Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9 CrAccepted-AOC 322 AGGARWAL MODERN BAZAR C 33 LAWRENCE ROADS DELHI 110035 | DELHI | NORTH WEST DELHI | DELHI | 110035 | ₹9 Cr Quoted ₹9.2 Cr | L1 | Accepted-AOC Accept |
| 2 | L2₹9.6 Cr+₹37.9 L (4.12%)Rejected-AOC A 14 INDUSTRIAL HOUSE INDERPURI NEW DELHI 1100012 | NEW DELHI | NEW DELHI | DELHI | 110012 | ₹9.6 Cr+₹37.9 L (4.12%) | L2 | Rejected-AOC Reject |
| 3 | L3₹9.7 Cr+₹53.4 L (5.79%)Rejected-AOC 143 INDUSTRIAL AREA PHASE 2 PANCHKULA HARYANA | PANCHKULA | PANCHKULA | HARYANA | ₹9.7 Cr+₹53.4 L (5.79%) | L3 | Rejected-AOC Reject |
| 4 | L4₹10.0 Cr+₹79.9 L (8.67%)Rejected-AOC 46 LOWER GROUND FLOOR CHARMWOOD PLAZA EROS GARDEN FARIDABAD HARYANA 121009 | FARIDABAD | FARIDABAD | HARYANA | 121009 | ₹10.0 Cr+₹79.9 L (8.67%) | L4 | Rejected-AOC Reject |
Tender Value
₹9.8 Cr
EMD Value
₹19.7 L
Closing Date
23 May 2023, 3:00 pmClosed
XEN-W/S MECH. DIVISION NARNAUL
Executive Engineer M/Garh W.S. Mech. Divn., Narnaul, 123001
Supply, Erection and Commissioning of new 10 Cs to 30 Cs VT Axial Flow Pumps and Motor with connected electric equipments at Pump Houses MD-1 to MD-6 of M/Garh Disty. in W.S Mech. Division Narnaul
2023_HRY_277539_1
1662-78/9-A dated 26/04/2023
Open Tender
Pumps/Motors
Works
240 days
XEN-W/S MECH. DIVISION NARNAUL
Please refer Tender documents.
3 documents required · 3 mandatory
₹20,000
₹19.7 L
Yes
XEN-W/S MECH. DIVISION NARNAUL
1 Sept 2023
28 Apr 2023
25 May 2023
28 Apr 2023
23 May 2023
28 Apr 2023
16 May 2023
Amount
Supply, Installation & commissioning of 30 Cs V.T. axial flow pump having lift 23.02 feet ,980 RPM including MS Delivery pipe, bend mimimum 8 mm thickness & support of bend duly painted from inside and outside as per site requirement & specification approved by technical committee (Annexure-A) (06 Nos., PH MD-1 to 3). (Tentative Lift at MD-1,2,3,4 is 23.02 feet and at MD-5,6 is 15.00 feet. However as raising of canal is proposed so suggested to consider buffer of 3 feet at each pump house)
Supply, Installation & commissioning of 20 Cs V.T. axial flow pump having lift 23.02 feet ,980 RPM including MS Delivery pipe, bend mimimum 8 mm thickness & support of bend duly painted from inside and outside as per site requirement & specification approved by technical committee (Annexure-A)(06 Nos., PH MD-1 to 3,MD-5, PH MD-4=02 No.) (Tentative Lift at MD-1,2,3,4 is 23.02 feet and at MD-5,6 is 15.00 feet. However as raising of canal is proposed so suggested to consider buffer of 3 feet at each pump house)
Supply, Installation & commissioning of 10 Cs V.T. axial flow pump having lift 23.02 feet ,1440 RPM including MS Delivery pipe, bend mimimum 8 mm thickness & support of bend duly painted from inside and outside as per site requirement & specification approved by technical committee (Annexure-A) (05 Nos., PH MD-5=02 No. & PH MD-6=03 Nos.) (Tentative Lift at MD-1,2,3,4 is 23.02 feet and at MD-5,6 is 15.00 feet. However as raising of canal is proposed so suggested to consider buffer of 3 feet at each pump house)
Supply, Erection and commissioning of solid shaft induction motors of 225 HP suitable for 30 Cs VT axial flow pumps type vertical flange mounted, 167 KW, 980 RPM, 440/415 voltage, 3 phase, 50 Hz as per specifications (Annexure-B) and site requirement. (06 Nos., PH MD-1 to 3)
Supply, Erection and commissioning of Solid shaft motor of capacity 100 HP ,75 KW,980 RPM, 3 phase ,440/415 Volt suitable for 20 Cs. V.T. axial flow pump type vertical flange mounted as per specification approved by technical committee. (06 Nos., PH MD-1 to 3,MD-5, PH MD-4=02 No.)
Supply, Erection and commissioning of solid shaft induction motors of 60 HP suitable for 10 Cs VT axial flow pumps type vertical flange mounted, 45 KW, 1440RPM, 440/415 V, 3 phase, 50 Hz as per specifications (Annexure-B)(05 Nos., PH MD-5=02 No. & PH MD-6=03 Nos.)
Supply, Installation & commissioning of ATS Starter including contactors, micro controller based protection relay, CT's with all allied accessories suitable for 225 HP motor as per specification approved by technical committee. (06 Nos., PH MD-1 to 3 =02 No. each)
Supply, Installation & commissioning of ATS Starter including contactors, micro controller based protection relay, CT's with all allied accessories suitable for 100 HP motor as per specification approved by technical committee.(07 Nos., PH MD-1 to 3,MD-5, PH MD-4=02 No.)
Supply, Installation & commissioning of ATS Starter including contactors, micro controller based protection relay, CT's with all allied accessories suitable for 60 HP motor as per specification approved by technical committee.(05 Nos., PH MD-5=02 Nos. & PH MD-6=03 Nos.)
Supply, Installation & commissioning of LTDB of Capacity 1600 Amps including all accessories as ACB,1600 Amps -01 No incomer,MCCB 630 Amps-03 nos & 250 Amp-03 Nos. outgoing, 63Amp MCB for lighting loads, indicators,relays,meters,push buttons,bus bars etc complete suitable for operation Motors of capacity 225 HP & 100 HP as per specification approved by Tech committee with design capacitor bank of 300 KVAR capacity with 8 APFCR, digital display instrunment and other allied accessories.(02 No., PH MD-1=01 No. & PH MD-2=01 No.)
Supply, Installation & commissioning of LTDB of Capacity 1000 Amps including all accessories as ACB,1000 Amps -01 No incomer,MCCB 630 Amps-02 nos & 250 Amp-04 Nos. outgoing, 63Amp MCB for lighting loads, indicators,relays,meters,push buttons,bus bars etc complete suitable for operation Motors of capacity 225 HP & 100 HP as per specification approved by Tech committee with design capacitor bank of 250 KVAR capacity with 8 APFCR, digital display instrunment and other allied accessories.(01 No. at PH MD-3)
Supply, Installation & commissioning of LTDB of Capacity 1000 Amps including all accessories as ACB,1000 Amps -01 No incomer,MCCB, 250 Amp-05 Nos. outgoing, 63Amp MCB for lighting loads, indicators,relays,meters,push buttons,bus bars etc complete suitable for operation of 05 Nos 100 HP as per specification approved by Tech committee with design capacitor bank of 200 KVAR capacity with 8 APFCR, digital display instrunment and other allied accessories. (03 No.,PH MD-4=01 No. PH MD-5=01 No. PH MD-6=01 No.)
Providing & fixing by making required size /length at site in pair of MS cross Girder (ISMB) of size 300mmx150mm for foundation of 30 CS VT Axial Flow pump including supply,fixing & welding on bottom side of ISMB through out length with MS flat of 150mmx10 mm thick. One end of ISMB shall be grouted into wall by making arrangement Of PCC block of suitable size as per weight of pump set of 30 Cs capacity and other end shall be welded with fixing of A.I. L- bracket and nut/bolts/washers etc fitting with ISMB member. Including Material & Labour for applying primer coat with metal primer on new steel or iron work including preparation of surface and Material & labour for painting two coats excluding primer coat with ready mixed paint (Epoxy paint) for metallic surface in all shades on new steel or iron work..MAKE: TATA/JINDAL/SAIL/VAIZAG (18 pair., PH MD-1=04 Pair. , PH MD-2=03 Pair.& PH MD-3=03 Pair. PH MD-4=02 Pair. PH MD-5=03 Pair. PH MD-6=03 Pair.)
Providing & fixing by making required size /length at site ISMB of size 600mmx210mm for support of foundation girder for 3 Nos 30 Cs VT Axial Flow pump including supply,fixing both end of ISMB shall be grouted into wall by making arrangement Of PCC block of suitable size as per weight of pump set of 3 Nos 30 Cs. Including Material & Labour for applying primer coat with metal primer on new steel or iron work including preparation of surface and Material & labour for painting two coats excluding primer coat with ready mixed paint (Epoxy paint) for metallic surface in all shades on new steel or iron work. Taking down by cutting / welding the existing rusted/ old foundation girder for fixing new girder at site.MAKE: TATA/JINDAL/SAIL/VAIZAG (One No. at each Pump House MD-1 to MD-6).
Providing and fixing of chemical earthing by digging 200 mm bore 20 feet depth complete with GI electrode with GI strip (for LTDB, starters, pumps and motors) in Pump Houses with coke and salt etc. as per site requirement for newly installed equipments ( PHMD-1 to MD-6)
Prvoding & fixing of lightening arrester with protection radius 100 meter alongwith lightening strike counter & earthing arrangment as per proper specification for pump house and as per the site requirement. (MD-1 to MD-6 )
Supply errection and commissioning of LT single core Aluminum conductor 630 sqmm XLPE insulated, Armoured cable from neutral of transformers to LTD Panels & from transformer to panel in Pump House by providing suitable size thimbles at both ends conforming to IS standards and as per approved make.(MD-1 to MD-6 )
Supply errection and commissioning of LT Armoured PVC Aluminum cable of size 185 sqmm 3 core confirming to IS 7098-1995 as per approved make. (MD-1 to MD-6 )
Supply of LT Armoured PVC Aluminum cable of size 95 sqmm 3 core confirming to IS 7098-1995 as per approved make. (MD-1 to MD-6 )
MOHINI ELECTRICALS LTD.
Avon Engineering Company
ace marketing pvt ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .