Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.3 LAccepted-AOC 344 1 SB GORAI ROAD HILL VIEW PARK NORTH ASANSOL | ASANSOL | WEST BENGAL | L1 | Accepted-AOC Accepted | |
| 2 | L2₹20.6 L+₹32,331.15 (1.59%)Rejected-Finance 18 SANKAR BOSE ROAD KOLKATA | L2 | Rejected-Finance Rejected | |
| 3 | L3₹20.8 L+₹46,607.73 (2.29%)Rejected-Finance 138 CANNING STREET GROUND FLOOR KOLKATA | KOLKATA | WEST BENGAL | L3 | Rejected-Finance Rejected | |
| 4 | L4₹20.9 L+₹57,809.45 (2.84%)Rejected-Finance BHAGIRATHIPUR DOMKAL MSD | DOMKAL | MURSHIDABAD | WEST BENGAL | 742101 | L4 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹46,000
Closing Date
27 Dec 2024, 6:00 pmClosed
Executive Engineer, BMD, PHE, Dte
Office of the Executive Engineer. Bankura Mechanical Division. P.H.E. Dte. Ailakundi, PO Kenduadihi, Bankura 722102.
Repairing and servicing of all H.T equipment in the Sub station at Ramjibanpur CWR site of Puncha water supply scheme of Block-Onda under Bankura Mechanical Division PHE Dte.
2024_PHED_779084_10
WBPHED/EE/BMD/NIeT-13 OF 2024-2025
Open Tender
MECHANICAL
Item Rate
60 days
Bankura
Please refer Tender documents.
5 documents required · 5 mandatory
₹46,000
Yes
5 Mar 2025
13 Dec 2024
30 Dec 2024
13 Dec 2024
27 Dec 2024
13 Dec 2024
Amount
Part-A 4 PANEL VCB
Supply delivery of O/C & E/F Relay Make: Schneider, Model: MICOM P111 / Easergy P1
Supply delivery of O/C & E/F relay replacement, Retro-Fitting /Modification& calibration charges (including retro-fiiting plate supply)
Supply delivery of 185 sq. mm. X 3 core, 11 KV grade, Indoor type, Heat shrinkable End Termination Kit
Supply delivery of 185 sq. mm., 11 KV grade, indoor type, Heat shrinkable Kit Jointing
Charges for 11 KV VCB Racked out from 11 KV panel, 11 KV VCB mechanism dismantling,11 KV VI Housing, main moving contact drive Insulator Dismantling, Rubbing, Cleaning done by applying CRC, WD-40. After that heating treatment done, then varnishing done by applying Red Insulation Varnish to improve the IR value, after improving the IR value finally re-fitting the 11 KV VI housing, main moving contact drive insulator, 11 KV VCB mechanism and after re-fitting 11 KV VCB Racked in and power charging done of Incomer, OG – 1, OG – 2 & Spare Panel
Charges for 11 KV HT cable disconnection, 11 KV CT primary & secondary side disconnection, 11 KV CT dismantling, rubbing, cleaning done by applying CRC, WD?40. After that heating treatment done, then varnishing done by applying Red Insulation Varnish to improve the IR value, after improving the IR value finally re-fitting the 11 KV CT, reconnecting the primary and secondary connection and termination of 11 KV HT cable and power charging OG – 1, OG – 2 & Spare Panel
Charges for 11 KV CT Spouts & Busbar Spouts Dismantling from Panel, Rubbing, Cleaning by applying CRC, WD-40, Varnishing by applying Red Insulation Varnish and Heating treatment done for IR Improvement and finally Re-fitting of Incomer, OG – 1, OG – 2 & Spare Panel.
Making anty corrosive painting of Panel inside & Bus Chamber by the sythetic anamale paint as per direction of EIC
Supply delivery of Three phase Potential Transformer supply Ratio: 11 KV/√3 / 110 V/√3, VA: 100, Class: 0.5 BIL: 12 / 28 / 75 kVp, HSV: 12 KV VF: 1.2 times continuous and 1.9 for 8 hours Make: Suitable for Siemens make VCB
Supply delivery at site of Bakelite Sheet for PT as per sample
Charges for Disconnection of defective PT from circuit, Dismantling the PT, Cleaning of rusted portion inside Panel, new PT Installation, Secondary cable connection, Testing, Power Circuit & Control Circuit Checking & Power Charging
Supply delivery of 200 Watt Space Heater supply Make: RECO, 230 V
Supply delivery of Thermostat Range: 30⁰ C - 110⁰ C, 15 Amp., 230 / 250 V AC Make: ELCON GOLD, Model: MM-106,
Supply delivery of 2.5 sq. mm. , 1.1 kV grade copper Control controll cable for 4 Nos. Space Heater along with 2 No. Thermostat connection wiring charges for each Panel as per direction of E.I.C
Supply delivery of 2.5 sq. mm. , 1.1 kV grade copper Control controll cable for 3 Nos. Space Heater along with 1 No. Thermostat connection wiring charges for Bus-Bar Section as per direction of E.I.C
Charges for all Bus-Bars Dismantling, Rubbing, Sulfation Cleaning, Heating by applying CRC, WD-40, for IR Improvement and finally Re-fitting
Supply delivery replacement charges of Power Pack I/P: 110 / 230 V AC, O/P: 110 V DC Make: Approved make,
Supply delivery and charges of Silver Coating as per direction of EIC
Supply delivery & replacement charges of Vacuum Interrupter supply for Siemens make VCB
Charges for 11 KV VCB Racked out from panel,VCB mechanism dismantling, VI Housing dismantling& defective Vacuum Interrupter dismantling from VI Housing and New Vacuum Interrupter replacement& re-fitting the 11 KV VI housing, VCB mechanismand after re-fitting 11 KV VCB Racked in.
Closing Coil supply for 11 KV VCB, if required Coil Voltage: 110 V DC
Defective Closing Coil disconnecting from circuit & Dismantling from Panel and New Closing Coil replacement& re-connection charges
Tripping Coil supply for 11 KV VCB, if required Coil Voltage: 110 V DC
Defective Tripping Coil disconnecting from circuit & Dismantling from Panel and New Tripping Coil replacement& re-connection charges
Supply delivery & replacement charges of Multi Function Meter supply, if required Make: Schneide
Supply delivery & replacement charges of Aux. Relay supply, if required Make: GE T&D, Model: VAA33
calibration charges & replacemen re-connection of defective Aux. Relay disconnecting from circuit & Dismantling from Panel and New Aux. Relayt,
Supply delivery & replacement charges of Tripping Relay if required Make: GE T&D, Model: VAJH
Defective Tripping Relay disconnecting from circuit & Dismantling from Panel and Tripping Relay replacement, re-connection & calibration charges.
Supply delivery & replacement charges of TNC Rating: 25 A if required Make: Kaycee,
500 KVA HT AVR (7 – 12 KV / 11 KV) :
Supply delivery of PCB Relay Card supply for AVR as per exixting sample
Supply delivery of Voltage Controller Potentiometer (1K)
Supply delivery of Aux Contractor supply (2 NO – 2 NC) Coil Voltage: 220 V AC Make: Siemens / ABB,
Supply delivery of 1100 VA UPS Input: 230 V AC Make: APC,
Supply delivery of Elysian Blue Color Silica Gel dry and desiccant crystals type in the Breather of above transformer as per direction
Dehydration & Filtration of Transformer Oil by heat run process for improvement of IR Value (BDV minimum 60KV/mnt) by the hiring of Filtering Machine and Testing Machine & Kit etc as per I.E Rules.
Charges for Di-Electric Strength Test (BDV Test) by the hiring of Testing Machine & Kit etc as per I.E Rules.
Installtion charges above supplyed PCB card contractor in the AVR and replacement charges of UPS & Silica Gelas per direction of EIC
400 KVA Transformer:
Supply delivery of cast Allluminium boady 1/2 Kgs Elysian Blue Color Silica Gel dry and desiccant crystals type in the Breather of above transformer as per direction
Supply delivery of all kinds of Gaskets & Oil Seal supply for HT & LT Bushings, Top Cover, Inspection Cover, Valve etc. of 400 KVA, 11 KV / 0.433 KV Transforme
Charges for gasket changes for 400 KVA Transformer by disconnecting of all HT and LT terminals, draining transformer oil, opening of top cover, arresting of any oil leakage by changing of gasket and oil seal respectively various gasket portion like top cover, inspection cover, tap switch, conservator tank, radiators, buchholz, drain valve (as where required) and HT-LT bushing portion
Supply delivery and filling of Transformer Oil (minaral cooling Oil) as per IS-335-1993.
Dehydration & Filtration of Transformer Oil by heat run process for improvement of IR Value (BDV minimum 60KV/mnt) by the hiring of Filtering Machine as per direction of E.I.C (490 Ltrs. X 2 Nos. Transformer)
Charges for Di-Electric Strength Test (BDV Test) by the hiring of Testing Machine & Kit etc as per I.E Rules.
Painting of of the above Transformer by the ready mixed primer of approved make, and brand incl. preparation of surface by sand paper, cleaning etc. for receiving two coat of superior quality synthetic anamal paint after applying one coat of red lead chromate primer as per direction of EIC Painting wil be done by the spray paiting machine
Add: 18% GST
Add: 1% Cess
M S ENTERPRISE (BID ID -5885888)
WEST BENGAL ENGINEERING CO. (BID ID -5904200)
M/S.S.S.ENTERPRISE (BID ID -5887274)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .