Col Shery Goel, CWE Bikaner
HQ CWE Bikaner, Bikaner Mil Stn
Repair/replacement of Junction box, Timer Panel, UG cable, electric wiring and connected building, electrical work to temp building and allied works at Bikaner Mil Stn under GE (N) Bikaner
2023_MES_631603_1
CA No CWE BKN-Token No. 53/2023-2024
Open Tender
Civil Works
Item Rate
270 days
GE N BIKANER
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
Yes
GE (N) Bikaner
₹1.6 L
Yes
15 Feb 2024
7 Dec 2023
15 Jan 2024
7 Dec 2023
8 Jan 2024
1 Jan 2024
7 Dec 2023 - 16 Dec 2023
Amount
Demolition of cement concrete (unreinforced) in ground floor and pavings not exc 15 cm thick (below or above ground level) including floor tiles of any description complete all as specified & as directed.
Excavating in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exceeding 10 Sqm on plan & not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed.
Removing excavated soil/material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and as directed.
M&L for PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate as in foundations, filling and mass concrete, stay and copping of pole above ground level including finishing to exposed concrete surfaces even and fair and provision of formwork for rough finished surfaces complete all as specified and as directed.
Taking down carefully existing unserviceable/perished surface conduit/concealed conduit/ batten/casing caping aluminium/copper point wiring any type for light, fan, bell, socket, power point etc complete including all fixtures and fittings such as batten/conduit/casing caping, switches, sockets, ceiling rose, pendent holder, lamp holders, bracket holders, light fittings, top sheet covers, fan regulators, wooden boxes, MS sunken boxes, etc and making good the disturbed surfaces of wall, floors, ceiling, etc to match with the adjoining surfaces, complete all as specified and as directed.
M&L for point wiring for one light/fan/bell/buzzer point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non-metallic rigid PVC concealed conduit (medium duty, ISI marked, not less than 20mm dia) with all fittings such as tee, bends, etc all as per IS, terminated in & including new sunk type pressed steel terminal boxes concealed in wall for mounting fittings like switches, sockets, regulators etc with and including 3mm thick phenolic laminated sheet top cover, complete all as specified and as directed. Note : Cost of cutting/leaving forming chases for conduits, sinking for boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
All as per serial item No. 7.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board with other switches complete all as specified and directed.
All as per serial item No. 7.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board complete all as specified and directed.
All as per serial item No. 7.00 here-in-before but for one light point controlled by two, two way switches complete all as specified and directed.
All as per serial item No. 7.00 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 2.5 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 2.5 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour complete all as specified and directed.
S&F switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts, ISI marked, complete all as specified and as directed.
S&F switch piano, flush type, single pole, one way, 15/16 Amp, 230 Volts, ISI marked, complete all as specified and as directed.
S&F switch piano, flush type, single pole, two way, 5/6 Amp, 230 Volts, ISI marked, complete all as specified and as directed.
S&F bell push, flush type, 5/6 Amp, 230 Volts, ISI marked, complete all as specified and as directed.
S&F socket outlet, 3 pin, 5/6 Amp, flush type, 230 Volts, ISI marked, complete all as specified and as directed.
S&F socket outlet, 2 in 1, 3 pin, 5 and 15 Amp, flush type, 230 Volts, ISI marked, complete all as specified and as directed.
S&F ceiling rose, PVC/Polycarbonate insulated body, 65mmx50mm with three terminals, ISI marked, complete all as specified and as directed.
S&F lamp holder, PVC/Polycarbonate insulated body with back plate suitable for conduit/casing caping fittings, ISI marked, complete all as specified and as directed.
S&F electronic fan regulator, flush type, stepped type with 5 step control, 230 Volts, 150 Watt, including making hole in sheet top cover and connecting up, ISI marked, complete all as specified and as directed.
Supply and fixing Bell ‘Ding Dong’ / ‘Multi Music’ Type, AC, 230 Volts, ISI marked, complete all as specified and as directed.
Taking down of serviceable and refixing after LED light fitting mirror type with high out put diffuser 2 feet, 10 Watt 240 Volt, 50 Hz AC, ISI Marked decorative type with driver holder and LED lamp, correlated colour temperature shall be minimum 6500 degree Kelvin, including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Taking down of serviceable and refixing after LED tube light fitting, 1x20 Watt, 230 Volts, basic all purpose surface and wall mounted LED batten type with driver & polycarbonate housing including tube rod and all accessories, prewired and connecting up with & including 3 core sheathed flexible copper cable 1.5 sqmm of suitable length upto light point/ceiling rose, complete all as specified and as directed.
S&F in replacement of LED mirror fitting 1x10 Watt, 6000 K, 2 feet, basic all purpose surface and wall mounted LED batten with powdered coated aluminium housing & integrated electronic driver & all accessories including connection with 2 core flexible copper cable 23/0.00076 from ceiling rose to fitting connection with following specification, complete all as specified and as directed :- (a) Lumen efficacy of system should be minimum 105 Lumen per watt. (b) Voltage operating range : 160 to 270 Volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max 10%. (f) IP rating : IP-20. (g) CRCA pre coated housing. (h) LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection device for 2.5 KV. (l) CRI : Minimum 80 Make: Havells/ Crompton/Philips/Bajaj
S&F in replacement of LED tube light fitting, 1x20 Watt, 230 Volts, basic all purpose surface and wall mounted LED batten type with driver & polycarbonate housing including tube rod and all accessories, prewired and connecting up with & including 3 core sheathed flexible copper cable 1.5 sqmm of suitable length upto light point/ceiling rose, complete all as specified and as directed. Make: Havells/ Crompton/Philips/Bajaj
S&F in replacement of bulk head energy efficient LED light fitting, 1x10 Watt, 230 Volts, surface mounted, comprising of high brightness LEDs, IP-65 protection, with & including all standard accessories, prewired and connecting up with & including 3 core sheathed flexible copper cable 1.5 sqmm of suitable length upto light point/ceiling rose, complete all as specified and as directed. Make: Havells/ Crompton/Philips/Bajaj
S&F in replacement of LED based street light, housing made up of LM6 pressure die cast aluminium alloy with aerodynamically designed for all weather conditions with excellent thermal management, toughned glass and high power LED's with seconday optics and IP-66 protection, sturdiness. The fixture should have a minimum system efficiency of more than 110/120 lumen/watt and a minimum system lumen output of not less than 7700 lumens and maximum system wattage 70 Watts. The fixture shall have a correlated colour temperature of al least 5700K and CRI minimum 70. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance ingress protection of IP66 (lamp and gear compartment and mechanical inpact resistance raiting of IK>=08. The fixture driver should have an operating voltage range of 140-270 V & potted type for humming free operation, driver should be withstand up to 440v for 8hrs, two surge proection, 4KV one on driver and one 10 KV external surge protection, PF>0.95 and THD<10% and have double phase protection. LED light fitting should be suitable for ambient temperature from (-) 10C to (+) 50 C. The fixture should comply with the parameters IEC 60598 and LED should comply to IEC 61000-3-2 ed. 3.2 per harmonics IEC 61347-2-3, 2006 in configuration with IEC 61347-1 ed 2.0,2007 for electrical safety LM 79 and for LED LM 80 test report needs to be submitted from the house NABL accreditation laboratory complete all as specified and directed. Make : CG Cat Part No. TRP-409-70-57-SL-GL-NSG or equivalent make of Philips/Wipro/Bajaj
S&F in replacement of LED based street light, housing made up of LM6 pressure die cast aluminium alloy with aerodynamically designed for all weather conditions with excellent thermal management, toughned glass and high power LED's with seconday optics and IP66 protection, sturdiness. The fixture should have a minimum system efficiency of more than 110/120 lumen/watt and a minimum system lumen output of not less than 2750 lumens and maximum system wattage 25 Watts. The fixture shall have a correlated colour temperature of al least 5700 K and CRI f minimum 70. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance ingress protection of IP66 (lamp and gear compartment and mechanical inpact resistance raiting of IK>=08. The fixture driver should have an operating voltage range of 140-270 V & potted type for humming free operation, driver should be withstand up to 440v for 8hrs, two surge proection, 4KV one on driver and one 10 KV external surge protection, PF>0.95 and THD<10% and have double phase protection. LED light fitting should be suitable for ambient temperature from (-) 10C to (+) 50 C. The fixture should comply with the parameters IEC 60598 and LED should comply to IEC 61000-3-2 ed. 3.2 per harmonics IEC 61347-2-3,2006 in configuration with IEC 61347-1 ed 2.0,2007 for electrical safety LM 79 and for LED LM 80 test report needs to be submitted from the house NABL accreditation laboratory complete all as specified and directed. Make : CG Cat Part No. LSTS-25-CDL-M or equivalent make of Philips/Wipro/Bajaj
S&F in replacement of LED based street light, housing made up of LM6 pressure die cast aluminium alloy with aerodynamically designed for all weather conditions with excellent thermal management, toughned glass and high power LED's with seconday optics and IP66 protection, sturdiness. The fixture should have a minimum system efficiency of more than 125/135 lumen/watt and a minimum system lumen output of not less than 22500 lumens and maximum system wattage 180 Watts. The fixture shall have a correlated colour temperature of al least 5700K and CRI f minimum 70. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance ingress protection of IP66 (lamp and gear compartment and mechanical inpact resistance raiting of IK>=08. The fixture driver should have an operating voltage range of 140-270 V & potted type for humming free operation, driver should be withstand up to 440v for 8hrs, two surge proection, 4KV one on driver and one 10 KV external surge protection, PF>0.95 and THD<10% and have double phase protection. LED light fitting should be suitable for ambient temperature from (-) 10C to (+) 50 C. The fixture should comply with the parameters IEC 60598 and LED should comply to IEC 61000-3-2 ed. 3.2 per harmonics IEC 61347-2-3,2006 in configuration with IEC 61347-1 ed 2.0,2007 for electrical safety LM 79 and for LED LM 80 test report needs to be submitted from the house NABL accreditation laboratory complete all as specified and directed. Make : CG Cat Part No. CRP-418-180-57-HL2-GL-HR-NSR or equivalent make of Philips/Wipro/Bajaj
S&F in replacement of LED based Flood light, housing made up of LM6 pressure die cast aluminium alloy with aerodynamically designed for all weather conditions with excellent thermal management, toughned glass and high power LED's with seconday optics and IP66 protection, sturdiness. The fixture should have a minimum system efficiency of more than 110/120 lumen/watt and a minimum system lumen output of not less than 22000 lumens and maximum system wattage 200 Watts. The fixture shall have a correlated colour temperature of al least 5700K and CRI f minimum 70. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance ingress protection of IP66 (lamp and gear compartment and mechanical inpact resistance raiting of IK>=08. The fixture driver should have an operating voltage range of 140-270 V & potted type for humming free operation, driver should be withstand up to 440v for 8hrs, two surge proection, 4KV one on driver and one 10 KV external surge protection, PF>0.95 and THD<10% and have double phase protection. LED light fitting should be suitable for ambient temperature from (-) 10C to (+) 50 C. The fixture should comply with the parameters IEC 60598 and LED should comply to IEC 61000-3-2 ed. 3.2 per harmonics IEC 61347-2-3,2006 in configuration with IEC 61347-1 ed 2.0,2007 for electrical safety LM 79 and for LED LM 80 test report needs to be submitted from the house NABL accreditation laboratory complete all as specified and directed. Make : CG Cat Part No. CFS-501-200-57-60D-SL-GL-NGG or equivalent make of Philips/Wipro
S&F in replacement of LED based Flood light fitting, housing made up of pressure die cast aluminum Alloy with effective thermal management, sturdiness . The fixture should have a minimum system efficacy of more than 110 lumen/Watt and a minimum system lumen output of not less than 8800 lumens and maximum system wattage 80 Watts. The fixture shall have a corelated color temperature of at least 5000K and a CRI of minimum 70 .The fixture shall be designed for a system life of 50,000 hours @70% lumen maintenance. Ingress Protection of IP66 (lamp and gear Compartment and Mechanical Impact Resistance Rating of IK >=05. The fixture driver should be withstand up to 440v for 8hrs, two surge proection not less than 5KV one on driver and one external surge protection, PF >0.95 and THD<20% .The fixture should comply with the parameters as per IS10322 and for EMI and LM 79 test reports .Including suitable size street light fitting bracket with suitable size clamps,nut bolts and washers as per site requirement complete all as specified as directed. Make : CG Cat Part No. LFL-80-CDL/60-M or equivalent make of Philips/Wipro/Bajaj
S&F in replacement of automatic street light switch using infrared sensor based Nature Switch, 25 KW equally distributed, 63 Amps, 3-Pole, Model - Swadeep-02 EC 25 Kw 3P for automatic switching of street lights based on LUX level of natural light. The sensor (Nature switch) along with suitable power contactor rating 63 Amps 3-Pole & 40 Amps 2-Pole, MCB SP 63 Amps -03 Nos and support terminals should be enclosed in pole/wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR grade SMC Junction box (Sintex make) confirming to IP-54. The contactor suitable to 3-Phase load of 25 kw, rating 63 Amps 3 Pole, MCB rating 63 Amps SP 03 Nos complete all as specified and directed. Make of Nature switch-Kakatiya Energy systems Pvt Ltd. Hyderbad/ Bajaj/Healer. Contactor : BCH/L&T/Schneider (as per IEC-60947-4-1/IS-13947-4-1), MCB : Hager/ Schneider/ Legrand/L&T, Circuit Wiring-Polycab/RR Cable /Finolex/Havells.
S&F in replacement of automatic street light switch using infrared sensor based Nature Switch, 08 KW equally distributed, 63 Amps,1-Pole, Model - Swadeep-02 EC 8 Kw 1 Pole for automatic switching of street lights based on LUX level of natural light. The sensor (Nature switch) along with suitable power contactor rating 63 Amps 2-Pole & 40 Amps 2-Pole, MCB SP 63 Amps -02 Nos and support terminals should be enclosed in pole/wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR grade SMC Junction box (Sintex make) confirming to IP-54. The contactor suitable to 1-Phase load of 08 KW, rating 63 Amps 2 Pole, MCB rating 63 Amps SP 01 Nos complete all as specified and directed. Make of Nature switch-Kakatiya Energy systems Pvt Ltd. Hyderbad/ Bajaj/Healer. Contactor : BCH/L&T/Schneider (as per IEC-60947-4-1/IS-13947-4-1), MCB : Hager/ Schneider/ Legrand/L&T, Circuit Wiring-Polycab/RR Cable /Finolex/Havells.
Supply and fixing in replacement of 20 watts, LED Post Top Lantern, ideal to lit up parks, garden ways and heritage sites, fixed on post, complete all as specified & as directed. Make : CG Model LPTH-20-CDL or equivalent make : Philips /Bajaj/Wipro
Supply and fixing in replacement of LED decorative Post Top Lantern light fitting for 360 degree, indirect light with IP65 protection, resistant to impact and corrosion, glare free and better uniformity complete all as specified & as directed. Make : CG Model LPTO-40-CDL or equivalent make : Philips /Bajaj/Wipro
Supply and fixing in replacement of LED strip with driver capacity of 28 Watt for 5 mtr length having system voltage 220-240V 50 Hz, color temperature 6500 K, dimension of 5000x8x2mm complete all as specified and directed.
NOTES FOR LED LIGHT FITTINGS : (i) All LED light/luminare shall meet the provision laid down in IS - 16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part -II / Section 13. (ii) Contractor shall submit test report of LED street light fitting from Government accredited test laboratory for LM-79 and LM-80. (iii) Contractor has to furnish a replacement warranty of 02 years for LED light fittings complete including lamps from the date of completion of contract. The product will be replaced on site free of cost in the following case :- (a) Manufacturing defects. (b) Failure due to mechanical and electrical impact. (c) Drop in lumen (or lux at 1 m) below 90% of claimed values of lumen (or lux at 1 m) of the LED /Luminaries.
Supply and fixing in replacement of mounting bracket (suitable for fixing/holding street/ security light fittings) made of 40mm bore GI pipe ‘light grade’ not less than 1.50m long, bent to shape at required angle, fixed to Pole/wall with & including mild steel clamps (02 Nos) made out of flat iron 50x6mm with nuts, bolts & washers, matching with section of Pole/suitable for wall, complete all as specified and as directed.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 10 Amp, 230 Volt, 10 kA, ‘C’ Curve, fixed in repairs, complete all as specified and as directed.
S&F sheet metal enclosure for distribution boards flushed in wall, double door type, 415 Volts with 200 Amps rated bus bar, load line MCCB DB fitted with bus bar neutral links blank plates, TPN, vertical load line, 4 way complete all as specified and as directed including taking down old existing unserviceable DB with fixtures of any type & capacity :- Note : Cost of cutting/leaving forming chases for sinking for DB and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
S&F sheet metal enclosure for distribution boards flushed in wall, double door type, 415 Volts with 200 Amps rated bus bar, load line DB fitted with bus bar neutral links blank plates, SPN, 12 way, including taking down old existing unserviceable DB with fixtures of any type & capacity complete all as specified and as directed. Note : Cost of cutting/leaving forming chases for sinking for DB and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
S&F sheet metal enclosure for distribution boards flushed in wall, double door type, 415 Volts with 200 Amps rated bus bar, load line DB fitted with bus bar neutral links blank plates, SPN, 8 way, including taking down old existing unserviceable DB with fixtures of any type & capacity complete all as specified and as directed. Note : Cost of cutting/leaving forming chases for sinking for DB and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
S&F sheet metal enclosure for distribution boards flushed in wall, double door type, 415 Volts with 200 Amps rated bus bar, load line DB fitted with bus bar neutral links blank plates, SPN, 4 way, including taking down old existing unserviceable DB with fixtures of any type & capacity complete all as specified and as directed. Note : Cost of cutting/leaving forming chases for sinking for DB and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
S&F MCB, 6 to 32 Amps, Single Pole, 240 Volts, rupturing capacity 10 kA, ‘C’ Curve, with over load and short circuit protection, fixed in repairs, complete all as specified and as directed.
S&F MCB, 6 to 32 Amps, SPN, 240 Volts, rupturing capacity 10 kA, ‘C’ Curve, with over load and short circuit protection, fixed in repairs, complete all as specified and as directed.
S&F MCB, 63 Amps, TPN, 415 Volts, rupturing capacity 10 kA, ‘C’ Curve, with over load and short circuit protection, fixed in repairs, complete all as specified and as directed.
S&F MCCB 4 Pole 40 Amps, thermal magnetic having, breaking capacity 16 KA, 415 Volt & making connections with 25x3 mm copper strip as required from main bus bars, making necessary welding work including disconnecting & taking down old unserviceable MCCB complete all as specified and directed.
S&F MCCB 4 Pole 63 Amps, thermal magnetic having, breaking capacity 16 KA, 415 Volt & making connections with 25x3 mm copper strip as required from main bus bars, making necessary welding work including disconnecting & taking down old unserviceable MCCB complete all as specified and directed.
S&F MCCB 4 Pole 100 Amps, thermal magnetic having, breaking capacity 16 KA, 415 Volt & making connections with 25x3 mm copper strip as required from main bus bars, making necessary welding work including disconnecting & taking down old unserviceable MCCB complete all as specified and directed.
S&F MCCB 4 Pole 125 Amps, thermal magnetic having, breaking capacity 16 KA, 415 Volt & making connections with 25x3 mm copper strip as required from main bus bars, making necessary welding work including disconnecting & taking down old unserviceable MCCB complete all as specified and directed.
S&F MCCB 4 Pole 200 Amps, thermal magnetic having, breaking capacity 16 KA, 415 Volt & making connections with 25x3 mm copper strip as required from main bus bars, making necessary welding work including disconnecting & taking down old unserviceable MCCB complete all as specified and directed.
S&F MCCB 4 Pole 250 Amps, thermal magnetic having, breaking capacity 16 KA, 415 Volt & making connections with 25x3 mm copper strip as required from main bus bars, making necessary welding work including disconnecting & taking down old unserviceable MCCB complete all as specified and directed.
S&F MCCB 3 Pole 63 Amps, thermal magnetic having, breaking capacity 16 KA, 415 Volt & making connections with 25x3 mm copper strip as required from main bus bars, making necessary welding work including disconnecting & taking down old unserviceable MCCB complete all as specified and directed.
S&F MCCB 3 Pole 100 Amps, thermal magnetic having, breaking capacity 16 KA, 415 Volt & making connections with 25x3 mm copper strip as required from main bus bars, making necessary welding work including disconnecting & taking down old unserviceable MCCB complete all as specified and directed.
M&L for carefully disconnecting electric & water connections and taking down existing serviceable Geyser (water storage type) of capacity 25 litre vertical type and re-fixing the same with & including ‘Anchor’ type /fastener type bolts & nuts (Set of 4 bolts of suitable size but not less than 10mm dia 125mm long with nuts & washers) into the wall grouted properly to hold the geyser and making good the disturbed surface as original and re-connecting electric & water connections, complete all as directed.
Taking down fan, sealing cable end, dismantling blades and removing fan and blades & refixing ceiling fan of any make, any sweep, keeping side to store in safe custody for painting of ceiling fans complete, insitu with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. complete all as specified and directed.
Taking down exhaust fan, sealing cable end, dismantling blades and removing fan and blades & refixing exhaust fan of any make, any sweep, keeping side to store in safe custody for painting of exhaust fans complete, insitu with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 7.50 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40 mm thick RCC pit cover, etc including dismantling & taking out old existing unserviceable earthing complete all as specified & as directed. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
S&F in replacement of PVC insulated Copper Tailing Cable 6 core, 2.5 sqmm of suitable for installation on high mast light complete all as specified and directed.
M&L for 2.5 sqmm (nominal area) size main cable, three core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn into hollow street light pole, from fitting to distribution box or fitting to over head line etc including dismantling & taking down old unserviceable cable complete all as specified and directed.
M&L for 4 sqmm (nominal area) size main cable, two core, PVC insulated, unsheathed, aluminum conductor, 1100 Volts grade, ISI marked cables, drawn into hollow street light pole, from fitting to distribution box or fitting to over head line etc including dismantling & taking down old unserviceable cable complete all as specified and directed.
M&L for 6 sqmm (nominal area) size main cable, two core, PVC insulated, unsheathed, aluminum conductor, 1100 Volts grade, ISI marked cables, drawn into hollow street light pole, from fitting to distribution box or fitting to over head line etc including dismantling & taking down old unserviceable cable complete all as specified and directed.
M&L for 10 sqmm (nominal area) size main cable, two core, PVC insulated, unsheathed, aluminum conductor, 1100 Volts grade, ISI marked cables, drawn into hollow street light pole, from fitting to distribution box or fitting to over head line etc including dismantling & taking down old unserviceable cable complete all as specified and directed.
M&L for sub main wiring with two runs of 4 sqmm (nominal area) size main cable & one run of 4 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through existing PVC conduit ISI marked including fittings/accessories, fixed in wall/ ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified and directed. Notes :- (i) 02 runs of 4 sqmm size main cable, 01 run of 4 sqmm size earth continuity conductor cable shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
M&L for sub main wiring with two runs of 4 sqmm (nominal area) size main cable & one run of 4 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit ISI marked not less than 25mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified and directed. Notes :- (i) 02 runs of 4 sqmm size main cable, 01 run of 4 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 6 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through existing PVC conduit ISI marked including fittings/accessories, fixed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified and directed. Notes :- (i) 02 runs of 6 sqmm size main cable, 01 run of 6 sqmm size earth continuity conductor cable shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 6 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit ISI marked not less than 25mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified and directed. Notes :- (i) 02 runs of 6 sqmm size main cable, 01 run of 6 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 50 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed. Notes :- (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 35 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed. Notes :- (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 25 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed. Notes :- (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 25 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed. Notes :- (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 16 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed. Notes :- (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 16 sqmm 2 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed. Notes :- (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 10 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed. Notes :- (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
M&L for dry sand (Local Tibba sand) and punning for cushioning and cover for protection of under ground electric cable complete all as specified and as directed. Notes :-(i) Approved local Tibba dry sand free from vegetations, grass and other deleterious substances shall be used. (ii) For the purpose of payment, only punned thickness shall be measured.
M&L for sub class ‘B’ (old size) burnt clay bricks laid flat and dry abutting each other with gap between adjacent bricks not exc. 10mm for protection of underground electric cable in such a way that the length of brick is at right angle to the central axis of cable complete all as specified and as directed.
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm confirming to IS -5820 complete all as specified and as directed.
M&L for Boring of holes of 80mm bore under road, pavement, hard standing, (minimum 1.0m below the road surface) etc by trench less technology using necessary machine / manually without disturbing the top surface suitable for passing the GI protection pipe / cables, complete all as specified and as directed. Note :- GI pipe laid shall be measured & paid for separately under appropriate item of this Schedule.
M&L for galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches/ under road/ drains, fixed to poles/ walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete including taking down old unserviceable pipe with clamps complete all as specified and directed. Note :- Excavation & earthwork shall be measured & paid for separately.
S&F cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections conforming to Grade E-165 (Fe 290) including nuts, bolts, washers, welding, bending cold or hot, drilled holes for bolts, in any shape or size for 33 KV/ 11 KV over head structure with & including two coats of aluminium paint over a coat of red oxide zinc chrome primer, fixed including taking down old unserviceable cross arms, complete all as specified & as directed. Notes :- (i) Size, section and shape of steel sections shall be as directed. (ii) Weight of paint shall not be considered for payment purpose and quoted rate shall deemed to be included this aspect.
Taking down existing high mast head frame and dismantling for repairing of unserviceable parts including repair of complete control panel wiring and fixing the same position after repair including testing complete all as specified and directed. Note : Making suitable arrangements of ladder or crane or scaffolding is the responsibility of contractor.
Taking down existing high mast pole and dismantling pole of hight 12 to 21 Mtrs from bottom plate, nuts and bolts complete with the help of suitable T&P required for holding, lifting and dismantling high mast pole, replacement of unserviceable part, oiling and greasing of pulleys, gear box, rope and all moving parts including assembling, intallation of high mast pole complete all as specified and directed by Engineer in Charge. Note. (i) Cost of crane for dismantling high mast pole is deemed to be included in quoted rate. (ii) Cost of oiling and greasing of moving parts in deemed to be included in rate quoted.
Taking down by disconncting the existing electrical connections of winch motor for rewinding / repairs including rewinding the motor of capacity upto 2 HP with best class super enameled copper conductor of existing gause and size including winding with fibre cloth/PVC insulated winding paper, superior quality varnishig, insulating 230 Volts AC, 50 Hz electric supply system and refixing and reconnecting the same location for satisfactory functioning of winch on 230 Volts electric supply system complete all as specified and directed.
Taking down the existing winch gear box of high mast light 12 to 21 mtrs by disconnecting the winch motor and supply and fixing in replacement the winch gear box of appropriate capacity as per sample and make at site, fixing and connecting the same with winch motor for satisfactory operation of winch on electrical power complete all as specified and directed.
Supply and fixing in replacement of galvanized steel wire rope conforming to IS-2266-2002 of nominal diameter of 10mm having 6x19 multi stranded construction steel core CRW grade 1570, having mass 46.1 Kg/100 RM with minimum breaking force of 63 KN suitable including greasing complete all as specified and as directed including taking down old unserviceable steel rope. Make : Usha / Bombay Foot / National or as used/recommended by OEM. Notes : (i) The steel rope shall be best performed plough straight non rotating type conforming to IS-2266. (ii) The breaking strength of the rope shall not be less than 6 time the safe working load thereon. (iii) Test Certificate of manufacturer shall be submitted by the contractor.
Supply and fixing in replacement surge protection devices 5 KV compatible with industrial and outdoor LED fixtures upto rated power of 75 Watt complete all as specified and directed. Make –Make –CG /Philps/Wipro
Supply and fixing in replacement surge protection devices 5 KV compatible with industrial and outdoor LED fixtures with rated power above 75 Watt to 150 Watt complete all as specified and directed. Make –Make –CG /Philps/Wipro
Taking down carefully the defective street light fittings any kind any type from the poles/walls and refixing the same on poles/walls after repair of street light complete all as specified and directed by Engineer in Charge. (Note : A Team of workers for emergency are available inside the camp for 24 Hours) (i) T&P i.e, ladder and vehicle will provided by the contractor. (ii) The contractor/his rep will collect the complaint from JE E/M every day 9.00 Hours, the same will be rectified before sunset on same day, If the contractor fail to rectify the defects mentioned in the complaint slip on same day, he will be charged Rs. 100 per complaint and same will be recovered from due payment from contractor claim. NOTE:- VMTL with driver will be provided by the AGE E/M GE (N) Bikaner for repair of double steel tubular swan neck pole's and single swan neck poles security lights only.
Supply and fixing in replacement outdoor Driver unit 25 watt with surge protection complete all as specified and directed. Make –CG /Philps/Wipro
Supply and fixing in replacement outdoor Driver unit 40 watt with surge protection complete all as specified and directed. Make –Make –CG /Philps/Wipro
Supply and fixing in replacement outdoor Driver unit 45 watt with surge protection complete all as specified and directed. Make –Make –CG /Philps/Wipro
Supply and fixing in replacement outdoor Driver unit 75 watt with surge protection complete all as specified and directed. Make –Make –CG /Philps/Wipro
Supply and fixing in replacement outdoor Driver unit 90 watt with surge protection complete all as specified and directed. Make –Make –CG /Philps/Wipro
Supply and fixing in replacement outdoor Driver unit 150 watt with surge protection complete all as specified and directed. Make –Make –CG /Philps/Wipro
Tightening mounting bracket for holding street/security light fittings GI pipe, fixed to Pole with & including realigning to the centre of roads including replacement of necessary mild steel clamps (02 Nos) made out of flat iron 50x6mm with nuts, bolts & washers wherever required, matching with section of Pole/suitable for wall, complete all as specified and as directed.
Cutting/trimming/pruning of tree branches around the around street light fitting and making the street light free from touching the tree branches not less the 4 mtr radius and removing the same from site and depositing at places within the cantt area complete all as specified and directed.
S&F in replacement of Junction Box of size (HxWxD) 300x200x105mm made out of Polycarbonate material totally enclosed, dust and vermin proof, rain protected slanted roof top, door pasted with rubber gasket, water tight IP 66 with integrated membranes/ metric knockouts for cable entry with cable glands, protection and suitable size of "connectwell" stud teriminal (provision for socket bolting) - 04 Nos suitable for 415 volts, 50 Hz, 3 Phase 4 wire internal wiring system including MCB SP 06 Amps - 01 No and mounted on tubular/PCC pole with suitable clamps, nuts, bolts complete all as specified and directed. Note :- CA No. shall be embossed on each box by digital printing mechanism.
Testing and checking of faulty street light feeder including under ground cable or on the pole, on line etc and repair the same after remove the faulty feeder and complete testing complete all as specified and directed. Note:- Earth work shall be measured and paid for separately.
Taking down old unserviceable time switch, checking /testing time switch by disconnecting the connection and re-fixing the same after minor repair/resetting complete all as specified and directed. Note:- item required for repairing of timer switch will measured and paid seperately under appropriate schedule of item.
Supply only Panel mounted 2 Pole contactor MNX-22-2 Pole of suitable rating operational voltage 230 volts confirming to IS/IEC60947-4-1, AC 50 Hz, inbuilt aux. contacts-1 No+01 NC with standard coil voltage 220 volts the surge resistor contract shall be post break type and damping resistances after closing be cut of current rating capacity 22 Amps complete all as specified and directed. Make : L&T/C&S/Havells
Supply only Panel mounted 2 Pole contactor MNX-40-2 Pole of suitable rating operational voltage 230 volts confirming to IS/IEC60947-4-1, AC 50 Hz, inbuilt aux. contacts-1 No+01 NC with standard coil voltage 220 volts the surge resistor contract shall be post break type and damping resistances after closing be cut of current rating capacity 22 Amps complete all as specified and directed. Make : L&T/C&S/Havells.
Supply only nature switch designed for automatic control of outdoor lighting, using infrared sensing based nature switches compatible for both single & three phases supply with operating voltage range 120-440 Volts for a nominal 230 Volts system complete all as specified and directed.
M&L for repairing of MS street light junction box, tighting of loose nut, bolts, screws etc including cutting of burnt thimbles/ LT cable, taking out LT cable from loop and reconnecting to bus bar with new thimbles duly crimpped with cable complete all as specified and directed.
LED Panel 36 watt with 2ft x 2 ft slim panel 595X595mm with super bright recessed mounting LED Slim ceiling light with white powder coated extruded aluminium housing and highly efficient light smoothing optics to deliver superior illumination including LED driver and fixing in recess ceiling suitable size of aluminium strip size as required for fixing of LED fitting complete with all accessories prewired fixed on ceiling and connecting up complete with 3 core flexible cable of size 23/0.0076 including taking down old unserviceable fittings complete all as specified and directed.
M/s Rohit Construction Co.
SUBHAM ENTERPRISES
B K CONTRACTORS
M/s Kamal Builders
M/s Kataria Construction Company
M/s MAKHAN ENTERPRISES
Aman Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .