Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹31.1 LAccepted-AOC | 1st | Accepted-AOC 1st lowest | |
| 2 | 2nd₹31.5 L+₹17,468 (0.56%)Rejected-Finance | 2nd | Rejected-Finance 2nd lowest | |
| 3 | 3rd₹31.8 L+₹46,893 (1.50%)Rejected-Finance NINGTHOUKHONG WARD NO 05 BISHNUPUR MANIPUR 795126 | BISHNUPUR | BISHNUPUR | MANIPUR | 795126 | 3rd | Rejected-Finance 3rd lowest | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical EMD/Fee not received |
Tender Value
₹29.5 L
EMD Value
₹59,000
Closing Date
30 Dec 2019, 4:00 pmClosed
Sr. Manager (E), Contract Department
Office of the Sr. Manager (E), Contract Department, NHPC Ltd., Loktak Power Station, Komkeirap, Manipur-795124
Repairing and Maintenance of Water tanks of Old Colony and new Colony near Guest house at Loktak
2019_NHPC_525595_1
CD/LOK/4(189)/2019/1934
Open Tender
Civil Works
Works
120 days
NHPC NHPC Loktak Power Station
Please refer Tender documents.
6 documents required · 6 mandatory
₹560
Yes
NHPC Ltd.,
₹59,000
Yes
8 Feb 2020
9 Dec 2019
3 Jan 2020
9 Dec 2019
30 Dec 2019
9 Dec 2019
Amount
Dismantling sheet roofing including ridges, hips, valleys, gutters etc. stacking the serviceable materials and disposal of unserviceable materials within 50 m lead. G.I. sheet roofing.
Demolition of stone masonry below G.L. upto 1m depth including stacking of serviceable materials and disposal of unserviceable materials within 50 m lead. Rubble masonry in cement mortar.
Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms lift upto 1.5 metres including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres 1.10.2 Hard/Dense soil.
Providing and laying cement concrete in foundation and plinth excluding the cost of centering and shuttering in (2.1.3) 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
Steel Reinforcement for R.C.C work including straightening, cutting, bending and placing in position and binding all complete. b) Thermo-Mechanically treated bar.
Providing form work i/c centering and shuttering so as to give a rough finish strutting and propping etc. Height of propping and centering below supporting floor to ceiling not exceeding 4 m and removal of the same for in situ reinforced concrete and plain concrete work in (4.1.2) Flat surface such as suspended floor , roofs landings and the like.
RCC work in walls (any thickness), including attached pillasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, post and struts upto floor five level excluding the cost of centering-shuttering, finishing and reinforcement (3.2.2.) 1:1.5:3 (1cement:1.5 coarse sand:3graded stone aggregate20 mm nominal size)
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08% and conforming to I.S. 15622, of approved make, in all colours & shade, in laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete size of tile 300x300 mm (single charged) Branded
Providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08% and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12mm thick bed of cement mortar 1:3 (1cement :3 coarse sand) including grouting the joint with cement & matching pigments etc. complete. 9.32.3) Size of tile 300x300 mm (single charged) Branded.
Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a coat of approved steel primer red oxide zinc chrome primer conforming to IS:2074-1979) welded and bolted including special shape washer etc. complete. 10.61.1 Electric resistant welded tube (Conforming to IS:1611-1979)
Trapezoidal Pre-painted Profile Sheet roofing of approved brand DYNA Roof or equivalent with selt drilling screws of 68 mm long Xylon coated screws with PVC washer & caps complete, excluding the coat of purlins & trusses.10.63.2 ii) 0.40mm/ 3.2kg/ sqm.
Trapezoidal Pre-painted Profile Sheet for Ridges Gutter or Valley 610 mm wide of approved brand DYNA Roof or equivalent fixed with selt drilling screws of 68 mm long Xylon coated screws with PVC washer & caps completed, excluding the coat of purlins rafter & trusses.10.64.2 ii) 0.40mm/3.2kg/ sqm.
Providing wood work in trusses, purlins, rafter, posts, post plate wall plate & the like wrought framed hoisted & fixed in position. Leihao wood.
Supplying and fixing welded steel wire fabric to wood or steel members in partition etc. b) Weight exceeding 3 kg/sqm but not exceeding 4 kg/sqm
2nd class (local first class) brick work in foundation and plinth in cement mortar 1:4 (1 cement: 4 coarse sand)
12 mm cement plaster 1:4 (1 cement: 4 fine sand)
Finishing walls weather shield paint of approved quality on new work (three or more coats) tom given shade.
Painting (two or more coats excluding priming coat) with superior ready mixed paint for steel work of approved quality in all shades on new steel work to give an even shade.
Add EPF 0.65%
Add CESS 1%
Add GST @ 18% GST
TH RAKHESH SINGH
M/S L JAYANTAKUMAR SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .