Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹12.5 L+₹54,810 (4.60%)Rejected-Finance MALANCHA ROAD KHARAGPUR 721304 DIST WEST MIDNAPORE WEST BENGAL | KHARAGPUR | WEST MIDNAPORE | WEST BENGAL | 721304 | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹14.2 L+₹2.3 L (19.4%)Rejected-Finance GATE NO 1 RAKHAIJUNGLE KHARAGPUR DISTT PASCHIM MIDNIPUR WEST BENGAL PIN 721303 | KHARAGPUR | PASCHIM MIDNIPUR | WEST BENGAL | 721303 | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹14.9 L+₹3.0 L (25.4%)Rejected-Finance 197 4 KANTADANGA ROAD P O FINGAPARA KANKINARA NORTH 24 PARGANAS PIN 743129 | KANKINARA | NORTH 24 PARGANAS | WEST BENGAL | 743129 | L4 | Rejected-Finance NOT BEING L1 | |
| 5 | L5₹15.5 L+₹3.6 L (30.3%)Rejected-Finance | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
14 Feb 2023, 6:00 pmClosed
GE (AF) Kalaikunda
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore St West Bengal Pin 721303
REPAIR TO ROOF/ROOF TREATMENT, CHAJJA, FESCIA AND PARPET WALL AT AIR FORCE STATION KALAIKUNDA UNDER GE (AF) KALAIKUNDA
2023_MES_573583_1
C/8816/E8
Open Tender
Civil Works
Item Rate
180 days
AF STN KALAIKUNDA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF KALAIKUNDA
₹30,000
Yes
15 Mar 2023
7 Jan 2023
15 Feb 2023
7 Jan 2023
14 Feb 2023
23 Jan 2023
Amount
Demolition of cement concrete of any description and in any position not otherwise specifically provided for including taking out of old damaged unserviceable tarfelt or membrane of any description and removing of debris from premises and cleaning roof surfaces by brushing etc and washing down with water and removing dirt, dust etc complete to receive roof treatment all as specified and as directed.
Demolation of cement concret(reinforced) Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work and removing of debris from premises complete all as specified and as directed.
Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand (1:1), by weight complete all as specified and as directed.
M&L for 40 mm thick (Average) cement concrete type B-I, 1:2:4 using 20 mmgraded aggregate with WPC as per manufacturer,s instruction as in roof padding in order to maintain proper slope and camber finished the surface even and smooth with and including brushing in two layers using water proofing layer of damp proof ultra of make Asain or any other similar material of any approved make (Fosroc/Sika/BASAF) to give a layer of not less than 1.50 mm thick on newly concrete surface complete all as specified and as directed.
Materials and Labour for waterproofing treatment to existing RCC roof in the following steps complete all as specified and directed. (i) Complete removal of the existing water proofing treatment including padding (buid in cm/concrete) and removing of debris from premises and cleaning roof surfaces by brushing etc and washing down with water and removing dirt, dust etc complete (ii) Wire brushing and cleaning top surface of tiles, lime terracing or cement concrete, including flashings and junction of parapets, etc., and surface painting, with a layer of blown grade bitumen of any penetration applied hot @ 1.7 kg per sq. m, blinded with grit or pea size gravel @ 0.006 cu.m per sq.m, and lightly tampered (area of flashings, etc., shall be added to the roof area) (iiii) Supply and Laying, chicken wire mesh of size 12.5 mm x 0.51 mm (24 SWG) hexagonal construction including all laps, cutting and waste in fabric reinforcement to PCC roof padding including providing 40 mm thick plain cement concrete (1:2:4) type B0using 12.5 mm graded aggregates as in roof padding. (iv) Providing 15 mm thick screed bed or bedding layer of cement mortar (1:3), mixed with liquid water proofing compound as per manufactures instructions, on concrete surface of roofs or terracing and finishing surface even and smooth without using extra cement. (iv) Waterproofing treatment over smooth finished surfaces after application of cold applied bituminous primer @ 0.30 Kg /Sq M,, providing and laying APP polymer, modified, non-woven polyester fabric of 150 grams/square metre, reinforced membrane, 3.00 mm thick, weighing 3.50 Kg / Sq M, by torch on application method, with minimum 75 mm overlap on longitudinal direction and 100 mm overlap on the transverse direction or as per manufacturer,s instructions complete all as specified and directed. Make of APP Membrane : M/s STP Ltd./M/s Texsa India Ltd./M/s IWL India Ltd/Asain Ltd 3. APP membrane shall be laid and tested by the manufacturer deploying their own team under strict supervisionand Leak proof testing with ponding with water shall be done for 72 hours in presence of user representative and report shall be sumitted. Requisite guarantee certificate from manufacturer along with contractor’s certificate required to be furnished after successfully completion of testing. The submission of both certificate is mandatory before issue of completion certificate.
Materials and Labour for waterproofing treatment to existing RCC roof in the following steps complete all as specified and directed. (i) Complete removal of the existing water proofing treatment and removing of debris from premises and cleaning roof surfaces by brushing etc and washing down with water and removing dirt, dust etc complete (ii) Wire brushing and cleaning top surface of tiles, lime terracing or cement concrete, including flashings and junction of parapets, etc and Providing 15 mm thick screed bed or bedding layer of cement mortar (1:3), mixed with liquid water proofing compound as per manufactures instructions, on concrete surface of roofs or terracing and finishing surface even and smooth without using extra cement. (iii) Applying bituminous primer @ 0.40 ltrs per sqm over prepared surfaces of roof including parapet surfaces confirming to IS : 3384. (iv) One layer of APP based polymeric membranes of approved manufacturers, 3 mm thick, weight not less than 3.6 kg/sqm, reinforced with non woven polyester fabric (weight not less than 160 gms/sqm). Polymeric membrane shall be taken to cover the thickness of slab and shall be finished by a membrane flushing. Note: (i) Laying of APP based membranes shall be done by torch application or as per manufacturer's instructions. (ii) Side overlaps shall be minimum 75 mm and the end taps shall be minimum 100 mm and sealing of all overlaps & joints as per manufacturer instruction. (iii) For parapets, membranes shall be taken to a height of minimum 60 Cm and then inserted to the parapet in a groove. The same shall be finished by a membrane flashing. Make of APP Membrane : M/s STP Ltd./M/s Texsa India Ltd./M/s IWL India Ltd. 3. APP membrane shall be laid and tested by the manufacturer deploying their own team under strict supervisionand Leak proof testing with ponding with water shall be done for 72 hours in presence of user representative and report shall be sumitted. Requisite guarantee certificate from manufacturer along with contractor’s certificate required to be furnished after successfully completion of testing. The submission of both certificate is mandatory before issue of completion certificate.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and directed by Engineer- in-charge.
M&L for RCC type B0 1:2:4(using 12.5 mm graded aggregate) as in chajjas complete all as specified and as directed.
Use and waste of form works to sides and soffits of floor or roof beam,lintels, cantilevers, shelves including support, overhangs etc for rough finished surface of concrete complete all as specified and as directed.
Use and waste of form works to chajjas etc .for rough finished surfaces of concrete complete all as specified and as directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and as directed.
M&L for Brick work with fly ash bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 Complete all as specified and as directed.
Taking down SWR pipes (any size or pattern), including all fittings, 'T', bends,etc., including removal to store for taking credit (measured overall as fixed along the centre line over fittings and accessories), complete all as directed.
S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 110 mm dia, laid in trenches, wall and floor including all fitting complete all as specified and directed by Engineer- in- charge .
S & F UPVC bends with inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge
Taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as directed.
Materials and Labour for rendering 5mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 10mm thick backing coat in cement mortar (1:4) on fair faces of brick work or concrete surface in walls, complete all as specified and directed. Note: - (Water proofing compound will be measured and paid separately)
Supply only Liquid water proofing compound conforming to IS: 2645 - 1975 specification complete all as specified and as directed (Make : CICO No- 1/SIKA/ACCO PROOF).
M&L, rendering 5 mm thick in cement mortar 1: 3 on ceiling / soffits of chajjas etc finished even and smooth without using extra cement complete all as specified and directed.
M & L for preparation of newly plastered surfaces of ceiling and applying three coat of white wash on new surface complete all as specified and directed.
Material and Labour for applying two coats of cement-based paint, white or tinted to new plastered surfaces on walls including priming with alkali resistant priming paint and including preparation of surfaces complete all as specified and directed.
Taking up or down 15mm dia GI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
Taking up or down 20mm dia GI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
Refixing of old steel tubing and connection with new fittings ISI Marked in new or old position (wall, ceiling, floors, etc) of 15 mm bore all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Refixing of old steel tubing and connection with new fittings ISI Marked in new or old position (wall, ceiling, floors, etc) of 20 mm bore all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & fixing to walls , ceiling and laid in trenches 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & fixing to walls , ceiling and laid in trenches 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
M&L for disconnecting existing tank setting aside for repairs, cleaning of service PVC tank by rubbing vertical wall and bottom of with bleaching powder and allowed ½ hour to react and then washing down with water to get free from deposits and bleaching inside the tank of capacity and mouth of circulating pipes and hoisting, reconnecting and refixing in position capacity exc.300 and not exc. 500 ltrs complete all as specified & as directed.
M&L for disconnecting existing tank setting aside for repairs, cleaning of service PVC tank by rubbing vertical wall and bottom of with bleaching powder and allowed ½ hour to react and then washing down with water to get free from deposits and bleaching inside the tank of capacity and mouth of circulating pipes and hoisting, reconnecting and refixing in position capacity exc.500 and not exc. 1000 ltrs complete all as specified & as directed.
S&F 500 ltrs IS marked multilayer rotational moulded polythytene water storage tanks (cylindrical vertical with closed top) as per IS 12701: 1996hoisted and fixed in position with and including 20mm brass ball valves high pressure with polythene float and nut with and including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes including dismantling exsiting unserviceable one complete all as specified and directed .
S&F 1000 ltrs IS marked multilayer rotational moulded polythytene water storage tanks (cylindrical vertical with closed top) as per IS 12701: 1996 hoisted and fixed in position with and including 25mm brass ball valves high pressure with polythene float and nut with including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes including dincluding dismantling exsiting unserviceable one complete all as specified and directed .
S & F in repair 20 mm nominal size brass float valve, high pressure, with polythene float and flynut, screwed for iron pipe and fixed complete all as specified and as directed.
M&L mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire ( annealed) not less than 0.90 mm dia. or securing with clips complete all as specified and directed
S&F Mild steel TMT bar 6mm to 8mm dia cut to length, bent to shape reqd, incld cranking, bending spirally for hooping for columns , hooking ends & binding with & including mild steel wire ( annealed) not less than 0.90 mm dia. or securing with clips complete all as specified and directed
T K Construction
SUMAN CONSTRUCTION
MS R.K.ENTERPRISE
MS INDIRA ELECTRICS
Neha Enterprise
Dilip Enterprise
SHARMA ENTERPRISES
Kalpana Traders
Sai & Siva Enterprises
M/S C C CONSTRUCTION
M/S KANAN TRADERS
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .