| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹5.9 L+₹1.6 L (38.4%)Rejected-AOC | L2 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 3 | L3₹6.4 L+₹2.1 L (48.6%)Rejected-AOC 262 1 NEAR MANAV CHOWK NEW GRAIN MARKET AMBALA CITY HARYANA HARYANA 134003 | AMBALA | HARYANA | 134003 | L3 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 4 | L4₹7.2 L+₹2.9 L (68.9%)Rejected-AOC | L4 | Rejected-AOC OTHER THAN LOWEST BIDDER |
Tender Value
₹6 L
EMD Value
₹12,000
Closing Date
30 Oct 2021, 6:00 pmClosed
S F AUGUSTINE IDSE EE
MES OFFICE GE KASAULI DISTT SOLAN HP
REPAIR REPLACEMENT OF EXTERNAL GI PIPE LINES VALVES TO PUMP MOTORS INCLUDING PANEL BOARDS CI PIPE LINE INCLUDING FITTING ACCESSORIES AND SUPPORTS FOR SPRING SUPPLY SYSTEMS AT MIL STN SOLAN
2021_MES_474487_2
GEK-53/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
SOLAN
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE KASAULI
₹12,000
Yes
15 Dec 2021
8 Oct 2021
6 Nov 2021
8 Oct 2021
30 Oct 2021
18 Oct 2021
Amount
Schedule 'A' Section - I
Excavation in trenches in hard dense soil n.exc 1.5 mtr wide & n.exc 1.5mtr in depth and n. exc. 10sqm on plan for laying pipe in trenches and getting out complete all as specified and directed by Engr-In-Charge.
Returning filling in trenches, spreading, levelling, watering and well ramming in layers n.exc 25cm in hard dense soil complete all as specified and directed by Engr-In-Charge.
Removing of surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above starting point complete all as specified and directed by Engr-In-Charge.
Taking out unserviceable/defective/damaged/blockage GI/MS pipe 15 mm bore steel water tubing,sorting out serviceable pipe fitting for reuse and cleaning the pipe including fitting and removing away all unserviceable pipe from site, complete all as specified and as directed by Engr-In-Charge. (Note: Exacavation and earhwork shall be measured and paid for separately.)
All as per serial item No. 4.00 here-in-before but of size 20mm bore -ditto-.
All as per serial item No. 4.00 here-in-before but of size 25 mm bore -ditto-.
All as per serial item No. 4.00 here-in-before but of size 40mm bore -ditto-.
All as per serial item No. 4.00 here-in-before but of size 50mm bore -ditto-.
All as per serial item No. 4.00 here-in-before but of size 80mm bore -ditto-.
All as per serial item No. 4.00 here-in-before but of size 100mm bore -ditto-.
All as per serial item No. 4.00 here-in-before but of size 150mm bore -ditto-.
S&F GI tubing medium grade, ISI Marked conforming to IS 1239 Part-I 2004, 15mm bore with and including all fittings such as bends , elbows,tees, short length , socket, union, check nuts, nipples and weldings etc. fixed and laid in trenches/floor/under culvert/road crossing etc including testing complete all as specified and as directed by Engr-In-Charge.
All as per serial item No. 12.00 here-in-before but of size 20mm bore -ditto-.
All as per serial item No. 12.00 here-in-before but of size 25mm bore -ditto-.
All as per serial item No. 12.00 here-in-before but of size 40mm bore -ditto-.
All as per serial item No. 12.00 here-in-before but of size 50mm bore -ditto-.
All as per serial item No. 12.00 here-in-before but of size 80mm bore -ditto-.
All as per serial item No. 12.00 here-in-before but of size 100mm bore -ditto-.
All as per serial item No. 12.00 here-in-before but of size 150mm bore -ditto-.
S&F in replacement of Bronze gate valve for 15mm bore pipe, with iron wheel head, screwed both ends for iron pipe and fixed, ISI marked conforming to IS 778: 1984, fixed as in repair complete all as specified and directed by Engr-In-Charge.
All as per serial item No. 20.00 here-in-before but of size 20mm bore -ditto-.
All as per serial item No. 20.00 here-in-before but of size 25mm bore -ditto-.
All as per serial item No. 20.00 here-in-before but of size 40mm bore -ditto-.
All as per serial item No. 20.00 here-in-before but of size 50mm bore -ditto-.
Taking out old unsv and Supplying, fixing and testing of cast iron Sluice valve PN1.6 as per IS-14846, body, dome, wedge-CI IS:210, rings-bronze IS:318, Spindal-SS IS:6603, Gland Paking greasy jute packing, fasteners-CS, Gasket- Natural rubber, nominal size DN-150 mm, both ends flanged in existing line, after removal of old unserviceable sluice valve without damaging to existing pipe line complete all as specified and directed by Engr-in-charge. Note : Suitable size flanges for existing pipe line, Joints and jointing materials shall be included under this item.
All as per serial item No. 25.00 here-in-before but nominal size DN-100 mm -ditto-.
All as per serial item No. 25.00 here-in-before but nominal size DN-80 mm -ditto-.
S&F Cast iron Non Return valve W/O by pass arangement , Swing type, of Size 100 mm bore, confirming to IS 5312, flanged ends with nuts bolts, washers complete including taking down of old one .
S&F Cast iron Non Return valve W/O by pass arangement , Swing type, of Size 150 mm bore, confirming to IS 5312, flanged ends with nuts bolts, washers complete including taking down of old one .
Construction of brick masonary pit of size 60 x 60 x 60cm internal size with MS sheet 3mm thick and angle iron frame of size 40x40x6mm duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer including locking arrangement, lifting handle and including excavation / earth work, PCC in foundation, brick work, plaster including demolition of existing pit complete all as specified and shown in drawing No. STD- 1258, sheet 1/1. (original date - 30.11.93 and revised date - 15.09.2000 ) Note : Drawing mentioned above has not been enclosed herewith, however the same can be seen in the office of GE Kasauli.
Construction of brick masonary pit of size 90 x 90 x 90 cm internal size with MS sheet 3mm thick and angle iron frame of size 40x40x6mm duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer including locking arrangement, lifting handle and including excavation / earth work, PCC in foundation, brick work, plaster including demolition of existing pit complete all as specified and shown in drawing No. STD- 1258, sheet 1/1 (original date - 30.11.93 and revised date - 15.09.2000 ) Note : Drawing mentioned above has not been enclosed herewith, however the same can be seen in the office of GE Kasauli.
Construction of brick masonary pit of size 120 x 120 x 120 cm internal size with MS sheet 3 mm thick and angle iron frame of size 40x40x6mm duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer including locking arrangement, lifting handle and including excavation / earth work, PCC in foundation, brick work, plaster including demolition of existing pit complete all as specified and shown in drawing No. STD- 1258, sheet 1/1 (original date - 30.11.93 and revised date - 15.09.2000 ) Note : Drawing mentioned above has not been enclosed herewith, however the same can be seen in the office of GE Kasauli.
Taking Down old UNSV Dozing system deposited to water supply store and Supply, installation testing and commissioning of Dosing System along with injector, Square and Max output (flow rate) 12 cm Ltr/Hr of the following specification with complete accessories like lead tubing ,connecting ferrules,check valves etc all as specified and as directed by Engr-in-Charge. Specification :- 1. Preparation Tank model No VST-1005 of net cap 170 Ltrs of FRP dosing tank 650 mm x net height 375 mm + conical 300 mm gross height with stand 100 mm consisting of (a) Water Inlet line (b) Outlet with Y Strainer (c) Drain (d) Over flow (e) Conical bottom for sludge deposition (f) Pot hole with cover (g) Level gauge (h) Agitator 120 W, 900 RPM, 1 phase flange mounted motor with plastic shaft and impeller. 2. Service tank Model No VST -1006 of net cap 100 lts of FRP dosing tank top dia 540 mm x bottom dia 480 mm x height 575 mm consisting of :- (a) Water inlet line (b) Outlets with Y Stainer (c) Drain (d) Over flow (e) Level Gauge (f) Agitator 120 W, 900 RPM, 1 phase flange mounted motor with plastic shaft and impeller, (g) Inspection Report (h) Provision of mounting pump on lid/wall.
Supply of calcium hypo chloride, 65%-70% chlorine content, high strength granular disinfectant for treatment of drinking water complete all as specified and qty as per requirement and as directed by Engr-in-Charge.
Amount of credit of Rs. 42160.00 for retrived old material as mentioned in Schedule 'A' section-II of tender document in pdf form, will be deducted offline while acceptence of tender.
R. P. Suppliers and Construction Co.
ALPHA ENGINEERS AND BUILDERS
Vasudeva Trading Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .