, bolts, check nuts, washers of galvanised iron or steel, protected by galvanized iron pipe15mm bore (Light grade) all as directed including cement concrete (1:2:4) type B-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed after taking down old earthing complete all as specified and directed by Engr-In-Charge. Note: Cost of GI wire upto 7.5m including testing is included in the unit rate of item.
Dismantling and refixing of ceiling fans of any size including providing fan hooks clamps complete all as specified and directed by Engineer-in-Charge.
Dismantling and refixing of exhaust fans of any size including providing fan hooks clamps complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 mtr depth width and not exceeding 1.5m depth for laying under ground cable in loose/soft soil complete all as specified and directed by Engineer-in-charge.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25cm complete all as specified and directed by Engineer-in-Charge.
Removal of surplus soil obtained from excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-charge. .
M & L for sand cushioning with dry coarse sand to under ground cable 23 cm thick, 8 cm thick below the cable and 15 cm thick after laying the cable complete all as specified and directed by Engineer-in-Charge. Note : Thickness after punning shall be considered for payment.
M&L for laying burnt old size bricks , sub class "B" bricks straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified.
Supplying, laying, jointing, testing and commissioning in replacement of 35 Sqmm x 3.5 core XLPE insulated, screened , PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor & PVC sheathed LT cable 1100 V grade conforming to IS-7098 laid in trenches/ducts/fixed on poles wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge.
Supply and fix 3 pin telephone socket RJ 11 with metal flush box having holes for 20 mm conduit entry for telephone connection complete all as specified and directed by Engineer-in-Charge.
S & F Rigid non-metallic PVC conduit 20 mm dia inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed by Engineer-in-Charge.
Supplying and laying GI pipe 50 mm light grade for cable protection in walls trenches or any situation including clamp nut bolt etc complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of meter box of size (0.9mX0.9mX0.2m) , thickeness 2.25 mm double door,made of CRCA sheet, single opening with lock arrangement ,transperent glass for meter reading, suitable for fixing 04 Electric meter & VTPN DB box including taking down existing electric meters , refixing them with two single core PVC copper conductor unsheathed wire multistranded 4 sqmm,properly painting on meter box complete and fixing in wall with suitable cutting,cement work etc complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15mm bore long body bath spout with dicerter cast copper alloy, chromium plated for brass ferrule complete all as specified and directed by Engineer-in-Charge. Make: Cat No T4606A1 of Claret Collection of Parryware or equivalent in Jaquar, Kohler, Grohe, Somany, Cera and Prayag
M&L for two coat heat resistant aluminium painting on APP treated roof surface complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement exhaust fan complete metal body with louvers shutters AC single phase 230 Volt of size 300mm sweep by grouting both ends in wall upto required length and making hole suitable size inwall and connecting with ceiling roses with and including flexible cable 3 core copper conductor of size 23/.0076 of suitable length with complete all as specified and directed by Engineer-in-Charge. ---------------------------------------------------------------------------------------------------- Note : A sum of Rs. 125228.00 will be deducted on account of credit for taken down material. Please refer details on Srl Page No.44(R ) to 46(R ) (Schedule of Credit) of Tender documents.
KHANNA CONSTRUCTIONS
M/s Tarun Traders
M/S BUDHRAM BISHNOI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .