Tender Value
Refer Docs
EMD Value
₹6,000
Closing Date
22 Feb 2022, 4:00 pmClosed
Executive Engineer
Electric Division JPDCL Udhampur
Creation of 25kva substation alongwith HT and LT Line
2022_PDD_159859_1
ED/UDH/68 of 2021-22 dt. 08-02-2022
Open Tender
Electrical Works
Turn-key
45 days
At Govt. Fruit Plant Nursery Badolla in Udhampur
Please refer Tender documents.
2 documents required · 2 mandatory
₹200
Executive Engineer, Electric Division JPDCL
₹6,000
26 Feb 2022
9 Feb 2022
24 Feb 2022
9 Feb 2022
22 Feb 2022
9 Feb 2022
9 Feb 2022 - 15 Feb 2022
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Creation of 25 KVA Sub Station at Govt. Fruit Plant Nursery, Badolla in District Udhampur.
11/0.433kV, 3-phase 25 KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate
Gapless surge arrestor 9KV, 10KA, LA with polymer housing station type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
70 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Alumnium Stranded Conductor FRLS type
9 mtr. Long ST Pole (ST-410 SP33)
11kV Polymeric composite Disc Insulator 12kV, min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with tension fitting
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
LT distribution box for 25 KVA DTR with MCCB for incomer and SfU's for outgoing circuits.
Cement bottoming of ST poles in 1:2:4 mix as per REC standards
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239. GI Strip for neutral earthing of size 50 mm x 6 mm & 32mm x 3mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Painting of Substation ST Poles/cross arms/clamps with one coat of Red oxide and two coats of aluminium paint
Danger Plates with Clamps
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for erection of LT line on 8 mtr long PCC poles at Govt. Nursery Fruit Plant Badolla in District Udhampur.
8 mtr. Long PCC (WL-200kg)
GI U-Clamp for shackle insulator
0.03 ACSR Conductor Weasel.
Shackle Insulators
Galvinized Nuts and Bolts.
Cement bottoming of ST poles in 1:2:4 mix as per REC standards
Anti- Climbing Device with Clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 32X3 mm for LT
LT line spacers
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Jeet Kumar
udhay partap singh
DINESH KUMAR KHAJURIA
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .